ML16344A412

From kanterella
Revision as of 12:24, 1 May 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Donald C. Cook Nuclear Plant, Units 1 & 2, Revision 27 to Updated Final Safety Analysis Report, Chapter 14, Table 14.4.6-7, Feewater Line Break at the Tee Between the 20 Inch and 30 Inch Lines, 20 Inch Line Running to Steam Generators 2 and
ML16344A412
Person / Time
Site: Cook  American Electric Power icon.png
Issue date: 10/24/2016
From:
Indiana Michigan Power Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML16336A263 List: ... further results
References
AEP-NRC-2016-42
Download: ML16344A412 (1)


Text

IINNDDIIAANNAA AANNDD MMIICCHHIIGGAANN PPOOWWEERR DD.. CC.. CCOOOOKK NNUUCCLLEEAARR PPLLAANNTT UUPPDDAATTEEDD FFIINNAALL SSAAFFEETTYY AANNAALLYYSSIISS RREEPPOORRTT Revision: 16.6Table: 14.4.6-7Page: 1 of 1 FEEDWATER LINE BREAK AT THE TEE BETWEEN THE 20 INCH AND 30 INCH LINES, 20 INCH LINE RUNNING TO STEAM GENERATORS 2 AND 3 (APPLICABLE TO MAIN STEAM ACCESSWAY) Mass and Enthalpy Forward Flow m = 9050 lbm/sec n = 431 Btu/lbm Back Flow m = 9050 lbm/sec n = 431 Btu/lbm 1.5 seconds UNIT 2