05000318/LER-2022-002, Unplanned Safety Injection Actuation Signal Due to Human Error

From kanterella
(Redirected from 05000318/LER-2022-002)
Jump to navigation Jump to search
Unplanned Safety Injection Actuation Signal Due to Human Error
ML22316A019
Person / Time
Site:  Constellation icon.png
Issue date: 11/11/2022
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML22316A017 List:
References
LER 2022-002-00
Download: ML22316A019 (1)


LER-2022-002, Unplanned Safety Injection Actuation Signal Due to Human Error
Event date:
Report date:
3182022002R00 - NRC Website

text

Abstract

OnSeptember14,2022,withUnit2inMode5(ColdShutdown)duringcooldownforamaintenanceoutage, OperationscommencedperformanceofOI342,Section6.8/AppendixJ,BypassingSIASandSIASBlockSensor ModulesinMode5,6,orDefueled,insupportofOP052,PlantShutdownfromHotStandbytoColdShutdown.During performanceoftheOI342evolution,anunplannedSafetyInjectionActuationSignal(SIAS)occurredduetoOperator failuretocomplywithstationprocedureuseandadherencestandards.TheunplannedSIASresultedintheautomatic startofthesites2ADieselGenerator(DG)and2BDG.TheunplannedSIASdidnotresultinsafetyinjectionintothe reactorcoolantsystemnordiditadverselyimpactshutdowncoolingoperations.

(See Page 3 for required number of digits/characters for each block)

(See NUREG-1022, R.3 for instruction and guidance for completing this form http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr1022/r3/)

Page 5 of 5 SafetyImpact

Thesafetysignificanceofthiseventwasminimal.Atthetimeoftheevent,Unit2wasinMode5andtheHPSILTOP tagoutwasinplace,preventingtheinjectionofhighpressuremakeupintothereactorcoolantsystemwhileinalow temperaturecondition.BothLPSIPumpswerealreadyinoperationprovidingcoolingflowviatheSDCsystem.SDC operationwasnotadverselyimpactedbytheunplannedSIAS.AlthoughbothUnit2dieselgenerators,the2ADGand 2BDG,receivedautomaticstartsignalsfromtheunplannedSIASAandB,sincetherewasnolossofeitherthe214KV Bus(safetyrelatedZAtrainbussupportedbythe2ADG)orthe244KVBus(safetyrelatedZBtrainbussupportedby the2BDG),neitherofthedieselgeneratorsloadedontotheirrespectivebus.Followingtheautomaticstartofthe2A DGand2BDG,bothdieselgeneratorsoperatedsatisfactorilyuntilsecured.

F.CORRECTIVEACTIONS

TheCAPproductperformedunderIR4522477identifiedthefollowingcorrectiveactionsthatareplannedtobetaken toaddresscauseandextentofconditionfromtheeventinvestigation:

(1)PerformedaCorrectiveActionProgramevaluation.

(2)AddressedpersonnelaccountabilityactionsinaccordancewithHumanResourcepolicies.

(3)ReviseapplicableESFAS/AuxiliaryFeedwaterActuationSystem(AFAS)procedurestoclearlydelineate supervisoryoversightwhileperformingthetasks.

G.PREVIOUSOCCURRENCES

AreviewofCalvertCliffsreportableeventsbacktoJanuary2012wasperformed.TherewerenoLERsthatinvolved unplannedESFASactuationsastheresultofpersonnelerrors.

LER3182021004,Unit2ManualReactorTripDuetoLoweringSteamGeneratorLevels,doesdocumentaUnit2 manualreactortripthatwasinitiatedbyapersonnelerrorwhenbreakerstabcoverswerenotremovedpriorto attemptingtoenergizethe12SpentFuelPoolCoolingPump(SFPCP).Uponattemptingtoenergizethe12SFPCP,an arcflasheventoccurredthatresultedinthelossofthe24A480VLoadCenterthatledultimatelytotheneedfor OperationstomanuallytriptheUnit2reactor.

H.COMPONENTFAILUREDATA

Therewerenocomponentfailuresidentifiedthatcontributedtothiseventoroccurredasaresultofthisevent.