Finding | |
|---|---|
| Title | Repetitive Molded Case Circuit Breaker Failures |
| Description | A finding of very low significance and associated non-cited violation of Title 10 of the Code of Federal Regulations (CFR) 50.65(a)(3) was identified by the inspectors for the failure to incorporate industry operating experience into preventive maintenance activities when practical to do so. Specifically, the failure to incorporate the industry operating experience resulted in multiple molded case circuit breaker (MCCB) failures that could have been prevented by implementing an MCCB cycling program. The need to cycle MCCBs was identified in industry operating experience as well as the vendor\'s instructions for the breakers. The licensee was performing an apparent cause evaluation which was still in-progress at the conclusion of the inspection period. Initial corrective actions included scheduling the MCCBs for the breaker cycling maintenance activity. This finding was determined to be of greater than minor significance because it was associated with the Protection Against External Factors attribute of the Initiating Events Cornerstone and adversely affected the cornerstone objective to limit the likelihood of those events, such as fire, that challenge critical safety functions during shutdown as well as power operations. Specifically, the lack of a cycling program for safety-related MCCBs resulted in breakers remaining in the on position after an overcurrent condition. The inspectors determined the finding had very low safety significance (Green) because the breakers and associated cabling did not significantly affect safe shutdown defense-in-depth strategies and the finding did not involve a design or qualification deficiency, did not represent a loss of system safety function, did not represent a loss of Technical Specification equipment for greater than its allowed outage time, and did not affect risk significant equipment per 10 CFR 50.65. This finding has a cross-cutting aspect in the area of human performance, work control, because the licensee did not emphasize the need for work groups to communicate, coordinate, and cooperate with each other during activities in which interdepartmental coordination is necessary to assure plant and human performance |
| Site: | Kewaunee |
|---|---|
| Report | IR 05000305/2011004 Section 1R12 |
| Date counted | Sep 30, 2011 (2011Q3) |
| Type: | NCV: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | M Kunowski R Krsek K Barclay R Edwards L Rodriguez |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |
Finding - Kewaunee - IR 05000305/2011004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Kewaunee) @ 2011Q3
Self-Identified List (Kewaunee)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||