IR 05000351/2014001

From kanterella
Revision as of 00:03, 12 July 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Knik Construction; Amendment 04, License 50-35114-01; Docket 030-38694; Control 611501
ML19078A160
Person / Time
Site: 03038694, 05000351
Issue date: 03/12/2019
From: Ricardo Torres
NRC Region 4
To:
Knik Construction
References
611501
Download: ML19078A160 (5)


Text

U.S. NUCLEAR REGULATORY COMMISSIONMATERIALS LICENSE NRC FORM 374PAGE OF15 Amendment No. 4 P AGESPursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter I, Parts 30, 31, 32, 33, 34, 35, 36, 37, 39, 40, 70 and 71, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, source, and special nuclear material designated below; to use such material for the purpose(s)

and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified belo Licensee Anchorage, AK 99502 2.6400 South Airpark Drive 1.Knik Construction 4.Expiration Date:

December 31, 2023 Docket No.:

5.030-38694License number: 50-35114-01 is amended in its entirety to read as follows: Reference No.:

3.In accordance with letter dated February 18, 2019 6.7.8.Byproduct, source, and/or special nuclear material Chemical and/or physical form Maximum amount that licensee

may possess at any one time

under this license 9.Authorized use A.A.A.A.For use in Troxler Electronic Laboratories Model 3400 Series portable gauging devices for measuring

physical properties of materials.Sealed Sources (AEA Technology/QSA, Inc., Model

CDCW556; Isotope Product

Laboratories, Model HEG-137)

9 millicuries per source

and 45 millicuries total Cesium-137 B.B.B.B.For use in Troxler Electronic

Laboratories Model 3400 Series

portable gauging devices for measuring

physical properties of materials.Sealed Neutron Source (AEA Technology/QSA, Inc., Model

AMNV.997; Isotope Product Laboratories, Model AM1.NO2, 3021, or 3027)

44 millicuries per source

and 220 millicuries total Americium-241/

Beryllium C.C.C.C.For use in Troxler Electronic

Laboratories Model 3400 Series

portable gauging devices for measuring

physical properties of materials.Sealed Neutron Source (AEA Technologies, Model CVN.1, Capsule Type X.1; Isotope

Product Laboratories, Model

HEG-252)66 microcuries per source

and 66 microcuries total Californium-252 License Number Docket or Reference Number U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEETPAGES OFPAGE 5 2 50-35114-01 030-38694 Amendment No. 4 6.7.8.Byproduct, source, and/or special nuclear material Chemical and/or physical form Maximum amount that licensee may possess at any one time under this license 9.Authorized use D.D.D.D.For use in Troxler Electronic Laboratories Model 3241-C portable gauging devices for measuring physical properties of materials.

Sealed Neutron Source (Amersham Corporation, Model AMNV.340 or AMNV.339)110 millicuries per source and 550 millicuries total Americium-241/

Beryllium E.E.E.E.For use in Seaman Nuclear Corporation Model C-200 Series portable gauging devices for measuring physical properties of materials.

Sealed Neutron Source (Nuclear Sources and Services, Model AN-HPG, or GT-GHP)

5.5 millicuries per source and 5.5 millicuries total Radium-226/ Beryllium F.F.F.F.For use in Seaman Nuclear Corporation Model C-300 Series portable gauging devices for measuring physical properties of materials.

Sealed Neutron Source (AEA Technology , Model RAN.C1; Gammatron, Model GT-GHP; Radium Chemical Corporation, Model Drawing 21.94)

5.5 millicuries per source and 5.5 millicuries total Radium-226/ Beryllium G.G.G.G.For use in Humboldt Scientific, Inc., Model 5001EZ portable gauging devices for measuring physical properties of materials.

Sealed Sources (AEA Technology

/QSA, Inc., Model CDC.805; Isotope Product Laboratories, Model HEG-137)11 millicuries per source and 22 millicuries total Cesium-137 H.H.H.H.For use in Humboldt Scientific, Inc., Model 5001EZ portable gauging devices for measuring physical properties of materials.

Sealed Neutron Source (AEA Technology

/QSA, Inc., Model AMN.V997; Isotope Product Laboratories, Model Am 1.NO2)44 millicuries per source and 88 millicuries total Americium-241/

Beryllium CONDITIONS 10.Licensed material may be used or stored at the licensee's facilities located at:

A. 1171 Old First Avenue , Bethel, Alaska, 99559 B. 44482 Frontier Avenue , Soldotna, Alaska, 99669 C. 6400 South Airpark Drive , Anchorage, Alaska, 99502 License Number Docket or Reference NumberU.S. NUCLEAR REGULATORY COMMISSION NRC FORM 374AMATERIALS LICENSESUPPLEMENTARY SHEETPAGES OFPAGE53 50-35114-01 030-38694 Amendment No. 4 D.Temporary job sites anywhere in the United States where the U.S. Nuclear Regulatory Commission maintains jurisdiction for regulatingthe use of licensed material, including areas of exclusive Federal jurisdiction within Agreement States.If the jurisdiction status of a Federal facility within an Agreement State is unknown, the licensee should contact the Federal agency controlling the job site in question to determine whether the proposed job site is an area of exclusive Federal jurisdictio Authorizationfor use of radioactive materials at job sites in Agreement States not under exclusive Federal jurisdiction shall be obtained from the appropriate state regulatory agency.11.Licensed material shall only be used by, or under the supervision and in the physical presence of, individuals who have received the training

described in the e-mail with attachments received November 13, 2013. The licensee shall maintain records of individuals designated as users for 3 years following the last use of licensed material by the individual.

