ML18087A876

From kanterella
Revision as of 07:45, 3 February 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Forwards 830414 & 26 Ltrs Documenting Review of Corrective Action Program Re 830222 & 25 Reactor Trip Breaker Failures. Ltrs Previously Transmitted at 830414 & 26 Meetings
ML18087A876
Person / Time
Site: Salem PSEG icon.png
Issue date: 04/27/1983
From: Uderitz R
Public Service Enterprise Group
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML18087A877 List:
References
NUDOCS 8305020150
Download: ML18087A876 (2)


Text


*-*---

Richard A. Uderitz Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609 935-6010 Vice President -

Nuclear April 27, 1983 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention: Mr. Darrell G. Eisenhut, Director qivision of Licensing Gentlemen:

BETA CORPORATION REPORTS REACTOR TRIP BREAKER FAILURES SALEM GENERATING STATION UNITS NO. 1 AND 2 DOCKET NOS. 50-272 AND 50-311 PSE&G hereby transmits copies of the April 14 and 26, 1983 letters from BETA Corporation, . which document the.ir review of PSE&G's Corrective Action Program related to the February 22 and 25, 1983 reactor trip breaker failures. These letters have been previous-ly'.t'ransmitted at meetings with the NRC staff on April 14 and *26; ,.l983. . .. "" _.

Sincerely, CC: Mr. Richard w. Starostecki, Director Division of Project and Resident Programs Region I Mr. Leif Norrholm NRC Senior Resident Inspector 8305020150 830427 PDR ADOCll\ 05000272 S PDR

BASIC 9 ROSSLYN CENTER. SUITE 825 1700 N. MOORE STREET ARLINGTON. VIRGINIA 22209 ENERGY I 703) 243-4600 TECHNOLOGY ASSOCIATES, INC. April 14, 1983 Mr. Richard M. Eckert, Chairman Public Service Electric & Gas Company 80 Park Place Newark, New Jersey 07101

Dear Mr. Eckert:

In accordance with your request of April 5, 1983, BETA began an independent review of the adequacy of the actions being taken by PSE&G as a result of the recent reactor breaker trip incidents at the Salem Generating Station.

We* have completed the preliminary phase of this review and, as you directed, we are attaching herewith our report covering the work performed to date.

  • We intend to continue our review of the adequacy of the long term actions and will provide you a report upon completion of that effort.

Sincerely, (J.!J_r-.

W. Wegn Associa Attachment