FRN - Notice of Availability of EA-FONSI for Limerick Exemption
ML24107A922
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 05/03/2024
From: Yoira Diaz-Sanabria
Storage and Transportation Licensing Branch
To:
Constellation Energy Generation
Shared Package
ML24107A918 List:
References
NRC-2024-0083, 89 FR 38921 2024-10044
Download: ML24107A922 (1)


Text

[7590- 01-P]

NUCLEAR REGULATORY COMMISSION

[Docket Nos. 72-65, 50- 352, and 50- 353; NRC-2024- 0083]

Constellation Energy Generation, LLC.;

Limerick Generating Station, Units 1 and 2;

Independent Spent Fuel Storage Installation;

Environmental Assessment and Finding of No Significant Impact

AGENCY: Nuclear Regulatory Commission.

ACTION: Notice; issuance.

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) is issuing an

environmental assessment (EA) and a finding of no significant impact (FONSI) for an

exemption request submitted by Constellation Energy Generation, LLC (Constellation)

that would permit the Limerick Generating Station (LGS) to maintain three loaded and to

load five new 89 multi-purpose canisters (MPC) with continuous basket shims (CBS) in

the HI-STORM Flood/Wind (FW) MPC Storage System at its LGS Units 1 and 2

Independent Spent Fuel Storage Installation (ISFSI) in a storage condition where the

terms, conditions, and specifications in the Certificate of Compliance (CoC) No. 1032,

Amendment No. 1, Revision No. 1, are not met.

DATES: The EA and FONSI referenced in this document are available on May 8, 2024.

ADDRESSES: Please refer to Docket ID NRC-2024- 0083 when contacting the NRC

about the availability of information regarding this document. You may obtain publicly

available information related to this document using any of the following methods:

search for Docket ID NRC-2024- 0083. Address questions about D ocket IDs in

Regulations.gov to Stacy Schumann; telephone: 301-415- 0624; email:

Stacy.Schumann@nrc.gov. For technical questions, contact the individual listed in the

For Further Information Contact section of this document.

  • NRCs Agencywide Documents Access and Management System

(ADAMS): You may obtain publicly available documents online in the ADAMS Public

Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the

search, select Begin Web-based ADAMS Search. For problems with ADAMS, please

contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, at

301-415-4737, or by email to PDR. Resource@nrc.gov. For the convenience of the

reader, instructions about obtaining materials referenced in this document are provided

in the Availability of Documents section.

  • NRCs PDR: The PDR, where you may examine and order copies of publicly

available documents, is open by appointment. To make an appointment to visit the PDR,

please send an email to PDR.Resource@nrc.gov or call 1-800-397-4209 or 301-415-

4737, between 8 a.m. and 4 p.m. eastern time (ET), Monday through Friday, except

Federal holidays.

FOR FURTHER INFORMATION CONTACT: Christian Jacobs, Office of Nuclear

Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC

20555; telephone: 301-415-6825; email: Christian.Jacobs@nrc.gov.

SUPPLEMENTARY INFORMATION:

I. Introduction

The NRC is reviewing an exemption request from Constellation, dated

April 5, 2024. Constellation is requesting an exemption, pursuant to section 72.7 of title

10 of the Code of Federal Regulations (10 CFR), in paragraphs 72.212(a)(2),

72.212(b)(3), 72.212(b)(5)(i), 72.212(b)(11), and 72.214 that require Constellation to

comply with the terms, conditions, and specifications of the C oC No. 1032, Amendment

2 No. 1, Revision No. 1. If approved, the exemption would allow Constellation to maintain

three loaded and to load five new MPC CBS in the HI-STORM FW MPC Storage

System at the LGS ISFSI in a storage condition where the terms, conditions, and

specifications in the CoC No. 1032, Amendment No. 1, Revision No. 1, are not met.

II. Environmental Assessment

=

Background===

The LGS is located in Limerick Township of Montgomery County, Pennsylvania,

1.7 miles (2.7 kilometers) southeast of the Borough of Pottstown. Unit 1 began operating

in 1986 and Unit 2 began operating in 1990. Constellation has been storing spent fuel in

an ISFSI at the LGS under a general license as authorized by 10 CFR p art 72, subpart

K, General License for Storage of Spent Fuel at Power Reactor Sites. Constellation

currently uses the HI -STORM FW MPC Storage System under CoC No. 1032,

Amendment No. 1, Revision No. 1, for dry storage of spent nuclear fuel in a specific

MPC (i.e., MPC-89) at the LGS ISFSI.

