ML18057A480

From kanterella
Revision as of 20:30, 13 September 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
ABWR DC Renewal SE Section 13.3 - Emergency Planning
ML18057A480
Person / Time
Site: 05200045
Issue date: 06/21/2018
From: Adrian Muniz
NRC/NRO/DNRL
To:
Muniz A
Shared Package
ML18057A450 List:
References
Download: ML18057A480 (9)


Text

Technical Support Center (TSC) Habitability

Generic Inspections, Tests, Analyses, and Acceptance Criteria (EP ITAAC)*The TSC has comparable habitability to the control room habitability under accident conditions.

  • An inspection of the as-built TSC habitability system will be performed, including a test of its capabilities*The TSC radiological habitability is comparable to the control room habitability under accident conditions such that doses to an individual do not exceed 5 rem whole body radiation exposure or 30 rem thyroid over the 30-day post-accident period.

the italicized text identifies the change to COL Information Item 9.16 in the certified DCD

The COL applicant will perform TSC radiological consequence analyses, considering plant and site conditions to ensure that TSC radiological habitability design features ensure that doses to an individual do not exceed 5 rem whole body or 30 rem thyroid over the 30-day post-accident period.Fukushima Dai-ichi nuclear power plant accident - NTTF Recommendation 9.3