Fukushima Near-Term Task Force Recommendation 2.3: Seismic Response Report
ML12342A133
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 11/12/2012
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
References
Download: ML12342A133 (445)


Text

{{#Wiki_filter:ENCLOSURE 1 SEQUOYAH NUCLEAR PLANT, UNIT 1 FUKUSHIMA NEAR-TERM TASK FORCE RECOMMENDATION 2.3: SEISMIC RESPONSE REPORT SEQUOYAH NUCLEAR PLANT -UNIT 2 FUKUSHIMA NEAR-TERM TASK FORCE RECOMMENDATION 2.3: SEISMIC RESPONSE REPORT 12-November-2012 WorleyParsons 633 Chestnut St. Suite 400 Chattanooga TN, 37450 Tel: 423-757-8020 Fax: 423-757-5869 www.worleyparsons.com WorleyParsons Services Pty Ltd ABN 61 001 279 812© Copyright 2012 WorleyParsons Services Pty Ltd NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 REV DESCRIPTION ORIG REVIEW WORLEY- DATE CLIENT DATE PARSONS APPROVAL APPROVAL 0 SON Unit 2 Seismic 5o 12-NPv-12 'rkerslJ.Edgr Walkdown Report 0.1tork .4.Summers /JEd~gar Page 2 of 444 177 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 Table of Contents 1. Executive Sum m ary ......................................................................................................... 4 2. Seism ic Licensing Basis ..................................................................................................... 5 2.1. G eneral Plant Description ............................................................................................ 5 2.2. G round Response Spectra ............................................................................................. 5 2.3. Structures ........................................................................................................................... 7 2.4. Equipm ent and System s ................................................... ....................................... 7 3. Personnel Q ualifications ...................................................................................................... 9 3.1. Equipm ent Selection Personnel ..................................................................................... 9 3.2. Seism ic W alkdow n Engineers ........................................................................................ 9 3.3. Licensing Basis Review ers ............................................................................................. 9 3.4. IPEEE Reviewers ........................................................................................................ 10 3.5. Peer Review Team ...................................................................................................... 10 4. Selection of Structures, System s and Com ponents ............................................................ 11 4.1. SW EL Selection .......................................................................................................... 11 4.2. SW EL Analysis ................................................................................................................. 12 5. Seism ic W alkdowns and Area W alk-Bys ............................................................................ 13 5.1. Seism ic W alkdow n Procedure ...................................................................................... 13 5.2. SW C & AW C Sum m ary ............................................................................................... 14 6. Licensing Basis Evaluations .............................................................................................. 15 6.1. Licensing Basis Calculations ........................................................................................ 15 6.2. Potential Seism ically Adverse Conditions .................................................................. 15 7. IPEEE Vulnerabilities Resolution Report ............................................................................ 18 7.1. IPEEE Description ........................................................................................................ 18 7.2. IPEEE Findings and Vulnerabilities ............................................................................ 18 7.3. NRC IPEEE Review ................................................................................................... 19 7.4. Response to IPEEE Review ....................................................................................... .19 8. Peer Review ............................................................................................................................ 21 9. References .............................................................................................................................. 22 10. Appendices ........................................................................................................................... 23 Appendix A: Resum es ........................................................................................................ 24 Appendix B: Base List I ..................................................................................................... 60 Appendix C: Base List 2 ...................................................................................................... 83 Appendix D: SW ELs and Area List ...................................................................................... 90 Appendix E: SW Cs .................................................................................................................. 97 Appendix F: AW Cs ................................................................................................................ 336 Appendix G : Peer Review Report ......................................................................................... 437 Page 3 of 444 rrr NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 1. Executive Summary As a result of the Fukushima Daiichi Nuclear Power Plant accident, the U.S. Nuclear Regulatory Commission required all US nuclear power plants to perform seismic walkdowns to identify and address degraded, non-conforming or unanalyzed conditions and to verify the current plant configuration with the current seismic licensing basis.The NRC Near-Term Task Force (NTTF) issued a report (Reference

1) that made a series of recommendations.

Subsequently, the NRC issued a 50.54(f) Letter (Reference

2) that requests information to assure that these recommendations are addressed by all U.S. nuclear power plants. This report provides guidance for conducting a seismic walkdown as required in the 50.54(f) Letter, Enclosure 3, Recommendation 2.3: Seismic.In support of conducting the NTTF-2.3 Seismic Walkdowns, the Electrical Power Research Institute (EPRI) issued a report entitled Seismic Walkdown Guidance (Reference
3) to provide instruction for uniform seismic walkdowns of all U.S. nuclear power plants. This document also includes guidance for reporting the findings of the required walkdowns.

At Unit 2 of the Sequoyah Nuclear Power Plant, a total of 119 general Seismic Category I equipment items were selected from the original IPEEE Safe Shutdown Equipment List (SSEL) to fulfill the requirements of the NTTF-2.3 Seismic Walkdowns. The selected items were located in various environments and included many different types of equipment from multiple safety systems. A total of 50 areas were included for area walk-bys. The equipment walkdowns and area walk-bys were performed by two teams, each consisting of two seismic engineers and operations personnel, between July 13, 2012 and November 9, 2012.All 119 equipment items in the Seismic Walkdown Equipment List (SWEL) were completed during the walkdown phase. Ten potentially adverse seismic conditions were found and addressed through the TVA Corrective Action Program.Page 4 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 2. Seismic Licensing Basis The seismic licensing basis for the Sequoyah Nuclear Power Plant is derived from Reference 4 -Sequoyah Nuclear Plant Living Final Safety Analysis Report Amendment 24.2.1. General Plant Description The Sequoyah Nuclear Power Plant site is located near the geographical center of Hamilton County, Tennessee, on a peninsula on the western shore of Chickamauga Lake at Tennessee River mile (TRM) 484.5. The Sequoyah site is approximately 7.5 miles northeast of the nearest city limit of Chattanooga, Tennessee, 14 miles west-northwest of Cleveland, Tennessee, and approximately 31 miles south-southwest of TVA's Watts Bar Nuclear Power Plant. The plant has been designed, built, and is operated by TVA and contains two identical units. Each of the two units employs a Pressurized Water Reactor Nuclear Steam Supply System with four coolant loops, furnished by Westinghouse Electric Corporation. Unit 2 began commercial operation on June 1, 1982.2.2. Ground Response Spectra The seismic design basis for Sequoyah Nuclear Power Plant is the 0.18g horizontal peak ground acceleration represented by the modified Housner-shape spectrum for Safe Shutdown Earthquake (SSE). Operating Basis Earthquake (OBE) is one-half of SSE ground acceleration. Vertical ground acceleration is two-thirds of the horizontal ground acceleration. Figure 1 illustrates the relationship between the 5% damped minimum design response spectra and the actual site seismic design response spectra for the SSE used in the design of rock-supported structures. Page 5 of 444 7NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2.Z oV0 SACT UAL DE IG4SPECTRA'*%.=n. INIMUM DESIN 0Z 4 .SPECTRA FpOw.44 0.04~~\Y "^INN*... ..01 .0;2 .04 .06 .08' .1 .2 4 .3 .a 1 4 4 4 K PERIOD (ýECS)Figure I -Comparison of Response Spectra for Safe Shutdown Earthquake, 5% damping Page 6 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 2.3. Structures The design of all Class I structures and facilities conformed to the applicable general codes or specifications including:

  • American Concrete Institute (ACI)o ACI 214-77 Recommended Practice for Evaluation of Strength Results of Concrete o ACI 315-65 Manual of Standard Practice for Detailing Reinforced Concrete Structures o ACI 318-63 Building Code Requirements for Reinforced Concrete o ACI 318-71 Building Code Requirements for Reinforced Concrete o ACI 318-77 Building Code Requirements for Reinforced Concrete o ACI 347-68 Recommended Practice for Concrete Formwork o ACI 305-72 Recommended Practice for Hot Weather Concreting o ACI 211.1-70 Recommended Practice for Selecting Proportions for Normal Weight Concrete o ACI 304-73 Recommended Practice for Measuring, Mixing, Transporting, and Placing Concrete" American Institute of Steel Construction (AISC)o "Specification for the Design, Fabrication, and Erection of Structural Steel for Buildings," February 12, 1969" American Welding Society (AWS): o "Code for Welding in Building Construction," AWS D1.0-69 as modified by TVA General Construction Specification G-29C.o "Structural Welding Code," AWS D1.1-72 as modified by TVA General Construction Specification G-29C.o "Recommended Practice for Welding Reinforcing Steel, Metal Inserts, and Connections in Reinforced Concrete Connections," AWS D12.1-61.* NRC Regulatory Guides: o Number 1.12 Instrumentation for Earthquakes o Number 1.31 Control of Stainless Steel Welding 2.4. Equipment and Systems Nuclear Steam Supply System (NSSS) components and equipment supplied by Westinghouse have been qualified in accordance with the applicable seismic qualification requirements.

Seismic qualification requirements for Seismic Category I systems and components are consistent with Institute of Electrical and Electronics Engineers (IEEE) Standard 344-1971.Page 7 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 Seismic Category I mechanical equipment has been qualified in accordance with the applicable seismic qualification requirements contained in Reference 4.Class I equipment and safety related piping were designed such that stress and deformation behavior were maintained within the allowable limits when subjected to normal operating conditions combined with the seismic effects resulting from the response to the OBE. In addition, the stresses that resulted from normal loads combined with the response to the SSE were limited so that no loss of function occurred, and the capability of making a safe and orderly plant shutdown was maintained. The allowable limits are defined in appropriate design standards including:

  • American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, 1986* American National Standards Institute (ANSI) Code for Pressure Piping ANSI B31.1.0, Power Piping, 1967* AISC Specification for the Design, Fabrication and Erection of Structural Steel for Buildings, February 12, 1969 Page 8 of 444 17' NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 3. Personnel Qualifications The personnel qualification for all individuals involved in the execution of the Fukushima Near-Term Task Force Recommendation 2.3: Seismic can be found in this section. Full resumes for the listed individuals can be found in Appendix A of this document.3.1. Equipment Selection Personnel The personnel who performed equipment selection and review are:* David Moore, Sequoyah Outage Management, Operations Assessor, Human Performance Manager, Operations Work Control Planning and Scheduling Manager, and Shift Manager for 35 years.* Larry Chandler, Sequoyah Reactor Operator and Senior Reactor Operator for 32 years.* Phillip York, Associate Structural Engineer with 5 years of engineering experience, including 2 years in the nuclear power industry.3.2. Seismic Walkdown Engineers The personnel who performed the seismic walkdowns are: " Steven Summers, Professional Engineer in the state of Pennsylvania with 8 years of engineering experience, including 3 years in the nuclear power industry." Robert Malone, Professional Engineer in the state of Pennsylvania with 7 years of engineering experience, including 2 years in the nuclear power industry.* Isaac Antanaitis, Structural Engineering associate with four years of experience in structural design (including seismic design) for various power generating applications" Phillip York* James Edgar, Professional Engineer in the state of Tennessee with 11 years of engineering experience, including 2 years in the nuclear power industry.3.3. Licensing Basis Reviewers The personnel who performed the licensing basis reviews:* Karen Carboni, Site Engineer at Sequoyah with extensive experience providing engineering support for the operating site." Glynna Wilson, Site Engineer at Sequoyah with extensive experience providing engineering support for the operating site.Page 9 of 444 INTTF Recommendation 2.3: Seismic Response Report I JSequoyah Unit 2 3.4. IPEEE Reviewers The personnel who performed review of IPEEE vulnerabilities are:* Phillip York" Joshua Best, Project Mechanical Engineer with 5 years engineering experience, including 4 years in the nuclear power industry.3.5. Peer Review Team The personnel involved in the peer review process are: " John Dizon, Over 30 years of experience in the field of civil and structural engineering, earthquake engineering, risk assessment and project management." Steve Eder, Over 30 years of experience in the field of civil and structural engineering, project management, seismic engineering, and risk management.

