05000286/FIN-2008002-03
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Report Under 10 CFR 50.72(B)(2)(V), the Loss of Pressurizer Heaters |
Description | The inspectors identified a Severity Level IV, non-cited violation of 10 CFR 50.72(b)(3)(v) because Entergy did not report the loss of the 31 backup pressurizer heater group. Entergy submitted a licensee event report and entered the issue into their corrective action program. This finding was evaluated using the traditional enforcement process since the failure to make a required report could adversely impact the NRCs ability to carry out its regulatory mission. The failure to report was entered into Entergy\'s corrective action program as CR-IP3-2008-00879, and Entergy is currently drafting a licensee event report regarding this event. Since this violation has been characterized as a Severity Level IV violation, and has been entered into Entergys corrective action program, it is being treated as a non-cited violation in accordance with Section VI of the NRC Enforcement Policy. The inspectors determined that this finding had a cross-cutting aspect in the area of Human Performance, in that Entergy did not make risk significant decisions using a systematic process. Specifically, the Unit 3 current licensing and design bases contained the necessary information to reach an appropriate decision regarding compliance with applicable regulations. (H.1.(a) |
Site: | Indian Point |
---|---|
Report | IR 05000286/2008002 Section 1R15 |
Date counted | Mar 31, 2008 (2008Q1) |
Type: | TEV: Severity level IV |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.15 |
Inspectors (proximate) | A Koonce E Cobey P Cataldo S Barr |
CCA | , |
INPO aspect | DM.1 |
' | |
Finding - Indian Point - IR 05000286/2008002 | |||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2008Q1
| |||||||||||||||||||||||||||||||||||||||||||||||||