From: Deakyne K
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML19305E119 List:
References
LER-79-098-03L, LER-79-98-3L, NUDOCS 8004220772
Download: ML19305E122 (2)


LER-1979-098, During Performance of Component Cooling Water Monthly Test,Decay Heat Cooler 1 Component Cooling Outlet Valve CC1467 Would Not Operate. Caused by Valve Linkage Slippage.Linkage Realigned
Event date:
Report date:
3461979098R03 - NRC Website

text

NRC FORM 36G U. S. NUCLEAR REGULATORY COMMISSION 4 77)

LICENSEE EVENT REPORT CONTROL BLOCK: l l

l l

l l lh (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) 1 6

foTil 101 H I D I a I S I I l@l 010 l - l 0101 01 0: 01-10 l 0 l@l 4 l1 l1 l 1 l 1 l@l l

l@

?

8 9 LICENSEE CODE 14 15 LICENSE NuvutR

?>

26 LICENSE T YPE JG 57 CAT b6 CON'T M

3$$ l L l@l 0 l 5 l 0 l - 10 ! 3 l 4 l 6 @l 1 l 0 l 0 l 4 l 7 l 9 l@l 1 l 0 l 3 l 0 ] 7 l 9 l@

i 8

60 61 DOCA ET NUUSER 68 trJ EVENT DATE 74 4

REPORT DATE 80 EVENT DESCRIPTION AND PHOBABLE CONSEQUENCES h 8 lOn October 4 1979 at 1007 hours0.0117 days <br />0.28 hours <br />0.00167 weeks <br />3.831635e-4 months <br /> during the performance of Component Cooling Water l

o 3 l Monthly Test, ST 5074.01, the Decay Heat Cooler 1 Component Cooling Outlet Valve I

t o l4 l l CC1467 would not operate.

This rendered Decay Heat and Low Pressure Injection Train l I'oT 1 11 inoperable placing the station in the action statement of Technical Specification I

o oe 13.5.2.

This required the inoperable train be made operable within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />. There 1

I was no danger to the health and safety of the public or station personnel. Redundant I o 7 i o Is I l Train 2 was available.

(NP-33-79-114) 1 7

8 9 80 E

CODE SUBC E COMPONENT CODE SUSC DE S

E 1[@

l Sl Fl@ {@ Q@ l Vl Al Ll Vl 0l Pl@ W@ W @

3 8

9 10 13 12 13 18 19 20 SEQUE NTI AL OCCURRENCE REPORT REVISION LE R/RO EVENT YEAR REPOR T NO.

CODE TYPE NO.

h AE l7 l9 l

[_.-j l0l9l8l y

l 0l 3l lLl [j

W gU 21 22 2J 24 26 21 28 29 JG 31 32 KN A ON ON PL NT MET HOURS 22 5 B IT FO bud.

SU PLI MANUFACTURER W@[_.F,j@

lzl@

lzl@

l0 l0 l0 l9 l ]@

l y [@

lA l g lH l0 l3 l5 l g 33 34 Jb 36 31 40 41 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h l1 l 0 l l The inoperability of CC1467 was due to slippage of the valve linkage.

The slippage l

LLL1_J l was due to a design deficiency which allows vibrations to loosen the bolt that retains l l

y I the two linkage arms.

The linkage was realigned, calibrated and successfully tested 1[E l under ST 5074.01 on 10/4/79.

On 12/10/79 the design deficiency was corrected via l

[E l the implementation of Facility Change Request 79-347.

l 8 9 80 ST S

% POWE R OTHER STATUS IS O RY DISCOVERY DESCRIPTION [t [5,,,,j W @ l1l0l0l@l NA l

l B l@l Operator observation l

A TivtTY CONTENT r.ELEASED OF RELE ASE AMOUNT OF ACTIV:TY LOCATION OF RELEASE LzJ @ Lz_J@aES l

N^

l l

NA l

is

,ERSONNEt Ex,0$

oESCRi,TiO~ @

~uM ER TY,e Li.l7.]I0101Ol@lZl@l NA l

,ERSO~NE L INJIES So l

NUV8ER

DESCRIPTION

101 OI Ol@l NA l

4

7 8 9 11 12 LOSS OF OR OAMAGE To FACILITY 80 TYPE DE SCRIPTION

[.th] Lzj@l NA l

3 8 9 10 80

DESCRIPTION

ISSUSEL 81 o

o NA i

111111-lll11111 8 9 to 8 004220 7((h 68 69 60 E DVR 79-145 NAME OF PREPARER Kenneth Deakyne 419-259-5000, E'xt. 231g

TOLEDO EDISON COMPANY DAVIS-BESSE NUCLEAR POWER STATION UNIT ONE SUPPLEMENTAL INFORMATION FOR LER NP-33-79-114 DATE OF EVENT: October 4, 1979 FACILITY: Daivs-Besse Unit 1 IDENTIFICATION OF OCCURRENCE:

Decay Heat Cooler 1 Component Cooling Outlet Valve CC1467 would not operate Conditions Prior to occurrence:

The unit was in Mode 1, with Power (MWT) = 2770, and Load (Gross MWE) = 920.

Description of Occurrence: On October 4,1979 at 1007 hours0.0117 days <br />0.28 hours <br />0.00167 weeks <br />3.831635e-4 months <br /> during the performance of ST 5074.01, Component Cooling Water Monthly, CC1467 would not move. Component Cooling Pump 1 was shut off. Additional attempts to mov e the valve were unsuccessful.

The operator suspended the test and CC1467 was declared inoperable which rendered Decay Heat and Low Pressure Injection Train 1 inoperable.

This placed the unit in the Action Statement of Technical Specification 3.5.2 which requires the inoperable train be made operable within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in Hot Shutdown within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

Designation of Apparent Cause of 0:currence: The improper operation of valve CC1467 was attributed to slippage of the valve linkage.

This was caused by a design defi-ciency which allowed vibrations to loosen the bolt that retains the two linkage arms together.

Analysis of Occurrence: There was no danger to the health and safety of the public or to station personnel. An inspection of the Decay Heat / Low Pressure Injection Train 2 was performed to assure its availability.

Corrective Action

Under Maintenance Work Order IC-455-79, the valve linkage was realigned and calibrated. The applicable portions of ST 5074.01, Component Cooling Water Monthly Surveillance Test and ST 5074.02, Component Cooling Water Syr. tem Refuel-ing Test were performed to verify operability. The valve and train 1 were declared 3

operabic at 1415 hourn on October 4, 1979.

Facility Change Request 79-347 was implemented on December 10, 1979 to prevent vibra-tions from loosening the retaining bolts on CC1467 and CC1469. This Facility Change Rtquest is identical to Facility Change Request 79-151 which resolved the vibration problems on Service Water Valves SW1429,1434 and 142.4.

Failure Data:

There have been three previously reported occurrences with valves of this type of actuators. They were reported in Licensee Event Reports NP-33-78-120, NP-33-78-147 and NP-33-79-74.

l l

LER #79-098 6