| | | Reporting criterion |
|---|
| 05000029/LER-1982-001, Forwards LER 82-001/03L-0 | Forwards LER 82-001/03L-0 | |
| 05000029/LER-1982-001-03, /03L-0:on 820107,during Surveillance of Low Main Coolant Flow Sys,Relays 1 & 2C in Sys B Failed to Dropout When de-energized.Caused by Burrs on Relay Plunger.Burrs Removed,Upper Bushings Replaced & Clearances Checked | /03L-0:on 820107,during Surveillance of Low Main Coolant Flow Sys,Relays 1 & 2C in Sys B Failed to Dropout When de-energized.Caused by Burrs on Relay Plunger.Burrs Removed,Upper Bushings Replaced & Clearances Checked | |
| 05000029/LER-1982-002-03, /03L-0:on 820316,during Normal Operation,Main Coolant Loop Flow Indication 4 Responded Erratically.Caused by Failure of Amplifier Unit 927D658 Gr 1 Mfg by Westinghouse.Amplifier Will Be Replaced During Next Outage | /03L-0:on 820316,during Normal Operation,Main Coolant Loop Flow Indication 4 Responded Erratically.Caused by Failure of Amplifier Unit 927D658 Gr 1 Mfg by Westinghouse.Amplifier Will Be Replaced During Next Outage | |
| 05000029/LER-1982-002, Forwards LER 82-002/03L-0 | Forwards LER 82-002/03L-0 | |
| 05000029/LER-1982-003, Forwards LER 82-003/03L-0 | Forwards LER 82-003/03L-0 | |
| 05000029/LER-1982-003-03, /03L-0:on 820316,in Mode 1,auxiliary Feedwater Flow Channel 2 Failed.Caused by Failed Power Supply,Model 241A12 Mfg by Power Pac,Inc,Located in Controlotron Series 241 Flow Display Computer.Instrumentation to Be Replaced | /03L-0:on 820316,in Mode 1,auxiliary Feedwater Flow Channel 2 Failed.Caused by Failed Power Supply,Model 241A12 Mfg by Power Pac,Inc,Located in Controlotron Series 241 Flow Display Computer.Instrumentation to Be Replaced | |
| 05000029/LER-1982-004, Forwards LER 82-004/03L-0 | Forwards LER 82-004/03L-0 | |
| 05000029/LER-1982-004-03, /03L-0:on 820320,during Operation in Mode 1, Auxiliary Feedwater Flow Channel 3 Failed.Caused by Failed Power Supply,Model 241A12,in Controlotron Series 241 Flow Display Computer.Instrumentation Will Be Replaced | /03L-0:on 820320,during Operation in Mode 1, Auxiliary Feedwater Flow Channel 3 Failed.Caused by Failed Power Supply,Model 241A12,in Controlotron Series 241 Flow Display Computer.Instrumentation Will Be Replaced | |
| 05000029/LER-1982-006, Forwards LER 82-006/03L-0 | Forwards LER 82-006/03L-0 | |
| 05000029/LER-1982-006-03, /03L-0:on 820420,primary Vent Stack Iodine Radiation Monitor Ratemeter Failed High.Caused by Failure of Air Dryer Due to Moisture.Detector Replaced | /03L-0:on 820420,primary Vent Stack Iodine Radiation Monitor Ratemeter Failed High.Caused by Failure of Air Dryer Due to Moisture.Detector Replaced | |
| 05000029/LER-1982-007-03, /03L-0:on 820420,check Valve HC-V-119 Found Leaking from Inlet & Outlet Flanges.Caused by Relaxation of Bolting for Flanged Mating Surfaces.Bolting Replaced & Torqued | /03L-0:on 820420,check Valve HC-V-119 Found Leaking from Inlet & Outlet Flanges.Caused by Relaxation of Bolting for Flanged Mating Surfaces.Bolting Replaced & Torqued | |
| 05000029/LER-1982-007, Forwards LER 82-007/03L-0 | Forwards LER 82-007/03L-0 | |
| 05000029/LER-1982-008, Forwards LER 82-008/03L-0 | Forwards LER 82-008/03L-0 | |
