- Dave Morey Southern Nuclear V:ce President Operating Company Farley Project P0. Box 1295 Birmingham, Alabama 35201 Tel 205 992.5131 SOUTHERNk h COMPANY May 9, 1997 Energy to ServeYourWorld" Docket Nos. 50-348 50-364 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D C 20555 Joseph M. Farley Nuclear Plant Monthly Operating Report Ladies and Gentlemen:
Attached are the April 1997 Monthly Operating Reports for Joseph M. Farley Nuclear Plant Units 1 and 2, as required by Section 6.9.1.10 of the Technical Specifications.
If you have any questions, please advise.
Respectfully submitted, f )htti Dave Morey RWC:(mor)
I Attachments
)
cc: Mr. L. A. Reyes, Region II Administrator /
Mr. J.1. Zimmerman, NRR Project Manager
) [k Mr. T. M. Ross, FNP Sr. Resident inspector 9705200401 970430 PDR ADOCK 05000348 R PDR kf
Joseph M. Farley Nuclear Plant Unit I
! Narrative Summary of Operations l l April 1997 l,
t
. The fourteenth refueling outage continued through the month of April.
The following major safety related maintenance was performed during the month:
- 1. 18 month maintenance outage was performed on the 1B Diesel Generator. This .
included replacing the tube bundles for the jacket water and lube oil heat ;
exchangers.
~
The following maintenance was associated with outage activities:
- 1. The reactor was refueled. ;
- 2. Performed pressure pulse and sludge lance cleaning of secondary side of the !
steam generators. Test and inspection activities continued on the primary side of the steam generators.
- 3. Performed a reactor vessel inservice inspection.
{
- 4. Replaced 38 of 48 Containment Cooler cooling coils.
- 5. Replaced the IC Reactor Coolant Pump stator.
- 6. Modifications to remove the Boron Injection Tank and Spray Additive Tank j were completed.
h i
OPERATING DATA REPORT l DOCKET NO. 50-348 l DATE May 5,1997 i COMPLETED BY M. W. McAnulty TELEPHONE (334) 899-5156, ext.3640 OPERATING STATUS
- 1. Unit Name: Joseph M. Farley - Unit 1 Notes
- 2. Reporting Period: April 1997 1) Cumulative data since 12-01-77,
- 3. Licensed Thermal Power (MWt): 2,652 date of commercial operation.
- 4. Nameplate Rating (Gross MWe): 860
- 5. Design Electrical Rating (Net MWe): 829
- 6. Maximum Dependable Capacity (Gross MWe): 866
- 7. Maximum Dependable Capacity (Net MWe): 822
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Smce Last Report, Give Reasons: N/A
- 9. Power Level To Which Restricted, If Any (Net MWe): N/A
- 10. Reasons For Restrictions, if Any: N/A This Month Yr. to Date Cumulative
- 11. Hours in Reporting Period 719.0 2,879.0 170,183.0
- 12. Number Of Hours Reactor Was Critical 0.0 1,752.6 137,197.3
- 13. Reactor Reserve Shutdown Hours 0.0 0.0 3,650.0
- 14. Hours Generator On-line 0.0 1,752.5 135,168.2
- 15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
- 16. Gross Thermal Energy Generated (MWH) 0.0 4,511,632.6 348,230,639.0
- 17. Gross Electrical Energy Generated (MWH) 0.0 1,474,852.0 112,486,430.0
- 18. Net Electrical Energy Generated (MWH) (4,236.0) 1,390,856.0 106,272,812.0 ;
- 19. Unit Service Factor 0.0 60.9 79.4 l
- 20. Unit Availability Factor 0.0 60.9 79.4 )
- 21. Unit Capacity Factor (Using MDC Net) 0.0 58.8 76.7 l 58.3 75.3 l
- 22. Unit Capacity Factor (Using DER Net) 0.0
- 23. Unit Forced Outage Rate 0.0 0.0 5.5
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
4
- 25. If Shut Down at End Of Report Period, Estimated Date of Startup: 05/26/97
- 26. Units In Test Status (Prior To Commercial Operation): Forecast Achieved Initial Criticality 08/06n7 08/0907 Initial Electricity 08/20n7 08/l8/77 Commercial Operation 12/0167 12/0107
. DOCKET NO. 50-348 UNIT 1 DATE May 5,1997 COMPLETED BY _ M. W. McAnulty_
TELEPHONE (334) 899-5156 ext 3640 2.
MONTII April DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 0 17 0 2 0 18 0 I 3 0 19 0 4 0 20 0
.5 0 21 0 6 0 22 0 7 0 23 0 8 0 24 0 9 0 25 0 10 0 26 0 11 0 27 0 12 0 28 0 13 0 29 0 14 0 30 0 15 0 31 N/A 16 0 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting period. Compute to the nearest whole megawatt.
l
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-348 UNIT NAME J. M. Farley - Unit 1 DATE May 5,1997 COMPLETED BY M. W. McAnuity REPORT MONTH April TELEPHONE (334) 899-5156, ext.3640
=.=:w-E E S T A T Y Y S 11 SC
~
P O O TO CAUSE AND CORRECTIVE E DURATION N D ED COMPONENT ACT10N TO NO. DATE (1) (llOURS) (2) (3) LER # ME CODE (5) PREVENT RECURRENCE i
- - . --- - ...L --
.n ~
from 970315.
