Semantic search
Jump to navigation
Jump to search
Issue date | Title | Topic | |
---|---|---|---|
ML20211G534 | 30 June 1999 | Submits Annual Rept, Covering Period 980701 Through 990630 for Activities of Triga Mark I Reactor.With | |
ML20209A718 | 22 June 1999 | Special Rept:On 990607,compliance with Spec 4.6 Was Not Enforced in Procedure Number Uarr 155,monthly Checklist, During Review of TS & Procedures.Caused by Omission of Item from Monthly Checklist.Prepared Revised Version of Uarr 155 | |
ML20196B602 | 25 November 1998 | Ro:On 901206,950424 & 970512,deficiencies Occurred in Shipping & Receiving Special Nuclear Matl.Caused by Misunderstanding of Procedure Uarr 127.Committee Discussed Matter in 981103 Meeting & Matter Was Described in Training | |
ML20237C992 | 30 June 1998 | Annual Rept Covering Period 970101-980630 for Activities of Triga Mark I at Univ of Az,Tucson,Az.Supporting Documentation,Encl | |
ML20198B220 | 18 December 1997 | Safety Evaluation Supporting Amend 17 to License R-52 | |
ML20199F197 | 13 November 1997 | Deficiency Rept Re Malfunction of Mode Selector Switch. Action Will Be Reviewed by Reactor Committee for Facility | |
ML20199B634 | 13 November 1997 | Ro:On 971104,malfunction of Mode Switch in Pulse Mode Occurred.Caused by Failure of Mode Switch to Reliably Switch Between Normal & High Range Signals.Removed Rear Casing of Mode Switch & Applied Switch Cleaning Fluid | |
ML20198P254 | 5 November 1997 | Ro:On 971104,change of Mode Switch from Manual to Pulse Positions Did Not Reliably Switch Between Normal & High Range Signals.Caused by Malfunction of Switch.Applied Switch Cleaning Fluid to Switch | |
ML20217D168 | 1 October 1997 | Ro:On 970930,discovered That Reactor Power Calibr Showed Safety Channels Reading Lower than Actual Power.Cause Indeterminate.Recalibr Power Channels & Issued Instructions to Set Scrams More Conservatively Pending Investigation | |
ML20216D473 | 13 August 1997 | Annual Rept Covering Period Jul 1996-June 1997,for Activities of Triga Mark I Reactor at Univ of Az,Tucson,Az | |
ML20128P621 | 16 October 1996 | Rs:On 960919,reactor Started Up & Operated by RO W/O SRO Supervision.Caused by Personnel Error & Misinterpretation of Procedural Requirements.Ro License Suspended.Procedure Uarr 163 Revised | Earthquake |
ML20059E806 | 29 August 1990 | Annual Rept for License R-52 for Jul 1989 - June 1990 | |
ML20248A971 | 15 September 1989 | Rev 1 to Operator & Senior Operator Requalification Program for Univ of Arizona Research Reactor | |
ML20246N760 | 31 August 1989 | Annual Rept Covering Period Jul 1988 - June 1989 for Activities of Triga Mark I Reactor | Boric Acid |
ML20204F531 | 19 October 1988 | SAR Univ of Arizona Triga Mark I Research Reactor | |
ML20204F434 | 17 October 1988 | Operator & Senior Operator Requalification Program | |
ML20209H567 | 27 August 1986 | Annual Rept for Triga Mark I Reactor at Univ of Arizona,Jul 1985 - June 1986 | |
ML20135A928 | 26 August 1985 | Annual Rept for Jul 1984 - June 1985 |