05000271/FIN-2009006-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to take adequate corrective actions for a HPCI system functional failure |
| Description | The team identified a Green non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, for Entergys failure to take adequate corrective actions for a condition adverse to quality involving an issue that had the potential to negatively impact the high pressure coolant injection (HPCI) system. Specifically, Entergy failed to take timely and appropriate corrective actions commensurate with the safety significance (potential repeat functional failure of the HPCI system due to degraded direct current (DC) contactors) of the issue. Entergys short-term corrective actions included a visual inspection of several affected DC breaker cubicles, a HPCI system operability evaluation, and interim guidance to plant operators. Entergy entered the condition into their CAP (CR 2009-1489) and performed a root cause evaluation. The finding is more than minor because it affected the equipment performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective of ensuring the reliability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the adverse condition represented a challenge to the reliability of the HPCI system due to the systems vulnerability to a repeat functional failure. The finding was determined to be of very low safety significance (Green) because it: was not a design or qualification deficiency confirmed not to result in loss of operability; did not represent a loss of system safety function; did not represent actual loss of safety function of a single train for greater than its technical specification allowed outage time; did not represent an actual loss of safety function of one or more non-technical specification trains for equipment designated as risk-significant per 10 CFR 50.65 for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />; and did not screen as potentially risk significant due to a seismic, flooding, or severe weather initiating event. This finding has a crosscutting aspect in the area of Problem Identification and Resolution, Corrective Action Program Component, because Entergy failed to take appropriate corrective actions to address a safety issue in a timely manner, commensurate with the safety significance and complexity P.1.d]. Specifically, Entergy did not take appropriate corrective actions to adequately address the extent of condition for a HPCI functional failure in June 2007 due to degraded DC contactors prior to April 2009. (Section 4OA2.1.c |
| Site: | Vermont Yankee File:NorthStar Vermont Yankee icon.png |
|---|---|
| Report | IR 05000271/2009006 Section 4OA2 |
| Date counted | Jun 30, 2009 (2009Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | K Young J Schoppy R Powell J Ambrosini |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Vermont Yankee - IR 05000271/2009006 | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Vermont Yankee) @ 2009Q2
Self-Identified List (Vermont Yankee)
| ||||||||||||||||||||||||||||||||||||||||||