LER-1981-005, Forwards LER 81-005/03L-0
Event date:
Report date:
0291981005R00 - NRC Website

text

q-n YANKEE ATOMIC ELECTRIC COMPANY y.

%N Rowe,Mossachusctts 01367

.Yauxes y\\\\ \\W!lpq e

f June 1, 1981

({[

)

!!r. B.11. Grier, Director E

jutt 0 3198 i

U.S. Nuclear Regulatory Commission n2snoL* C.

Office of Inspection and Enforcement 8'5'# OMS"

^

s Region I A8 631 Park Avenue

[

g King of Prussia, Pennsylvania 19406 8 s,P Subject: Licensee Event Report 50-29/81-05/03L Failure of #17 Control Rod to Scram

Dear Mr. Grier:

In accordance with Technical Specifications, Section 6.9.4.b, the attached Licensee Event Report is hereby submitted.

Very truly yours, ffs ha

.M A

llerbert A. Autio Plant Superintendent LDF/amt

Enclosure:

cc:

[30] Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C. 20555 [3] Director, Office ot' Management Information & Program Control U.S. Nuclear Regulatory Commission Washington, D.C. 20555 [14] NSARC Chairman [1] Manager of Operational Quality Assurance (YAEC)

[1] Institute of Nuclear Power Operations (INPO)

[1] Nuclear Safety Analysis Center (NSAC) 8186040491