CATEGORY 1 REGULA Y INFORMATION DISTRIBUTI SYSTEM (RIDS)
ACCESSION NBR:9808060272 DOC.DATE: 98/07/31 NOTARIZED: NO DOCKET FACIL:50-315 Donald C.
Cook Nuclear Power Plant, Unit 1, Indiana M
05000315 AUTH.NAME AUTHOR AFFILIATION PISARSKY,F.
American Electric Power Co., Inc.
SAMPSON,J:R.
American Electric Power Co., Inc.
RECIP.NAME RECIPIENT AFFILIATION
SUBJECT:
LER 98-008-02:on 980112,inadecpxate contractor control during maint
& surveillance activities resulted in ice basket damage. Procedures used to guide maint 6 surveillance
. activities have been upgraded
& rewritten.W/980731 ltr.
DISTRIBUTION CODE: IE22T COPIES RECEIVED:LTR ENCL SIZE:
TITLE: 50.73/50.9 Licensee Event Report (LER),
ncident Rpt,. etc.
NOTES:
E RECIPIENT ID CODE/NAME PD3-3 PD COPIES
'ECIPIENT LTTR ENCL ID CODE/NAME 1
1 STANG, J COPIES LTTR ENCL 1
1 INTERNAL: AEOD/SPD/RAB R7'XG~
ELB NRR/DRCH/HICB NRR/DRCH/HQMB NRR/DSSA/SPLB RGN3 FILE 01 EXTERNAL: L. ST LOBBY WARD NOAC POORE,W.
NRC
~ PDR 2
2 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 AEOD/SPD/RRAB NRR/DE/ECGB NRR/DE/EMEB
'RR/DRCH/HOHB NRR/DRPM/PECB RES/DET/EIB LITCO BRYCE,J H NOAC QUEENER,DS NUDOCS FULL TXT 1
1 1
1 1
1.
1 1
1 1
1 1
1 1
1 1
1 1
D 0
E N
NOTE TO ALL "RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE WASTE. TO HAVE YOUR NAME OR ORGANIZATION REMOVED FROM DISTRIBUTION LISTS OR REDUCE THE NUMBER OF COPIES RECEIVED BY YOU OR YOUR ORGANIZATION, CONTACT THE DOCUMENT CONTROL DESK (DCD)
ON EXTENSION 415-2083 FULL TEXT CONVERSION REQUIRED TOTAL NUMBER OF COPIES REQUIRED:
LTTR 22 ENCL 22
American Electric Po r
Cook Nuclear Plant One Cook Place Bridgrnan, MI49t06 6t6465590l AMERICAN a'CaCrR]C POWER July 31, 1998 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Operating Licenses DPR-58 Docket No. 50-315 Document Control Manager:
In accordance with the criteria established by 10 CFR 50.73 entitled Licensee Event
~pfg igp igp 98-008-02 Sincerely,
.~gg J. R. Sampson Site Vice President
/mbd Attachment C. J.
Paperiello (Acting), Region III J. R.
Sampson P. A.
Barrett S. J.
Brewer R.
Whale D.
Hahn Records Center, INPO NRC Resident Inspector 98080b0272 980732 PDR ADQCK 05000325 8
PDR
NRC Form 366
.I) (4-95) 0 U.S. NUCLEAR REGULATORYCOMMISSION LICENSEE EVENT REPORT (LER)
(See reverse for required number of digits/characters for each block)
APPROVED BYOMS NO. 51504H04 EXPIRES 04r)ol55 ESTSIATED BURDEN PER
RESPONSE
TO COMPLY 'ATTN THIS MANDATORY INFORMATIONCOLLECTION REOUKST: 50.0 HRS. REPORTED LESSONS IEARNEO ARE SICORPORATKO UITO THK UCENSING PROCESS AND FED SACK TO SIDVSTRY. FORWARD COMMENTS REGARIXNG BURDEN ESTIMATE TO THE INFORMATIONAND RECORDS MANAGENIENTBRANCH (T4 F55). U.S. NVCLEAR REGVIATORY COMISSSION, WASHINGTON. DC 205554001.
AND TO THE PAPERWORK REDUCTION PROIKCT (51504104). OFFICE OF MANAGEMENTANO SUDGKT,WASleNGTON. OC 20505 FACIUTYNAME(I)
Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 50-315 PAGE(3) 1 of6 TITLE(4)
Inadequate Contractor Control During Maintenance and Surveillance Activities Results in Ice Basket Damage EVENT DATE (5)
MONTH DAY YEAR 02 12 98 LER NUMBER(6)
REPORT DATE (7)
YEAR SEQUENTIAL NUMBER 98
008 REVISION MONTH NUMBER 02 07 DAY 31 YEAR A ILI NAM Cook - Unit 2 A ILITYNAM 98 NUMBE 50-316 NUMB OTHER FACILITIESINVOLVED(6)
OPERATING MODE (9)
POWER LEVEL(10) 00 20.2201 (b) 20.2203(a)(1) 20.2203(a)(2)(i) 20.2203(a)(2)(v) 20.2203(a)(3)(i) 20.2203(a)(3)(ii) 50.73(a)(2)(i) 50.73(a)(2)(ii) 50.73(a)(2)(iii) 50.73(a)(2)(viii) 50.73(a)(2)(x) 73.71 THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR (I: (Check one or more) (11) 20.2203(a)(2)(ii) 20.2203(a)(2)(iii) 20.2203(a)(2)(iv) 20.2203(a)(4) 50.36(c)(1) 50.36(c)(2)
LICENSEE CONTACT FOR THIS LER (12) 50.73(a)(2)(iv) 50.73(a)(2)(v) 50.73(a)(2)(vii)
OTHER peafy el Abslraol below or M NRC Form 366A NAME Mr. Frank Pisarsky, Mechanical component Engineering Supervisor TELEPKONE NUMBER(Irldvde Area Code) 616/465-5901, x2607 COMPLETE ONE LINE FOR EACH COMPONENT FAILURE DESCRIBED IN THIS REPORT (13)
CAUSE
SYSTEM COMPONENT MANUFACTURER REPORTABLE TO NPRDS
CAUSE
SYSTEM COMPONENT MANUFACTURER REPORTABLE TO NPRDS SUPPLEMENTAL REPORT EXPECTED (14)
YES (IfYes, complete EXPECTED SUBMISSION DATE)
X NO EXPECTED SUBMISSION DATE (15)
M NTH DA Abstract (Limitto 1400 spaces, i.e., approximately 15 single-spaced typewritten lines) (16)
On January 12, 1998, with Unit 1 in Mode. 5, a damaged ice condenser ice basket was removed from the Unit 1 ice condenser and a scoping test was performed to determine its ability to structurally withstand design basis loads. The scoping test results showed that the damaged ice basket failed with plastic deformation under less than design basis loads. This event was reported via ENS on January 12, 1998 at 1545 hours0.0179 days <br />0.429 hours <br />0.00255 weeks <br />5.878725e-4 months <br /> EST under 10CFR50.72(b)(2)(i), as an unanalyzed condition and a condition outside the plant's design basis.
