05000254/FIN-2011009-07
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | |
Description | The inspectors identified a finding of very low safety significance and associated Non-Cited Violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the failure to ensure the emergency core cooling system mode of operation of the residual heat removal system would be capable of performing its mitigating function at Mode 3. Specifically, the residual heat removal system would experience flash evaporation during a rapid system depressurization while in Mode 3 and this condition was not analyzed. This finding was entered into the licensees corrective action program. The performance deficiency was determined to be more than minor because it was associated with the Mitigating System Cornerstone attribute of Equipment Performance and affected the cornerstone objective of ensuring the capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the design of the residual heat removal system did not ensure that its emergency core cooling mode of operation would be capable of performing its mitigating function at Mode 3. Steam voids would form when transitioning from decay heat removal to emergency core cooling mode of operation in Mode 3 and this condition was not analyzed. The finding screened as very low safety significance (Green) using a Significance Determination Process Phase II evaluation. This finding had a cross-cutting aspect in the area of problem identification and resolution because the licensee did not thoroughly evaluate relevant external operating experience. Specifically, the licensees evaluation of similar operating experience such as Information Notice 2010-11 incorrectly concluded the station was not vulnerable to the operating experience described therein. |
Site: | Quad Cities |
---|---|
Report | IR 05000254/2011009 Section 4OA5 |
Date counted | Dec 31, 2011 (2011Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | |
Inspectors (proximate) | Z Falevits S Sheldon W Sherbin D Melendez-Colon C Brown N Feliz-Adomo A Stone J Chiloyen |
CCA | P.5, Operating Experience |
INPO aspect | CL.1 |
' | |
Finding - Quad Cities - IR 05000254/2011009 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Quad Cities) @ 2011Q4
Self-Identified List (Quad Cities)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||