John Dizon is the Peer Review Team Leader.Page 10 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 4. Selection of Structures, Systems and Components The selection of Structures, Systems and Components (SSCs) for the Recommendation 2.3 Seismic walkdowns followed the guidelines provided in Reference 3 -The Electrical Power Research Institute's Seismic Walkdown Guidance.4.1. SWEL Selection The development of SWEL 1 began with the Safe Shutdown Equipment List (SSEL) that was developed as part of the Individual Plant Examination for External Events (IPEEE)implementation at Sequoyah, found in Reference 5 -Seismic Capability Walkdown for IPEEE. This list fulfills the requirements of Screens #1 through #3 found in the EPRI walkdown guidance document. The SSEL was then categorized by unit, location, system, equipment class, and safety function. These categories fulfill the Screen #4 requirements of systems, equipment types, and environments. Safety Function "0 -Support Function" was added in addition to the EPRI guidance to categorize equipment that does not perform one particular safety function but does support all five safety functions. The locations included in the SSEL include the: " Control Building* Auxiliary Building" Reactor Building* Diesel Generator Building* Emergency Raw Cooling Water Pump Station.The six safety functions are: 0. Support function 1. Reactor reactivity control 2. Reactor coolant pressure control 3. Reactor coolant inventory control 4. Decay heat removal 5. Containment function This categorized list is presented in Appendix B as Base List 1. After separating the data into the previously mentioned categories, a sample was selected from Base List 1 to represent all special considerations that were required by the EPRI Walkdown Guidance. This sample was reviewed and compared to plant documentation to locate any new or modified equipment, also required by EPRI Screen #4.In accordance with the EPRI guidance, SWEL 1 includes consideration of the importance of the contribution of risk for the SSCs. SWELl was compared to the Core Damage Frequency (CDF) and Large Early Release Frequency (LERF) Rankings, and any shared equipment was noted.Page 11 of 444 i71 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 Some of the equipment classes that were listed in the EPRI walkdown guidance were not covered in the original IPEEE SSEL, and therefore are not present in Base List 1.However, in order to include all of the classes of equipment, the scope of the selection was expanded for this seismic walkdown to include other Category I Safety Related equipment for the classes that were not previously covered.SWEL 1 represents the full list of equipment that was selected from Base List 1 and from the Category I equipment list. SWEL 1 can be found in Appendix D.Base List 2, presented in Appendix C, is a complete list of all spent fuel pool systems and equipment. SWEL 2 is derived from this list and includes any equipment or system that could cause rapid drain-down of the pool and accidental exposures of fuel assemblies. After review of spent fuel pool layout drawings and consulting with plant personnel, it was determined that no equipment or system failure could cause rapid drain-down of the pool and accidental exposure of the fuel assemblies. SWEL 2 can be found in Appendix D.4.2. SWEL Analysis The combined SWEL for Sequoyah Unit 2, which consists of 119 items of equipment, adequately addresses all criteria that were required for the selection of SSCs in the EPRI Seismic Walkdown Guidance. These criteria include a distribution of environments, systems, safety functions, and classes of equipment. The following items were selected in order to address the new and improved equipment criteria of EPRI Screen #4 for Sequoyah Unit 2: UNID Description SQN-2-INVB-250-QU-G 120V AC VITAL INVERTER 2-IV SQN-0-AHU-311-0023 MAIN CONTROL ROOM AHU B-B Table 1 -New and Improved Equipment Page 12 of 444 i'T NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 5. Seismic Walkdowns and Area Walk-Bys Guidance for performing the walkdowns and walk-bys required for Fukushima NTTF Recommendation 2.3 can be found in Reference 3 -The Electrical Power Research Institute's Seismic Walkdown Guidance.The walkdowns and walk-bys were conducted in accordance with this guideline and each was given a final status. If no issues were noted or only housekeeping and minor maintenance issues were noted during a walkdown or walk-by, a YES status was given to the selected piece of equipment or area. If a potentially adverse seismic condition was noted, a NO status was given and a Corrective Action Program (CAP) entry was written. If any equipment was inaccessible, or if a portion of an item of equipment was unobservable, an UNKNOWN status was given. It is noted that there were no inaccessible SWEL items at Sequoyah Unit 2.5.1. Seismic Walkdown Procedure One hundred and nineteen (119) Seismic Walkdowns Checklists (SWCs) were completed at Sequoyah Unit 2. These checklists can be found in Appendix E of this document. The primary types of potentially adverse seismic conditions that were addressed during these walkdowns include:* Bent, broken missing, or loose hardware* Corrosion that is more than moderate* Visible cracks in surrounding concrete" Impact of soft targets* Collapsing equipment" Inadequate line flexibility Fifty (50) Area Walk-by Checklists (AWCs) were completed at Sequoyah Unit 2. These checklists can be found in Appendix F of this document. The primary areas of observation for potentially adverse seismic conditions that were considered during these walk-bys include:* Anchorage of equipment* Cable/conduit raceways and HVAC ducts* Spatial interactions between equipment* Flooding/Spray hazards* Fire hazards* Housekeeping and temporary equipment Anchorage configuration for 55 items of equipment in Sequoyah Unit 2 was verified by drawings and/or calculations. Page 13 of 444 irr NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 For cabinets and panels that were selected for walkdown, NRC guidance was followed to determine which could and could not be opened for internal inspection. Undue safety hazards, operational hazards, or cabinets that required extensive disassembly were documented and only observable anchorage was included in those walkdowns. 5.2. SWC & AWC Summary The results documented by the SWCs and AWCs for Sequoyah Unit 2 is summarized below:* 111 SWCs and 39 AWCs resulted in a YES status* 8 SWCs and 11 AWCs resulted in a NO status o Potentially Adverse Seismic Condition 1 m Area 32- Surge Tank B Area o Potentially Adverse Seismic Condition 2 0 SQN-2-BDC-201-GM-A -480V Reactor MOV Board 2A2-A o Potentially Adverse Seismic Condition 3* SQN-0-BATB-250-QY-G (1-20) -125V Vital Batt. Rm IV Batteries* SQN-0-BATB-250-QY-G (21-40) -125V Vital Batt. Rm IV Batteries* SQN-2-INVB-250-QU-G -120V AC Vital Inverter 2-IV* SQN-2-CHGB-250-QJ-G -125V DC Vital Battery Charger IV* Area 21 -125V Battery Room IV* Area 22 -480V Board Room 2B o Potentially Adverse Seismic Condition 4* SQN-2-LOCL-500-0222B -Floor Panel Auxiliary Building* Area 25 -RHR Pump Area* Area 38 -Auxiliary Feedwater Pump B Area* Area 43 -SI Pump Area o Potentially Adverse Seismic Condition 5 0 Area 20 -125V Vital Battery Room III o Potentially Adverse Seismic Condition 6* SQN-2-GEND-085-DH/3B -Control Rod Drive Generator 2B* Area 30- CRDM Room o Potentially Adverse Seismic Condition 7 n Area 36 -6.9kV Shutdown Board Room B o Potentially Adverse Seismic Condition 8 a Area 7 -2A Pump Room o Potentially Adverse Seismic Condition 9 0 Area 37 -Control Bldg. 669 Mechanical Room o Potentially Adverse Seismic Condition 10 W SQN-2-AHU-030-0088 -Control Rod Drive Cooling Unit C-A Page 14 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 6. Licensing Basis Evaluations 6.1. Licensing Basis Calculations When a potentially adverse seismic condition was identified at SQN, the condition was entered into the corrective action program. No licensing basis evaluations were performed by the walkdown team per TVA expectations to communicate any potential operability concerns as soon as they were identified. Due to the nature of this process, no calculations were performed by the walkdown team for licensing basis evaluations before the CAP entry was submitted. All licensing basis determinations were performed by SQN engineering on each CAP entry.Multiple CAP entries were generated during the seismic walkdown process at Sequoyah Unit 2. There were a total of ten CAP entries that were considered potential seismically adverse conditions. No degraded or non-conforming conditions were found during the course of this walkdown process.6.2. Potential Seismically Adverse Conditions The potentially seismically adverse seismic conditions summarized above are described in more detail below.6.2.1. Potentially Adverse Seismic Condition 1 During the walk-by for the Surge Tank B Area, a Radiation Control Cabinet was found chained at a single point to a steel column. To prevent sliding or tipping into the air compressor, it was recommended that the cabinet be anchored in a second location. A CAP entry was submitted to address this issue, and the cabinet was secured to prevent movement during a seismic event.6.2.2. Potentially Adverse Seismic Condition 2 A temporary cooling fan was noted to be improperly restrained in the 480V Board Room 2A. This fan was secured with a chain to an appropriate structure, but the restraint was in a location that would allow the fan to move and tip in a manner that could cause it to strike a nearby electrical cabinet, 2-BDC-201-GM-A. Since many of the relays contained in this cabinet are sensitive, this condition was considered to be potentially seismically adverse. A CAP entry was submitted to address this issue and the fan was removed.Page 15 of 444 571 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 6.2.3. Potentially