ENS 56458
From kanterella
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
ENS Event | |
|---|---|
00:52 Apr 8, 2023 | |
| Title | High Pressure Core Injection (HPCI) System Inoperable |
| Event Description | The following information was provided by the licensee via email:
At 2052 EDT on April 7, 2023, during routine system preventative maintenance functional testing, the Unit 1 HPCI turbine stop valve, FV-15612, remained in the intermediate position. This failure resulted in the Unit 1 HPCI system being inoperable. This is being reported as a loss of an entire safety function condition in accordance with 10 CFR 50.72(b)(3)(v)(D). The NRC Resident Inspector was notified. The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: The Unit 1 HPCI inoperability places Unit 1 in a 14-day Technical Specification (TS) Limiting Condition for Operation (LCO). |
| Where | |
|---|---|
| Susquehanna Pennsylvania (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| LER: | 05000387/LER-2023-002 Unplanned Lnoperability of the High Pressure Coolant Injection (HPCI) System Due Failure of the HPCI Turbine Stop Valve to Fully Close Most Likely Due to Internal Corrosion and |
| Time - Person (Reporting Time:+0.12 h0.005 days <br />7.142857e-4 weeks <br />1.64376e-4 months <br />) | |
| Opened: | Tom Rydzewski 00:59 Apr 8, 2023 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Apr 8, 2023 |
| 56458 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |