| Title | Violation of Technical Specification 5.5.1.1 regarding Unit 3 spent fuel storage with degrading Boraflex poison |
| Description | The inspectors identified an apparent violation of Technical Specification 5.5.1.1requirements regarding storage of fuel assemblies in the Unit 3 spent fuel pool when Keff limits for fuel configurations were not maintained using methods described in the Final Safety Analysis Report, potentially leading to a loss of shutdown margin should a dilution event occur in the pool. When identified to the licensee, the spent fuel pool boron concentration was administratively increased and other actions were planned to restore compliance. This finding was considered more than minor because the design control attribute that assured fuel assemblies remain subcritical in the spent fuel pool was affected. The finding was determined to potentially have greater significance because of the lack of both criticality monitoring capability in the spent fuel pool and procedures for responding to an inadvertent criticality. The inspectors evaluated this finding against NRC IMC 0609Phase 1 Screening Worksheet for Initiating Events, Mitigation Systems, and Barriers Cornerstones. The inspectors determined that IMC 0609, Appendix M is required to determine the level of safety significance of this finding because the existing SDP guidance is not adequate to provide reasonable estimates of the finding significance within the established SDP timeliness goal of 90 days. NRC staff is currently reviewing this finding to determine the level of safety significance or enforcement aspect of the issue. |
| Site: | Turkey Point |
|---|---|
| Report | IR 05000250/2009005 Section 4OA2 |
| Date counted | Dec 31, 2009 (2009Q4) |
| Type: | AV: |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Nielsen C Fletcher G Kuzo J Stewart M Barillas M Coursey M Sykesd Richj Dodson J Paige S Ninh |
| INPO aspect | |
| ' | |
Finding - Turkey Point - IR 05000250/2009005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Turkey Point) @ 2009Q4
Self-Identified List (Turkey Point)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||