Adverse Seismic Condition 3 During the walkdown for equipment in the 125V Vital Battery Room IV and the 480V Board Room 2B, a crack was noted in a common masonry block wall. The crack was observed at the top of the wall, directly beneath the steel angle used to connect the wall to the ceiling. The crack is approximately 6' long and was visible on both sides of the masonry wall. This crack was judged to pose a potentially adverse seismic condition to three different items of equipment including the 120V AC Vital Inverter 2-IV and 125V DC Vital Battery Charger IV in the 480V Board Room and battery racks 1-20 and 21-40 in the 125V Vital Battery Room IV. A CAP entry was submitted to address the issue and the wall was deemed adequate to perform its intended function.6.2.4. Potentially Adverse Seismic Condition 4 During the equipment walkdown for SQN-2-LOCL-500-0222B and the area walk-bys for Area 25 -RHR Pump Area, Area 38 -Auxiliary Feed water Pump B Area, and Area 43 -SI Pump Area, it was noted that 55-gallon drums in the vicinity of the equipment were not properly restrained. Per TVA Procedure, the geometry of these drums require seismic restraint. A CAP entry was submitted to address the issue and the drums were removed from the affected areas.6.2.5. Potentially Adverse Seismic Condition 5 During the area walk-by associated with 125V Battery Room Ill, it was observed that the sink cabinet in this room was not restrained. During a seismic event, the cabinet could move away from the wall, causing the water supply line to rupture and cause a spray hazard onto the battery racks. A CAP entry was submitted to address this issue and a calculation was found that determined the unrestrained cabinet is not a seismic concern and would not cause a spray hazard in case of a seismic event. No further action required.6.2.6. Potentially Adverse Seismic Condition 6 An anchor bolt was noted to be missing from a duct support above the Control Rod Drive Generator 2B (2-GEND-085-DH/3B) in the Control Rod Drive Mechanism Room.The duct support with the missing bolt is a frame support, cantilevered from the wall, with two baseplates connecting it to the concrete. These baseplates have four bolt holes each, one of which is missing a bolt in the top plate. A CAP entry was submitted to address this issue and the support was deemed adequate to perform its intended function.Page 16 of 444 EiI NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 6.2.7. Potentially Adverse Seismic Condition 7 A scaffold with potentially inadequate restraint was noted in the 6.9kV Shutdown Board Room B. This scaffolding was found in front of compartments 10 and 11 of the Unit 2 6900V Shutdown Board (2-BDB-202-CP) and was observed to be anchored at only one point by a loosely hung chain and could tip into overhead lighting and the shutdown board. A CAP entry was submitted to address this issue. The scaffolding was later observed to be adequately restrained on its upper corner to a permanent pipe support cantilevered from the ceiling. No further action required.6.2.8. Potentially Adverse Seismic Condition 8 During the area walk-by of the ECRW Pump Room 2A-A, a flammable materials cabinet was noted to have a broken latch on its door. It was also not anchored to the floor or wall. During a seismic event, the door could open or the cabinet could tip, causing the enclosed flammable material to spill from the cabinet. This would present a potential fire hazard in the area. A CAP entry was submitted to address this issue and a hasp and lock was verified to have been installed by mechanical maintenance. No further action required.6.2.9. Potentially Adverse Seismic Condition 9 While performing the walk-by for the Control Building El. 669 Mechanical Room, a bolt and nut were observed to be not fully engaged on a System 26 Fire Protection pipe hanger. The hanger is located 12 feet above the floor, on the east side, between the A and B EBR AHU's, just above the cross connection between the AHU's, closer to the A AHU. A CAP entry was submitted to address the issue and the pipe hanger was deemed adequate to perform its intended function and was corrected by work order.6.2.10. Potentially Adverse Seismic Condition 10 While performing the walkdown for the Rod Drive Cooling Unit C-A, SQN-2-AHU-030-0088, a missing bolt was observed that connects the cooling unit to the steel support frame. A CAP entry was submitted to address the issue and work is planned to replace the missing bolt.Page 17 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 7. IPEEE Vulnerabilities Resolution Report Information for the IPEEE Vulnerabilities Resolution Report is derived from Reference 5-Seismic Capability Walkdown for IPEEE and Reference 6 -Sequoyah Nuclear Plant (SQN) -Units I and 2 -Response to Request for Additional Information on the Individual Plant Examination of External Events.7.1. IPEEE Description In Generic Letter 88-20, Supplement 4, the US Nuclear Regulatory Commission (NRC)requested that the utilities for all active nuclear power plants in the United States perform an evaluation of their nuclear power generating facilities to identify any vulnerabilities associated with the occurrence of several plant-specific external events, and to access the impact of these vulnerabilities on the potential for plant core damage or radioactive material release. This program, designated the Individual Plant Examination of External Events (IPEEE), is a corollary program to the Individual Plant Examination (IPE) which focused on the vulnerabilities associated with the occurrence of external events.After NRC review of the Sequoyah IPEEE Report, it was found that the review level earthquake (RLE) was characterized in a manner that was inconsistent with NUREG-1407, the governing document for IPEEE seismic events. The intent of NUREG-1407 is that the RLE control motion for SQN (which is predominantly a rock site) should be specified at rock outcrop as the NUREG/CR-0098 median 5% damped spectral shape for rock, anchored to a PGA of 0.30g at rock outcrop. The SQN IPEEE appropriately specified the RLE spectral shape as the NUREG/CR-0098 median rock spectrum at rock outcrop, but inappropriately specified the RLE PGA of 0.30g as occurring at the free-field soil surface.7.2. IPEEE Findings and Vulnerabilities The IPEEE Report for the Sequoyah Nuclear Plant addressed multiple vulnerabilities that were identified during the original IPEEE walkdown process. A full list of these vulnerabilities can be found in Reference 5 -Seismic Capability Walkdown for IPEEE.A sample of this list was selected for Recommendation 2.3 walkdowns, and this equipment was added to the SWEL for Sequoyah Unit 2. These selected items of equipment, the issues noted, and the resolutions can be found in Table 2.Page 18 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 UNID Description Resolution SQN-2-BDC-201-FL-A Inadequate Anchorage / Interaction Design Change SQN-2-BDC-201-FN-B Inadequate Anchorage Design Change SQN-2-BDC-201-FU-B 1 of 4 bolts missing: 2 of 7 bays Calculation SQN-2-CLR-030-0178 2 of 6 anchor bolts missing Design Change SQN-2-INVB-250-QU-G Weak way bending channels for Similar Design Approved inverters SQN-2-HEX-074-0015 Support frame tabs to anchor Design Change plates for HX SQN-2-HEX-074-0027 Support frame tabs to anchor Design Change plates for HX DesignChange Table 2 -IPEEE Issues and Resolutions 7.3. NRC IPEEE Review Subsequent to these original SQN high confidence low probability of failure (HCLPF)capacity bounding evaluations and during the NRC Request for Additional Information (RAI) process related to the definition of RLE control motion, the SQN IPEEE RLE was redefined from the free-field soil surface to rock outcrop. As a result, all of the HCLPF capacities as determined by the conservative bounding evaluations were scaled down by a factor of 0.75. Due to this scaling, the HCLPF capacity for many items dropped to below 0.30g (for RLE defined at rock outcrop). However, at that time no additional effort was expended to review in more detail and improve (increase) these HCLPF capacities, especially by eliminating some of the simplifying conservative approximations as used in the original bounding evaluations. A full list of these items can be found in Reference 6 -Sequoyah Nuclear Plant (SQN) -Units I and 2 -Response to Request for Additional Information on the Individual Plant Examination of External Events. A sample of this list was selected for Recommendation 2.3 walkdowns, and this equipment was added to the SWEL 1 for Sequoyah Unit 2.7.4. Response to IPEEE Review The following table shows the items that were identified as IPEEE outliers after the NRC RAI.Page 19 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 Item Equipment Description 1 RHR Heat Exchangers (modified) 2 Main Control Room AHUs 3 Ice Condenser 4 125V Vital Battery Chargers 5 480 V Shutdown Transformers 6 480 V Shutdown Boards 7 6.9 kV Shutdown Boards 8 Regenerative Heat Exchangers 480 V Diesel Aux Boards 480 V Reactor MOV Boards 480V Control & Aux Bldg. Vent Boards 480V Reactor Vent Boards 10 RHR Pumps 120 VAC Vital Inverters (modified) 120 VAC Vital Inverters (replaced) 12 Pipe Chase Coolers (repaired) Table 3 -Revised HCLPF Equipment The statuses of all IPEEE outliers which were not corrected through physical modification were resolved through re-calculation of the appropriate HCLPF capacities. The 480V Shutdown Transformers required a minor anchorage modification. All IPEEE outliers are now resolved and have minimum HCLPF Capacities above 0.3g.Page 20 of 444 i71 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 8. Peer Review A peer review was performed in accordance with References 2 and 3. The peer review process involved considerable interaction with the review teams, and was performed throughout all phases of the effort including the following:

  • Selection of the SSCs included on the SWEL* In-plant walkdown observations and completed checklists for the Seismic Walkdowns and Area Walk-Bys*. Identified potentially adverse seismic conditions, utilization of the CAP process, and associated licensing basis review considerations 0 Submittal report In summary, the peer review results are confirmatory and fully supportive of the evaluations and findings as described in this report. The completed peer review report is included as Appendix G to this report.Page 21 of 444 NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 9. References Reference Document Title Document Preparer No. Number 1 Recommendations for Enhancing N/A United States Reactor Safety in the 2 1 st Century Nuclear Regulatory Commission 2 Letter: Request for Information N/A United States Pursuant to Title 10 of the Code of Nuclear Federal Regulations 50.54 (f) Regulatory Regarding Recommendations 2.1, Commission 2.3, and 9.3, of the Near-Term Task Force Review of Insights from the Fukushima Daiichi Accident 3 Seismic Walkdown Guidance for EPRI Report Electric Power Resolution of Fukushima Near-Term 1025286 Research Task Force Recommendation 2.3: Institute Seismic 4 Sequoyah Nuclear Plant Living Final SQN-19 Tennessee Safety Analysis Report Amendment Valley 24 Authority 5 Seismic Capability Walkdown for SCG-5M-0012 Tennessee IPEEE Valley Authority 6 Sequoyah Nuclear Plant (SQN) -N/A Tennessee Units 1 and 2 -Response to Valley Request for Additional Information Authority on the Individual Plant Examination of External Events (IPEEE) (TAC NOS. M83674 and M83675)Page 22 of 444 iTJ NTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 10. Appendices Page 23 of 444 INTTF Recommendation 2.3: Seismic Response Report Sequoyah Unit 2 Appendix A: Resumes Resumes included in this Appendix are alphabetized by last name." Isaac Antanaitis

