TXX-4912, Interim Deficiency Rept CP-84-12 Re Environ Qualification of Equipment Outside Containment for High Energy Line Breaks. Initially Reported on 840604.Evaluation Continuing.Next Rept Will Be Submitted by 860919

From kanterella
Revision as of 00:44, 10 July 2023 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Interim Deficiency Rept CP-84-12 Re Environ Qualification of Equipment Outside Containment for High Energy Line Breaks. Initially Reported on 840604.Evaluation Continuing.Next Rept Will Be Submitted by 860919
ML20207K903
Person / Time
Site: Comanche Peak  
Issue date: 07/16/1986
From: Counsil W, Keeley G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
CP-84-12, TXX-4912, NUDOCS 8607300110
Download: ML20207K903 (1)


Text

- Log # TXX-4912 File # 10110 903.11 TEXAS UTIL,iTIES GENERATING COMPANY

......,_..._._..,_._...........m........_,

July 16, 1986 E W IV W CE PASS DEse?

Mr. Eric H. Johnson, Director f}$

Division of Reactor Safety and Projects ' Jj['~@llyG(\//"- K' '

U. S. Nuclear Regulatory commission 611 Ryan Plaza Drive, Suite 1000 dUl2l1986 Arlington, TX 76012 f ,

L

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 IMPACT OF HELB TEMPERATURES ON QUALIFIED EQUIPMENT OUTSIDE CONTAINMENT SDAR: CP-84-12 (INTERIM REPORT)

Dear Mr. Johnson:

On June 4,1984, we verbally notified your Mr. D. Hunnicutt of a deficiency 1

involving the environmental qualification of equipment outside containment for high energy line breaks (HELB). This is an interim report of a potentially reportable item under provisions of 10CFR50.55(e). Our most recent interim report was logged TXX-4808, dated May 16, 1986.

We are continuing our evaluation and anticipate submitting our next report by September 19, 1986.

Very truly yours, j

i W. G. C u s :1 By:/ /

G. S. Keeley ,

Manager, NucT ticensing i

JCH/arh I

c - NRC Region IV (0 + 1 Copy)

Director, Inspection & Enforcement (15 copies)

U. S. Nuclear Regulatory Commission Washington, D.C. 20555 ,,

]

l 8607300110 860716 5 DR ADOCK 0500 4 . 6 / e4 g ,

.1 -- -

_