Event Description | The following was received via facsimile:
Event Narrative: While performing radiography operations at Microsoft Bld. 32 in Redmond, Washington, the radiography source could not be retracted from the collimator back into camera. The Radiation Safety Officer (RSO) of Mistras then called the Washington State Department of Health (DOH) emergency line (206 Nuclear) and an inspector was dispatched to the scene. At the scene was the RSO, Assistant RSO (trained in source recovery), assistant radiographer, and another radiographer. Assistance was being provided via telephone by QSA Global. It is not known yet if previous attempts brought the source through the camera and into the crank cable tube. However, while attempting to remedy the situation the (0-200 mR) pocket dosimeter of the radiographer had gone off scale. The radiographer was removed from the scene and his TLD has been sent in via overnight mail for emergency processing. The collimator was attached to the camera with a 2-3 inch long fitting (there was no guide tube). After disconnecting the crank cable from the camera, the crank cable was pulled back to the crank (while observing survey meters), and it was discovered that the connector at the end of the cable where it was attached to the pig tail was broken. The camera and collimator were loaded onto a dry wall cart and covered with several bags of lead shot. A moving 2 mR/hr barrier was established around the cart during this movement. The apparatus was then moved to a remote area of the parking lot. Once in the parking lot, 2 mR/hr barricades were set up. Eight foot long tools were made in order to unscrew the fitting from the collimator. Once the fitting was removed, the connector end of the pigtail was exposed and could be pulled out (with eight foot grappler) of the collimator and inserted into another camera. This procedure was practiced several times with a dummy source prior to the actual transfer. The highest dose received on the retrieval team was 93 mR. An investigation is about to begin, and Mistras was performing reenactments earlier today. More information pending.
The retrieval team leader received 43 mR with pocket dosimeter, the licensee RSO received 93 mR with pocket dosimeter, the assistant radiographer received 85 mR with pocket dosimeter, and the radiographer received 40 mR with pocket dosimeter. Notified R4DO (Lantz) and FSME Events Resource via email.
The following information was received via e-mail: This incident has been closed as of May 29, 2014. The two sides of the crankshaft fractures were analyzed to determine the nature of the fracture mechanism. A reenactment was performed at the licensees facility. Radiographers were re-trained with respect to not attempting retrieval procedures without training or contacting the RSO, and supervision of assistants has been adequately addressed by the licensee. Details of any of these issues are available upon request. Washington Incident #WA-13-062 Notified the R4DO (Vasquez) and FSME Resources (via e-mail). |
Where | |
---|---|
Mistras Group, Inc. Redmond, Washington (NRC Region 4) | |
License number: | WN-IR011-1 |
Organization: | Wa Division Of Radiation Protection |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+60.03 h2.501 days <br />0.357 weeks <br />0.0822 months <br />) | |
Opened: | Stephen Matthews 20:02 Dec 16, 2013 |
NRC Officer: | Daniel Mills |
Last Updated: | May 29, 2014 |
49636 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 49636\u003C/a\u003E - \u003Ca href=\"/Martinez_Refining_Company\" title=\"Martinez Refining Company\"\u003EMartinez Refining Company\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EAgreement State Report - Stuck Radiography Source\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 49636 - Martinez Refining Company\n","link":"","lat":38.01308888888889,"lon":-122.10603888888889,"icon":""}],"imageoverlays":null} | |
Martinez Refining Company with Agreement State | |
WEEKMONTHYEARENS 571702024-06-04T17:34:0004 June 2024 17:34:00
[Table view]Agreement State Agreement State Report - Stuck Source ENS 564882023-04-25T04:00:00025 April 2023 04:00:00 Agreement State Damaged Radiography Camera ENS 559712022-06-16T07:00:00016 June 2022 07:00:00 Agreement State Lost Shipment ENS 558722022-05-02T05:00:0002 May 2022 05:00:00 Agreement State Radiography Source Disconnect ENS 557172022-01-28T05:00:00028 January 2022 05:00:00 Agreement State Radiography Camera Equipment Failure ENS 556672021-12-17T03:00:00017 December 2021 03:00:00 Agreement State Radiography Device Safety Latch Failure ENS 530332017-10-19T16:05:00019 October 2017 16:05:00 Agreement State Agreement State Report - Whole Body Monitor Exceeded the Annual Occupational Exposure Limit ENS 527042017-04-20T17:30:00020 April 2017 17:30:00 Agreement State Agreement State Report - Unsecured Radiography Camera ENS 521992016-08-24T05:00:00024 August 2016 05:00:00 Agreement State Agreement State Report - Potential Radiographer Overexposure ENS 521102016-07-18T23:05:00018 July 2016 23:05:00 Agreement State Agreement State Report - Radiographer Unplanned Exposure ENS 516412015-12-19T06:00:00019 December 2015 06:00:00 Agreement State Agreement State Report - Human Error Prevents a Radiography Source from Retracting ENS 516082015-12-11T22:38:00011 December 2015 22:38:00 Agreement State Agreement State Report - Unattended Radiographic Exposure Device ENS 503422014-05-30T00:30:00030 May 2014 00:30:00 Agreement State Agreement State Report - Failure of Source to Retract ENS 498162014-02-09T18:35:0009 February 2014 18:35:00 Agreement State Agreement State Report - Radiography Camera Left Unattended ENS 498172014-02-09T14:00:0009 February 2014 14:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 496362013-12-14T08:00:00014 December 2013 08:00:00 Agreement State Agreement State Report - Stuck Radiography Source ENS 490092013-05-06T05:00:0006 May 2013 05:00:00 Agreement State Agreement State Report - Stuck Radiography Source 2024-06-04T17:34:00 | |