05000237/FIN-2011002-05
From kanterella
Revision as of 14:05, 30 September 2017 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Finding | |
---|---|
Title | |
Description | The inspectors identified a finding of very low safety significance and associated NCV of Dresden Technical Specification 5.4.1, for failing to maintain adequate procedures for implementing the emergency operating procedures (EOP). Specifically, the licensee developed and implemented procedures that altered an EOP mitigation strategy, without establishing and documenting the technical basis for the deviation from the Boiling Water Reactor Owners Group (BWROG) Emergency Procedure Guidelines (EPG). The licensee entered the issue into their corrective action program. Licensee corrective actions included revising three procedures to bring their mitigation strategy into alignment with the BWROG EPG. This issue was associated with the Procedure Quality attribute of the Mitigating Systems Cornerstone, and is more than minor, in that the licensee implemented an Emergency Operating Procedure mitigation strategy that deviated from the BWROG EPG, without providing adequate technical justification for the deviation, thereby affecting the cornerstone objective of ensuring that the licensee is capable of mitigating the undesirable consequences associated with an Anticipated Transient Without SCRAM (ATWS). The finding was determined to be of very low safety significance because no actual event requiring the use of deficient procedures occurred while the deficient procedures were in effect. The inspectors determined that the finding was not associated with a cross-cutting aspect because the implementation of the non-conservative ATWS mitigating actions occurred more than three years ago, and, therefore, was not reflective of current performance. |
Site: | Dresden |
---|---|
Report | IR 05000237/2011002 Section 1R11 |
Date counted | Mar 31, 2011 (2011Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.11 |
Inspectors (proximate) | C Zoia D Melendez -Colon C Phillips D Reeser R Baker M Ring T Go J Drape |
INPO aspect | |
' | |
Finding - Dresden - IR 05000237/2011002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Dresden) @ 2011Q1
Self-Identified List (Dresden)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||