| | | Reporting criterion |
|---|
| 05000346/LER-1997-001, :on 970122,nuclear Instrumentation Declared Inoperable & Incapable of Performing Safety Functions.Caused by Small Shift in Degraded Bottom Linear Amplifier.Power Range Bottom Linear Amplifier Replaced |
- on 970122,nuclear Instrumentation Declared Inoperable & Incapable of Performing Safety Functions.Caused by Small Shift in Degraded Bottom Linear Amplifier.Power Range Bottom Linear Amplifier Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-002-01, :on 970122,identified Potential Overpressurization of Penetrations During Accident Conditions.Installed Mod to Protect Component Cooling Water Supply from Overpressurization Concerns on 970504 |
- on 970122,identified Potential Overpressurization of Penetrations During Accident Conditions.Installed Mod to Protect Component Cooling Water Supply from Overpressurization Concerns on 970504
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition |
| 05000346/LER-1997-002, :on 970122,identified Potential Overpressurization of Penetrations During Accident Conditions.Plant Mods & Procedure Changes Being Developed to Prevent Overpressurization of Piping |
- on 970122,identified Potential Overpressurization of Penetrations During Accident Conditions.Plant Mods & Procedure Changes Being Developed to Prevent Overpressurization of Piping
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-004-01, Regarding Reactor Coolant Pump Motor Oil Piping Not Protected from Leakage as Required Per 10CFR50, Appendix R | Regarding Reactor Coolant Pump Motor Oil Piping Not Protected from Leakage as Required Per 10CFR50, Appendix R | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition |
| 05000346/LER-1997-004, :on 970203,RCP Motor Oil Piping Was Not Protected from Leakage as Required Per 10CFR50 App R.Caused by Personnel Not Realizing Pressurized Piping in Area. Mods Made to Contain Piping as Necessary |
- on 970203,RCP Motor Oil Piping Was Not Protected from Leakage as Required Per 10CFR50 App R.Caused by Personnel Not Realizing Pressurized Piping in Area. Mods Made to Contain Piping as Necessary
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000346/LER-1997-005-01, Forwards LER 97-005-01 to Document Completion of Corrective Actions Taken Re 970212 Event.Changes Are Marked W/Rev Bar in Right Margin | Forwards LER 97-005-01 to Document Completion of Corrective Actions Taken Re 970212 Event.Changes Are Marked W/Rev Bar in Right Margin | |
| 05000346/LER-1997-006, :on 970225,both Containment Radiation Monitors Were Found to Be Missing Gaskets on Particulate Filter & Iodine Cartridge Holders.Caused by Lack of Procedural Guidance.Missing Gaskets Were Replaced |
- on 970225,both Containment Radiation Monitors Were Found to Be Missing Gaskets on Particulate Filter & Iodine Cartridge Holders.Caused by Lack of Procedural Guidance.Missing Gaskets Were Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000346/LER-1997-007, :on 970305,determined That Acceptance Criteria of Surveillance Test to Measure Leakage Into Dh Valve Pit Potentially non-conservative.Caused by Human Error. Surveillance Test Revised |
- on 970305,determined That Acceptance Criteria of Surveillance Test to Measure Leakage Into Dh Valve Pit Potentially non-conservative.Caused by Human Error. Surveillance Test Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000346/LER-1997-008, :on 970318,inadequate Testing of safety-related Logic Occurred.Overall Root Cause Will Be Completed by 980930 & Results of Evaluation Will Be Reported in Suppl to LER |
- on 970318,inadequate Testing of safety-related Logic Occurred.Overall Root Cause Will Be Completed by 980930 & Results of Evaluation Will Be Reported in Suppl to LER
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-008-14, Forwards LER 97-008-14,providing Info Re 970318 Occurrence. Revision Bars in Margins Mark Changes.Destroy or Mark Superseded on Previous Copies of LER | Forwards LER 97-008-14,providing Info Re 970318 Occurrence. Revision Bars in Margins Mark Changes.Destroy or Mark Superseded on Previous Copies of LER | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000346/LER-1997-008-05, Forwards LER 97-008-05 Re Inadequate Testing of Safety Related Logic | Forwards LER 97-008-05 Re Inadequate Testing of Safety Related Logic | |
| 05000346/LER-1997-008-12, Forwards LER 97-008-12,providing Addl Info on 970318 Occurrence.Changes Marked W/Rev Bar in Margin.Util Requests That NRC Destroy or Mark Superseded on Previous Copies of LER | Forwards LER 97-008-12,providing Addl Info on 970318 Occurrence.Changes Marked W/Rev Bar in Margin.Util Requests That NRC Destroy or Mark Superseded on Previous Copies of LER | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000346/LER-1997-008-10, Forwards LER 97-008-10,providing Addl Info Re 970318 Occurence.Rev Bar in Margin Indicates Changes.Destroy or Mark Superseded on Previous Copy of LER | Forwards LER 97-008-10,providing Addl Info Re 970318 Occurence.Rev Bar in Margin Indicates Changes.Destroy or Mark Superseded on Previous Copy of LER | 10 CFR 50.73(a)(2)(i) |