Description of the Proposed Action

The CoC is the NRC approved design for each dry cask storage system. The

proposed action would exempt the applicant from the requirements of

10 CFR 72.212(a)(2), 72.212(b)(3), 72.212(b)(5)(i), 72.212(b)(11), and 72.214 only as

these requirements pertain to the use of the MPC CBS in the HI-STORM FW MPC

Storage System for the three already loaded systems and the near-term planned loading

of five new canisters. The exemption would allow Constellation to maintain loaded and to

load five new MPC-89-CBS in the HI-STORM FW MPC Storage System at the LGS

ISFSI, despite the MPC CBS in the HI-STORM FW MPC Storage System not being

in compliance with the terms, conditions, and specifications in the CoC No. 1032,

Amendment No. 1, Revision No. 1.

3 The HI-STORM FW MPC Storage System CoC provides the requirements,

conditions, and operating limits necessary for use of the system to store spent fuel.

Holtec International (Holtec), the designer and manufacturer of the HI -STORM FW MPC

Storage System, developed a variant of the design with CBS for the MPC-89, known as

MPC CBS. Holtec originally implemented the CBS variant design under the

provisions of 10 CFR 72.48, Changes, tests, and experiments, which allows licensees

to make changes to cask designs without a CoC amendment under certain conditions

(listed in 10 CFR 72.48(c)). After evaluating the specific changes to the cask designs,

the NRC determined that Holtec erred when it implemented the CBS variant design

under 10 CFR 72.48, as this was not the type of change allowed without a CoC

amendment. For this reason, the NRC issued three Severity Level IV violations to

Holtec. Prior to the issuance of the violations, Constellation had already loaded three

MPC CBS in a HI -STORM FW MPC Storage System, which are safely in storage on

the LGS ISFSI pad. Additionally, Constellation plans to load five new MPC CBS in

the HI-STORM FW MPC Storage System beginning in August 2024. This exemption

considers the storage of the already loaded systems and the near-term planned loading

of the five canisters with the CBS variant basket design.

Need for the Proposed Action

Constellation requested this exemption because Constellation is currently out of

compliance with NRC requirements, resulting from the previous loading of spent fuel into

a storage system with the CBS variant basket design. This exemption would allow three

already loaded MPC CBS in the HI -STORM FW MPC Storage System to remain in

storage at the LGS ISFSI. The applicant also requested the exemption in order to allow

the LGS to load five new MPC CBS in HI -STORM FW MPC Storage System at the

LGS ISFSI for the future loading campaign beginning in August 2024.

4 Approval of the exemption request would allow Constellation to effectively

manage the spent fuel pool margin and capacity to enable refueling and offloading fuel

from the reactor. It would also allow Constellation to effectively manage the availability of

the specialized workforce and equipment needed to support competing fuel loading and

operational activities at the LGS and other Constellation sites.

Environmental Impacts of the Proposed Action

This EA evaluates the potential environmental impacts of granting an exemption

from the terms, conditions, and specifications in CoC No. 1032, Amendment No. 1,

Revision No. 1. The exemption would allow three loaded MPC CBS in the HI-STORM

FW MPC Storage System to remain loaded at the LGS ISFSI. The exemption also would

allow a near -term loading of five new MPC CBS in the HI -STORM FW MPC Storage

System and allow the MPC CBS to be maintained in storage at the LGS ISFSI.

The potential environmental impacts of storing spent nuclear fuel in NRC-

approved storage systems have been documented in previous assessments. On

July 18, 1990, the NRC amended 10 CFR part 72 to provide for the storage of spent fuel

under a general license in cask designs approved by the NRC. The EA for the 1990 final

rule analyzed the potential environmental impacts of using NRC-approved storage

casks. The EA for the HI-STORM FW MPC Storage System, CoC No. 1032,

Amendment No. 1, Revision No. 1, published in 2015, tiers off of the EA issued for the

July 18, 1990, final rule. Tiering off earlier EAs is a standard process encouraged by

the regulations implementing the National Environmental Policy Act of 1969 (NEPA) that

entails the use of impact analyses of previous EAs to bound the impacts of a proposed

action where appropriate. The Holtec HI -STORM FW MPC Storage System is designed

to mitigate the effects of design basis accidents that could occur during storage.

Considering the specific design requirements for the accident conditions, the design of

5 the cask would prevent loss of containment, shielding, and criticality control. If there is

no loss of containment, shielding, or criticality control, the environmental impacts would

not be significant.

