  1. ML20062H817 →‎ 05000219/LER-1982-039 →‎ 05000219/LER-1982-039, Forwards Updated LER 82-039/03X-1.Detailed Event Analysis Encl
  2. ML20063N231 →‎ 05000219/LER-1982-039, Updated LER 82-039/03X-1:on 820701,during Surveillance Testing,Thermocouple for Safety Valve NR28J Found Inoperable.Caused by Terminal Screw Backing Out,Causing Intermittent Contact & Erratic Readings.Screw Replaced →‎ 05000219/LER-1982-039, Forwards Updated LER 82-039/03X-1.Detailed Event Analysis Encl
  3. ML20066K698 →‎ 05000219/LER-1982-052 →‎ 05000219/LER-1982-052, Forwards LER 82-052/01T-0.Detailed Event Analysis Encl
  4. 05000219/LER-1982-052, Forwards LER 82-052/01P →‎ 05000219/LER-1982-052 →‎ 05000219/LER-1982-052, Forwards LER 82-052/01T-0.Detailed Event Analysis Encl
  5. ML20069Q246 →‎ 05000219/LER-1982-053 →‎ 05000219/LER-1982-053, Forwards LER 82-053/03L-1.Detailed Event Analysis Encl
  6. 05000219/LER-1982-053, Forwards LER 82-053/03L-0.Detailed Event Analysis Encl →‎ 05000219/LER-1982-053 →‎ 05000219/LER-1982-053, Forwards LER 82-053/03L-1.Detailed Event Analysis Encl
  7. ML20064E785 →‎ 05000219/LER-1982-055 →‎ 05000219/LER-1982-055, Forwards LER 82-055/01P-0
  8. 05000219/LER-1982-055, Forwards LER 82-055/01T-0.Detailed Event Analysis Encl →‎ 05000219/LER-1982-055 →‎ 05000219/LER-1982-055, Forwards LER 82-055/01P-0
  9. ML20072Q925 →‎ 05000219/LER-1983-012 →‎ 05000219/LER-1983-012, Forwards LER 83-012/01T-0.Detailed Event Analysis Encl
  10. 05000219/LER-1983-012, Preliminary LER 83-012/01P:on 830319,during Performance of Secondary Containment Checkoff Prior to Refueling Operations,Door to Main Steam Line Tunnel Room Discovered Open.Caused by Procedural Failure.Door Secured →‎ 05000219/LER-1983-012 →‎ 05000219/LER-1983-012, Forwards LER 83-012/01T-0.Detailed Event Analysis Encl
  11. ML20073G439 →‎ 05000219/LER-1983-014 →‎ 05000219/LER-1983-014, Forwards LER 83-014/01T-0.Detailed Event Analysis Encl
  12. ML20206H627 →‎ 05000219/LER-1998-011 →‎ 05000219/LER-1998-011, Forwards LER 98-011-02, Three Small Bore Pipe Lines Did Not Meet Design Bases for Siesmic & Thermal Allowables. Engineering Std Will Not Be Completed Until End of 4th Quarter of 1999 Due to Scheduling Conflicts
  13. 05000219/LER-1998-011, Forwards LER 98-011-01,re Three Small Bore Lines That Did Not Meet Design Bases for Seismic & Thermal Allowables. Rev Provides Results of Insps & Calculations That Had Not Been Completed in Rev 0 →‎ 05000219/LER-1998-011 →‎ 05000219/LER-1998-011, Forwards LER 98-011-02, Three Small Bore Pipe Lines Did Not Meet Design Bases for Siesmic & Thermal Allowables. Engineering Std Will Not Be Completed Until End of 4th Quarter of 1999 Due to Scheduling Conflicts
  14. ML20062N682 →‎ 05000220/LER-1982-009, Updated LER 82-009/01X-1:on 820323,water Observed Leaking from Insulation on Recirculation Piping Discharges 11 & 15 from Reactor Vessel.Caused by Cracking in Riser Elbow Welds. Recirculation Piping Replaced →‎ 05000220/LER-1982-009, Forwards Updated LER 82-009/01X-1
  15. ML20134B611 →‎ 05000220/LER-1985-008 →‎ 05000220/LER-1985-008, Corrected LER 85-008-00:on 850610,review by Operations Dept Discovered That Temporary Jumper/Block Log 2036 Not Reviewed by General Superintendent within 14-day Time Limit,Per Tech Spec 6.8.3.C
  16. ML20090E388 →‎ 05000237/LER-1950-237 →‎ 05000237/LER-1950-237, Updated LER 50-237/75-048:on 751007,through-wall Crack Found in Drywell/Torus Nitrogen Purge Line 1604-18.Addl Mods, Including Temp Controlled Isolation Valve Installation, Delayed Until Proposal Review
