ML19207B105

From kanterella
Revision as of 09:12, 24 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LER 79-047/03L-0
Date released: 08/09/2019 Download: ML19207B105


LER 79-047/03L-0 on 790719:during Normal Reactor Startup, full-in Indication Remained on After Rod 10-23 Was Pulled. No Indication of full-in on Rod 42-11 Given & full-in Signal Not Sent to Control Circuitry by Rod 22-11.Repaired
ML19207B106
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 08/15/1979
From: Tollison A
CAROLINA POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19207B106 (1)
Forwards LER 79-047/03L-0
ML19207B104
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 08/15/1979
From: Banks H
CAROLINA POWER & LIGHT CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19207B104 (1)