Prior to and subsequent to this notification, several forms of ice basket damage were identified including damaged upper rims, missing or tom ligaments, dents and folds.
This LER is therefore submitted in accordance with 10CFR50.72(a)(2)(i).
The root cause of this condition has been attributed to inadequate control of contractors, and inappropriate maintenance and surveillance practices that resulted in damage to the ice baskets.
A decision was made to completely thaw both~nits ice condensers in order to address a variety of issues identified during the current unit outages, including basket damage.
The thaw of both units'ce condenser has now been completed.
The procedures used to guide maintenance and surveillance activities for the ice condenser are being upgraded and rewritten for use within the Maintenance department,
'o whom supervisory oversight responsibility has been transferred.
The types of ice basket damage observed during the recent inspections has been consistent with the types of damage described in the previous revision of this LER. Therefore, the conclusion that the ice baskets would have functioned to prevent containment overpressure remains valid, and.the safety significance of the condition minimal.
NRC FORM 366 (4-95)Q (4-95)
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME (1)
Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 50-315 YEAR 98 LER NUMBER (6)
SEQUENTIAL NUMBER 008 REVISION NUMBER 02 PAGE (3) 2of6 TEXT (ifmole spaceis tequited, use additional copies ofNRC Form (366A) (17)
CONDITIONS PRIOR TO OCCURRENCE Unit 1 was in Mode 5, Cold Shutdown Unit 2 was in Mode 5, Cold Shutdown
DESCRIPTION OF EVENT
On January 12, 1998, with Unit 1 in Mode 5, a damaged ice condenser ice basket was removed from the Unit 1 ice condenser and a scoping test was performed to determine its.ability to structurally withstand design basis loads. The scoping test results showed that the damaged ice basket failed with plastic deformation under less than design basis loads.
This event was reported to the NRC on January 12, 1998 as an unanalyzed condition. Prior to and subsequent to this notification, several forms of ice basket damage were identified including damaged upper rims, missing or tom ligaments, dents and folds.
Each ice condenser consists of 24 bays containing 81 ice baskets per bay, covering an arc of 300 degrees in the containment structure.
Each ice basket is approximately 12 inches across and 48 feet long, filled with borated ice. To perform their design basis function, the ice baskets and columns are required to withstand design loads to ensure they do not eject upward out of the ice bed and open up bypass flow routes, or impact and damage other ice condenser equipment, or eject out of the ice condenser and become a missile inside containment.
The baskets are designed to not collapse causing adjacent or additional ice basket columns to collapse, resulting in excessive flow passageway
- blockage, bypass flow routes, or undefinable heat transfer geometry.
During the current outages, damage was identiTied to ice condenser ice baskets during tours of the ice condenser.
Damage noted on ice baskets includes damaged top rims, tom/missing ligaments, dents and folds. Folds are considered to be the most significant damage, a result of the basket material undergoing plastic deformation in compression.
The thaw of the Unit 1 and Unit 2 ice condensers has been completed.
To date over 33 percent of the ice baskets in the Unit 1 ice condenser have been inspected, and repair /replacement activities are ongoing. The type of ice basket damage observed during these inspections has been consistent with the types of damage previously identified. Inspection and repairs for the Unit 2 ice condenser has not yet started, but it is anticipated that the same type of damage willbe found.
CAUSE OF EVENT
The observed damage can be attributed to improper handling of baskets during maintenance and surveillance activities.
Because damage occurred during basket maintenance and surveillance activities, and contract personnel perform the, majority of this work, inadequate control of contractors is considered a primary cause for the noted condition. Contributors to this cause include ineffective training for contract personnel and inadequate supervisory oversight by utilitypersonnel.
Improper surveillance practices was another contributor, since some of the more significant basket damage occurred during attempts to move baskets from beneath during weighing.
Damaged top rims and folds in the baskets most likely occurred during the baskets weighing process.
The process of weighing baskets requires liftingthe basket from the top rim with a weigh rig. Over time, some baskets have become frozen in place.
In order to free. frozen baskets forweighing, various techniques have been used.
One technique used in the past was "jacking" of baskets from the bottom as the basket was pulled from above.
Failure to control the jacking in the event the basket remained frozen sometimes resulted in deformation of the basket and produced a fold in the ligaments near the basket bottom. The practice ofjacking baskets from the bottom was discontinued several years ago to preclude further basket damage.
