Pages that link to "05000269/LER-1981-018, Forwards LER 81-018/03L-1.Detailed Event Analysis Encl"
Jump to navigation
Jump to search
The following pages link to 05000269/LER-1981-018, Forwards LER 81-018/03L-1.Detailed Event Analysis Encl:
Displayed 10 items.
- ML20011A744 (redirect page) (← links)
- ML20011A747 (← links)
- ML20011A745 (← links)
- 05000269/LER-1981-018-03, /03L-1:on 810911,safety-related Battery Surveillance Procedures Found Out of Compliance W/Revised Tech Spec 4.6.9.Caused by Personnel Failure to Identify Necessary Procedure Changes.Procedures Revised (← links)
- 05000269/LER-1981-018, Forwards LER 81-018/03L-1.Detailed Event Analysis Encl (← links)
- 05000269/LER-1981-018, Forwards LER 81-018/03L-0.Detailed Event Analysis Encl (redirect page) (← links)
- ML20031F123 (redirect page) (← links)
- 05000269/LER-1981-017-03, /03L-0:on 810903,Keowee Unit 2 Tripped on Startup. Caused by Setpoint Drift in Undervoltage Relay 746GV-2. Relay Replaced (← links)
- 05000269/LER-1981-017, Forwards LER 81-017/03L-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1981-015-03, /03L-0:on 810903,reactor Protection Sys Channel B Declared Inoperable Due to Anomalous Flow Indication on Loop A.Caused by Small Leak on Low Pressure Leg Impulse Fitting of Rc Flow Transmitter 2FT14C.Leak Repaired (← links)
- 05000270/LER-1981-015, Forwards LER 81-015/03L-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1981-014-01, /01T-0:on 810821,during Routine Surveillance Testing,Electrical Penetration EMV-2 Not Pressurized w/SF6 Dielectric.Caused by Failure of Insulator Bushing.Bushing Repaired & Local Leak Rate Test Completed (← links)
- 05000270/LER-1981-014, Forwards LER 81-014/01T-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1981-007-01, /01T-0:on 810326,during Periodic Test,Auto/Manual Transfer Switches for B1T-8 & B2T-5 Incorrectly Placed in Manual Position & Not Returned After Test Completion.Caused by Personnel Error.Switches Restored to Auto Position (← links)
- 05000270/LER-1981-007, Forwards LER 81-007/01T-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1981-007, Forwards LER 81-007/03L-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1981-006-03, /03L-0:on 810328,RCS Subcooling Margin Monitors Were Discovered Inoperable When Computer Alarm Printer & Rider in Control Room Indicated All Analog Points in Alarm Condition.Caused by Failed Low Level Amplifier (← links)
- 05000287/LER-1981-006-03, /03X-1:on 810324,reactor Protection Sys Channel a High Pressure Trip Found Out of Calibr.Caused by Transmitter Drift.Pressure Transmitter Recalibr (← links)
- 05000287/LER-1981-006, Forwards LER 81-006/03X-1.Detailed Event Analysis Encl (← links)
- 05000287/LER-1981-008-03, /03L-0:on 810422,during Seismic Block Wall Insp, Discovered Breach of Fire Barrier in Penetration 3-T-T-1. Caused by Pulling of Electrical Cables Through Barrier. Breach Repaired Using RTV Foam (← links)
- 05000287/LER-1981-008, Forwards LER 81-008/03L-0.Detailed Event Analysis Encl (← links)
- 05000270/LER-1981-010, Forwards LER 81-010/03L-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1981-004-03, /03L-0:on 810312,valve 3FDW-105 Failed to Close Electrically After Chemical Sampling of Steam Generator B. No Apparent Cause Found.Valve Manually Closed & Circuit Breaker Opened,Disabling Valve (← links)
- 05000287/LER-1981-004, Forwards LER 81-004/03L-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1981-018-03, /03L-1:on 810911,safety-related Battery Surveillance Procedures Found Out of Compliance W/Revised Tech Spec 4.6.9.Caused by Personnel Failure to Identify Necessary Procedure Changes.Procedures Revised (← links)
- 05000269/LER-1981-018 (redirect page) (← links)
- 05000269/LER-1981-016-01, /01T-0:on 810903,magnetic Particle Testing on 1A2 Reactor Coolant Pressure Seal Housing Bolts Revealed Linear Indications.Bolts W/Rejectable Indications Will Be Replaced (← links)
- 05000270/LER-1981-013-03, /03L-0:on 810815,reactor Bldg Spray Pump 2A Declared Inoperable Due to Oil Leak on Bearing Oil Reservoir.Caused by Loose Piping Allowing Leakage.Reservoir Refilled W/Oil (← links)
- 05000270/LER-1981-011-03, /03L-0:on 810806 & 07,RCS Subcooling Margin Monitor Was Inoperable & Backup Method Unavailable.Caused by out-of-svc Unit 2 Operator Aid Computer Due to Malfunction of AGRA2 Group Relay Board & Matrix Card (← links)
- 05000269/LER-1981-014, Forwards LER 81-014/01L-0.Detailed Event Analysis Encl (← links)
- 05000269/LER-1981-015-01, /01T-0:on 810811,modules in Reactor Protection Sys Were Found to Have Errors Larger than Originally Calculated Values.Errors re-evaluated & Setpoints Changed to New Settings (← links)
- 05000269/LER-1981-015, Forwards LER 81-015/01T-0.Detailed Event Analysis Encl (← links)
- 05000287/LER-1981-015-01, /01T-0:on 810720,while Attempting to Perform Engineered Safeguard Periodic Test,Low Pressure Injection Pump 3-B Failed to Start.Caused by Personnel Error.Pump Motor Bearings Replaced & Personnel Counseled (← links)