Pages that link to "05000313/LER-1983-009, Forwards LER 83-009/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000313/LER-1983-009, Forwards LER 83-009/03L-0:
Displayed 50 items.
- 05000368/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000368/LER-1983-004, Forwards LER 83-004/03L-0 (← links)
- 05000313/LER-1983-008, Forwards LER 83-008/03L-0 (← links)
- 05000368/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000313/LER-1983-023, Updated LER 83-023/03X-6:on 830916-1120,fire Protection Deficiencies Discovered.Caused by Inadequate Original Installation Specs & Acceptance Criteria.Walkdown Insp in Progress.Insp Program Being Developed (← links)
- 05000368/LER-1983-005, Forwards LER 83-005/03L-0 (← links)
- 05000368/LER-1983-006, Forwards LER 83-006/03L-0 (← links)
- 05000368/LER-1983-002, Forwards LER 83-002/03L-0 (← links)
- 05000368/LER-1983-020, Telecopy LER 83-020/01T-0:on 830519,fire Watch Posted in Wrong Location for Period Exceeding Tech Spec Limit.Further Details Will Be Provided (← links)
- 05000313/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000313/LER-1983-005, Forwards LER 83-005/03L-0 (← links)
- ML20073R036 (redirect page) (← links)
- 05000313/LER-1983-009 (redirect page) (← links)
- 05000313/LER-1983-007, Revised LER 83-007/03X-1:on 830308 & 21,reactor Bldg Pressure Switches PS-2403 & PS-2401 Found to Be Out of Tolerance,Opening at 18.9 Psia.Pressure Switches Reset at 18.5 Psia Per Calibr Procedure (← links)
- 05000368/LER-1983-016, Forwards LER 83-016/03L-0 (← links)
- 05000368/LER-1983-017, Forwards LER 83-017/03L-0 (← links)
- 05000368/LER-1983-015, Forwards LER 83-015/03L-0 (← links)
- 05000368/LER-1983-019, Forwards LER 83-019/03L-0 (← links)
- 05000368/LER-1983-012, Forwards LER 83-012/03L-0 (← links)
- 05000368/LER-1983-008, Forwards LER 83-008/03L-0 (← links)
- 05000368/LER-1983-014, Forwards LER 83-014/01T-0 (← links)
- 05000368/LER-1983-036-04, Wind Direction Indication at 40 Ft elevation,180 Degree off-course.Caused by Mounting of Transmitter 180 Degree from Correct Position.Transmitter Mounted Correctly & Aligned (← links)
- 05000368/LER-1983-050-99, /99X-0:on 831109,diesel Generator 2 Exhibited Erratic Performance.Caused by Bad Contacts on Droop Relay in Conjunction W/Less than Optimum Tuning of Governor Controls.Droop Relay Replaced (← links)
- 05000368/LER-1983-043-03, /03L-0:on 830907,contract Person Posted for Fire Watch Duty Discovered Asleep.Individual Awakened & Relieved.Disciplinary Actions Taken.Fire Watch Policy Expanded (← links)
- 05000313/LER-1983-028-03, /03L-0:on 831130,during Radwaste Processing,Crack Discovered in Discharge Piping of Clean Waste Transfer Pump P-47B.Probably Caused by Overheating of Pipe During Installation of Valve Along W/Piping Stresses (← links)
- 05000313/LER-1983-029-03, /03L-0:on 831129,bottoms of Carbon Filter for Penetration Room Ventilation Fans Found Wet.Caused by Water from Hydrogen Purge Sys Carried Over Into Plant Vent During Hydrogen Purge Sys Operation.Filters Replaced (← links)
- 05000368/LER-1983-049-01, /01T-0:on 831212,due to Procedural & Personnel Errors Identified in Station Battery Surveillance Requirements,Review of Addl Surveillances Conducted.Addl Past Inadequacies Discovered (← links)
- 05000313/LER-1983-026-01, /01T-0:on 831118,review Revealed Fuel Oil Analysis for 830607 Did Not Meet Tech Spec Requirements.Caused by Personnel Failure to Recognize out-of-spec Condition & Place Plant in Limiting Condition for Operation (← links)
- 05000368/LER-1983-048-03, /03L-0:on 831114,no Response Observed on Startup Channel 1 of Nuclear Instrumentation When Fuel Assembly, Containing Neutron Source,Inserted Into Core.Caused by Problems in Mother Board.Board Replaced (← links)
- 05000368/LER-1983-046-03, /03L-0:on 830709,gross Activity Surveillance of Secondary Coolant Performed Outside Tech Spec Time Period Requirement.Caused by Personnel Error.Personnel Training Conducted (← links)
- 05000368/LER-1983-047-03, /03L-0:on 831023,channel Functional Test of Source Range Neutron Flux Monitors Not Performed within Required Surveillance Requirements.Procedure Changed (← links)