  17. ML20090E362 →‎ 05000237/LER-1950-237 →‎ 05000237/LER-1950-237, Updated LER 50-237/75-048:on 751007,through-wall Crack Found in Drywell/Torus Nitrogen Purge Line 1604-18.Addl Mods, Including Temp Controlled Isolation Valve Installation, Delayed Until Proposal Review
  18. ML20090E356 →‎ 05000237/LER-1950-237 →‎ 05000237/LER-1950-237, Updated LER 50-237/75-048:on 751007,through-wall Crack Found in Drywell/Torus Nitrogen Purge Line 1604-18.Addl Mods, Including Temp Controlled Isolation Valve Installation, Delayed Until Proposal Review
  19. ML20090E349 →‎ 05000237/LER-1950-237 →‎ 05000237/LER-1950-237, Updated LER 50-237/75-048:on 751007,through-wall Crack Found in Drywell/Torus Nitrogen Purge Line 1604-18.Addl Mods, Including Temp Controlled Isolation Valve Installation, Delayed Until Proposal Review
  20. ML20090E337 →‎ 05000237/LER-1950-237 →‎ 05000237/LER-1950-237, Updated LER 50-237/75-048:on 751007,through-wall Crack Found in Drywell/Torus Nitrogen Purge Line 1604-18.Addl Mods, Including Temp Controlled Isolation Valve Installation, Delayed Until Proposal Review
  21. ML20063L727 →‎ 05000237/LER-1981-020, Updated LER 81-020/01X-1:on 810426,during ASME Hydrostatic Test,Water Observed Seeping from Cracks in 2.5-inch Rx Head Spray Line.Caused by Chloride Induced Stress Corrosion Cracking.Cracks Cut Out & Piping Replaced →‎ 05000237/LER-1981-020, Forwards Updated LER 81-020/01X-1
  22. ML20062G519 →‎ 05000237/LER-1981-055, Updated LER 81-055/03X-1:on 810830,small Leak Detected in Floor Drain Discharge Line.Caused by Butt Weld Failure on Line 2/3-2014 6-inch Carbon Steel Pipe,Weakened by Corrosive Solutions.Affected Pipe Section Replaced →‎ 05000237/LER-1981-055, Forwards Updated LER 81-055/03X-1
  23. ML20054D087 →‎ 05000237/LER-1982-008 →‎ 05000237/LER-1982-008, Forwards LER 82-008/03L-0
  24. ML20054D174 →‎ 05000237/LER-1982-009 →‎ 05000237/LER-1982-009, Forwards LER 82-009/03L-0
  25. ML20054G470 →‎ 05000237/LER-1982-013 →‎ 05000237/LER-1982-013, Forwards LER 82-013/03X-1
  26. ML20053E296 →‎ 05000237/LER-1982-014 →‎ 05000237/LER-1982-014, Forwards Updated LER 82-014/03X-1
  27. ML20053E287 →‎ 05000237/LER-1982-014, Forwards LER 82-014/03L-0 & NPDES Deviation Notification →‎ 05000237/LER-1982-014, Updated LER 82-014/03X-1:on 820502,radwaste Sump Pumps Started & Floor Drain Collector Tank Level Rose.Caused by Small corrosion-related Crack in Line 2/3-2034D,2.5-inch Diameter Pipe.Line Taken Out of Svc for Repairs
  28. 05000237/LER-1982-014, Forwards LER 82-014/03L-0 & NPDES Deviation Notification →‎ 05000237/LER-1982-014, Updated LER 82-014/03X-1:on 820502,radwaste Sump Pumps Started & Floor Drain Collector Tank Level Rose.Caused by Small corrosion-related Crack in Line 2/3-2034D,2.5-inch Diameter Pipe.Line Taken Out of Svc for Repairs →‎ 05000237/LER-1982-014, Forwards Updated LER 82-014/03X-1
  29. ML20062G533 →‎ 05000237/LER-1982-014, Updated LER 82-014/03X-1:on 820502,radwaste Sump Pumps Started & Floor Drain Collector Tank Level Rose.Caused by Small corrosion-related Crack in Line 2/3-2034D,2.5-inch Diameter Pipe.Line Taken Out of Svc for Repairs →‎ 05000237/LER-1982-014, Forwards Updated LER 82-014/03X-1
  30. ML20053E243 →‎ 05000237/LER-1982-015 →‎ 05000237/LER-1982-015, Forwards LER 82-015/03L-0
  31. ML20054K532 →‎ 05000237/LER-1982-018 →‎ 05000237/LER-1982-018, Forwards LER 82-018/03L-0
  32. ML20063E181 →‎ 05000237/LER-1982-019 →‎ 05000237/LER-1982-019, Forwards Updated LER 82-019/03X-1