| 05000346/LER-1997-008-13, Forwards LER 97-008-13 Re Inadequate Testing of Safety Related Logic.Changes Marked W/Rev Bar in Margin | Forwards LER 97-008-13 Re Inadequate Testing of Safety Related Logic.Changes Marked W/Rev Bar in Margin | |
| 05000346/LER-1997-008-01, :on 961113,switchboard Circuit Was Declared Inoperable Due to Switchyard Breaker Alignment.Caused by Misunderstanding of Design.Standing Order Was Issued on 961121 to Provide Guidance for Entering TS |
- on 961113,switchboard Circuit Was Declared Inoperable Due to Switchyard Breaker Alignment.Caused by Misunderstanding of Design.Standing Order Was Issued on 961121 to Provide Guidance for Entering TS
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-009-01, Forwards LER 97-009-01,providing Revised Date of Completion for Corrective Actions to Implement New Funtional Test Surveillance Procedure for Testing of Essential Electrical Bus Undervoltage Relays | Forwards LER 97-009-01,providing Revised Date of Completion for Corrective Actions to Implement New Funtional Test Surveillance Procedure for Testing of Essential Electrical Bus Undervoltage Relays | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000346/LER-1997-010, :on 970504,Main Transformer Deluge Sys Automatically Actuated Due to Degraded Temp Sensor in Transformer Fire Detection Sys.Replaced Damaged Main Transformer & Sensors That Actuate Deluge Sys |
- on 970504,Main Transformer Deluge Sys Automatically Actuated Due to Degraded Temp Sensor in Transformer Fire Detection Sys.Replaced Damaged Main Transformer & Sensors That Actuate Deluge Sys
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000346/LER-1997-011, :on 970825,emergency Ventilation Sys Rendered Inoperable by Maint on Room Isolation Valve Occurred.Caused by Misinterpretation of Tech Spec.Preventive Maint Activities Revised |
- on 970825,emergency Ventilation Sys Rendered Inoperable by Maint on Room Isolation Valve Occurred.Caused by Misinterpretation of Tech Spec.Preventive Maint Activities Revised
| 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-012, :on 970904,decay Heat Cooler Seismic Design Inadequacy Occurred.Caused by Inadequate Design of Decay Heat Coolers Support Sys.Decay Heat Cooler Mounting Support Sys Will Be re-evaluated & Modified |
- on 970904,decay Heat Cooler Seismic Design Inadequacy Occurred.Caused by Inadequate Design of Decay Heat Coolers Support Sys.Decay Heat Cooler Mounting Support Sys Will Be re-evaluated & Modified
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000346/LER-1997-012-01, Forwards LER 97-012-01,which Is Being Submitted to Revise Completion Date for Recommended Corrective Action.Changes Marked W/Rev Bar in Margin | Forwards LER 97-012-01,which Is Being Submitted to Revise Completion Date for Recommended Corrective Action.Changes Marked W/Rev Bar in Margin | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-013, :on 971002,potential Condition Adverse to Quality Rept Documented Failure to Perform Surveillance Test Before TS Surveillance Late Date.Caused by Administrative Error.Missed Surveillance Completed |
- on 971002,potential Condition Adverse to Quality Rept Documented Failure to Perform Surveillance Test Before TS Surveillance Late Date.Caused by Administrative Error.Missed Surveillance Completed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-014-01, :on 970801,pressurizer PORV Setpoint Was Less than Allowable Value.Caused by Degraded Wire Splice.Wire Containing Faulty Splice Was Replaced |
- on 970801,pressurizer PORV Setpoint Was Less than Allowable Value.Caused by Degraded Wire Splice.Wire Containing Faulty Splice Was Replaced
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000346/LER-1997-015, :on 971210,EDG Tachometer Circuit Was Noted Outside 10CFR50 App R Design Basis.Caused by Less than Adequate Development & Review of Mod 84-0183.Established Hourly Fire Watch in Cable Spreading Room |
- on 971210,EDG Tachometer Circuit Was Noted Outside 10CFR50 App R Design Basis.Caused by Less than Adequate Development & Review of Mod 84-0183.Established Hourly Fire Watch in Cable Spreading Room
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000346/LER-1997-015-01, Forwards LER 97-015-01,which Is Being Submitted Ro Provide Addl Info Re Corrective Actions Being Taken as Result of Subj Occurrence.Changes Marked W/Rev Bar in Margin | Forwards LER 97-015-01,which Is Being Submitted Ro Provide Addl Info Re Corrective Actions Being Taken as Result of Subj Occurrence.Changes Marked W/Rev Bar in Margin | |
| 05000346/LER-1997-016-01, :on 971217,monthly ECCS Valve Position SR Was Missed.Caused by Flow Path That Was Not Part of Contiguous ECCS Flow Path Envisioned for Compliance W/Ts 4.5.2.Verified Valves Open on 971222 |
- on 971217,monthly ECCS Valve Position SR Was Missed.Caused by Flow Path That Was Not Part of Contiguous ECCS Flow Path Envisioned for Compliance W/Ts 4.5.2.Verified Valves Open on 971222
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |