ENS 50342
ENS Event | |
---|---|
00:30 May 30, 2014 | |
Title | Agreement State Report - Failure of Source to Retract |
Event Description | The following information was received via E-mail:
The Assistant Radiation Safety Officer (ARSO) of Mistras reported to the Division of Radiation Control (DRC) that a radioactive source could not be returned to the shielded position in a radiography camera. The radiography technician failed to connect the guide tube to the stiff extension they were using to make superimposed exposures. When the technician cranked out the source, he cranked the cable past the assembly gear and could not retrieve the source. The technician then roped off the area of the incident to ensure individuals did not enter a high radiation area, and informed personnel at the refinery that an incident had occurred. The ARSO was then contacted and informed of the situation. The ARSO arrived on the scene of the incident and performed surveys near the exposure device to determine what the high and low levels of radiation were. The ARSO selected a spot where he could reach the radiography camera's crank handle that was in an area with a dose rate of 4 mR/hr. The ARSO used a hack saw to cut the crank handle off of the guide tube. Once the crank handle was removed, the ARSO pulled the guide cable to retract the source back into the camera's shielded position. The camera was then surveyed and returned to the licensee's storage facility. No personnel involved in the incident received exposures in excess of the regulatory limits. On May 30, 2014, at approximately 5:00 pm [MDT] the DRC inspectors arrived at the Mistras's facility. The inspectors interviewed personnel involved in the event and collected statements. The inspectors took photographs of the exposure device, collimator, and performed surveys of the camera. The inspectors confirmed that the radioactive sealed source was stopped in the camera's shielded position. Radiography exposure device information: Model INC-100, S/N 4419. The radiography camera contains a 68 Curie Ir-192 source. The event took place at the Chevron refinery located at 2351 North/1100 West, Salt Lake City, Utah. Utah Event Report ID No.: UT140002.
The following event update was received from the Utah Department of Environmental Quality, Division of Radiation Control via email: No personnel involved in the incident received exposures in excess of the regulatory limits. On May 30, 2014, the day after the incident, DRC inspectors interviewed personnel involved in the event and collected statements. The inspectors took photographs of the industrial radiography exposure device and performed surveys of the device. The inspectors confirmed that the radioactive sealed source was stopped in the device's shielded position. Notified R4DO (Campbell) and FSME Events Resource via email. |
Where | |
---|---|
Mistras Group, Inc. North Salt Lake City, Utah (NRC Region 4) | |
License number: | UT0600485 |
Organization: | Utah Division Of Radiation Control |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+1618.97 h67.457 days <br />9.637 weeks <br />2.218 months <br />) | |
Opened: | Spencer Wickham 11:28 Aug 5, 2014 |
NRC Officer: | Donald Norwood |
Last Updated: | Aug 12, 2014 |
50342 - NRC Website | |
Mistras Group, Inc. with Agreement State | |
WEEKMONTHYEARENS 564882023-04-25T04:00:00025 April 2023 04:00:00
[Table view]Agreement State Damaged Radiography Camera ENS 559712022-06-16T07:00:00016 June 2022 07:00:00 Agreement State Lost Shipment ENS 558722022-05-02T05:00:0002 May 2022 05:00:00 Agreement State Radiography Source Disconnect ENS 557172022-01-28T05:00:00028 January 2022 05:00:00 Agreement State Radiography Camera Equipment Failure ENS 556672021-12-17T03:00:00017 December 2021 03:00:00 Agreement State Radiography Device Safety Latch Failure ENS 530332017-10-19T16:05:00019 October 2017 16:05:00 Agreement State Agreement State Report - Whole Body Monitor Exceeded the Annual Occupational Exposure Limit ENS 527042017-04-20T17:30:00020 April 2017 17:30:00 Agreement State Agreement State Report - Unsecured Radiography Camera ENS 521992016-08-24T05:00:00024 August 2016 05:00:00 Agreement State Agreement State Report - Potential Radiographer Overexposure ENS 521102016-07-18T23:05:00018 July 2016 23:05:00 Agreement State Agreement State Report - Radiographer Unplanned Exposure ENS 516412015-12-19T06:00:00019 December 2015 06:00:00 Agreement State Agreement State Report - Human Error Prevents a Radiography Source from Retracting ENS 516082015-12-11T22:38:00011 December 2015 22:38:00 Agreement State Agreement State Report - Unattended Radiographic Exposure Device ENS 503422014-05-30T00:30:00030 May 2014 00:30:00 Agreement State Agreement State Report - Failure of Source to Retract ENS 498162014-02-09T18:35:0009 February 2014 18:35:00 Agreement State Agreement State Report - Radiography Camera Left Unattended ENS 498172014-02-09T14:00:0009 February 2014 14:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 496362013-12-14T08:00:00014 December 2013 08:00:00 Agreement State Agreement State Report - Stuck Radiography Source ENS 490092013-05-06T05:00:0006 May 2013 05:00:00 Agreement State Agreement State Report - Stuck Radiography Source 2023-04-25T04:00:00 | |