  33. 05000237/LER-1982-019, Forwards LER 82-019/03L-0.Detailed Event Analysis Encl →‎ 05000237/LER-1982-019 →‎ 05000237/LER-1982-019, Forwards Updated LER 82-019/03X-1
  34. ML20066A716 →‎ 05000237/LER-1982-019, Updated LER 82-019/03X-1:on 820605,thermocouple on Electromatic Relief Valve 2-203-3D Failed Open.Caused by Broken Ceramic Insulator in Thermocouple Head & Twisted Wires Due to Improper Installation.Thermocouple Replaced →‎ 05000237/LER-1982-019, Forwards Updated LER 82-019/03X-1
  35. ML20058E718 →‎ 05000237/LER-1982-023 →‎ 05000237/LER-1982-023, Revised Deviation Rept for LER 82-023/03L-0:on 820623, Wrong Assumption Made for Drywell to Torus Differential Pressure.Caused by High Torus Pressure Transmitter 2-1673 Measurement
  36. ML20058C637 →‎ 05000237/LER-1982-027 →‎ 05000237/LER-1982-027, Forwards Updated LER 82-027/01X-1
  37. ML20065T487 →‎ 05000237/LER-1982-027, Updated LER 82-027/01X-1:on 820708,during Normal Operations, HPCI Motor Gear Unit Observed Moving Between High & Low Speed Stops W/O Operator Action.Caused by Improper Ground in Power Supply.New Ground Wire Installed →‎ 05000237/LER-1982-027, Forwards Updated LER 82-027/01X-1
  38. ML20063F555 →‎ 05000237/LER-1982-034 →‎ 05000237/LER-1982-034, Forwards Updated LER 82-034/03X-1
  39. ML20064N249 →‎ 05000237/LER-1982-034, Updated LER 82-034/03X-1:on 820726,during Power Operation, Pinhole Leak Discovered in HPCI Drain Pot Drainline to Main Condenser.Caused by Erosion.Segment of Pipe Replaced W/Schedule 80 Carbon Steel Pipe →‎ 05000237/LER-1982-034, Forwards Updated LER 82-034/03X-1
  40. ML20062N565 →‎ 05000237/LER-1982-036 →‎ 05000237/LER-1982-036, Forwards Updated LER 82-036/03X-1
  41. 05000237/LER-1982-036, Forwards LER 82-036/03L-0 →‎ 05000237/LER-1982-036 →‎ 05000237/LER-1982-036, Forwards Updated LER 82-036/03X-1
  42. ML20062N137 →‎ 05000237/LER-1982-037 →‎ 05000237/LER-1982-037, Forwards Updated LER 82-037/03X-1
  43. 05000237/LER-1982-037, Forwards LER 82-037/03L-0 →‎ 05000237/LER-1982-037 →‎ 05000237/LER-1982-037, Forwards Updated LER 82-037/03X-1
  44. ML20065G635 →‎ 05000237/LER-1982-040 →‎ 05000237/LER-1982-040, Forwards Updated LER 82-040/03X-1
  45. 05000237/LER-1982-040, Forwards LER 82-040/03L-0 →‎ 05000237/LER-1982-040 →‎ 05000237/LER-1982-040, Forwards Updated LER 82-040/03X-1
  46. ML20069J841 →‎ 05000237/LER-1982-042 →‎ 05000237/LER-1982-042, Forwards Updated LER 82-042/01X-1
  47. 05000237/LER-1982-042, Forwards LER 82-042/01T-0 →‎ 05000237/LER-1982-042 →‎ 05000237/LER-1982-042, Forwards Updated LER 82-042/01X-1
  48. 05000237/LER-1982-042, Updated LER 82-042/01X-1:on 821002,during Normal Operation, Following Torus Hi/Lo Level Alarm,Sightglass Isolation & Vent Valves Reported Open W/No Indication of Excess Makeup. Caused by Operator Error.Valves Locked Closed →‎ 05000237/LER-1982-042, Forwards LER 82-042/01T-0 →‎ 05000237/LER-1982-042
  49. ML20069N142 →‎ 05000237/LER-1982-042, Updated LER 82-042/01X-1:on 821002,during Normal Operation, Following Torus Hi/Lo Level Alarm,Sightglass Isolation & Vent Valves Reported Open W/No Indication of Excess Makeup. Caused by Operator Error.Valves Locked Closed →‎ 05000237/LER-1982-042, Forwards LER 82-042/01T-0
  50. ML20071C786 →‎ 05000237/LER-1983-002, Updated LER 83-002/03X-1:on 830103,valve Mo 2-1501-19A Failed to Close During Test.Caused by Loose Wire 19A-CR109CO in Combination Starter.Terminal Tightened & Valve Successfully Cycled from Control Room →‎ 05000237/LER-1983-002, Forwards Updated LER 83-002/03X-1