Finding | |
|---|---|
| Title | Failed Standoffs Result in an Inoperable Train of Shield Building Ventilation |
| Description | A finding of very low safety significance and associated non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, was identified by inspectors for the failure to have and follow adequate procedures for the evaluation and installation of components in shield building ventilation (SBV) train A. Specifically, the licensee failed to have adequate procedures to direct the completion of a subcomponent classification evaluation (SCE) and prevent nonsafety-related parts from being installed in safety-related applications; have torque specifications for the standoffs (spacers for circuit cards) in the work instructions; and properly accomplish the SCE procedure when evaluating the standoffs. The licensees initial short-term corrective actions removed the installed standoffs from both trains. The licensee also performed an extent-of-condition looking at previously completed item equivalency evaluations to determine if an SCE was needed or missing for newly installed components. The finding was determined to be more than minor because the finding was associated with the Barrier Integrity Cornerstone attribute of procedure quality, and adversely affected the cornerstone objective of providing reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events. Specifically, the licensee failed to have and follow adequate procedures which led to the failure of SBV train A. The inspectors determined that this was a type B containment finding since it was related to a degraded condition that had potential important implications for the integrity of the containment, without affecting the likelihood of core damage. The inspector evaluated the finding using the SDP in accordance with IMC 0609, Appendix H, Containment Integrity SDP, Table 4.1, and determined that the finding did not relate to a containment structure, system, and component, nor containment status that had an impact on large early release frequency. Because of this, the issue screened as Green, using the flowchart in Figure 4.1. The finding has a cross-cutting aspect in the area of problem identification and resolution, corrective action program, because the licensee failed to thoroughly evaluate problems such that the resolutions address causes and extent-of-conditions, as necessary. This includes properly classifying, prioritizing, and evaluating for operability and reportability conditions adverse to quality. This also includes, for significant problems, conducting effectiveness reviews of corrective actions to ensure that the problems are resolved. Specifically, the licensee failed to properly evaluate and identify the cause of the SBV train A failure and produce a resolution that addressed the cause (P.1(c)). |
| Site: | Kewaunee |
|---|---|
| Report | IR 05000305/2011003 Section 1R15 |
| Date counted | Jun 30, 2011 (2011Q2) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | R Winter J Cassidy M Kunowski R Krsek K Barclay K Carrington |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Kewaunee - IR 05000305/2011003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Kewaunee) @ 2011Q2
Self-Identified List (Kewaunee)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||