International, Submittal of Responses to 2nd Request for Additional Information for Review of Licensing Amendment Request 9374-2 for HI-STAR 80 Transportation Package
ML23178A233
Person / Time
Site: 07109374
Issue date: 06/27/2023
From: Manzione K
Holtec
To: Pierre Saverot
Office of Nuclear Material Safety and Safeguards, Document Control Desk
Shared Package
ML23178A232 List:
References
2370014-NRC, EPID L-2021-LLA-0130
Download: ML23178A233 (1)


Text

KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 June 27, 2023 Pierre Saverot, Project Manager - Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No.: 71-9374 (HI-STAR 80 Model)

EPID No.: L-2021-LLA-0130

Subject:

Submittal of Responses to 2nd Request for Additional Information for Review of Licensing Amendment Request 9374-2 for HI-STAR 80 Transportation Package

Reference:

[1] Second Request for Additional Information for the Review of the Model No. HI-STAR 80 Package, letter dated March 26, 2023 from P. Saverot (NRC) to K.

Manzione (Holtec)

Dear Mr. Saverot:

Holtec International appreciates the NRC staffs on-going review of the License Amendment Request (LAR) 9374-2 to the HI-STAR 80 Certificate of Compliance (CoC) Number 71-9374.

This letter contains the responses to the staffs request for additional information [1] in both proprietary and non-proprietary forms as enclosures 1 and 2. Enclosures 3 and 4 contain the updated Safety Analysis Report (SAR) for the HI-STAR 80 Package (both proprietary and non-proprietary versions).

Enclosures 5 and 6 contain supporting documents such as calculation packages and design documentation. Note that Enclosure 6 is considered Westinghouse proprietary information so contains an affidavit requesting that it be withheld from public disclosure. Enclosure 8 is an affidavit prepared in accordance with 10 CFR 2.390 requesting that Enclosures marked Holtec proprietary be withheld from public disclosure.

If you have any questions, then please contact me at 856-797-0900, ext. 3951.

Document ID: 2370014-NRC Page 1 of 2

KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Sincerely, Kimberly Manzione Director of Licensing Holtec International

Enclosures:

HI-STAR 80 Responses to Requests for Additional Information (Holtec Proprietary Information) : HI-STAR 80 Responses to Requests for Additional Information (Non-Proprietary) : HI-STAR 80 Safety Analysis Report (SAR), HI-2146261, Proposed Revision 4.B (Holtec Proprietary Information) : HI-STAR 80 Safety Analysis Report (SAR), HI-2146261, Proposed Revision 4 B (Non-Proprietary) : Shielding Analysis for HI-STAR 80, HI-2167211, Revision 8 (Holtec Proprietary Information) : SKB Quiver - Data for External Use, NRT 18-043 Revision 3 (Westinghouse Proprietary Information) : Affidavit CAW-23-024 for Enclosure 6 (Non-Proprietary) : Affidavit Pursuant to 10CFR2.390 to Withhold Information from Public Disclosure Document ID: 2370010-NRC Page 2 of 2