05000324/LER-1981-083-03, Reactor Core Isolation Cooling Turbine Steam Supply Inboard Isolation Valve Closed. Caused by Spurious RCIC Isolation Logic Bus a Signal Due to Cold Solder Joint in Ambient Temp Switch.Switch Resoldered

From kanterella
(Redirected from 05000324/LER-1981-083-03)
Jump to navigation Jump to search
Reactor Core Isolation Cooling Turbine Steam Supply Inboard Isolation Valve Closed. Caused by Spurious RCIC Isolation Logic Bus a Signal Due to Cold Solder Joint in Ambient Temp Switch.Switch Resoldered
ML20010H957
Person / Time
Site: Brunswick 
Issue date: 09/18/1981
From: Pastva M
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20010H956 List:
References
LER-81-083-03L, LER-81-83-3L, NUDOCS 8109290447
Download: ML20010H957 (1)


LER-1981-083, Reactor Core Isolation Cooling Turbine Steam Supply Inboard Isolation Valve Closed. Caused by Spurious RCIC Isolation Logic Bus a Signal Due to Cold Solder Joint in Ambient Temp Switch.Switch Resoldered
Event date:
Report date:
3241981083R03 - NRC Website

text

NRC FORM 366 U. S. NUCLE AR REGULATORY COMMISSION Update Report (7-771-LICENSEE EVENT REPORT Previous Report Date 9-11-81 CONTROL BLOCK: l l

l l

l l

lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) i e

lo l1l l N l C l B l E lP l 2 l@l0 l0 l-l0 l0 l0 l0 l0 l-l0 l0j@l 4 l 1l 1l ll 1l@l l

l@

7 8 9 LICENSEE CODE 14 15 L' CENSE NUMBED 25 26 LICENSE TYPE JO

$7 CAT $8 CON'T lolil S$RN I L hl 0 l 5 l 0 l-l0 13 l 2 l4 @l01812 l5 18 Il l@lOl91138]8l1l@

?

8 60 6.

DOCKET NUMBER 68 69 EVENT DATE F4 75 REPOR i DATE 80 EVENT DESCRIPTION ANO PROBABLE CONSEQUENCES h Fol2l [During plant operation with no evoluations in progress, the RCIC System automatically l l isolated due to the receipt of a spurious RCIC isolation logic bus A rignal that l

lo la l [resulted in the closure of the RCIC turbine steam supply inboard isolation valve, l

lo l4 l l o i s i 1 -E51-F007.

Surveillance of the back panel temperature instruments revealed that tempq 2

l o 16 l lerature indicator ZE51-TS-N603A was failed downscale. At the time of this event, the l

l 0 l 7 l l HPCI System was operable. This event did not affect thehealthandsafetyofthepublje.

Technical Specifications 3.7.4, 6.9.1.9b, 3.3.2 l

,o,g, l

80 7

8 9 C DE CODE SUBCO E COMPONENT CODE SUBC DE SU E

lo191 l C l E l@ l El@ l A l@ l Il N j S l Tl Rl U[g l El@ g g 7

8 9

1U 11 12 13 18 19 20 SEQUENTIAL OCCURRENCE REPORT REVISIGN

_ EVENT YE AR REPORT NO.

CODE TYPE NO.

b "LE R ACl8l1l l-l lf ' 8 l 3 l l/l l0 l3 l lL l

[---j l1 l sU{jRT E

_ 21 22 23 24 26 21 28 29 30 31 32 AK N ACT ON ON F ANT ET HOURS S8 IT FOR B.

SUPPLIE MA rACTUREa lB lg J @

lZ l@

l Zl@

l 0l 0l 0l 0l l Nlg Wg l N jg l S l 0 l 5 l4 l@

33 J4 JS 36 3/

40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS IiloIlA cold solder icint in the module circuitry of the RCIC System steam line area ambient [

[iIii ltemperature switch, 2-E51-TS-N603A, model no. 86PTGF, caused the instrument to spike. I 121 lthen downscale and initiate an RCIC isolation on high temperature. The joint was resold lered, l

No l I i l 3 l l the module was tested and calibrated and the RCIC System was returned to service.

l reason could be determined for the failed joint, which was made by the module manufactu4er.

1iI4l 80 7

8 9 ST S

% POWE R OTHER STATUS IS OV RY DISCOVERY DESCRtPTION NA l l A l@l Operational Event l

li l 5 l l E l@ l 0 l 9 l 6 l@l A(. TIVI TY CONTENT RELEASED OF RE LE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE NA l l

NA l

y @ [Z_j@l 1 6 7

H 9 10 11 44 45 80 PERSONNEL E XPOSURES NUYBER TYPE

DESCRIPTION

NA l

l1l7]

0l0l@lZlhl 80 PERSONNE L INJURIES NUV8ER DESCRIP TION l1 la l l0 l0 l0 l@l NA l

80 7

8 9 11 12 LOSS OF OH D AM AGE TO F ACILITY TYPE DE SCRIP TION NA l

l 1 l 9 l lZ l@l 80 7

H 9 10 810M9046 810918 NRC USE ONLY PUIR lCI T Y PDR ADO M 05000M4

'D CSU(D Lv R lN,j@DESCRIP, l

S PDR NA J

lllllllllllll?

F8 69 80 N AME OF PREPAREh PHONE: