05000331/LER-2013-003, Regarding Condition Prohibited by Technical Specifications - Spent Fuel Storage

From kanterella
(Redirected from 05000331/LER-2013-003)
Jump to navigation Jump to search
Regarding Condition Prohibited by Technical Specifications - Spent Fuel Storage
ML13317B923
Person / Time
Site: Duane Arnold 
(DPR-049)
Issue date: 11/11/2013
From: Richard Anderson
NextEra Energy Duane Arnold
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NG-13-0411 LER 13-003-00
Download: ML13317B923 (5)


LER-2013-003, Regarding Condition Prohibited by Technical Specifications - Spent Fuel Storage
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(iii)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications
3312013003R00 - NRC Website

text

NEXTera ENERGYa

,ý;ýA RNOLD November 11, 2013 NG-13-0411 10 CFR 50.73 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 Duane Arnold Energy Center Docket 50-331 Renewed Op. License No. DPR-49 Licensee Event Rer)ort #2013-003 Please find attached the subject report submitted in accordance with 10 CFR 50.73. This letter makes no new commitments or changes to any existing

commitments

Richard L. Anderson Vice President, Duane Arnold Energy Center NextEra Energy Duane Arnold, LLC 01 NextEra Energy Duane Arnold, LLC, 3277 DAEC Road, Palo, IA 52324

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB NO. 3150-0104 EXPIRES: 10/31/2013 (10-20 10)

, the (See reverse for required number of NRC may not conduct or sponsor, and a person is not required to respond to, the digits/characters for each block) information collection.

I. FACILITY NAME

2. DOCKET NUMBER
3. PAGE Duane Arnold Energy Center 05000331 1 OF 4
4. TITLE Condition Prohibited by Technical Specifications - Spent Fuel Storage
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED MONTH DAY YEAR YEAR SEQUENTIAL REV MONTH DAY YEAR FACILITY NAME DOCKET NUMBER NUMBER NO.

N/A 05000 09 11 13 2013 003 0

11 11 13 FACILITY NAME DOCKET NUMBER N/A 05000

9. OPERATING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)

E]

20.2201(b)

[

20.2203(a)(3)(i)

[I]

50.73(a)(2)(i)(C)

[]

50.73(a)(2)(vii) 1

[] 20.2201(d)

[

20.2203(a)(3)(ii)

[]

50.73(a)(2)(ii)(A)

[

50.73(a)(2)(viii)(A)

EZ 20.2203(a)(1)

[

20.2203(a)(4)

EI 50.73(a)(2)(ii)(B)

[

50.73(a)(2)(viii)(B)

[] "20.2203(a)(2)(i)

Ej 50.361)(1)(i)(A)

[]

50.73(a)(2)(iii)

[]

50.73(a)(2)(ix)(A)

10. POWER LEVEL

[

20.2203(a)(2)(ii)

[I 50.36(c)(l)(ii)(A)

[

50.73(a)(2)(iv)(A)

LI 50.73(a)(2)(x)

I] 20.2203(a)(2)(iii)

[] 50.36(c)(2)

LI 50.73(a)(2)(v)(A)

Ej 73.71(a)(4) 100%

LI 20.2203(a)(2)(iv)

[I 50.46(a)(3)(ii)

[

50.73(a)(2)(v)(B)

[

73.71(a)(5)

LI 20.2203(a)(2)(v)

LI 50.73(a)(2)(i)(A)

LI 50.73(a)(2)(v)(C)

[

OTHER LI 20.2203(a)(2)(vi)

[

50.73(a)(2)(i)(B)

F-]

50.73(a)(2)(v)(D)

VOLUNTARY LER

12. LICENSEE CONTACT FOR THIS LER NAIVIE TELEPHONE NUMBER (Include Area Code)

Robert J. Murrell, Engineering Analyst (319) 851-7900CAUSE SYSTEM COMPONENT MANU-REPORTABLE K

CAUSE

SYSTEM COMPONENT MANU-REPORTABLE FACTURER TO EPIX d

FACTURER TO EPIX

14. SUPPLEMENTAL REPORT EXPECTED
15. EXPECTED MONTH DAY YEAR II YES (If yes, complete 15. E.XPECTED SUBMISSION DATE)

D NO DATE ABSTRACT (Limit to 1400 spaces, i.e., approximately 15 single-spaced Iypewritten lines)

On September 11, 2013, while operating at 100% power, Boron-10 Areal Density Gage for Evaluating Racks (BADGER) test results from June 2013 testing were received by NextEra Energy Duane Arnold, LLC. The results indicated that the areal density used in the criticality analysis of record may not be supported. Specifically, the report indicated that the areal density assumed in the criticality analysis of record as discussed in UFSAR Section 9.1.2.2.1 may not be supported. This conclusion was based on eleven of the tested panels having an average areal density (mass per unit area) below the minimum of 0.0232 gm-B 10/cm 2 (grams of Boron-10 per squared-centimeter) and nineteen of the tested panels having a minimum (2-inch) areal density below the minimum of 0.0232 gm-B 10/cm2. Since the previously noted assumed minimum areal density in the criticality analysis cannot be supported based on testing results, the PaR spent fuel pool racks do not conform to K-infinity and enrichment limits of DAEC Technical Specification (TS)

Design Specifications 4.3.1.1 (i) and 4.3.1. 1 (iii). Therefore, the racks were determined to be Operable but Non-Conforming. This event resulted in a Condition Prohibited by TS and is reportable pursuant of 10 CFR 50.73(a)(2)(i)(B). A Root Cause Evaluation determined the root cause to be insufficient margin to allow for the uncertainty added by BADGER testing.

NRC FORM 366 (10-2010).

PRINTED ON RECYCLED PAPER (If more space is required, use additional copies of (If more space is required, use additional copies of (If more space is required, use additional copies of NRC Form 366A) (17)

IV.

Corrective Actions

As an interim corrective action, STP 4.3.1-01, "Fuel Storage Facilities K-Infinity Limit Checks" was revised to provide more rigorous controls on the PaR rack cells to ensure fuel with K-infinity > 1.29 is not loaded or stored in the PaR racks.

Corrective actions to prevent recurrence will be taken to revise the criticality analysis to include additional margin for B 10 areal density to bound testing uncertainty to support future neutron attenuation testing.

This action will also include revising the UFSAR and TS in order to address the Operable but Non-Conforming condition.

V.

Additional Information

Previous Similar Occurrences:

A review of License Event Reports from the past 5 years did not identify any similar occurrence.

EIIS System and Component Codes:

DB - Nuclear Fuel Services System.

Reporting Requirements

This event is being reported as an Operation or Condition Prohibited by TS, 1 OCFR50.73(a)(2)(i)(B).PRINTED ON RECYCLED PAPER