I(4-95)
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME(1)
Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) ~
50-315 YEAR SEQUENTIAL NUMBER "REVISION NUMBER LER NUMBER (6)
PAGE (3) 3of6 98 008 02 TEXT (Ifmore spaceis required, use additional copies ofNRC Form (366A) (17)
CAUSE OF EVENT (cont'd)
Other types of damage can also occur to baskets during the weighing process ifnot carefully controlled. As previously noted, the weighing process requires liftingthe basket by pulling from the top rim. Although limits are set on maximum lift forces, top rim damage can quickly occur ifliftforces are not closely monitored, or ifloading is applied asymmetrically.
Damage can also occur during the weighing process when a frozen basket is exercised in an attempt to free it.
Still other observed damage is considered to be the result of ice basket mishandling or inappropriate maintenance activities. Two examples of this type damage include inward dents in areas of basket ligaments and tom ligaments.
Dents probably occurred during basket installation, or perhaps during clearing of flow passages.
Tears in ligaments are most likely the result of prolonged contact with a pneumatic vibrator, which is used for emptying of ice baskets.
The vast majority of ice condenser work has been performed in the past by a contract labor force, with the contract being administered by the Engineering department and specifically, the System Engineer.
The contract administration responsibility was in addition to the System Engineer's normal role of management of the technical scope of the ice condenser work and analysis of surveillance test results.
This broad scope of responsibilities allowed only minimal time for field oversight of the contractor.
Steps were not taken to make other utility personnel available for oversight of the contract labor force. Therefore, field supervision for contract workers was largely provided by contract supervisory personnel rather than by utility personnel.
During the current outages, steps were taken to transfer responsibility for oversight of the ice
'ondenser labor force to the maintenance department, which retains personnel skilled in the supervision of production labor. These steps are aimed at addressing issues with poor control of contractors.
The System Engineer historically administers a training program to the ice condenser contract personnel.
This training includes guidance on basket weighing techniques and on appropriate use of tools to avoid damage to baskets.
- However, this tiaining has apparently not been effective in preventing basket damage.
Steps are being taken to overhaul this training, in part to reinforce appropriate techniques to preclude various types of ice basket damage.
Finally, the lack of a definition ofwhat constitutes "detrimental damage" was also viewed as a contributor, since there was no benchmark for personnel to gage whether observed damage resulted in an unacceptable condition. Simplistically, any'asket damage sufficient to challenge the basket's ability to carry design. loads is considered detrimental damage Documentation of damage to Cook Plant ice baskets in previous corrective action documents provides evidence that the organization was able to recognize damaged ice baskets as a condition adverse to quality.
In fact, the Technical Specifications (T/S) require periodic inspection of a sample of ice baskets for detrimental damage.
However, a definition of detrimental damage does not exist, other than wording in T/S 4.6.5.1.d, which refer to detrimental damage as "structural wear, cracks, corrosion or other damage."
This lack of an objective definition may have contributed to confusion about the significance of the damaged ice baskets.
ANALYSISOF THE EVENT On January 12, 1998, at 1545 hours0.0179 days <br />0.429 hours <br />0.00255 weeks <br />5.878725e-4 months <br /> EST an ENS notification was made regarding damaged ice baskets in accordance with 10CFR50.72(b)(2)(i), as an unanalyzed condition and a condition outside the plant's design basis, following receipt of a scoping load test result on a damaged ice basket with buckling damage near the basket bottom rim. Baskets with buckling damage are considered to bound other types of ice basket damage identified during the current outages due to these baskets having undergone plastic deformation.
This LER is submitted in accordance with 10CFR50.73(a)(2)(i).
This test examined the damaged basket's ability to structurally withstand static test loads equivalent to the Operational Basis Earthquake (OBE) and ice basket dead weight loads. The scoping test results showed that the damaged ice basket i(4-95)
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION U.S. NUCLEARREGULATORY COMMISSION FACILITYNAME(1)
Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 50-315 YEAR 98 LER NUMBER (6)
SEQUENTIAL NUMBER 008 REVISION NUMBER 02 PAGE (3) 4of6 TEXT (Ifmote spaceis mquimd, use addilional copies ofNRC Form (366A) (17)
ANALYSISOF THE EVENT (cont'd) failed with plastic deformation under a distributed lateral load of approximately 400 Ibs in conjunction with a compressive load of approximately 2000 lbs. By comparison, WCAP-8304, Stress and Structural Analysis and Testing of Ice Baskets, specifies that the ice basket should be able to withstand a lateral load equivalent to approximately 2400 Ibs distributed over the bottom 6 feet of the basket in conjunction with a compressive vertical load of 4933 lbs. The failure of this basket under less than design loads was considered to be an unanalyzed condition and thus was reported to the NRC per 10CFR50.72.
Approximately 25 baskets in Unit 1 and 45 baskets in Unit 2 are currently know to exhibit similar damage.
The damaged ice baskets were evaluated as to compliance with the design basis, operability and functionality. Several types of ice basket damage were considered, including top rim damage, tom/missing ligaments, dents and folds.
With regard to design basis, the baskets and columns of baskets are designed to withstand certain design loads to provide assurance of ice bed geometry for proper thermal/hydraulic performance of the ice condenser during a LOCAand/or seismic transient events.
To perform their design basis function, the baskets and basket columns are designed to not eject upward out of the ice bed and possibly open up bypass flow routes, or impact and damage other ice condenser equipment, or eject out of the ice condenser becoming a missile inside containment.
Baskets must also not collapse causing adjacent baskets/columns to collapse, resulting in flow passageway blockage, bypass flow routes, or unanalyzed heat transfer geometries.
Top rim damage has been reviewed and determined to not be a condition that would challenge the design basis or make the ice condenser inoperable.
Damage at the top end of the basket column willnot promote the ejection of an ice basket or column from the ice bed or promote detrimental damage at any adjacent ice basket columns, interfacing structures or equipment.
From the aspect of design basis loads, top rim damage may result in some localized deformation, but it willnot cause or promote collapse of that column, or damage adjacent baskets, basket columns, interfacing structures, or equipment.
Baskets with damaged top rims willmeet design basis load conditions and do not represent a challenge to operability or functionality of the ice condenser.
Missing or tom ice basket ligaments are not represented or taken into consideration on any design drawings or documentation.
However, missing ligaments willnot promote the ejection of an ice basket or basket column from the ice bed or promote detrimental damage at any adjacent ice baskets; basket columns, interfacing structures, or equipment.
The ice basket includes substantial margin in its ability to resist tensile loads from potential LOCA blowdown forces.
Ice baskets with missing ligaments willhave reduced structural capacity to carry lateral and compressive loads imposed under design seismic load cases.
The most common locations for missing ligaments are in the mid to upper elevations of the ice basket column due to ice bed maintenance operations with vibrators.
At these higher elevations, the vertical compressive loads are not structurally significant and ifthe basket material were overstressed in combination with lateral loads, it is probable that the basket failure would be a small localized lateral displacement or shift in the basket mesh ligaments around the area of the missing ligaments.
This localized displacement of the ice basket section would not cause the damaged basket to impact on adjacent ice basket columns.
Ice baskets with missing/damaged ligaments are considered to be outside the plant design basis, and equate to inoperability in the sense that the basket damage is detrimental, however, the damage does not result in the ice condenser being incapable of performing its design function to prevent containment overpressure following a high energy line break inside containment.
Dents and folds are considered to be the bounding (worst case) condition when evaluating safety significance.
Ice baskets with dents and folds willhave reduced structural capacity relative to their ability to carry lateral and compressive loads which would be imposed under design basis seismic load cases.
The ice condenser design basis, as described in the FSAR, states that the ice condenser internal structures, including ice baskets, are designed to be capable of withstanding(4-95)
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME(1)
Cook Nuclear Plant Unit 1 DOCKET NUMBER(2)
E 50-315 YEAR 98 LER NUMBER (6)
SEQUENTIAL NUMBER 008 PAGE (3)
REVISION NUMBER 5 of 5 02 TEXT (ifmom spaceis required, use additional copies ofNRC Form (366A) (17)
ANALYSISOF THE EVENT (cont'd) various load combinations including deadweight (D) plus operating basis earthquake (OBE) loads, D+ design basis earthquake (DBE) loads, D+ design basis accident (DBA) loads, and D+ DBE+ DBA loads. As noted previously, a scoping test of a sample damaged basket with test loads less than D+ OBE resulted in a failure of the basket with plastic deformation.
Therefore, the existence of damaged baskets that were unable to withstand design loads represented a
condition outside the design basis.
As noted previously, it is estimated that approximately 25 baskets in the Unit 1 ice condenser and 45 baskets in the Unit 2 ice condenser exhibit similar damage.
Baskets with dents are estimated to be a similar quantity of baskets, with a final quantification to be made following inspections during the current outages.
With regard to operability, both unit's T/S require periodic inspections of ice baskets for "detrimental damage", to demonstrate operability. While the term "detrimental damage" has not been formally defined, damage, which results in a basket's inability to carry design loads, is considered detrimental. Therefore, the existence of these damaged ice baskets is considered to represent an inoperable condition for each ice condenser.
With regard to functionality, ice baskets with folds willhave reduced structural capability relative to their ability to carry lateral and compressive loads, which would be imposed under design basis seismic load cases.
The potential for continued ice basket failure under design basis seismic loading conditions at the fold is a function of the size of the damage, and the weight of the ice in the basket sections above the damage area.
It may be postulated that the displacement of the damaged basket section under a seismic loading may be enough to cause the basket to displace laterally into an adjacent ice basket column. However, since basket sections with folds have been shown to have substantial strength as demonstrated in aforementioned testing (which bounds dents, where plastic deformation has not occurred), and since significant energy would be dissipated in the deformation of the ice basket sheet metal section and, enclosed ice, it is expected that ice basket structural integrity willbe maintained, so as to preclude significant collateral ice basket damage and flow passage geometry degradation.
Because of this and the fact that each ice basket column is supported laterally every six feet in elevation by a structural lattice frame grid, it is highly improbable that a significant domino type failure would occur where the damaged basket collapses into an adjacent basket and so forth. Therefore, ice baskets with dents and folds are considered to be out of the design basis, and inoperable from the standpoint of compliance with the surveillance requirement related to detrimental damage, however, the damage does not result in the ice condenser being incapable of performing its design function to prevent containment overpressure following a high energy line break inside containment.
Evaluation of the different types of damage identified to date supports the conclusion that the safety significance of the condition was minimal, and that the ice condenser was capable of performing its design function.
I
CORRECTIVE ACTIONS
Both unit's ice condensers have been completely thawed to allow inspection of the ice baskets for the purpose of identifying and correcting, by repair or replacement, damaged baskets.
A definition of "detrimental damage" has been developed to serve as a gage forjudging whether observed ice basket damage needs repair. This definition has been incorporated into the special procedure being used to perform the current inspections. The definition willalso be incorporated into design basis documents and procedures for surveillance of the ice condenser.
Damage beyond the, threshold of detrimental damage willbe repaired or replaced.
These actions willbe completed prior to startup for each unit.
'I
'1(4-95)
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION U.S. NUCLEAR REGULATORY COMMISSION FACILITYNAME(1)
Cook Nuclear Plant Unit 1 DOCKET NUMBER(2) 50-315 YEAR LER NUMBER (6)
SEQUENTIAL NUMBER REVISION NUMBER PAGE (3) 6of6 98 008 02 TEXT (lfmote space is tequited, use additional copies ofNRC Form (366A) (17)
CORRECTIVE ACTIONS (cont'd)
After the thaw of each unit's ice condenser, a thorough inspection of ice baskets willbe performed. Although these inspection activities willlikely result in the identification of additional damaged baskets, the types of basket damage under consideration are not expected to change.
This condition is applicable to both units.
Responsibility for oversight of production work - maintenance and surveillance activities - has been transferred from the Engineering department to the Maintenance department.
This willallow personnel skilled in supervising production workers to provide oversight for the ice condenser labor force, including contract labor, ifused in the future.
The procedures used to guide maintenance and surveillance activities for the ice condenser are being upgraded and rewritten for use within the Maintenance department.
The upgraded procedures willcontain improved guidance on maintenance and surveillance activities to preclude future damage to ice baskets.
Ice condenser maintenance procedures are also being revised to require inspection of baskets emptied for maintenance prior to refilling during future outages.
The basket inspection willspecifically include provisions for identifying ice basket damage and correcting damage that exceeds the threshold of detrimental damage.
The training program for ice condenser workers is being upgraded.
The upgraded training willinclude improved guidance on proper techniques to avoid basket damage.
These preventive actions will be in place prior to commencing relevant ice condenser activities during the cUrrent outages on each unit.
FAILEDCOMPONENT IDENTIFICATION Not applicable
PREVIOUS SIMILAREVENTS
None
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000315/LER-1998-001, :on 980104,containment Air Recirculation Sys Flow Testing Results Indicated Condition Outside Design Basis.Caused by Mispositioned Valve Actuator.Corrected Actuator to Valve Orientation |
- on 980104,containment Air Recirculation Sys Flow Testing Results Indicated Condition Outside Design Basis.Caused by Mispositioned Valve Actuator.Corrected Actuator to Valve Orientation
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-002, :on 980108,discovered Several Broken Master Relay (MR) Covers Inside Ssps Logic Cabinet.Caused by Past Practice of Removing MR Covers to Perform Time Response Testing.Replaced All Unnacceptable Ssps MRs |
- on 980108,discovered Several Broken Master Relay (MR) Covers Inside Ssps Logic Cabinet.Caused by Past Practice of Removing MR Covers to Perform Time Response Testing.Replaced All Unnacceptable Ssps MRs
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) | | 05000316/LER-1998-002-01, :on 980224,determined That PORV Inoperability Resulted in Condition Outside Design Basis.Caused by Communication Failure.Procedures Revised |
- on 980224,determined That PORV Inoperability Resulted in Condition Outside Design Basis.Caused by Communication Failure.Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000316/LER-1998-003, :on 980304,two Pressurizer Safety Valves Failed to Lift within Setpoint Tolerance.Caused by Setpoint Drift.Valves Were Retested & Adjustments Were Made to Lower Setpoints |
- on 980304,two Pressurizer Safety Valves Failed to Lift within Setpoint Tolerance.Caused by Setpoint Drift.Valves Were Retested & Adjustments Were Made to Lower Setpoints
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-003, :on 980107,missed Procedure Step Resulted in Esfa & RPS Actuation Occurring.Caused by Personnel Error. Work on Ssps Stopped & High Priority Job Order Initiated to Restore Ssps to Normal |
- on 980107,missed Procedure Step Resulted in Esfa & RPS Actuation Occurring.Caused by Personnel Error. Work on Ssps Stopped & High Priority Job Order Initiated to Restore Ssps to Normal
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000316/LER-1998-004-01, :on 990422,determined That Ice Condenser Bypass Leakage Exceeds Design Basis Limit.Caused by Pressure Seal Required by Revised W Design Not Incorporated Into Aep Design.Numerous Matl Condition Walkdowns & Assessments Made |
- on 990422,determined That Ice Condenser Bypass Leakage Exceeds Design Basis Limit.Caused by Pressure Seal Required by Revised W Design Not Incorporated Into Aep Design.Numerous Matl Condition Walkdowns & Assessments Made
| 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) | | 05000316/LER-1998-004, :on 980319,determined That Ice Condenser Bypass Was Potentially in Excess of Design Basis Limit.Caused by Lack of Understanding.Known Degraded Conditions Resulting in Divider Barrier Pass Being Corrected |
- on 980319,determined That Ice Condenser Bypass Was Potentially in Excess of Design Basis Limit.Caused by Lack of Understanding.Known Degraded Conditions Resulting in Divider Barrier Pass Being Corrected
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-004, :on 980122,discovered That One of Ice Condenser Flow Passages Contained Large Amount of Frost & Ice.Caused by Inadequate Maint & Surveillance Practices.Completed Detailed Mapping & Quantification of Flow Passage Blockage |
- on 980122,discovered That One of Ice Condenser Flow Passages Contained Large Amount of Frost & Ice.Caused by Inadequate Maint & Surveillance Practices.Completed Detailed Mapping & Quantification of Flow Passage Blockage
| 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-004-02, Forwards LER 98-004-02,providing Results of Analyses Performed by W.Ler Is Being Reduced from 7 Pages to 6 Due to Transferring Details of Root Cause Section to Cause of Event, Section | Forwards LER 98-004-02,providing Results of Analyses Performed by W.Ler Is Being Reduced from 7 Pages to 6 Due to Transferring Details of Root Cause Section to Cause of Event, Section | | | 05000315/LER-1998-005, :on 980122,missing Screws from Ice Condenser Ice Basket Coupling Rings Resulted in Potentially Unanalyzed Condition.Caused by Failure in Shear Due to Overload During Basket Weighing Process.Melted Out Condensers |
- on 980122,missing Screws from Ice Condenser Ice Basket Coupling Rings Resulted in Potentially Unanalyzed Condition.Caused by Failure in Shear Due to Overload During Basket Weighing Process.Melted Out Condensers
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000316/LER-1998-005-01, :on 980715,potential for HELB to Degrade Component Cooling Water Sys Was Noted.Investigation & Analysis of Signficance of Event Is Continuing.Method May Be Developed to Protect CCW Pump Area |
- on 980715,potential for HELB to Degrade Component Cooling Water Sys Was Noted.Investigation & Analysis of Signficance of Event Is Continuing.Method May Be Developed to Protect CCW Pump Area
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-006, :on 980225,ice Basket Weighing Option Resulted in Potential Unanalyzed Condition Due to Lack of Technical Basis for Option.Caused by Failure to Maintain Design Basis for Ice Condenser.Revised Plant Procedure |
- on 980225,ice Basket Weighing Option Resulted in Potential Unanalyzed Condition Due to Lack of Technical Basis for Option.Caused by Failure to Maintain Design Basis for Ice Condenser.Revised Plant Procedure
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(b)(2)(ii) | | 05000315/LER-1998-007, :on 980211,ice Condenser Weights Used to Determine TS Compliance Were Not Representative.Caused by Mgt Methods.Ice Condensers for Both Units Will Be Melted Out & Reloaded W/Fresh Ice |
- on 980211,ice Condenser Weights Used to Determine TS Compliance Were Not Representative.Caused by Mgt Methods.Ice Condensers for Both Units Will Be Melted Out & Reloaded W/Fresh Ice
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000316/LER-1998-007-01, :on 981106,high Energy Line Break Effects in Auxiliary FW Sys Was Noted.Cause of Event Is Under Investigation & Will Be Completed by 990220.Updated LER Will Be Submitted by 990310.With |
- on 981106,high Energy Line Break Effects in Auxiliary FW Sys Was Noted.Cause of Event Is Under Investigation & Will Be Completed by 990220.Updated LER Will Be Submitted by 990310.With
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) | | 05000315/LER-1998-008, :on 980112,inadequate Contractor Control During Maint & Surveillance Activities Resulted in Ice Basket Damage.Procedures Used to Guide Maint & Surveillance Activities Have Been Upgraded & Rewritten |
- on 980112,inadequate Contractor Control During Maint & Surveillance Activities Resulted in Ice Basket Damage.Procedures Used to Guide Maint & Surveillance Activities Have Been Upgraded & Rewritten
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000316/LER-1998-008, :on 980112,damaged Ice Condenser Ice Basket Removed from Unit 1 Ice Condenser.Caused by Inadequate Control of Contractors & Inappropriate Maint.Damage Beyond Threshold Will Be Repaired & Replaced |
- on 980112,damaged Ice Condenser Ice Basket Removed from Unit 1 Ice Condenser.Caused by Inadequate Control of Contractors & Inappropriate Maint.Damage Beyond Threshold Will Be Repaired & Replaced
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) | | 05000315/LER-1998-009, :on 980217,HR SR Not Being Met Resulted in Condition Prohibited by Ts.Caused by Inadequate Surveillance Procedure.Procedures Revised |
- on 980217,HR SR Not Being Met Resulted in Condition Prohibited by Ts.Caused by Inadequate Surveillance Procedure.Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) | | 05000315/LER-1998-010, :on 980303,ice Condenser Intermediate Deck Doors Structural Discrepancies Were Noted.Caused by Failure to Follow Procedures.Removed All Intermediate Deck Door Frames & Support Beams & Reassembling Parts |
- on 980303,ice Condenser Intermediate Deck Doors Structural Discrepancies Were Noted.Caused by Failure to Follow Procedures.Removed All Intermediate Deck Door Frames & Support Beams & Reassembling Parts
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-011, :on 980305,steel Containment Liner Pitting Was Is Excess of Design.Caused by Lack of Procedural Controls. Seals Were Removed,Containment Liner Plate Was Prepared & Coated & New Seals Applied |
- on 980305,steel Containment Liner Pitting Was Is Excess of Design.Caused by Lack of Procedural Controls. Seals Were Removed,Containment Liner Plate Was Prepared & Coated & New Seals Applied
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-012, :on 980305,discovered That 1/4 Inch Particulate Retention Requirement Had Not Been Maintained in Containment Recirculation Pump.Caused by Incompleted Design Change.Will Correct Condition Under New Design Change |
- on 980305,discovered That 1/4 Inch Particulate Retention Requirement Had Not Been Maintained in Containment Recirculation Pump.Caused by Incompleted Design Change.Will Correct Condition Under New Design Change
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-013, :on 980306,improper Splice Configurations for Power Operated Relief Valve Limit Switches Resulted in Unanalyzed Condition.Caused by Inadequate Guidance in Installation Documents.Evaluation Performed |
- on 980306,improper Splice Configurations for Power Operated Relief Valve Limit Switches Resulted in Unanalyzed Condition.Caused by Inadequate Guidance in Installation Documents.Evaluation Performed
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-014, :on 980310,determined That Plant Had Operated in Unanalyzed Condition.Caused by Inadequate Interface with W Re Assumptions Used in Safety Analysis.Will Revise Functional Restoration Procedure FRZ-1.With |
