ML20007E369
| ML20007E369 | |
| Person / Time | |
|---|---|
| Site: | 05200001, 05200045 |
| Issue date: | 12/20/2019 |
| From: | Michelle Catts GE-Hitachi Nuclear Energy Americas |
| To: | Office of Nuclear Reactor Regulation |
| Shea J | |
| References | |
| GEHITACHIABWR, GEHITACHIABWR.SUBMISSION.8, 25A5675.P, 25A5675.P.7 | |
| Download: ML20007E369 (83) | |
Text
25A5675BH Revision 7 October 2019 ABWR Design Control Document Tier 2 Chapter 21 Volume 7 Copyright 1994, 2010, 2016, 2019 GE-Hitachi Nuclear Energy Americas LLC All Rights Reserved
Chapter 21 Figure TOC Volume 7-i 25A5675BH Revision 7 Design Control Document/Tier 2 ABWR Figure 8.3-1 Electrical Power Distribution System SLD (Sheets 1-3).......................................21-696 Figure 8.3-2 Instrument and Control Power Supply System SLD...............................................21-699 Figure 8.3-3 Plant Vital AC Power Supply System SLD (Sheets 1-2).......................................21-700 Figure 8.3-4 Plant DC Power Supply System SLD (Sheets 1-3)................................................21-702 Figure 9.1-1 Fuel Pool Cooling and Cleanup System P&ID (Sheets 1-3)..................................21-705 Figure 9.1-2 Fuel Pool Cooling and Cleanup System PFD (Sheets 1-2)....................................21-708 Figure 9.1-12 Plant Refueling and Servicing Sequence................................................................21-710 Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheets 1-9)................................21-711 Figure 9.2-1a Not Used Figure 9.2-2 HVAC Normal Cooling Water System P&ID........................................................21-720 Figure 9.2-3 HVAC Emergency Cooling Water System P&ID (Sheets 1-3).............................21-721 Figure 9.2-4 Makeup Water System (Condensate) P&ID...........................................................21-724 Figure 9.2-5 Makeup Water System (Purified) P&ID (Sheets 1-3)............................................21-725 Figure 9.2-7 Reactor Service Water System P&ID (Sheets 1-3)................................................21-728 Figure 9.3-1 Standby Liquid Control System P&ID...................................................................21-731 Figure 9.3-1a Standby Liquid Control System PFD......................................................................21-732 Figure 9.3-6 Instrument Air System P&ID (Sheets 1-2).............................................................21-733 Figure 9.3-7 Station Service Air System P&ID (Sheets 1-2)......................................................21-735 Figure 9.4-1 Control Building HVAC Flow Diagram (Sheets 1-5)............................................21-737 Figure 9.4-2a Turbine Building Ventilation System Air Flow Diagram.......................................21-742 Figure 9.4-2b Turbine Building Ventilation System Control Diagram (Sheets 1-2)....................21-743 Figure 9.4-3 Secondary Containment HVAC System (Sheets 1-3)............................................21-745 Figure 9.4-4 R/B Safety-Related Electrical Equipment HVAC System (Sheets 1-3)................21-748 Figure 9.4-5 Reactor Internal Pump Control Panel Room HVAC System..................................21-751 Figure 9.4-8 Drywell Cooling System P&ID..............................................................................21-752 Figure 9.4-10 Radwaste Building HVAC (Sheets 1-3).................................................................21-753 Chapter 21 Volume 7 List of Figures
Volume 7-ii Chapter 21 Figure TOC 25A5675BH Revision 7 Design Control Document/Tier 2 ABWR Figure 9.5-1 Suppression Pool Cleanup System P&ID...............................................................21-756 Figure 9.5-6 Standby Diesel Generator Fuel Oil and Combustion Air Intake and Exhaust Systems......................................................................................................21-757 Figure 9.5-7 Standby Diesel Generator Jacket Cooling Water System.......................................21-758 Figure 9.5-8 Standby Diesel Generator Starting Air System.......................................................21-759 Figure 9.5-9 Standby Diesel Generator Lubricating Oil