ML20204F434
From kanterella
ML20204F434 | |
Person / Time | |
---|---|
Site: | 05000113 |
Issue date: | 10/17/1988 |
From: | ARIZONA, UNIV. OF, TUCSON, AZ |
To: | |
Shared Package | |
ML20204F348 | List: |
References | |
NUDOCS 8810210577 | |
Download: ML20204F434 (4) | |
Similar Documents at 05000113 | |
---|---|
Category:OPERATOR TRAINING/REQUALIFICATION PROGRAM
MONTHYEARML20248A9711989-09-15015 September 1989
[Table view]Rev 1 to Operator & Senior Operator Requalification Program for Univ of Arizona Research Reactor ML20204F4341988-10-17017 October 1988 Operator & Senior Operator Requalification Program 1989-09-15 Category:TEXT-SAFETY REPORT MONTHYEARML20211G5341999-06-30030 June 1999
[Table view]Submits Annual Rept, Covering Period 980701 Through 990630 for Activities of Triga Mark I Reactor.With ML20209A7181999-06-22022 June 1999 Special Rept:On 990607,compliance with Spec 4.6 Was Not Enforced in Procedure Number Uarr 155,monthly Checklist, During Review of TS & Procedures.Caused by Omission of Item from Monthly Checklist.Prepared Revised Version of Uarr 155 ML20196B6021998-11-25025 November 1998 Ro:On 901206,950424 & 970512,deficiencies Occurred in Shipping & Receiving Special Nuclear Matl.Caused by Misunderstanding of Procedure Uarr 127.Committee Discussed Matter in 981103 Meeting & Matter Was Described in Training ML20237C9921998-06-30030 June 1998 Annual Rept Covering Period 970101-980630 for Activities of Triga Mark I at Univ of Az,Tucson,Az.Supporting Documentation,Encl ML20198B2201997-12-18018 December 1997 Safety Evaluation Supporting Amend 17 to License R-52 ML20199F1971997-11-13013 November 1997 Deficiency Rept Re Malfunction of Mode Selector Switch. Action Will Be Reviewed by Reactor Committee for Facility ML20199B6341997-11-13013 November 1997 Ro:On 971104,malfunction of Mode Switch in Pulse Mode Occurred.Caused by Failure of Mode Switch to Reliably Switch Between Normal & High Range Signals.Removed Rear Casing of Mode Switch & Applied Switch Cleaning Fluid ML20198P2541997-11-0505 November 1997 Ro:On 971104,change of Mode Switch from Manual to Pulse Positions Did Not Reliably Switch Between Normal & High Range Signals.Caused by Malfunction of Switch.Applied Switch Cleaning Fluid to Switch ML20217D1681997-10-0101 October 1997 Ro:On 970930,discovered That Reactor Power Calibr Showed Safety Channels Reading Lower than Actual Power.Cause Indeterminate.Recalibr Power Channels & Issued Instructions to Set Scrams More Conservatively Pending Investigation ML20216D4731997-08-13013 August 1997 Annual Rept Covering Period Jul 1996-June 1997,for Activities of Triga Mark I Reactor at Univ of Az,Tucson,Az ML20128P6211996-10-16016 October 1996 Rs:On 960919,reactor Started Up & Operated by RO W/O SRO Supervision.Caused by Personnel Error & Misinterpretation of Procedural Requirements.Ro License Suspended.Procedure Uarr 163 Revised ML20059E8061990-08-29029 August 1990 Annual Rept for License R-52 for Jul 1989 - June 1990 ML20248A9711989-09-15015 September 1989 Rev 1 to Operator & Senior Operator Requalification Program for Univ of Arizona Research Reactor ML20246N7601989-08-31031 August 1989 Annual Rept Covering Period Jul 1988 - June 1989 for Activities of Triga Mark I Reactor ML20204F5311988-10-19019 October 1988 SAR Univ of Arizona Triga Mark I Research Reactor ML20204F4341988-10-17017 October 1988 Operator & Senior Operator Requalification Program ML20209H5671986-08-27027 August 1986 Annual Rept for Triga Mark I Reactor at Univ of Arizona,Jul 1985 - June 1986 ML20135A9281985-08-26026 August 1985 Annual Rept for Jul 1984 - June 1985 1999-06-30 |
Text
Retrieved from "https://kanterella.com/w/index.php?title=ML20204F434&oldid=3026963"