Finding | |
|---|---|
| Title | Failure to Conduct an Adequate Critique for the May 20, 2009, Drill |
| Description | A finding of very low safety significance and associated NCV of 10 CFR Part 50, Appendix E,Section IV.F.2.g, and of the emergency planning standard 10 CFR 50.47(b)(14) was identified by the inspectors for the failure of the critique to identify a planning standard weakness. Specifically, during the 2009 Emergency Response Organization (ERO) Training Drill #2 conducted on May 20, 2009, the licensees critique process failed to identify a performance problem associated with communications between the Control Room/Simulator (CRS) and the Technical Support Center (TSC) and, as a result, the deficiency was not corrected. The CRS provided inaccurate information necessary for an Emergency Action Level (EAL) classification to the TSC concerning the reactor water level which prompted a controller injection to stop a potential inaccurate classification. The licensee entered the finding into their corrective action program (CAP 068506 and CE 007572). The performance deficiency was determined to be more than minor because the deficiency adversely affected the Emergency Preparedness Cornerstone objective to ensure the licensee is capable of implementing adequate measures to protect the health and safety of the public in a radiological emergency, as demonstrated by the ERO performance in a drill. The inspectors used IMC 0609, Appendix B, and determined the deficiency was similar to the Green example of the drill critique process not properly identifying a weakness resulting from a performance problem associated with a risk significant planning standard 10 CFR 50.47(b)(14). Therefore, the finding was screened to be of very low safety significance (Green). The cause of the finding had a cross -cutting component in the problem identification and resolution area of self and independent assessments P.3(a) |
| Site: | Duane Arnold |
|---|---|
| Report | IR 05000331/2010002 Section 1EP5 |
| Date counted | Mar 31, 2010 (2010Q1) |
| Type: | NCV: Green |
| cornerstone | Emergency Prep |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71114.05 |
| Inspectors (proximate) | K Riemer R Orlikowski M Mitchell R Baker V Meghani R Russell R Murray P Smagacz |
| CCA | P.6, Self-Assessment |
| INPO aspect | CL.2 |
| Finding closed by | |
| IR 05000331/2010002 (14 May 2010) | |
| ' | |
Finding - Duane Arnold - IR 05000331/2010002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Duane Arnold) @ 2010Q1
Self-Identified List (Duane Arnold)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||