MONTHYEARML16307A4902016-10-25025 October 2016 Presentation Slides from Public Meeting Calvert Cliffs GSI-191 Resolution Update Project stage: Meeting ML16328A2832016-11-18018 November 2016 Supplemental Presentation Slides for 10/25/2016 Public Meeting Via E-mail from K.Greene to R.Guzman Calvert Cliffs GSI-191 Resolution Update Project stage: Request ML16328A3472016-11-23023 November 2016 Memo to File: E-mail from R.Guzman to E.Villar Regarding Meeting Summary of Calvert Cliffs Nuclear Power Plant Units 1 and 2 - GSI-191 Resolution on 10/25/16 Project stage: Meeting ML17249A3202017-09-18018 September 2017 Summary of Meeting with Exelon Generation Company, LLC, on Planned Submittal of Risk-Informed License Amendment and Exemption Requests Concerning Resolution of Generic Issue 191 Project stage: Meeting ML18136A4932018-05-16016 May 2018 Licensees Slides for Pre-Application Meeting W/Exelon Re Planned GSI-191 LAR for Calvert Cliffs (L-2016-LRM-0001) Project stage: Meeting ML18198A2922018-05-16016 May 2018, 17 May 2018, 18 July 2018 May 21, 2018, Meeting with Exelon Generation Company, LLC, on Planned Submittal of Risk-Informed License Amendment and Exemption Requests Concerning Resolution of Generic Issue 191 (EPID L-2016-LRM-0001 Project stage: Request ML18197A2392018-06-19019 June 2018, 21 June 2018, 20 July 2018 Summary of June 21, 2018 Meeting with Exelon Generation Company, LLC Project stage: Request ML18171A0842018-06-21021 June 2018 GSI-191 Program Use of Risk Metrics for Containment Sump Tech Spec Operability Determination June 21, 2018 Public Meeting Slides (MF8521, MF8522; L-2016-LRM-0001) Project stage: Meeting ML18201A4062018-06-21021 June 2018 Exelons Response to NRC Questions Project stage: Other ML18197A4362018-07-18018 July 2018 May 21, 2018, Summary of Meeting with Exelon Generation Company, LLC, on Planned Submittal of Risk-Informed License Amendment and Exemption Requests Concerning Resolution of Generic Issue 191 Project stage: Meeting ML18197A2292018-07-20020 July 2018 Summary of Meeting with Exelon Generation Company, Llc, on Planned Submittal of Risk Informed License Amendment and Exemption Requests Concerning Resolution of Generic Issue 191 (CAC Nos. MF8521 and MF8522; EPID L-2016-LRM-0001) Project stage: Meeting 2018-05-16
[Table View] |
Text
Calvert Cliffs GSI-191 Program Use of Risk Metrics for Containment Sump Tech Spec Operability Determination June 21, 2018
Future Licensing Basis
- After the Risk-Informed GSI-191 license amendment is approved, Calvert Cliffs licensing basis for operability of emergency recirculation sump will be risk-based.
- The risk of LOCA events that could threaten strainer performance is Very Low, which is consistent with RG 1.174 acceptance guidelines
- Proposed Technical Specification for the Containment Sump Summary of Calvert Cliffs Risk-Informed Approach 1
Debris Acceptance Guidelines
- The following is the proposed risk metric to be added to the UFSAR.
RISK INCREASE LIMITS DUE TO CONTAINMENT DEBRIS
- The CDF or LERF values due solely to the effects of debris on the emergency recirculation strainer may not exceed the following limits.
- Maximum CDF limit = 3.0E-07 - Maximum LERF limit = 3.0E-08
- Current preliminary results from GSI-191 risk analysis Summary of Calvert Cliffs Risk-Informed Approach 2
Questions/Concerns
- Jointly Review Issues, Questions, and Concerns Summary of Calvert Cliffs Risk-Informed Approach 3