a suun SACRAMENTO MUNICIPAL UTILITY DISTRICT O 6201 S Street, Box 15830, Sacramento, California 95813; (916) 452 3211 August 7, 1981 m

.2

_i R H ENGELKEN, DIRECTOR

__, 9j lG REGION V 0FFICE OF INSPECTION & ENFORCEMENT y

U S NUCLEAR REGULATORY GMMISSi')N 1990 N CALIFORNIA BLVL, 4

UALNUT CREEK PLAZA, SUITE 202 WALNUT CREEK CA 94596 q

DOCKET NO. 50-312 LICENSE NO. DPR-54 REPORTABLE OCCURRENCE 81-37 In accordance with Technical Specification Section 6.9.4.2.b, the Sacramento Municipal Utility District hereby submits a thirty-day repc.

  • af Reportable Occurrence 81-37 On July 7, 1981, during performance of SP 205.07A, Isolation Valve Surveillance Test, HV-20593, the OTSG-A Sample Line isolation Valve closed in 12.9 seconds, exceeding the allowable limit of 12 seconds.

In accordance with Technical Specification Section 3.6.6, HV-20593 was closed until repai rs could be made.

The valve is a pneumatically operated globe valve, Fisher Governor model 667-ES, with an Asco controller.

Foreign material, which appeared to be desiccant f rom the ai r driers, was found in the air discharge port.

When it was removed, the valve was retested and closed in 10.5 seconds.

This and all other safety related, pneumat-ically operated valves will continue to be monitored and tested to assure proper operation.

The reactor operated at full power, with no transients or power reductions associated with this event.

}

hn fia t t i moe

\\

h Assistant Genera? Manager I

l and Chief Engineer cc-l&E Washington (30)

MIPC (3)

EPRI-NSAC k

8108170386 810807 PDR ADOCK 05000312 S

PDR A T4 LLECTVIC JY37[M

,EFVINu Y2Rt TH1N CJ.000 IN THi HEART OF CALit0RNiA