ENS 49009
ENS Event | |
|---|---|
05:00 May 6, 2013 | |
| Title | Agreement State Report - Stuck Radiography Source |
| Event Description | The following information was received via E-mail:
Licensee reported a stuck radiography source that occurred at approximately 2315 CDT on May 6, 2013. Licensee's RSO [Radiation Safety Officer] responded to incident site, increased barricades, maintained perimeter, and notified Chevron RSO. Licensee's source was fully retracted into the shielded position at 0100 CDT [on May 7, 2013]. The Licensee's RSO received 20 mR conducting the source retrieval. The incident occurred while performing work at the Chevron Pascagoula Refinery. Mississippi Report Number: MS-13002
The following report was received via e-mail: On 5/6/2013, the Licensee had a two man crew performing industrial radiography at the Chevron Plant. The radiographer was unable to crank the source back into the camera after his third exposure. The source was then cranked back into the collimator. The radiographer repositioned the cranks and tried to retract the source again without success. The radiographer and assistant radiographer extended the restricted area boundary and called the Licensee's night safety officer on site. The Licensee's RSO then notified Mistras Group's CRSO [Corporate Radiation Safety Officer] and plant personnel of the incident. The Licensee's RSO, once on site, discovered from conversation with the radiographer that the drive cable was hitting a melted area of the conduit and not letting the drive cable pass through. The melting of the (black) return conduit of the cranks occurred because it was placed over a non-insulated pipe from the plant's furnace. The Licensee's RSO made the decision to cut the conduit at the melted area of the cranks to save time and reduce exposure while trying to retract the source. This provided clearance for the drive cable to pass through and allowed the source to retract back into the fully shielded position inside the camera. The camera, guide tube, and cranks were surveyed by the RSO upon source retraction. The State (Mississippi) has closed this case. Notified the R4DO (Walker) and FSME Events Resources via email. |
| Where | |
|---|---|
| Marathon Martinez Renewable Fuels Pascagoula, Mississippi (NRC Region 4) | |
| License number: | MS-995-01 |
| Organization: | Mississippi Div Of Rad Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+34.08 h1.42 days <br />0.203 weeks <br />0.0467 months <br />) | |
| Opened: | Jayson Moak 15:05 May 7, 2013 |
| NRC Officer: | Donald Norwood |
| Last Updated: | May 17, 2013 |
| 49009 - NRC Website
Loading map... | |
Martinez Refining Company with Agreement State | |
WEEKMONTHYEARENS 580622025-11-24T06:00:00024 November 2025 06:00:00
[Table view]Agreement State ≪Br≫≪Br≫ ENS 571702024-06-04T17:34:0004 June 2024 17:34:00 Agreement State Agreement State Report - Stuck Source ENS 564882023-04-25T04:00:00025 April 2023 04:00:00 Agreement State Damaged Radiography Camera ENS 559712022-06-16T07:00:00016 June 2022 07:00:00 Agreement State Lost Shipment ENS 558722022-05-02T05:00:0002 May 2022 05:00:00 Agreement State Radiography Source Disconnect ENS 557172022-01-28T05:00:00028 January 2022 05:00:00 Agreement State Radiography Camera Equipment Failure ENS 556672021-12-17T03:00:00017 December 2021 03:00:00 Agreement State Radiography Device Safety Latch Failure ENS 530332017-10-19T16:05:00019 October 2017 16:05:00 Agreement State Agreement State Report - Whole Body Monitor Exceeded the Annual Occupational Exposure Limit ENS 527042017-04-20T17:30:00020 April 2017 17:30:00 Agreement State Agreement State Report - Unsecured Radiography Camera ENS 521992016-08-24T05:00:00024 August 2016 05:00:00 Agreement State Agreement State Report - Potential Radiographer Overexposure ENS 521102016-07-18T23:05:00018 July 2016 23:05:00 Agreement State Agreement State Report - Radiographer Unplanned Exposure ENS 516412015-12-19T06:00:00019 December 2015 06:00:00 Agreement State Agreement State Report - Human Error Prevents a Radiography Source from Retracting ENS 516082015-12-11T22:38:00011 December 2015 22:38:00 Agreement State Agreement State Report - Unattended Radiographic Exposure Device ENS 503422014-05-30T00:30:00030 May 2014 00:30:00 Agreement State Agreement State Report - Failure of Source to Retract ENS 498162014-02-09T18:35:0009 February 2014 18:35:00 Agreement State Agreement State Report - Radiography Camera Left Unattended ENS 498172014-02-09T14:00:0009 February 2014 14:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 496362013-12-14T08:00:00014 December 2013 08:00:00 Agreement State Agreement State Report - Stuck Radiography Source ENS 490092013-05-06T05:00:0006 May 2013 05:00:00 Agreement State Agreement State Report - Stuck Radiography Source 2025-11-24T06:00:00 | |