- on 980310,determined That Plant Had Operated in Unanalyzed Condition.Caused by Inadequate Interface with W Re Assumptions Used in Safety Analysis.Will Revise Functional Restoration Procedure FRZ-1.With
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded | | 05000315/LER-1998-014-03, Forwards LER 98-014-03, Response to High-High Containment Pressure Procedure Not Consistent with Analysis of Record. Revised Info Marked by Sidebars in Right Hand Margin. Commitments Made by Util,Listed | Forwards LER 98-014-03, Response to High-High Containment Pressure Procedure Not Consistent with Analysis of Record. Revised Info Marked by Sidebars in Right Hand Margin. Commitments Made by Util,Listed | | | 05000315/LER-1998-015, :on 980312,ice Weight Requirements Potentially Were Not Met Due to Nonconservative Assumption in Software Program.Update to Interim LER Will Be Issued by 980513 |
- on 980312,ice Weight Requirements Potentially Were Not Met Due to Nonconservative Assumption in Software Program.Update to Interim LER Will Be Issued by 980513
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(s)(2) | | 05000315/LER-1998-016, :on 980323,re non-safety Related Cables Routed to Safety Related Equipment.Lers 98-016-00 & 98-016-01 Retracted |
- on 980323,re non-safety Related Cables Routed to Safety Related Equipment.Lers 98-016-00 & 98-016-01 Retracted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-017, :on 980327,debris Was Found in Sample Ice from Ice Condenser Sys.Caused by Poor Work Practices.Ice Condenser Has Been Completely Thawed & Inspection,Repair & Refurbishment Activities Have Begun |
- on 980327,debris Was Found in Sample Ice from Ice Condenser Sys.Caused by Poor Work Practices.Ice Condenser Has Been Completely Thawed & Inspection,Repair & Refurbishment Activities Have Begun
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-018, :on 980505,use of RCP Seals as Alternate Boron Injection Flow Path Resulted in Unanalyzed Condition.Caused by Maintaining Temp Above Recommended Max Temp.Westinghouse Has Provided Technical Input on Issue |
- on 980505,use of RCP Seals as Alternate Boron Injection Flow Path Resulted in Unanalyzed Condition.Caused by Maintaining Temp Above Recommended Max Temp.Westinghouse Has Provided Technical Input on Issue
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-019-02, Forwards LER 98-019-02,which Provides Plant Test Data Gathered to Determine Error Associated W/Electric H Recombiner Temp Measurement Circuits.Changes to LER Are Marked W/Sidebar | Forwards LER 98-019-02,which Provides Plant Test Data Gathered to Determine Error Associated W/Electric H Recombiner Temp Measurement Circuits.Changes to LER Are Marked W/Sidebar | | | 05000315/LER-1998-019, :on 980320,determined That Electric Hydrogen Recombiner TS Surveillance Requirement 4.6.4.2.b.1 Was Not Met.Caused by Design Deficiency Due to Inadequate Design Change Mgt.Revised Procedures |
- on 980320,determined That Electric Hydrogen Recombiner TS Surveillance Requirement 4.6.4.2.b.1 Was Not Met.Caused by Design Deficiency Due to Inadequate Design Change Mgt.Revised Procedures
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-020, :on 980408,noted Failure to Include Sodium Hydroxide in W Border Computer Program Used to Determine Ph in Containment Sump.Cause Indeterminate.Updated LER Will Be Submitted by 981001 |
- on 980408,noted Failure to Include Sodium Hydroxide in W Border Computer Program Used to Determine Ph in Containment Sump.Cause Indeterminate.Updated LER Will Be Submitted by 981001
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-021, :on 980311,determined That Oil Pans Not Installed on RCP Motors Resulted in App R Noncompliance. Caused by Failure to Fully Implement App R Requirements.Will Updgrade Oil Leak Collection Sys |
- on 980311,determined That Oil Pans Not Installed on RCP Motors Resulted in App R Noncompliance. Caused by Failure to Fully Implement App R Requirements.Will Updgrade Oil Leak Collection Sys
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-022, :on 980415,postulated Failure of SAT N Regulator Was Noted.Caused by Failure to Perform Adequate SE for Procedure rev.10CFR50.59 Program Has Been Upgraded to Meet Current Industry Standards.With |
- on 980415,postulated Failure of SAT N Regulator Was Noted.Caused by Failure to Perform Adequate SE for Procedure rev.10CFR50.59 Program Has Been Upgraded to Meet Current Industry Standards.With
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-023, :on 980416,potential Failure Due to Cross Train Routing of non-safety Related Cables Was Noted.Ler 98-023-00 & 98-023-01,retracted |
- on 980416,potential Failure Due to Cross Train Routing of non-safety Related Cables Was Noted.Ler 98-023-00 & 98-023-01,retracted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-024, :on 980417,allegation Concerning Accuracy of Ice Basket Weights Occurred.Allegation Has Been Investigated & Results of Investigation Will Be Provided to NRC by 980522 |
- on 980417,allegation Concerning Accuracy of Ice Basket Weights Occurred.Allegation Has Been Investigated & Results of Investigation Will Be Provided to NRC by 980522
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-025, :on 980424,plant Personnel Determined That Surveillance Requirements of Tech Specs 4.6.5.1.b.3 Were Not Met.Caused by Lack of Attention to Detail.Procedures Revised |
- on 980424,plant Personnel Determined That Surveillance Requirements of Tech Specs 4.6.5.1.b.3 Were Not Met.Caused by Lack of Attention to Detail.Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-026, :on 980430,TS SR 4.6.5.1.b.2 Was Not Met.Caused by Failure to Accurately Transfer SR Into Plant Procedures. Software Used to Support Ice Condenser Surveillance Program Will Either Be Revised or Replaced |