L ._ _ _ _ _ _
I l
1: 2: 3: EVENTS REPORTED
. F: Forced Reason Method INVOLVE A S: Scheduled A . Equipment Failure (Explain) 1 Manual GREATER TilAN 20%
B Maintenance or Ten 2 ManualScram REDUCTION IN C. Refueling 3 - Automatic Scram AVERAGE DAILY ,
D. Regulatory Restriction 4 Other(Explain) POWER LEVEL FOR E Opermot Training A 1.icense Examinmion Tile PRECEDINO 24 F Administrative llOURS.
O-Operathmal Error (Explain) 1 11.Other(Explain)
m Joseph M. Farley Nuclear Plant Unit 2 Narrative Summary of Operations l April 1997 i
There were no unit shutdowns or power reductions during the month.
There was no major safety related maintenance performed during the month.
l -.
l l
l l
l l
l l
l L
l I
t
. _ _ _ . . _ _ _ . _ _ _ _ _ _ . _ . _ _ _ . _ m .-___._.__ _ . _ _ _ __ _ _ _ _______ . _____.______._.m____ .
OPERATING DATA REPORT DOCKET NO. 50-364 DATE May 5,1997 COMPLETED BY M. W. McAnulty TELEPHONE (334) 899-5156, ext.3640 OPERATING STATUS
- 1. Unit Name: Joseph M. Farley - Unit 2 Notes
- 2. Reporting Period: April 1997 1) Cumulative data since 07-30-81,
- 3. Licensed Thermal Power (MWt): 2,652 date ofcommercial operation.
- 4. Nameplate Rating (Gross MWe): 860
- 5. Design Electrical Rating (Net MWe): 829
- 6. Maximum Dependable Capacity (Gross MWe): 863.6
- 7. Maximum Dependable Capacity (Net MWe): 822
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Smce Last Report, Give Reasons: N/A
- 9. Power Level To Which Restricted, If Any (Net MWe): N/A
- 10. Reasons For Restrictions,If Any: N/A This Month Yr. to Date Cumulative
- 11. IIours in Reporting Period 719.0 2,879.0 138,096.0
- 12. Number OfIIours Reactor Was Critical 719.0 2,879.0 118,996.0
- 13. Reactor Reserve Shutdown llours 0.0 0.0 138.0
- 14. liours Generator On line 719.0 2,879.0 117,249.9
- 15. Unit Reserve Shutdown llours 0.0 0.0 0.0
- 16. Gross Thermal Energy Generated (MWil) 1,906,788.0 7,54 ,306.8 298,989,401.0
- 17. Gross Electrical Energy Generated (MWII) 633,017.0 2,505,229.0 98,019,527.0
- 18. Net Electrical Energy Generated (MWII) 603,739.0 2,388,093.0 92,938,549.0 l
- 19. Unit Service Factor 100.0 100.0 84.9
- 20. Unit Availability Factor 100.0 100.0 84.9_
- 21. Unit Capacity Factor (Using MDC Net) 102.2 100.9 82.0
- 22. Unit Capacity Factor (Using DER Net) 101.3__ 100.1 81.2
- 23. Unit Forced Outage Rate 0.0 0.0 3.7
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
- 25. If Shut Down at End Of Report Period, Estimated Date of Startup: N/A ~
- 26. Units In Test Status (Prior To Commercial Operation): Forceast Achieved Initial Criticality 05/06/81 05/08/81 Initial Electricity 05/24/81 05/25/81 Cornmercial Operation 08/01/81 07/30/81 r
^~ .
- DOCKET NO. 50-364 j l-
. UNIT 2 ;
DATE May 5,1997 ;
COMPLETED BY M. W. McAnuity l l' TELEPHONE (334) 899-5156 ext 3640 i
MONTil April ,
, DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) ,
1 846 17 842 l
2 844 18 845 3 843 19 842 4 838 20 846 ;
5 835 21 833 6 834 22 832 l 7 837 23 838 8 844 24 842 9 843 25 842 10 843 26 840 ,
11 837 27 832 !
835 l 12 836 28 l3 842 29 839 !
i 14' 845 30 839 15 844 31 N/A J 16 843 l
INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting period. Compute to the nearest whole megawatt.
l . ~-
r -
a.. - UNIT SHUTDOWNS AND POWER REDUCTIONS i
DOCKET NO. 50-364 !
UNIT NAME J. M. Farley - Unit 2 DATE May 5,1997 COMPLETED BY M. W. McAnuity [
REPORT MONTil April TELEPHONE (334) 899-5156, ext.3640 R M !
E E S ,
T A T Y Y S 11 SC j P O O TO CAUSE AND CORRECTIVE
{
E DURATION N D ED COMPONENT ACTION TO
~
NO. DATE (1) (llOURS) (2) (3) LEA # ME CODE (5) PREVENT RECURRENCE l @,_ere were no ShutdO,wns Or power reductions during the month. l l
i t
t l !
i l
! I,
,-. - .m., .
a 1: 2: 3: EVENTS REPORTED p F; forced Reason Method INVOLVE A S: Scheduled A Equipment Failurc(Exclain) 1 Manual GREATER TilAN 20%
B Maintenance or Test 2 - Manual Scram REDUCTION IN C Refueling 3 Automatic Scram AVERAGE DAILY D Regulatory Restriction 4 Other(Explain) POWER LEVEL FOR E Operator Training & License Examination Tite PRECEDINO 24 F Administrative llOURS.
G OperationalError(Explain)
I 11 Other(Esplain)
I i
i
. . _ _