System.................................................21-760 Figure 9A.4-1 Reactor Building Fire Protection at Elevation -8200 mm.......................................21-761 Figure 9A.4-2 Reactor Building Fire Protection at Elevation -1700 mm.......................................21-762 Figure 9A.4-3 Reactor Building Fire Protection at Elevation 4800/8500 mm...............................21-763 Figure 9A.4-4 Reactor Building Fire Protection at Elevation 12300 mm......................................21-764 Figure 9A.4-5 Reactor Building Fire Protection at Elevation 18100 mm......................................21-765 Figure 9A.4-6 Reactor Building Fire Protection at Elevation 23500 mm......................................21-766 Figure 9A.4-7 Reactor Building Fire Protection at Elevation 27200 mm......................................21-767 Figure 9A.4-8 Reactor Building Fire Protection at Elevation 31700/38200 mm...........................21-768 Figure 9A.4-9 Reactor Building Fire Protection, Section A-A......................................................21-769 Figure 9A.4-10 Reactor Building Fire Protection, Section B-B.......................................................21-770 Figure 9A.4-11 Control Building Fire Protection, Section B-B.......................................................21-771 Figure 9A.4-12 Control Building Fire Protection at Elevation -8200 mm.......................................21-772 Figure 9A.4-13 Control Building Fire Protection at Elevation -2150 mm.......................................21-773 Figure 9A.4-14 Control Building Fire Protection at Elevation 3500 mm........................................21-774 Figure 9A.4-15 Control Building Fire Protection at Elevation 7900 mm........................................21-775 List of Figures (Continued)
25A5675BH Revision 7 Design Control Document/Tier 2 21-696 ABWR Figure 8.3-1 Electrical Power Distribution System SLD (Sheet 1 of 3)
"
#
#
$
#
!%&&
' ! (
)
#
- % (
+,
#
- ,
- &&
&&
- &&.
#
- &&!.
&
- ,
! &&
! &&
&&
!' &&
- ,
&&
&&
&&
&&
&&
! &&
! &&/
/
- &&
&&
- &&.
#
- &&!.
!
&
!! &&
- ,
&&
!' &&
&&
&&
&&
&&
!&
!
!&
- ,
! &&
! &&
! &&#
- &&
- &&.
#
- &&!.
!
- ,
!
!
&
&&
&&
- ,
! &&
&&
&&
!
!&
!
&
&&
&&
- ,
!
&
0
,
% (
+
% (
+
% (
+
% (
+
&
!- )
.% )
.
& &
%)1
&
!- )
.% )
.
& &
%)1
&
!- )
.% )
.
& &
%)1
#
+
!%+
#
)+
#
)&&
.
!- )
.% )
.
& &
%)1
&
% (
+
2
% (
+
!
&
% )
!
&
&&
&&
&&
&&
2
% (
+
!
&
% )
!
&
&&
&&
&&
&&
2
% (
+
!
&
% )
!
&
&&
&&
&&
!
&
- (
,
% (
+
! &&
! &&
! &&
- ,
- ,
- ,
- ,
#
#
2
)&
.
-+
8& (
- ,
&
0
,
+
+
% (
+
!' &&
% (
+
25A5675BH Revision 7 Design Control Document/Tier 2 21-697 ABWR Figure 8.3-1 Electrical Power Distribution System SLD (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-698 ABWR Figure 8.3-1 Electrical Power Distribution System SLD (Sheet 3 of 3)
EXTERNAL EXTERNAL EXTERNAL
25A5675BH Revision 7 Design Control Document/Tier 2 21-699 ABWR Figure 8.3-2 Instrument and Control Power Supply System SLD
25A5675BH Revision 7 Design Control Document/Tier 2 21-700 ABWR Figure 8.3-3 Plant Vital AC Power Supply System SLD (Sheet 1 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-701 ABWR Figure 8.3-3 Plant Vital AC Power Supply System SLD (Sheet 2 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-702 ABWR Figure 8.3-4 Plant DC Power Supply System SLD (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-703 ABWR Figure 8.3-4 Plant DC Power Supply System SLD (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-704 ABWR Figure 8.3-4 Plant DC Power Supply System SLD (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-705 ABWR Figure 9.1-1 Fuel Pool Cooling and Cleanup System P&ID (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-706 ABWR Figure 9.1-1 Fuel Pool Cooling and Cleanup System P&ID (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-707 ABWR Figure 9.1-1 Fuel Pool Cooling and Cleanup System P&ID (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-708 ABWR Figure 9.1-2 Fuel Pool Cooling and Cleanup System PFD (Sheet 1 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-709 ABWR Figure 9.1-2 Fuel Pool Cooling and Cleanup System PFD (Sheet 2 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-710 ABWR Figure 9.1-12 Plant Refueling and Servicing Sequence
25A5675BH Revision 7 Design Control Document/Tier 2 21-711 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 1 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-712 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 2 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-713 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 3 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-714 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 4 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-715 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 5 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-716 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 6 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-717 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 7 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-718 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 8 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-719 ABWR Figure 9.2-1 Reactor Building Cooling Water System P&ID (Sheet 9 of 9)
25A5675BH Revision 7 Design Control Document/Tier 2 21-720 ABWR Figure 9.2-2 HVAC Normal Cooling Water System P&ID
25A5675BH Revision 7 Design Control Document/Tier 2 21-721 ABWR Figure 9.2-3 HVAC Emergency Cooling Water System P&ID (Sheet 1 of 3)
+(&:$,6'(6,*1('72%(&5266&211(&7('726833257
0&5$5($+9$&&0$18$/02'(23(5$7,2181'(5
32678/$7('$,5&5$)7,03$&76&(1$5,26
)520+(&:&
6+
72+(&:&
6+
25A5675BH Revision 7 Design Control Document/Tier 2 21-722 ABWR Figure 9.2-3 HVAC Emergency Cooling Water System P&ID (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-723 ABWR Figure 9.2-3 HVAC Emergency Cooling Water System P&ID (Sheet 3 of 3) 72+(&:$
6+
6+
)520+(&:$
25A5675BH Revision 7 Design Control Document/Tier 2 21-724 ABWR Figure 9.2-4 Makeup Water System (Condensate) P&ID
25A5675BH Revision 7 Design Control Document/Tier 2 21-725 ABWR Figure 9.2-5 Makeup Water System (Purified) P&ID (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-726 ABWR Figure 9.2-5 Makeup Water System (Purified) P&ID (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-727 ABWR Figure 9.2-5 Makeup Water System (Purified) P&ID (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-728 ABWR Figure 9.2-7 Reactor Service Water System P&ID (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-729 ABWR Figure 9.2-7 Reactor Service Water System P&ID (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-730 ABWR Figure 9.2-7 Reactor Service Water System P&ID (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-731 ABWR Figure 9.3-1 Standby Liquid Control System P&ID
25A5675BH Revision 7 Design Control Document/Tier 2 21-732 ABWR Figure 9.3-1a Standby Liquid Control System PFD
25A5675BH Revision 7 Design Control Document/Tier 2 21-733 ABWR Figure 9.3-6 Instrument Air System P&ID (Sheet 1 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-734 ABWR Figure 9.3-6 Instrument Air System P&ID (Sheet 2 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-735 ABWR Figure 9.3-7 Station Service Air System P&ID (Sheet 1 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-736 ABWR Figure 9.3-7 Station Service Air System P&ID (Sheet 2 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-737 ABWR Figure 9.4-1 Control Building HVAC Flow Diagram (Sheet 1 of 5)
25A5675BH Revision 7 Design Control Document/Tier 2 21-738 ABWR Figure 9.4-1 Control Building HVAC Flow Diagram (Sheet 2 of 5)
0&5$5($+9$&&,6'(6,*1('72%(32:(5(')520
',9,6,21,81'(50$18$/02'(23(5$7,21)25
32678/$7('$,5&5$)7,03$&76&(1$5,26
0&5$5($+9$&&,6'(6,*1('7223(5$7(,1$
0$18$/02'(6833/,(')520+(&:$81'(5
32678/$7('$,5&5$)7,03$&76&(1$5,26
25A5675BH Revision 7 Design Control Document/Tier 2 21-739 ABWR Figure 9.4-1 Control Building HVAC Flow Diagram (Sheet 3 of 5)
25A5675BH Revision 7 Design Control Document/Tier 2 21-740 ABWR Figure 9.4-1 Control Building HVAC Flow Diagram (Sheet 4 of 5)
25A5675BH Revision 7 Design Control Document/Tier 2 21-741 ABWR Figure 9.4-1 Control Building HVAC Flow Diagram (Sheet 5 of 5)
25A5675BH Revision 7 Design Control Document/Tier 2 21-742 ABWR Figure 9.4-2a Turbine Building Ventilation System Air Flow Diagram
25A5675BH Revision 7 Design Control Document/Tier 2 21-743 ABWR Figure 9.4-2b Turbine Building Ventilation System Control Diagram (Sheet 1 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-744 ABWR Figure 9.4-2b Turbine Building Ventilation System Control Diagram (Sheet 2 of 2)
25A5675BH Revision 7 Design Control Document/Tier 2 21-745 ABWR Figure 9.4-3 Secondary Containment HVAC System (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-746 ABWR Figure 9.4-3 Secondary Containment HVAC System (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-747 ABWR Figure 9.4-3 Secondary Containment HVAC System (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-748 ABWR Figure 9.4-4 R/B Safety-Related Electrical Equipment HVAC System (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-749 ABWR Figure 9.4-4 R/B Safety-Related Electrical Equipment HVAC System (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-750 ABWR Figure 9.4-4 R/B Safety-Related Electrical Equipment HVAC System (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-751 ABWR Figure 9.4-5 Reactor Internal Pump Control Panel Room HVAC System
25A5675BH Revision 7 Design Control Document/Tier 2 21-752 ABWR Figure 9.4-8 Drywell Cooling System P&ID
25A5675BH Revision 7 Design Control Document/Tier 2 21-753 ABWR Figure 9.4-10 Radwaste Building HVAC (Sheet 1 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-754 ABWR Figure 9.4-10 Radwaste Building HVAC (Sheet 2 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-755 ABWR Figure 9.4-10 Radwaste Building HVAC (Sheet 3 of 3)
25A5675BH Revision 7 Design Control Document/Tier 2 21-756 ABWR Figure 9.5-1 Suppression Pool Cleanup System P&ID
25A5675BH Revision 7 Design Control Document/Tier 2 21-757 ABWR Figure 9.5-6 Standby Diesel Generator Fuel Oil and Combustion Air Intake and Exhaust Systems
25A5675BH Revision 7 Design Control Document/Tier 2 21-758 ABWR Figure 9.5-7 Standby Diesel Generator Jacket Cooling Water System
25A5675BH Revision 7 Design Control Document/Tier 2 21-759 ABWR Figure 9.5-8 Standby Diesel Generator Starting Air System
25A5675BH Revision 7 Design Control Document/Tier 2 21-760 ABWR Figure 9.5-9 Standby Diesel Generator Lubricating Oil System
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-761 ABWR Figure 9A.4-1 Reactor Building Fire Protection at Elevation -8200 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-762 ABWR Figure 9A.4-2 Reactor Building Fire Protection at Elevation -1700 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-763 ABWR Figure 9A.4-3 Reactor Building Fire Protection at Elevation 4800/8500 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-764 ABWR Figure 9A.4-4 Reactor Building Fire Protection at Elevation 12300 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-765 ABWR Figure 9A.4-5 Reactor Building Fire Protection at Elevation 18100 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-766 ABWR Figure 9A.4-6 Reactor Building Fire Protection at Elevation 23500 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-767 ABWR Figure 9A.4-7 Reactor Building Fire Protection at Elevation 27200 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-768 ABWR Figure 9A.4-8 Reactor Building Fire Protection at Elevation 31700/38200 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-769 ABWR Figure 9A.4-9 Reactor Building Fire Protection, Section A-A
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-770 ABWR Figure 9A.4-10 Reactor Building Fire Protection, Section B-B
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-771 ABWR Figure 9A.4-11 Control Building Fire Protection, Section B-B
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-772 ABWR Figure 9A.4-12 Control Building Fire Protection at Elevation -8200 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-773 ABWR Figure 9A.4-13 Control Building Fire Protection at Elevation -2150 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-774 ABWR Figure 9A.4-14 Control Building Fire Protection at Elevation 3500 mm
25A5675BH Revision 7 Security-Sensitive Information Withhold from Public Disclosure under 10 CFR 2.390 Design Control Document/Tier 2 21-775 ABWR Figure 9A.4-15 Control Building Fire Protection at Elevation 7900 mm