| 05000029/LER-1982-008-03, /03L-0:on 820504,3 Gpm Leak Found in Underground Fire Main Between Waste Disposal & Primary Auxiliary Bldgs. Isolation of Leak Resulted in Loss of Yard Hydrant 15.Caused by an Improper Gasket to Coupling Seal 1 | /03L-0:on 820504,3 Gpm Leak Found in Underground Fire Main Between Waste Disposal & Primary Auxiliary Bldgs. Isolation of Leak Resulted in Loss of Yard Hydrant 15.Caused by an Improper Gasket to Coupling Seal 1 | |
| 05000029/LER-1982-009, Forwards LER 82-009/03L-0 | Forwards LER 82-009/03L-0 | |
| 05000029/LER-1982-009-03, /03L-0:on 820508,containment Isolation Valve AS-V-719 to Emergency Boiler Feed Pump Found Leaking by Seat.Caused by Poor Valve Seating.Valve Isolated & Lapped & Bonnet Gasket Replaced | /03L-0:on 820508,containment Isolation Valve AS-V-719 to Emergency Boiler Feed Pump Found Leaking by Seat.Caused by Poor Valve Seating.Valve Isolated & Lapped & Bonnet Gasket Replaced | |
| 05000029/LER-1982-010-03, /03L-0:on 820514,during Normal Operation in Mode 1,zone 2 Flow Alarm Sounded.Continuous Flow Revealed Through Alarm Check Auxiliary Valve.Caused by Insufficient Seating.Disc Seal Piece Turned Over | /03L-0:on 820514,during Normal Operation in Mode 1,zone 2 Flow Alarm Sounded.Continuous Flow Revealed Through Alarm Check Auxiliary Valve.Caused by Insufficient Seating.Disc Seal Piece Turned Over | |
| 05000029/LER-1982-010, Forwards LER 82-010/03L-0 | Forwards LER 82-010/03L-0 | |
| 05000029/LER-1982-011-03, /03L-0:on 820521,during Normal Operation in Mode 1,number 4 Steam Generator Blowdown Radiation Monitor Failed Low.Caused by Buildup of Foreign Matl on Electrical Contacts of Circuit Board.Contacts Cleaned | /03L-0:on 820521,during Normal Operation in Mode 1,number 4 Steam Generator Blowdown Radiation Monitor Failed Low.Caused by Buildup of Foreign Matl on Electrical Contacts of Circuit Board.Contacts Cleaned | |
| 05000029/LER-1982-011, Forwards LER 82-011/03L-0 | Forwards LER 82-011/03L-0 | |
| 05000029/LER-1982-012-03, /03L-0:on 820527,repair of 2-inch Carbon Steel Valve VD-V-618 Leak Past Seat Resulted in Isolation of Valve & Steam Generator Blowdown Monitor.Caused by Small Steam Cut Between Seat & Body Threads,Allowing Bypass of Steam | /03L-0:on 820527,repair of 2-inch Carbon Steel Valve VD-V-618 Leak Past Seat Resulted in Isolation of Valve & Steam Generator Blowdown Monitor.Caused by Small Steam Cut Between Seat & Body Threads,Allowing Bypass of Steam | |
| 05000029/LER-1982-012, Forwards LER 82-012/03L-0 | Forwards LER 82-012/03L-0 | |
| 05000029/LER-1982-013-03, /03L-0:on 820527,during Normal Operation in Mode 1 Auxiliary Feedwater Flow Channel Failed.Caused by Failed Power Supply Model 241A12 Due to High Environ Temps.Power Supply Replaced | /03L-0:on 820527,during Normal Operation in Mode 1 Auxiliary Feedwater Flow Channel Failed.Caused by Failed Power Supply Model 241A12 Due to High Environ Temps.Power Supply Replaced | |
| 05000029/LER-1982-013, Forwards LER 82-013/03L-0 | Forwards LER 82-013/03L-0 | |
