Finding | |
|---|---|
| Title | Inadequate 10 CFR 50.59 Safety Evaluation Associated with Revising UFSAR Section 3.2.2 to Remove the Spent Fuel Pool as a Suction Source for a High Pressure Injection Pump After Certain Tornadoes |
| Description | 10 CFR 50.59 (a)(1) (as revised January 1, 1999) states in part, that the licensee may make changes in the facility as described in the safety analysis report without prior Commission approval, provided the proposed change does not involve an unreviewed safety question (USQ). 10 CFR 50.59 (a)(2) states, in part, that a proposed change involves an USQ if the probability of occurrence or malfunction of equipment important to safety previously evaluated in the safety analysis report may be increased
The Updated Final Safety Analysis Report (UFSAR) Section 3.2.2, System Quality Group Classification, states, in part, that a sufficient supply of primary side makeup water is assured during a tornado initiated loss of offsite power by several sources. Included in these sources is a high pressure injection (HPI) pump taking suction from the spent fuel pool (SFP) UFSAR Section 3.2.2 further states that protection against a tornado is an Oconee design criterion, and that capability is provided to safely shut down all three units, in that, after a tornado, normal shutdown systems will remain available or alternate systems will be available to allow shutdown of the plant Contrary to the above, on August 28, 2000, the licensee completed a 10 CFR 50.59 safety evaluation to revise UFSAR Section 3.2.2 and delete the SFP as a suction source for the HPI pump after certain tornadoes, thereby increasing the probability of the malfunction of equipment important to safety. This resulted in an USQ for which the licensee did not have prior Commission approval. |
| Site: | Oconee |
|---|---|
| Report | IR 05000269/2001006 Section 4OA4 |
| Date counted | Mar 31, 2001 (2001Q1) |
| Type: | TEV: Severity level IV |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 95001 |
| Inspectors (proximate) | M Maymi M Thomas C Ogle |
| INPO aspect | |
| ' | |