Finding | |
---|---|
Title | Licensee-Identified Violation |
Description | In April 2011 the licensee determined that several paths existed, in addition to previously evaluated condensate storage tank (CST) to hotwell make-up valve path, which could cause gravity drain of the CST to the hotwell due to multiple spurious operations. As a result, the licensee determined that a review and circuit analysis of other CST and clean demineralizer paths needed to be performed. The licensee initiated a circuit analysis review, which was still in progress at the time of this inspection, to more fully address potential CST drain down scenarios. Based on the inspectors review, it was determined that the above non-compliance for an MSO (Scenario 2aj, Loss of CST Inventory to Hot Well, of NEI 00-01, Table G-1, BWR Generic MSO List) was a violation of 10 CFR Part 50, Appendix R, Section III.G. The inspectors determined that the licensees existing procedures already addressed the more significant potential drain down path event involving spurious opening of CST to hotwell make-up valves and that a drain down event would occur over a relatively long period of time, providing operators an opportunity to intervene. Therefore, inspectors assigned a low degradation to this finding and determined that it screened as having very low safety significance (Green). The licensee initiated ARs 01257847, FP Triennial: MSO Scenario Did Not Have IR, and 01257854, MSOPS 2aj: CST Drain Down, to add Scenario 2aj to the corrective action program. |
Site: | Dresden ![]() |
---|---|
Report | IR 05000237/2011008 Section 4OA7 |
Date counted | Dec 31, 2011 (2011Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | Z Falevits R Daley R Langstaff R Winter J Bowen S Belding |
INPO aspect | |
' | |
Finding - Dresden - IR 05000237/2011008 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Dresden) @ 2011Q4
Self-Identified List (Dresden)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||