-Walkdown Engineer* Joshua Best -Fukushima Project Engineer* Karen Carboni -Site Engineer* Larry Chandler -Retired SRO* John Dizon -Facility Risk Consultants

  • Steve Eder -Facility Risk Consultants" James Edgar -Lead Technical Engineer* Robert Malone -Unit 2 Team Leader* David Moore -Retired SRO* Steven Summers -Lead Engineer* Glynna Wilson -Site Engineer* Phillip York -Walkdown Engineer Page 24 of 444 WorleyParsons Isaac Antanaitis, E.I.T.resources

& energy Structural Engineer-in-Training Resume

SUMMARY

Structural Engineer-in-Training with four years of experience with WodeyParsons in analysis and design of structural steel, ductwork, buckstays, selective catalytic reduction (SCR) reactors, and structural concrete. Experience includes using STAAD models, as well as using other software including Microsoft Excel and MathCAD to assist in the design process. Familiar with 9 1h, 1 3 th, and 1 4 th Ed. AISC Steel Manuals, ACI 318, ACI 301, ACI 350, ASME BTH-1-2005, Design of Welded Structures (Blodgett), ASCE 7, U.S. Core of Engineer Design Guides for water-containing structures, and various AISC Design Guides. Experience also includes responsible engineering roles, project integration engineering (work-share facilitation), and assisting in business development related to subcontracting efforts with qualified small, minority, and woman-owned businesses. EXPERIENCE 2008 -Present Structural Engineer-in-Training, WorleyParsons, Chattanooga, Tennessee Arizona Public Service (APS) -Four Corners 2013 Capital Budget Items (CBI) Development. Primary responsibilities include coordination with APS plant personnel and prospective vendors to develop complete CBI packages (including scope, schedule, and budget for start to finish execution of capital projects) for submission to APS approval board.APS -Cholla 2013 Capital Budget Items (CBI) Development. Primary responsibilities include coordination with APS plant personnel and prospective vendors to develop complete CBI packages (including scope, schedule, and budget for start to finish execution of capital projects) for submission to APS approval board.Tennessee Valley Authority (TVA) -Kingston Fossil Plant (KIF) Unit Isolation Dampers Project. Primary responsibilities include performing the responsible engineering role for the plant-funded tasks associated with this project. This includes the development of the DCN (Design Change Notification) package, maintaining the project schedule, leading project status and design review meetings, and coordinating with plant personnel, vendors, and TVA Fossil Engineering Design (FED).2011 TVA -KIF Coal Unloader Project. Primary responsibilities include the development of a STAAD model of the concrete coal building for use in the overall structural analyses performed for the project. Responsibilities also include developing the final deliverable DCN (Design Change Notification) package.APS -Redhawk Cooling Tower Inspection. Primary responsibilities include assisting in the inspection and condition assessment of the structural components of the cooling tower for Units 1 and 2.TVA -KIF Unit 6 Condenser Cooling Water (CCW) Tunnel Inspections. Primary responsibilities include preparation for and execution of cooling water intake and discharge tunnel inspections, preparation of job safety analysis, and origination of tunnel inspection reports American Electric Power (AEP) Rockport Duct Inspection. Primary responsibilities include assisting in the inspection of various runs of back-end flue-gas ductwork in support of the Phase 1 engineering study for the Unit 1 SCR and FGD Retrofit Project.TVA -Paradise Fossil Plant (PAF) Limestone Scales Project. Prmary responsibilities include the design of reinforcement for existing limestone conveyor support steel to meet vendor requirements for new limestone scales. Responsibilities also include coordination with construction personnel. Design work includes delivering calculations and detailed engineering sketches.002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 1 Rev 6 (03-Feb-09) Page 25 of 444 Ec:oNomicý