The exemptions requested by Constellation at the LGS site as they relate to CoC

No. 1032, Amendment No. 1, Revision No. 1, for the HI -STORM FW MPC Storage

System are limited to the use of the CBS variant basket design only for the already

loaded three canisters and near-term planned loading of five canisters utilizing the CBS

variant basket design. The staff has determined that this change in the basket will not

result in either radiological or non-radiological environmental impacts that significantly

differ from the environmental impacts evaluated in the environmental assessment

supporting the issuance of CoC No. 1032, Amendment No. 1, Revision No. 1. If the

exemption is granted, there will be no significant change in the types or amounts of any

effluents released, no significant increase in individual or cumulative public or

occupational radiation exposure, and no significant increase in the potential for or

consequences from radiological accidents. Accordingly, the Commission concludes that

there would be no significant environmental impacts associated with the proposed

action.

Alternative to the Proposed Action

The staff considered the no-action alternative. The no -action alternative (denial of

the exemption request) would require Constellation to unload spent fuel from the MPC-

89-CBS in the HI-STORM FW MPC Storage System to bring it in compliance with the

CoC terms, conditions, and specifications in the CoC No. 1032, Amendment No. 1,

Revision No. 1. Unloading the cask would subject station personnel to additional

radiation exposure, generate additional contaminated waste, increase the risk of a

possible fuel handling accident, and increase the risk of a possible heavy load handling

6 accident. Furthermore, the removed spent fuel would need to be placed in the spent fuel

pool, where it would remain until it could be loaded into an approved storage cask. Delay

in the loading of this spent fuel into other casks could affect Constellations ability to

effectively manage the spent fuel pool capacity and reactor fuel offloading. Not allowing

the planned future loading campaign could also affect Constellations ability to manage

pool capacity, reactor fuel offloading, and refueling. It could also pose challenges to

spent fuel heat removal and impact the availability of the specialized workforce and

equipment needed to support competing fuel loading and operational activities at the

LGS and other Constellation sites. The NRC has determined that the no-action

alternative would result in undue potential human health and safety impacts that could

be avoided by proceeding with the proposed exemption, especially given that the staff

has concluded in NRCs Safety Determination Memorandum, issued with respect to the

enforcement action against Holtec regarding these violations, that fuel can be stored

safel y in the MPC-89-CBS canisters.

Agencies Consulted

The NRC provided the Pennsylvania Department of Environmental Protection

(PDEP) a copy of this draft EA for review by an email dated April 29, 2024. On May 1,

2024, PDEP provided its concurrence by email.

III. Finding of No Significant Impact

The environmental impacts of the proposed action have been reviewed in

accordance with the requirements in 10 CFR part 51, which implement NEPA. Based

upon the foregoing e nvironmental assessment, the NRC finds that the proposed action

of granting the exemption from the regulations in 10 CFR 72.212(a)(2), 72.212(b)(3),

72.212(b)(5)(i), 72.212(b)(11) and 72.214, which require the licensee to comply with the

terms, conditions, and specifications of the CoC, in this case limited to past and specific

7 future loadings of baskets with the CBS variant design, would not significantly impact the

quality of the human environment. Accordingly, the NRC has determined that a FONSI is

appropriate, and an environmental impact statement is not warranted.

IV. Availability of Documents

The documents identified in the following table are available to interested

persons through ADAMS, as indicated.

Document Description ADAMS Accession No. or Federal Register notice Constellations request for exemption, dated ML24096A137 April 5, 2024.

NRC issuance of Certificate of Compliance No.

1032, Amendment No. 1, Revision No. 1, dated ML15152A358 (Package)

May 29, 2015.

Holtec International, Inc. - Notice of Violation; The U.S. Nuclear Regulatory Commission Inspection ML24016A190 Report No. 07201014/2022-201, EA-23- 044, dated January 30, 2024.

10 CFR part 72 amendment to allow spent fuel 55 FR 29181 storage in NRC-approved casks, July 18, 1990.

EA for part 72 amendment to allow spent fuel storage in NRC-approved casks, dated ML051230231 March 8, 1989.

List of Approved Spent Fuel Storage Casks: HI-STORM 100 Cask System CoC No. 1032, 80 FR 14291 Amendment No. 1, Revision 1, dated March 19, 2015.

NRC Safety Determination of a Potential Structural Failure of the Fuel Basket During Accident Conditions for the HI-STORM 100 and HI-STORM ML24018A085 Flood/Wind Dry Cask Storage Systems, dated January 31, 2024.

NRC email to PDEP requesting review of EA/FONSI for LGS Exemption, dated April 29, ML24122C670 2024.

8 Email response from PDEP regarding EA/FONSI ML24122C674 for LGS Exemption, dated May 1, 2024.

Dated: May 3, 2024.

For the Nuclear Regulatory Commission.

/RA/

Yoira Diaz-Sanabria, Chief, Storage and Transportation Licensing Branch,

Division of Fuel Management, Office of Nuclear Material Safety and Safeguards.

9