| | Q | CCA | Title |
|---|
| 05000352/FIN-2017007-01 | 2017Q4 | H.6 | Failure to Document Technical Basis for Service Temperature Changes for Limitorque Motor Operated Valve Limit Switches |
| 05000353/FIN-2017004-01 | 2017Q4 | H.5 | Unplanned HPCI Inoperability Due to Isolating All Suction Sources During Post-Maintenance Te s t i n g |
| 05000353/FIN-2018001-01 | 2018Q1 | | Failure of Emergency Diesel Generator Lube Oil Pipe Nipple Fitting |
| 05000352/FIN-2018001-02 | 2018Q1 | | Emergency Diesel Generator Combustion Air Overheating |
| 05000352/FIN-2018002-01 | 2018Q2 | H.11 | Failure to Conduct Adequate Radiation Surveys and Evaluate Potential Radiological Hazards |
| 05000352/FIN-2018002-02 | 2018Q2 | | Unit 1 Core Spray Pump Failed to Start Resulting in Condition Prohibited by Technical Specifications |
| 05000352/FIN-2018003-01 | 2018Q3 | H.8 | Failure to Assess and Manage Risk Associated with Fuel Oil Storage Tank Maintenance |
| 05000352/FIN-2018003-02 | 2018Q3 | H.13 | Failure to Correct Adverse Environmental Conditions Impacting Low Pressure Coolant Injection Outboard Primary Containment Isolation Valve |
| 05000352/FIN-2018010-01 | 2018Q3 | | Minor Violation |