ML18184A118

From kanterella
Revision as of 01:00, 17 June 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Jan X-Ray Services D/B/A Janx - NRC Form 591 Part 1 & 3, Inspection Report 03011772/2018001 (DNMS)
ML18184A118
Person / Time
Site: 03011772
Issue date: 06/19/2018
From: Ryan Craffey
NRC/RGN-III
To: Reeve W
JAN X-ray Services, JANX
References
IR 2018001
Download: ML18184A118 (2)


See also: IR 07200201/1980001

Text

NRC FORM 591M PART 1 U.S. NUCLEAR REGULATORY

COMMISSION

(07-2012)

10CFR 2 , 201 SAFETY INSPECTION

REPORT AND COMPLIANCE

INSPECTION

1. LICENSEE/LOCATION

INSPECTED:

JAN X-Ray Services d/b/a JANX 8550 East Michigan A venue, Parma, MI 49269 Location Inspected:

Job Site in Grayling, MI REPORT NUMBER(S)

2018001 2. NRG/REGIONAL

OFFICE Region III U.S. Nuclear Regulatory

Commission

2443 Warrenville

Road, Suite 210 Lisle, IL 60532-4352

3. DOCKET NUMBER(S)

4. LICENSE NUMBER(S)

5. DATE(S) OF INSPECTION

030-11772

21-16560-01

June 19, 2018 LICENSEE:

The inspection

was an examination

of the activities

conducted

under your license as they relate to radiation

safety and to compliance

with the Nuclear Regulatory

Commission (NRC) rules and regulations

and the conditions

of your license. The inspection

consisted

of selective

examinations

of procedures

and representative

records, interviews

with personnel, and observations

by the inspector.

The inspection

findings are as follows: [Z] 1. D 2. D 3. D 4. Based on the inspection

findings, no violations

were identified.

Previous violation(s)

closed. The violations(s), specifically

described

to you by the inspector

as non-cited

violations, are not being cited because they were self-identified, non-repetitive, and corrective

action was or is being taken, and the remaining

criteria in the NRC Enforcement

Policy, to exercise discretion, were satisfied.

Non-cited

violation(s)

were discussed

involving

the following

requirement(s):

During this inspection, certain of your activities, as described

below and/or attached, were in violation

of NRC requirements

and are being cited in accordance

with NRC Enforcement

Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance

with 10CFR 19.11. (Violations

and Corrective

Actions) Statement

of Corrective

Actions I hereby state that, within 30 days, the actions described

by me to the Inspector

will be taken to correct the violations

identified.

This statement

of corrective

actions is made in accordance

with the requirements

of 10 CFR 2.201 (corrective

steps already taken, corrective

steps which will be taken, date when full compliance

will be achieved).

I understand

that no further written response to NRC will be required, unless specifically

requested.

TITLE PRINTED NAME SIGNATURE

DATE LICENSEE'S

REPRESENTATIVE

NRC INSPECTOR

Ryan Craffey BRANCH CHIEF Aaron Mccraw NRG FORM 591M PART 1 (07-2012)

06/26/2018

06/29/2018

U.S. NUCLEAR REGULATORY

COMMISSION

NRC FORM 591M PART 3 (07-2012)

10 CFR 2.201 Docket File Information

SAFETY INSPECTION

REPORT AND COMPLIANCE

INSPECTION

1. LICENSEE/LOCATION

INSPECTED:

JAN X-Ray Services d/b/a JANX 8550 East Michigan A venue, Parma, MI 49269 Location Inspected:

Job Site in Grayling, MI REPORT NUMBER(S)

2018001 3. DOCKET NUMBER(S)

030-11772

6. INSPECTION

PROCEDURES

USED 87121 2. NRG/REGIONAL

OFFICE 4. LICENSE NUMBER(S)

21-16560-01

Region III U. S. Nuclear Regulatory

Commission

2443 Warrenville

Road, Suite 210 Lisle, IL 60532-4352

5. DATE(S) OF INSPECTION

June 19, 2018 7. INSPECTION

FOCUS AREAS FE 1-6 SUPPLEMENTAL

INSPECTION

INFORMATION

1. PROGRAM CODE(S) 03320 2. PRIORITY D Main Office Inspection

D Field Office Inspection

3. LICENSEE CONTACT William Reeve -RSO Next Inspection

Date: 4. TELEPHONE

NUMBER (517) 531-8210 No Change [{] Temporary

Job Site Inspection

Arauco Plant, West Four Mile Road, Grayling, MI PROGRAM SCOPE This was an unannounced

field inspection

of a large non-destructive

testing company authorized

to use radioactive

material for industrial

radiography

at numerous field stations and at temporary

jobsites throughout

NRC jurisdiction.

The scope of this inspection

was limited to observations

of radiographic

testing on the premises of a particleboard

manufacturing

plant, currently

under construction

in Grayling, Michigan.

PERFORMANCE

OBSERVATIONS

The inspector

observed the conduct of radiographic

operations

by the licensee's

crew at the plant construction

site in Grayling.

The crew routinely

worked overnight

at the site to minimize the potential

for exposure to members of the public, as the project was heavily staffed during the day. The inspector

noted the satisfactory

set-up and control of various restricted

area boundaries

during these operations, as supported

by independent

and confirmatory

surveys. The inspector

also noted adequate compliance

with physical presence requirements

for radiographic

operations.

Through interviews, the inspector

found that the radiographer

and his assistant

were knowledgeable

of radiation

protection

principles, licensee procedures and regulatory

requirements, and that their

dosimetry

and survey instruments

were calibrated, operable, and properly utilized.

The radiographic

exposure device they utilized, a SPEC Model 150, was likewise in good condition

and properly labeled. While on the jobsite, the inspector

reviewed the crew's shipping papers, utilization

logs, and leak test documentation.

No violations

ofNRC requirements

were identified

as a result of this inspection.

NRG FORM 591M PART 3 (07-2012)