Pages that link to "05000334/LER-1982-016, Forwards LER 82-016/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000334/LER-1982-016, Forwards LER 82-016/03L-0:
Displayed 50 items.
- 05000334/LER-1982-025, Forwards LER 82-025/03L-0 (← links)
- 05000334/LER-1982-021, Forwards LER 82-021/03L-0 (← links)
- 05000334/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000334/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000334/LER-1982-014, Forwards LER 82-014/01T-0 (← links)
- 05000334/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000334/LER-1982-041, Forwards LER 82-041/03L-0 (← links)
- 05000334/LER-1982-036, Forwards LER 82-036/03L-0 (← links)
- 05000334/LER-1982-040, Forwards LER 82-040/03L-0 (← links)
- 05000334/LER-1982-033, Forwards LER 82-033/03L-0 (← links)
- 05000334/LER-1982-032, Forwards LER 82-032/03L-0 (← links)
- 05000334/LER-1982-029, Forwards LER 82-029/03L-0 (← links)
- 05000334/LER-1982-055, Forwards LER 82-055/03L-0 (← links)
- 05000334/LER-1982-057, Forwards LER 82-057/03L-0 (← links)
- 05000334/LER-1982-058, Forwards LER 82-058/03L-0 (← links)
- 05000334/LER-1982-028, Forwards LER 82-028/03L-0 (← links)
- 05000334/LER-1982-030, Forwards LER 82-030/03L-0 (← links)
- 05000334/LER-1982-024, Forwards LER 82-024/03L-0 (← links)
- 05000334/LER-1982-026, Forwards LER 82-026/03L-0 (← links)
- 05000334/LER-1982-027, Forwards LER 82-027/03L-0 (← links)
- 05000334/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000334/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000334/LER-1982-052, Forwards LER 82-052/03L-0 (← links)
- 05000334/LER-1982-049, Forwards LER 82-049/03L-0 (← links)
- 05000334/LER-1982-047, Forwards LER 82-047/03L-0 (← links)
- 05000334/LER-1982-039, Forwards LER 82-039/03L-0 (← links)
- ML20079G203 (redirect page) (← links)
- 05000334/LER-1982-016 (redirect page) (← links)
- 05000334/LER-1982-056, Forwards LER 82-056/03L-0 (← links)
- 05000334/LER-1982-012, Forwards Updated LER 82-012/01X-1 (← links)
- 05000334/LER-1982-054, Forwards LER 82-054/04L-0 (← links)
- 05000334/LER-1982-038, Forwards LER 82-038/03L-0 & Updated LER 82-036/03X-1 (← links)
- 05000334/LER-1982-004, Forwards LER 82-004/03L-0 (← links)
- 05000334/LER-1982-013, Forwards Updated LER 82-013/99X-1 (← links)
- 05000334/LER-1982-006, Forwards Updated LER 82-006/03L-1 (← links)
- 05000334/LER-1982-048-03, /03L-2:on 821018,during Startup of Main Feed Pump 1B Apparent Overcurrent Condition Detected.Caused by Conservative Transformer Primary Side Overcurrent Relay Setting.Replacement of Relays Planned (← links)
- 05000334/LER-1982-016-03, /03L-0:on 820427,turbine Auto Stop Oil Pressure switch,PS-TB63-5AST,found Inoperable & Trip Setpoints for PS-TB63-4AST & 6AST Found Out of Spec.Caused by Lug Blocking Trip Mechanism & Instrument Drift,Respectively (← links)
- 05000334/LER-1982-056-03, /03L-0:on 821126,during Normal Power Operation, Hydrogen Recombiner 1B Failed Surveillance Test 1.46.4 Due to Inability to Achieve Acceptance Criteria Temp of 700 F. Caused by Design Problem W/Resistors in Temp Control Unit (← links)
- 05000334/LER-1982-012-01, Total of Seven Overstressed Pipe Supports Found Upstream of Main Steam Line Containment Isolation Valves.Caused by Failure to Include Branch Line Loading in Calculations (← links)
- 05000334/LER-1982-054-04, /04L-0:on 820923,continuous Chlorination of Circulating Water Sys Occurred Over 7-h Period.Highest Free Chlorine Residual Measured 0.45 Mg/L.Caused by Personnel Error.Sys Given to Chemistry Group & Will Be Automated (← links)
- 05000334/LER-1982-038-03, /03L-0:on 820925,during Attempt to Secure Turbine Driven Auxiliary Feed pump,TV-MS-105B Failed to Close.Caused by Nut Lodging in TV-MS-105B Valve Body Due to Failed Check Valve MS-20.Nut Removed (← links)
- 05000334/LER-1982-004-03, /03L-0:on 820127,backup RHR Pump Lost out-of-svc When Normal Ac Power Source Lost Due to Fault in Section of 4 Kv Bus Cable.Cause for Cable Fault Unknown.Cable Returned to Vendor for Analysis (← links)
- 05000334/LER-1982-052-03, /03L-0:on 821105,leaking Fire Hydrant Reported in Southeast Yard.Cause Not Stated.Leak Isolated & Temporary Fire Hose Installed in Fuel Bldg to Insure Adequate Fire Protection (← links)
- 05000334/LER-1982-053-03, /03L-0:on 820916,chemistry Personnel Failed to Obtain Boron Sample of Safety Injection Accumulator 1A During Two Sampling Periods in 1981.Caused by Misunderstanding Among Chemists Over Sampling Frequency (← links)
- 05000334/LER-1982-049-03, /03L-0:on 821111,containment Vacuum Pump 1A Observed Not Rotating.Caused by Binding Between Pump Rotor & Vanes Due to Corrosion Buildup.Pump Shaft Manually Rotated & Freed.Design Change Being Investigated (← links)
- 05000334/LER-1982-051-03, /03L-0:on 821104,while Performing Routine Surveillance,Area Radiation Monitor RIS-RM207 Failed Off Scale Low.Caused by Multiple Electrical Component Failures. Faulty Parts Replaced & Monitor Returned to Svc on 821117 (← links)
- 05000334/LER-1982-034-03, /03L-0:on 820915,during Surveillance Test Containment Vacuum Pump Failed Required Discharge Flow Rate. Caused by Buildup of Dirt & Debris in Discharge Line.Line Cleaned & Suction & Discharge Filters Replaced (← links)
- 05000334/LER-1982-045-03, /03L-0:on 821017,1A Containment Vacuum Pump Drive Belt Broke.Caused by Aging.Drive Belt Replaced (← links)
- 05000334/LER-1982-046-03, /03L-0:on 821023,shutdown Bank B Rod E-11 Declared Inoperable When Rod & Primary Voltage Readings Indicated Misalignment.Caused by Primary Voltage Power Supply Drift. Supply Adjusted (← links)
- 05000334/LER-1982-043-03, /03L-0:on 821013,axial Flux Difference Monitor Alarm Discovered Inoperable Due to Plant Computer Trouble. Caused by Operator Error.Tech Spec Surveillance Requirements Discussed W/Operator & Computer Engineer (← links)