- 05000313/LER-1983-022-03, /03L-0:on 831013,as-found Voltage of 2.06 for Station Battery D07,cell 34,did Not Meet Required 2.13 Volts.Cause Not Determined.Battery Placed on Equalizing Charge (← links)
- 05000313/LER-1983-021-03, /03L-0:on 830909,during Surveillance Test on Reactor Bldg Fire Sprinkler Sys,Discovered Wiring Discrepancy.Caused by Erroneous Terminations Since Plant Const.Valve Wiring Terminated (← links)
- 05000368/LER-1983-042-03, /03L-0:on 830913 & 15,junction Box for Conduits in Fire Zone 2150 Discovered Open & Gap Between Floor & Fire Doors 340 & 267 Exceeded Acceptance Criteria.Caused by Exclusion of Zones from Installation Specs (← links)
- 05000368/LER-1983-004-01, /01T-0:on 831212,personnel Determined That During Oct 1982 18-month Test,Not All Containment Penetration Conductor Overcurrent Protection Devices Tested Per Tech Spec 4.8.2.5.a.2 (← links)
- 05000368/LER-1983-038-03, /03L-0:on 830818,core Protection Calculator Channel a Placed in Bypasss & Channel D Tripped.Caused by Point Identification Number 064 for Channels Reading Less than Min (← links)
- 05000313/LER-1983-020-03, /03L-0:on 830828,lead Hydrogen Purge Fan VEF-37A Indicated Low Output Flow.Caused by Debris Collected at Valve HPA-133.Valve Internals Cleaned (← links)
- 05000368/LER-1983-040-03, /03L-0:on 830831,control Element Assembly 47 Dropped to Lower Electrical Limit.Caused by Blown Fuse. Opened Fuse Replaced,Current Traces Taken & Tightness of Connections Checked (← links)
- 05000368/LER-1983-039-03, /03L-0:on 830825,leak Found in Weld of Pressure Sensing Line for Middle Seal of Reactor Coolant Pump.Caused by Weld Crack Due to Vibration.Line W/Cracked Weld Replaced. Mod Planned (← links)
- 05000368/LER-1983-037-03, /03L-0:on 830816,during Mode 1 Operation, Degradations in Fire Doors 257 & 270 Observed.Caused by Relocation of Signs & Security Equipment Installation & Mods.Degradations Repaired (← links)
- 05000313/LER-1983-019-01, /01T-0:on 830907,during Investigation to Determine Source of High RCS Leakage,Crack Discovered in pipe-to-flange Weld on Pump Casing Vent on Reactor Coolant Pump C (← links)
- 05000368/LER-1983-006-03, /03L-0:on 830202,while in Mode 1 at 33% Power, Control Room a Emergency Chiller 2VE-1A Tripped on High Condenser Pressure During Preventive Maint.Caused by Defective Power Supply.Power Supply Replaced (← links)
- 05000368/LER-1983-002-03, /03L-0:on 830106,control Room Indication Lost for Intake Structure Exhaust Fan 2VEF-25B.Caused by Opened Fuse Due to Grounded Motor Power Cable.Cable Replaced & Exhaust Fan Returned to Svc (← links)
- 05000313/LER-1983-024-03, /03L-0:on 830926,control Rod Assembly 10 Found Misaligned from Group Average by Greater than 9 Inches. Caused by Pole Slippage on Out Command.Control Rod Drive Malfunction Procedure Will Be Revised (← links)
- 05000313/LER-1983-025-03, /03L-0:on 831001,acceptable Sample Flow Criteria Not Met for Reactor Bldg Hydrogen Sampling Standby Purge Sys Test.Caused by Switch on Conductivity Analyzer in Off Position (← links)
- 05000368/LER-1983-030-03, /03X-1:on 830704 & 0804,remote Shutdown Panel Instrument 2JI-9000 Deviated from Control Room 2JIS-9000-1. Caused by Out of Calibr Voltage Buffer & Intermittent Indicator Output Shift,Respectively (← links)
- 05000313/LER-1983-018-03, /03L-0:on 830726,emergency Feedwater Bypass Valve CV-2626 to Steam Generator B Failed to Open from Control Room During Surveillance Test.Caused by Failure of Interlock Contact Preventing Reverse Contactor to Open (← links)
- 05000368/LER-1983-031-03, /03L-0:on 830713,control Room Emergency Air Conditioner 2VE-1B Observed Tripping Due to Low Freon. Caused by Leak in Liquid Line Serving Core Protection Calculator Room Air Conditioner.Leak Repaired (← links)
- 05000368/LER-1983-026-03, /03L-0:on 830620,deficient Fire Barrier Penetration Seals Discovered Between Walls Providing Access to Electrical Equipment & Cable Spreading Rooms.Cause Not Stated.Fire Watch Posted.Seals Repaired (← links)
- 05000368/LER-1983-029-03, /03L-0:on 830703,control Element Assembly Calculator 1 Sensor Failure Lights Came on for Assemblies 64 & 72.Caused by Failure of High Level Max Card in Calculator. Card Replaced & Calculator Returned to Svc (← links)