- on 980430,TS SR 4.6.5.1.b.2 Was Not Met.Caused by Failure to Accurately Transfer SR Into Plant Procedures. Software Used to Support Ice Condenser Surveillance Program Will Either Be Revised or Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) | | 05000315/LER-1998-027, :on 980505,discovered Debris of Unknown Origin in West Containment Spray Header.Cause Indeterminate. Evaluation of Condition in Progress & Updated LER Will Be Submitted |
- on 980505,discovered Debris of Unknown Origin in West Containment Spray Header.Cause Indeterminate. Evaluation of Condition in Progress & Updated LER Will Be Submitted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-028, :on 980513,determined That TS Surveillance Requirements Not Met Due to Lack of Understanding of Staggered Test Basis. Caused by Lack of Specific Training. Periodic Change of Nuclear Plant Maint Sys |
- on 980513,determined That TS Surveillance Requirements Not Met Due to Lack of Understanding of Staggered Test Basis. Caused by Lack of Specific Training. Periodic Change of Nuclear Plant Maint Sys
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) | | 05000315/LER-1998-029, :on 980422,SFP Ventilation Sys Was Noted Inoperable.Caused by Design Deficiency.Safety Evaluation Successfully Performed & Appropriate Surveillance Testing Completed |
- on 980422,SFP Ventilation Sys Was Noted Inoperable.Caused by Design Deficiency.Safety Evaluation Successfully Performed & Appropriate Surveillance Testing Completed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-029-01, Forwards LER 98-029-01, Fuel Handling Area Ventilation Sys Inoperable Due to Original Design Deficiency. Supplemental Rept Represents Extensive Rev to Original LER & Replaces Rept in Entirely.Commitment Listed | Forwards LER 98-029-01, Fuel Handling Area Ventilation Sys Inoperable Due to Original Design Deficiency. Supplemental Rept Represents Extensive Rev to Original LER & Replaces Rept in Entirely.Commitment Listed | | | 05000315/LER-1998-030, Re Incorrect Installation of Containment Spray Heat Exchanger.Ler 98-030-00 Retracted. with | Re Incorrect Installation of Containment Spray Heat Exchanger.Ler 98-030-00 Retracted. with | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-031, :on 980610,potential Common Mode Failure of RHR Pumps Were Noted.Caused by Inaccurate Values.Accurate Miniflow Numbers Have Been Determined by Flow Testing |
- on 980610,potential Common Mode Failure of RHR Pumps Were Noted.Caused by Inaccurate Values.Accurate Miniflow Numbers Have Been Determined by Flow Testing
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-031-01, Forwards LER 98-031-01,re Potential Common Mode Failure of RHR Pumps Due to Use of Inaccurate Values.Commitment Made by Util,Listed | Forwards LER 98-031-01,re Potential Common Mode Failure of RHR Pumps Due to Use of Inaccurate Values.Commitment Made by Util,Listed | | | 05000315/LER-1998-032, Forwards LER 98-032-00,originally Due on 980723.Additional Seven Days to Submit LER Was Granted by B Burgess of Region III | Forwards LER 98-032-00,originally Due on 980723.Additional Seven Days to Submit LER Was Granted by B Burgess of Region III | 10 CFR 21.21(c)(3)(ii) | | 05000315/LER-1998-033, :on 980611,H Recombiner Wattmeter Circuit TS SR Was Not Met.Caused by Inadequate TS SR Work Practices. Lessons Learned Document Was Issued to All Maint Personnel Involved W/Writing Surveillance Procedures |
- on 980611,H Recombiner Wattmeter Circuit TS SR Was Not Met.Caused by Inadequate TS SR Work Practices. Lessons Learned Document Was Issued to All Maint Personnel Involved W/Writing Surveillance Procedures
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) | | 05000315/LER-1998-034, :on 980623,flow Rates to Containment Spray Headers Were Potentially Lower than Design Basis Values. Declared Containment Spray Sys,Inoperable.Update Will Be Submitted by 981015 |
- on 980623,flow Rates to Containment Spray Headers Were Potentially Lower than Design Basis Values. Declared Containment Spray Sys,Inoperable.Update Will Be Submitted by 981015
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-035, :on 980702,identified That Potentially Impacted Ability of Shock Absorbing Bumpers to Perform Intended Functions.Caused by Poor Work Practices.Bumpers Will Be Replaced by Newer Design Shock Absorber |
- on 980702,identified That Potentially Impacted Ability of Shock Absorbing Bumpers to Perform Intended Functions.Caused by Poor Work Practices.Bumpers Will Be Replaced by Newer Design Shock Absorber
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-036, :on 980723,discovered That Flow Indicator Had Not Been Calibr at TS Required Frequency.Caused by Inadequate Work Practices.Action Request Has Been Written to Calibr Component on Refueling Outage Basis |
- on 980723,discovered That Flow Indicator Had Not Been Calibr at TS Required Frequency.Caused by Inadequate Work Practices.Action Request Has Been Written to Calibr Component on Refueling Outage Basis
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000315/LER-1998-037-01, Forwards LER 98-037-01,representing Extensive Rev to Original LER & Replacing Rept in Entirety.Listed Commitments Identified in Submittal | Forwards LER 98-037-01,representing Extensive Rev to Original LER & Replacing Rept in Entirety.Listed Commitments Identified in Submittal | | | 05000315/LER-1998-037, :on 980812,ice Condenser Bypass Leakage Exceeds Design Basis Limit of 5 Square Feet Occurred.Caused by Lack of Understanding of Design Basis of Containment as Sys. Procedure Will Be Developed to Guide Insp.With |
- on 980812,ice Condenser Bypass Leakage Exceeds Design Basis Limit of 5 Square Feet Occurred.Caused by Lack of Understanding of Design Basis of Containment as Sys. Procedure Will Be Developed to Guide Insp.With
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
|