Finding | |
|---|---|
| Title | Incorrect Auxiliary Feedwater Mission Time |
| Description | The inspectors identified a finding of very low safety significance and associated NCV of with Title 10 of the Code of Federal Regulations (CFR) Part 50, Appendix B, Criterion III, Design Control. Specifically, the licensee failed to ensure that regulatory requirements and design bases were correctly translated into specifications and procedures, in that the licensee used an incorrect mission time for the turbine driven auxiliary feedwater (TDAFW) pump to determine operability. The licensee developed a procedure that permitted continued operability of the TDAFW pump without room ventilation provided room temperature remained below 104 F. The underlying engineering document assumed TDAFW pump mission time was 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />; however, this assumption was not supported by current license bases documents. This condition violates 10 CFR 50 Appendix B Criterion III, which requires licensees to establish measures to assure that applicable regulatory requirements and the design bases, as defined in 10 CFR 50.2 and as specified in the license application, for those systems structures and components to which the Appendix applies, are correctly translated onto specifications, drawings, procedures and instructions. The licensee has since restored the room coolers to an operable status, thus, no current safety concern exists. The licensee has entered the condition into the corrective action program (CAP). The licensees use of an incorrect mission time was a performance deficiency that warranted a significance review. Using IMC 0612 appendix B dated September 7, 2012, the inspectors determined that the finding was more than minor because it was associated with the Mitigating System cornerstone objective to ensure the availability, reliability and capability of systems that respond to initiating events and adversely affected the attribute of design control. Specifically, the licensee applied an incorrect mission time when determining room temperatures to ensure TDAFW pump operability. Using IMC 0609 Appendix A, Exhibit 21, dated June 19, 2012, the inspectors answered no to Questions A. 1 thru 4. In particular, control room logs document about 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> with the TDAFW room ventilation not functioning; therefore the inspectors determined that the pump would not have been inoperable for longer than the 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> completion time in technical specifications. The inspectors also identified a cross cutting aspect of H.14, conservative bias, in the human performance area. |
| Site: | Cook |
|---|---|
| Report | IR 05000315/2016001 Section 4OA5 |
| Date counted | Mar 31, 2016 (2016Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | B Jose D Reeser J Ellegood J Mancuso K Riemer M Garza R Walton T Taylor |
| Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control Technical Specification - Procedures Technical Specification |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |