05000298/FIN-2009007-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Follow Procedure Results in Inadequate Operability Determinations of Degraded Agastat Timer Relays |
| Description | The team identified a noncited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, for the licensees failure to follow the requirements of Procedure ENN OP 104, Operability Determinations. Specifically, between 2005 and 2009 operations personnel failed to perform adequate operability determinations of degraded and potentially degraded conditions associated with essential Agastat time delay relays with internal foreign material contamination that either needed an immediate operability determination or needed more information to reasonable assurance of operability. This included a potential degraded condition of the installed essential Relay 27X15-1G that the inspection team noted had a trend similar to relays that had previously failed with internal foreign material contamination. The licensee documented this condition with CR-CNS-2009-02844 and replaced the potentially degraded relay ten days later. This finding is more than minor because it affected the reliability objective of the equipment performance attribute of the Mitigating Systems Cornerstone to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). The finding was determined to have a very low safety significance because the finding did not result in a loss of system safety function, an actual loss of safety function of a single train for greater than its Technical Specification allowed outage time, or screen as potentially risk significant due to a seismic, flooding, or severe weather initiating event. The cause of this finding is related to the problem identification and resolution crosscutting aspect associated with the corrective action program because licensee personnel failed to thoroughly evaluate conditions adverse to quality and perform meaningful operability determinations P.1(c) |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2009007 Section 4OA2 |
| Date counted | Jun 30, 2009 (2009Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | G Werner C Osterholtz S Freeman M Chambers |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Cooper - IR 05000298/2009007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2009Q2