ENS 46279
From kanterella
Revision as of 17:29, 24 September 2017 by StriderTol (talk | contribs) (Created page by program invented by Mark Hawes)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
ENS Event | |
---|---|
07:10 Sep 25, 2010 | |
Title | High Pressure Core Spray System Room Cooling Fans Found Not Operating |
Event Description | This report is being made pursuant to 10 CFR 50.72(b)(3)(v)(D), event or condition that could have prevented fulfillment of a safety function needed to mitigate the consequences of an accident. During steady state operations 2VD05C, Division 3 Switchgear Room / Core Standby Cooling System (CSCS) Pump Room Supply Fan and 2VD07C, Division 3 Switchgear Room / Core Standby Cooling System (CSCS) Pump Room Return Fan were found not operating. Division 3 ventilation supplies cooling to the High Pressure Core Spray System (HPCS), which is a single-train system. At the time of this discovery, there was not assurance that the HPCS would fulfill its safety function without mitigating manual actions due to the fan failure, and thus this condition is reportable. Operators are now briefed to manually operate the fan if needed to maintain proper temperature conditions until maintenance begins, thus restoring system function.
The licensee has notified the NRC Resident Inspector. |
Where | |
---|---|
Lasalle Illinois (NRC Region 3) | |
Reporting | |
10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
LER: | 05000374/LER-2010-001 |
Time - Person (Reporting Time:+3.23 h0.135 days <br />0.0192 weeks <br />0.00442 months <br />) | |
Opened: | John Keenan 10:24 Sep 25, 2010 |
NRC Officer: | Bill Huffman |
Last Updated: | Sep 25, 2010 |
46279 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 46279\u003C/a\u003E - \u003Ca href=\"/LaSalle\" title=\"LaSalle\"\u003ELaSalle\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EHigh Pressure Core Spray System Room Cooling Fans Found Not Operating\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 46279 - LaSalle\n","link":"","lat":41.24573888888889,"lon":-88.66919444444444,"icon":"/w/images/b/be/Constellation_icon.png"}],"imageoverlays":null} | |
Unit 2 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_46279&oldid=88172"