12.The Radiation Safety Officer (RSO) for this license is Scott C. Judah.

13.A.Sealed sources shall be tested for leakage and/or contamination at intervals not to exceed the intervals specified in the certificate of registration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement Stat In the absence of a registration certificate, sealed sources shall be tested for leakage and/or contamination at intervals not to exceed 6 months, or at such other intervals as specified.

B.In the absence of a certificate from a transferor indicating that a leak test has been made within the intervals specified in the certificate ofregistration issued by the U.S. Nuclear Regulatory Commission under 10 CFR 32.210 or by an Agreement State, prior to the transfer, a sealed source received from another person shall not be put into use until tested and the test results received.

C.Sealed sources need not be tested if they are in storage and are not being used. However, when they are removed from storage for use

or transferred to another person, and have not been tested within the required leak test interval, they shall be tested before use or transfer. No sealed source shall be stored for a period of more than 10 years without being tested for leakage and/or contaminatio License Number Docket or Reference Number U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 374A MATERIALS LICENSE SUPPLEMENTARY SHEETPAGES OFPAGE 5 4 50-35114-01 030-38694 Amendment No. 4 D.The leak test shall be capable of detecting the presence of 185 becquerels (0.005 microcuries) of radioactive material on the test sample. If the test reveals the presence of 185 becquerels (0.005 microcuries) or more of removable contamination, a report shall be filed with the U.S. Nuclear Regulatory Commission in accordance with 10 CFR 30.50(c)(2), and the source shall be removed immediately from service and decontaminated, repaired, or disposed of in accordance with Commission regulations.

E.Analysis of leak test samples and/or contamination shall be performed by persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services. The licensee is authorized to collect leak test samples but not perform the analysis.

F.Records of leak test results shall be kept in units of becquerels (microcuries) and shall be maintained for 3 years.

14.Sealed sources or source rods containing licensed material shall not be opened or sources removed from source holders or detached from source rods by the licensee, except as specifically authorized.

15.The licensee shall conduct a physical inventory every 6 months, or at other intervals approved by the U.S. Nuclear Regulatory Commission, to account for all sealed sources and/or devices received and possessed under the license. Records of inventories shall be maintained for 3 years from the date of each inventory, and shall include the radionuclides, quantities, manufacturer's name and model numbers, and the date of the inventory.

16.Except for maintaining labeling as required by 10 CFR Part 20, or Part 71, the licensee shall obtain authorization from the U.S. Nuclear Regulatory Commission before making any changes in the sealed source, device, or source-device combination that would alter the description or specifications as indicated in the respective certificate of registration issued either by the U.S. Nuclear Regulatory Commission pursuant to 10 CFR 32.210 or by an Agreement State

.17.Each portable nuclear gauge shall have a lock or outer locked container designed to prevent unauthorized or accidental removal of the sealed source from its shielded position. The gauge or its container must be locked when in transport or storage, or when not under the direct surveillance of an authorized use License Number Docket or Reference NumberU.S. NUCLEAR REGULATORY COMMISSION NRC FORM 374AMATERIALS LICENSESUPPLEMENTARY SHEETPAGES OFPAGE55 50-351 14-01 030-38694 Amendment No. 4 18.Any cleaning, maintenance, or repair of the gauge(s) that requires detaching the source or source rod from the gauge shall be performedonly by the manufacturer or by other persons specifically licensed by the U.S. Nuclear Regulatory Commission or an Agreement State to perform such services.

19.Except as specifically provided otherwise in this license, the licensee shall conduct its program in accordance with the statements, representations, and procedures contained in the documents, including any enclosures, listed belo This license condition applies only to

those procedures that are required to be submitted in accordance with the regulation The U.S. Nuclear Regulatory Commission's

regulations shall govern unless the statements, representations, and procedures in the licensee's application and correspondence are more

restrictive than the regulations.A.Application dated July 31, 2013 (ML13281A912)B.E-mail with attachments received November 13, 2013 (ML13324A263)

C.Letter dated November 17, 2013 (ML13352A080)

D.Letter dated January 16, 2018 (ML18031B164)

E.E-mail dated March 26, 2018 with attachment (ML18086A500)

F.Delegation of authority memorandum dated February 18, 2019 (ML19066A144)FOR THE U.S. NUCLEAR REGULATORY COMMISSION By: Date:Roberto J. TorresRegion March 12, 2019