05000346/LER-1983-003, Forwards LER 83-003/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 83-003/03L-0
ML20071B568
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 02/16/1983
From: Murray T
TOLEDO EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20071B569 List:
References
K83-337, NUDOCS 8302280419
Download: ML20071B568 (1)


LER-1983-003, Forwards LER 83-003/03L-0
Event date:
Report date:
3461983003R00 - NRC Website

text

a i

o i

, g.

TOLEDO

%mm EDISON February 16, 1983 Log No. K83-337 File: RR2 (NP-33-83-06)

Docket No. 50-346 License No. NPF-3 Mr. James G. Keppler Regional Administrator, Region Ill Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Dear Mr. Keppler:

LER No.83-003 Davis-Besse Nuclear Power Station Unit 1 Date of Occurrence: January 18, 1983 Enclosed are three copies of Licensee Event Report 83-003 which are 1,eing submitted in accordance with Technical Specification 6.9 to provide 30 day written notification of the subject occurrence.

Yours truly,

@ o. wwyff Terry D. Murray Station Superintendent Davis-Besse Nuclear Power Station TDM/ljk Enclosures cc:

Mr. Richard DeYoung, Director Office of Inspection and Enforcement Encl:

30 copies l

Mr. Norman Haller, Director l

Office of Management and Program Analysis Encl:

3 copies Mr. Tom Peebics NRC Resident Inspector Encl:

1 copy d bd 8302280419 830216 PDR ADOCK 05000346 FEB 221983 S

PDR THE TOLEOO EOl3ON COMPANY EOISON PLAZA 300 MADISON AVENUE TOLEDO, OHIO 43652 2