05000280/FIN-2011003-04
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Licensee-Identified Violation |
Description | Licensee Technical Specification, 3.1.B.3, requires, in part, that the spray shall not be used if the temperature difference between the pressurizer and the spray fluid is greater than 320 deg F. Contrary to this, the licensee identified that this specification was exceeded on Unit 1 on April 17, 2011. The licensee created Engineering Technical Evaluation ETE-SU-2011-0042 to evaluate the acceptability of the Pressurizer for continued operation. The evaluation concluded that the structural integrity impact of the transient was within design fatigue analysis margin and therefore did not affect Pressurizer operability. The inspectors determined the finding was more than minor because it adversely impacted the Barrier Integrity cornerstone objective to provide reasonable assurance that physical design barriers (reactor coolant system) protect the public from radionuclide releases caused by accidents or events. The inspectors determined that this finding was a low safety of significance (Green) because there was no actual degradation of the barrier function of the control room against radiological hazards, smoke, or toxic atmosphere. The inspectors determined that licensee correctly evaluated the finding and developed appropriate corrective action as documented in the licensees CAP as CR422769. |
Site: | Surry ![]() |
---|---|
Report | IR 05000280/2011003 Section 4OA7 |
Date counted | Jun 30, 2011 (2011Q2) |
Type: | NCV: Green |
cornerstone | Barrier Integrity |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | M Endress R Rodriguez T Morrissey J Nadel L Lake R Carrion G Mccoy R Clagg M Coursey C Fletcher B Collins J Montgomery C Jones G Sandel |
INPO aspect | |
' | |
Finding - Surry - IR 05000280/2011003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Surry) @ 2011Q2
Self-Identified List (Surry)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||