| 05000029/LER-1982-016-03, /03L-0:on 820611,during Troubleshooting of Malfunction Inside Vaporizer Concentrate Air Particulate Monitor,Signal Cable for Outside Monitor Disconnected.Caused by Personnel Error.Signal Cable Reconnected | /03L-0:on 820611,during Troubleshooting of Malfunction Inside Vaporizer Concentrate Air Particulate Monitor,Signal Cable for Outside Monitor Disconnected.Caused by Personnel Error.Signal Cable Reconnected | |
| 05000029/LER-1982-016, Forwards LER 82-016/03L-0 | Forwards LER 82-016/03L-0 | |
| 05000029/LER-1982-017, Forwards LER 82-017/03L-0 | Forwards LER 82-017/03L-0 | |
| 05000029/LER-1982-017-03, /03L-0:on 820611,NRV Channel B Trip Circuit to NRV-2 Became Inoperable Causing Reduction in Reactor Protective Sys Instrumentation.Caused by Failure of Faulty Fusetron 2 Amp Indicating Fuse.Fuse Replaced | /03L-0:on 820611,NRV Channel B Trip Circuit to NRV-2 Became Inoperable Causing Reduction in Reactor Protective Sys Instrumentation.Caused by Failure of Faulty Fusetron 2 Amp Indicating Fuse.Fuse Replaced | |
| 05000029/LER-1982-019-03, /03L-0:on 820629,voltage Surges on 115-kV Lines During Thunderstorm Resulted in Loss of Z 126 Line & Loss of Flow Scram.Caused by Lightning Strike on 115-kV Line During Storm.Line Restored to Svc | /03L-0:on 820629,voltage Surges on 115-kV Lines During Thunderstorm Resulted in Loss of Z 126 Line & Loss of Flow Scram.Caused by Lightning Strike on 115-kV Line During Storm.Line Restored to Svc | |
| 05000029/LER-1982-019, Forwards LER 82-019/03L-0 | Forwards LER 82-019/03L-0 | |
| 05000029/LER-1982-020, Forwards LER 82-020/03L-0 | Forwards LER 82-020/03L-0 | |
| 05000029/LER-1982-020-03, /03L-0:on 820629,during Testing of Nonreturn Valve Tripping Sys,Valve 3 Failed to Close on Actuation of Train A.Caused by Failure of Main Dump Solenoid Valve.Valve Replaced W/Improved Model.Remaining Valves Will Be Replaced | /03L-0:on 820629,during Testing of Nonreturn Valve Tripping Sys,Valve 3 Failed to Close on Actuation of Train A.Caused by Failure of Main Dump Solenoid Valve.Valve Replaced W/Improved Model.Remaining Valves Will Be Replaced | |
| 05000029/LER-1982-024, Has Been Canceled | Has Been Canceled | |
| 05000029/LER-1982-032, Has Been Canceled | Has Been Canceled | |
| 05000029/LER-1982-037, Forwards LER 82-037/03L-0 | Forwards LER 82-037/03L-0 | |
| 05000029/LER-1982-037-03, /03L-0:on 821016,while Performing Type C Tests, TV-204 Determined to Be Leaking Past Seat.Cause Not Determined.Valve Disassembled for Insp & Cleaning | /03L-0:on 821016,while Performing Type C Tests, TV-204 Determined to Be Leaking Past Seat.Cause Not Determined.Valve Disassembled for Insp & Cleaning | |
| 05000029/LER-1982-044, Forwards LER 82-044/03L-0 | Forwards LER 82-044/03L-0 | |
| 05000029/LER-1982-044-03, /03L-0:on 821208,continuous Flow Discovered Through Alarm Check Auxiliary Valve After Special Hazards Header Flow Alarm Received.Caused by Insufficient Seating Between Auxiliary Valve Seat & Disc.Valve Disc Replaced | /03L-0:on 821208,continuous Flow Discovered Through Alarm Check Auxiliary Valve After Special Hazards Header Flow Alarm Received.Caused by Insufficient Seating Between Auxiliary Valve Seat & Disc.Valve Disc Replaced | |