Informs of Finalized Case Study Rept, Review of Motor- Operated Valve Performance, Concluding Current Procedures at Plants Inadequate to Assure Valve Operation.Rept Also Serves as AEOD Response to 850805 EDO Memo Re NUREG-1154
ML20215E589
Person / Time
Issue date: 12/05/1986
From: Heltemes C
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
To: Beckjord E, Harold Denton, Grace J, Murley T, Taylor J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II), NRC OFFICE OF INSPECTION & ENFORCEMENT (IE), Office of Nuclear Reactor Regulation, NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
Shared Package
ML20215E592 List:
References
RTR-NUREG-1154 NUDOCS 8612230022
Download: ML20215E589 (2)


Text

G. ~

<= D cember 5, 1986 MEMORANDUM FOR: Harold R. D:nton, Diractor Office of Nuclear Reactor Regulation AE0D/C603 James M. Taylor, Director Office of Inspection and Enforcement Eric S. Beckjord, Director Office of Nuclear Regulatory Research Thomas E. Murley, Regional Administrator, Region I J. Nelson Grace, Regional Administrator, Region II James G. Keppler, Regional Administrator, Region III Robert D. Martin, Regional Administrator, Region IV .

John B. Martin, Regional Administrator,. Region V FROM: C. J. Heltemes, Jr., Director Office for Analysis and Evaluation of Operational Data

SUBJECT:

CASE STUDY REPORT - A REVIEW 0F.M0 TOR-0PERATED val.VE PERFORMANCE The Office for Analysis and Evaluation of Operational Data '(AE0D) has finalized its case study on a review of motor-operated valve performance. .The final report addresses the peer review comments provided by NRR, IE, RES, the Regions, INP0, NSAC, M0 VATS Inc., and Toledo Edison Company. The report brings together previous NRC studies and other related documents (AE0D reports and IE bulletins, circulars, and information notices), reviews approximately 1200 valve operator events from 1981 to mid-1985, and incorporates new data from an NRC valve testing program that utilized' signature tracing techniques on valve assemblies in operating plants. This report also serves as the AE0D response to staff action item 6(1) of the August 5, 1985 ED0 memorandum: " Staff.

Actions Resulting from the investigation of the Davis-Besse Event (NUREG-1154)".

Our case study report concludes that current methods and procedures-at many operating plants are not adequate to assure that valves will operate when .

needed. Furthermore, the deficiencies would generally not be detected by f

%) f

9) ()0 8612230022 861205 PDR ORO NEXD $
  1. ~ Multiple Addr:ss u s existing (plant proceduras intended to assure operability, such as surveillance testing) testing or plant technical plant operatorspecifications observations.and ASME Thus, Code, Section assurance of valve XI inservice operability appears to be strongly dependent upon diagnostic capability to assess and evaluate failures to operate so that root causes of failure--including switch setpoints--are correctly determined and proper changes implemented. Further, the issue of valve assembly performance and reliability is a complex subject that involves several technical disciplines. The report makes four recommendations.

In view of the common NRC and industry objective of resolving identified safety issues relating to operation of nuclear plants in the most effective manner, we understand that the ED0 will request that NUMARC undertake appropriate industry wide initiatives to address the findings, conclusions and recommendations in the AE0D case study. The report is being transmitted to appropriate NRC offices for information and possible future NRC action if an effective industry improvement program is not undertaken and implemented in a timely manner.

If you have any questions regarding the enclosed report, please contact Earl J. Brown of my staff. Dr. Brown can be reached on 492-4437.

ons>ss spent c J.Hanumen.*-

C. J. Heltemes, Jr., Director Office for Analysis and Evaluation of Operational Data

Enclosure:

As stated cc w/ enclosure: J. Sniezek, DEDR0GR V. Stello, ED0 J. Richardson, RES R. Vollmer, NRR J. Vora, RES R. Bernero, NRR G. Weidenhamer, RES F. Miraglia, NRR E. Jordan, IE H. Thompson, NRR R. Baer, IE T. Speis, NRR R. Kiessel, IE R. Bosnak, NRR J. Stolz, NRR L. Marsh, NRR A. DeAgazio, NRR B. Liaw, NRR I. Jackiw, RIII R. Ballard, NRR P. Wohld, RIII F. Cherney, NPR W. Russell, NRR J. Page, NRR H. Booher, NRR G. Arlotto, RES W. Farmer, RES DISTRIBUTION:

6 38 PBaranowsky Wi.anning AE0D CF Plam KBlack ROAB SF EBrown MWilliams ROAB CF MChiramal DHumenansky, OCM SRubin FHebdon CHeltemes, Jr. AE0D SF 0FC :ROA :ROAB:SC L :ROAB:BC :AEOD:DD :AE00:D  :  :

_ _ _ _ _ : _ f. _____:-_______ W. . . 4, . p ______:____________:___________

NAME :EBr wn:nc :MChiramal :SRubin :FHebdon :CJyltemes :  :

DATE:12/'//86 :12/l4/86

12/ 4 /86 :12/ 5'/86 :12/(/86  :  :

0FFICIAL RECORD COPY 1