  • WorleyParsons resources

& energy Isaac Antanaitis, E.I.T.Structural Engineer-in-Training Resume 2010-2011 2010 TVA- Colbert Fossil Plant (COF) ADEM Consent Order Project. Prmary responsibilities include the design of a concrete sump structure and associated support steel for the required chopper pump and access platforms. Responsibilities also include the design of a concrete foundation for electrical equipment, and coordination with construction personnel. Design work includes delivering calculations and detailed engineering sketches.U.S. Steel -Pro-Tec Annealing Line. Primary responsibilities include preliminary design of the concrete post-finishing pit for the development of construction bid drawings.TVA -Cumberland Fossil Plant (CUF) Unit I Bottom Ash Hopper Replacement Project.Primary responsibilities include the development of engineering estimates, project planning documents, and construction bid work scoping documents, as well as the design of: 1) post-installed epoxy anchors for hopper columns, 2) support steel for hopper platforms and piping, and 3)evaluation of sump pit support steel for demolition and construction loads. Design work includes delivering calculations and detailed engineering sketches.U.S. Steel -Fairfield Works Fall Protection. Primary responsibilities included providing engineering recommendations in the development of design drawings documenting required installation of fall protection system components. Responsibilities included performing field walk-downs of 44 overhead cranes in the hot strip mill, sheet mill, dual line mill, and cold mill at Fairfield Works.TVA -Bull Run Fossil Plant (BRF) CCW Inspection. Primary responsibilities included preparation for and execution of cooling water discharge tunnel inspection, including preparation of job safety analysis and origination of tunnel inspection report.TVA -Gallatin Fossil Plant (GAF) and KIF CCW Inspections. Primary responsibilities included preparation for and execution of cooling water intake and discharge tunnel inspections. For KIF tunnel inspections, primary responsibilities also included preparation of job safety analysis and origination of tunnel inspection reports.Dominion -Mount Storm Project Engineering. Primary responsibilities included design of stop logs and cooling water intake structure. Design work included delivering calculations and detailed engineering sketches. The design of each stop log included considerations to accommodate dry maintenance of spillway gates, including: structural steel design (with corrosion allowance) for applicable load from pressure head, rubber seal selection and arrangement, and construction splicing scheme for shipping and field erection purposes. Primary intake structure responsibilities included developing design loads, performing stability analysis, creating and analyzing STAAD models, and designing the geometry and reinforcement for the walls and foundation of the concrete structure. Project responsibilities also include work related to the preparation and development of specifications and engineering requisition documents. Southern Company -Plant Scherer Units 1-4 Pressure Upgrade. Primary responsibilities included updating existing drawings with new load data, and providing connection modifications for existing precipitator steel vertical bracing (Units 3 and 4).TVA -CUF Unit 2 Bottom Ash Hopper Replacement Project. Primary responsibilities included design of post-installed epoxy anchors for hopper columns, and steel to support hopper platforms and piping. Responsibilities also included providing engineering support for hopper installation and removal plans, as well as for construction phase field adjustments. TVA -John Sevier Fossil Plant (JSF) and GAF Stack Platform Extension As-built Field Verification. Primary responsibilities included providing verification of as-built information for chimney platform modification work by aiding in platform safety inspection, measuring and 2009-2010 2009 utvc-vuu-t.rr-u 0 ~UU~0'40) rlNr4JUSO torporme nase rage i Rev-000-CPF-016 (UU84) 6H(-0-e-9 Rev 6 (03-Feb-09) Corporate 6ase Page 26 of 444 Pmage 2 EcoNomicý l WorleyParsons Isaac Antanaitis, E.I.T.resources &energy Structural Engineer-in-Training Resume documenting dimensions of platforms and instruments, and creating sketch amendments for structural designers. TVA -BRF Lifting Device Qualification. Primary responsibilities included rating the capacities of various lifting devices (including monorails, below the hook lifting beams, and a forklift lifting attachment), providing a maximum load rating for mezzanine storage floors, and performing a crane uprate qualification. The crane uprate qualification included calculation of the maximum capacities of the pulverizer lifting crane and corresponding support steel.TVA -CUF Unit 2 SCR Field Weld Inspection and Qualification. Primary responsibilities included visually inspecting beam connection welds inside SCR box, determining structural condition of these welds, and documenting and reporting assessments to responsible plant personnel. CPS Energy -Deely Unit 2 SCR Proposal. Primary responsibilities included providing ductwork and steel material estimates. Responsibilities also included creating and analyzing STAAD models to verify foundation modification design loads.TVA -JSF and PAF Stack Platform Extensions. Primary responsibilities included providing baseline information for chimney platform modification work by aiding in platform safety inspection, measuring and documenting dimensions of platforms and instruments, and creating sketch amendments for structural designers. 2008 -2009 R.C. Cape May Holdings -B.L. England Unit 2 SCR Project Engineering. SCR reactor primary responsibilities included creating and analyzing STAAD models for SCR reactor box. Structural steel primary responsibilities included submitting calculations and engineering sketches for base plates, anchor bolts, and column splices. Responsibilities also included submitting support steel calculations and sketches for platforms and stair towers.2008 Alstom -Keyspan Northport Project Engineering. Ductwork primary responsibilities included creating and analyzing STAAD models which integrate new ductwork and existing support steel, delivering detailed design 'sketches, and submitting hand calculation packages. Structural steel primary responsibilities included analyzing existing support steel and recommending specific modifications to accommodate the new ductwork, delivering detailed design sketches, and submitting hand calculation packages. Buckstays primary responsibilities included analyzing existing buckstays and designing new buckstays for the addition of new separated over-fire air ducts.Alstom -Pacificorp Project Engineering. Ductwork primary responsibilities included creating and analyzing STAAD models for ductwork (both existing ducts and modifications of existing ducts), delivering detailed design sketches, submitting hand calculation packages, and writing sections of the design modification report pertaining to the aforementioned ductwork.PPL Global -Sunbury Project, Phase II Engineering. Ductwork primary responsibilities include creating and analyzing STAAD models for new ductwork, delivering detailed design sketches, and submitting hand calculation packages. Structural steel primary responsibilities included creating, integrating, and analyzing STAAD models for new support steel, delivering detailed design sketches, and submitting hand calculation packages.2007 -2008 Civil Engineering Intern, J. Farrow, P. E. & Associates, Collegedale, Tennessee Labrador Heights (Development). Provided site design layouts, roadway designs, grading plans, and construction plan setup for the project. Developed the storm water pollution prevention plan and the aquatic resource alteration permit submittals. London Lane (Development). Provided site design layouts, roadway designs, grading plans, and construction plan setup for the project. Created bid estimation computational tool for the project.002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 3 Rev 6 (03-Feb-09) Page 27 of 444 EcoNomic

  • WorleyParsons resources

& energy Isaac Antanaitis, E.I.T.Structural Engineer-in-Training Resume 2006 2004-2005 Stonegate (Development). Performed site plan revisions and general drafting tasks as directed by supervising engineers. Engineering Intern, Tennessee Valley Authority, Chattanooga, Tennessee River System Operations -Water Resource Cataloguing System. Provided support for engineers in the analysis of water resource records from regions throughout the Tennessee Valley Watershed. Aided in the further development of the organizational system by which water resource records are tracked and cataloged. Field Service Technician, Vibration Control Engineering, Nashville, Tennessee Nashville Courthouse -Underground Parking Lot. Installed, serviced, and retrieved data from digital and analog seismographs through computer interface and manual documentation. Reported seismic data to responsible engineers and blasting contractors. Wolf Chase (Development). Provided documentation of structural damage to engineers through the use of field sketches, notes, and digital photography. Initiated direct interaction with property owners potentially affected by the construction project.Hicks Road -Sewer Line Installation. Set up meeting times and coordinated pre-blast precautionary measures with construction industry representatives. Provided documentation of structural damage to engineers through the use of field sketches, notes, and digital photography. EDUCATION B.S., Engineering: Civil, University of Tennessee, Chattanooga, Tennessee, 2008 B.S., Mathematics: Technology, Bryan College, 2004 REGISTRATIONS/AFFILIATIONS Engineering Intern (E.I.T.), Tennessee No. 26439, 2007 Vice-President -Chattanooga Chapter of Engineers Without Borders SPECIFIC TECHNICAL EXPERTISE/SPECIALIST COURSES Computer Skills: STAAD.Pro 2006, 2007, and V8i SmartPlant Microsoft Office AutoCAD 2004, 2006, and 2008 MathCAD RISA Baseplate 002-000-CPF-016 (007W48) HRF-M033 Rev 6 (03-Feb-09) Corporate Base Page 28 of 444 Page 4 EcoNomics Joshua H. Best jhbestgtva.gov or 1oshua.H.Bestgsargentlundy.com TVA Fukushima Response Team Project Engineer -Civil Design Experience S&L, LLC TVA Fukushima Response Team Project Engineer -Civil Design Dec. 2011 -Present-Primary technical lead for NRC's request for information under 10 CFR 50.54(f)Recommendations 2.1 -Seismic and Flooding Re-evaluations and 2.3 -- Seismic and Flooding walk downs including developing project strategy, project scoping, developing and maintaining project schedules and budgets, participating in industry meetings and teleconferences, and contractor oversight. -Responsible for supporting all civil design functions associated with response to NRC "Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond Design Basis External Events" as required under EA-12-049. S&L, LLC. Mechanical Senior Associate -Pipe Stress Analyst June 2008 to Nov. 2011" ASME Class 2 and 3 and B31.1 piping and component qualification using TVA TPIPE piping analysis software and hand calculations" Knowledge of AMSE B31.1 and ASME Section III and VIII code requirements" Responsible for Minimum Wall Calculations (FAC Evaluations), Component Qualifications (valves and nozzles), Commodity Clearance Evaluations, Temporary Shielding Requests (pipe stress qualification), and Functional Evaluations for Plant Operability

  • Task Manager for numerous design change packages at Browns Ferry, Watts Bar and Sequoyah nuclear plants including responsibility for scoping and maintaining project schedule, budget, and interdisciplinary work flow Tennessee Valley Authority, Fossil Power Group, Intern June 2007 -May 2008 Technical Support Services (Metallurgy and Welding)Memberships-Licensed Engineering Intern in Tennessee (Passed Fundamentals of Engineering Exam (October 2007))*Member of American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE)-Member of American Society of Mechanical Engineers (ASME)Education BSME, Mechanical Engineering:

May 2008 University of Tennessee at Chattanooga, Chattanooga, TN Focus: Energy Systems Related Course Work: Thermodynamics, Thermal Component Design, Advanced Fluids, Energy Conversion Bachelor of Arts, Natural Science: May 2008 Covenant College, Lookout Mountain, GA Related course work: Physics, Chemistry, and Mathematics Page 29 of 444 Karen Carboni

SUMMARY

Civil Engineer with 7 years of experience in design engineering with the Tennessee Valley Authority. Job Experience includes designing piping modifications with plant system, equipment seismic qualification, piping seismic analysis, development of design change packages, performing functional evaluations and other various roles of a Civil Engineer. Familiar with ASME Section III and B31.1 for piping. Proficient with design software including and TVA-PIPE and MathCAD.EXPERIENCE Tennessee Valley Authority-Served as a Civil Engineer within the Civil Engineering Design Group at Chattanooga Office Complex from September 2005 to October 2006 and at Sequoyah Nuclear Plant since October 2006. Is qualified in Equipment Seismic Qualification and performed numerous evaluations of equipment during the procurement process. Qualified in piping analysis and evaluate modifications to piping systems to address plant needs. Responsible for piping analysis and development of design change documentation. Familiar with the TVA CAP process and how it is used for problem identification and resolution. Other responsibilities include field support, design change packages, verification of others work, functional evaluations, and interface with other departments within and outside of the Engineering Organization. EDUCATION B.S., Mechanical Engineering, University of Tennessee, Chattanooga, Tennessee, 2005 Page 30 of 444 William L. Chandler Professional Experience I was employed by TVA from 1980 until 2012. I was a Reactor Operator from 1989 to 1998. From 1998 thru 2012 I held the position of Senior Reactor Operator/ Unit Supervisor. I was responsible for the safe operation of a nuclear unit reactor, oversight of the Unit operators, review of weekly work schedules, approval of all unit work and coordination between crafts for inspections and ongoing work.Page 31 of 444 JOHN 0. DIZON, P.E.PROFESSIONAL HISTORY Facility Risk Consultants, Inc., Huntsville, Alabama, President, 2002-present ABS Consulting (formerly EQE International), Oakland, California, Director and Vice President of Facility Risk Division, 2000-2002 EQE International, Oakland, California, Vice President, 1998-2000; Associate, 1991-1998; Senior Engineer, 1986-1991 Engineering Decision Analysis Company, Cupertino, California, Senior Engineer, 1984-1986 General Electric Company, San Jose, California, Senior Engineer., 1984 URS/John A. Blume & Associates, San Francisco, California, Senior Engineer, 1982-1984; Associate Engineer, 1977-1980 Structural Systems Engineering, Inc., Lafayette, California, Senior Engineer, 1980-1982 Stanford University, John A. Blume Earthquake Engineering Center, Palo Alto, California, Teaching and Research Assistant, 1975-1977 PROFESSIONAL EXPERIENCE Mr. Dizon has over 30 years of experience in the field of civil and structural engineering, earthquake engineering, risk assessment and project management. He has extensive knowledge in the areas of seismic analyses and design assessments of primary structures and piping systems, seismic upgrade and retrofit design, seismic qualification of mechanical and electrical systems and components, and technical development of seismic evaluation criteria and programs for various industries, including power, oil and gas, petrochemical, and high tech process and manufacturing facilities. Mr. Dizon has undertaken and managed a wide variety of seismic projects, ranging from traditional structural engineering design and seismic retrofits to complex nuclear power plant and DOE facilities' seismic verification projects. He is also a guest instructor for the ASME Continuing Education Institute on seismic design and retrofit of piping systems and mechanical equipment. At present, Mr. Dizon is primarily involved with Tennessee Valley Authority (TVA), under a subcontract with Bechtel Power Corporation, in providing engineering consulting services for various structural and seismic-related civil issues in support of Watts Bar Nuclear Power Plant Unit 2 Completion Project. He also provides seismic consulting services to other industries, including defense contractors and commercial equipment manufacturers, among others.As President of Facility Risk Consultants, Mr. Dizon is responsible for business development and project management activities, including managing all associated tasks under a subcontract with Bechtel Power Corporation for seismic-related civil issues associated with the recently completed Browns Ferry Unit 1 Restart Project for Tennessee Valley Authority. The seismic works included USI A-46/IPEEE implementation programs, seismic II/I spray hazard evaluations, new cable routing utilizing the SQUG/GIP methodology, MSIV seismic ruggedness verification, among others. Furthermore, he was also actively involved in the development of seismic II/I design criteria for distribution systems and equipment for 1 FACILITY RISK CONSULTANTS, Inc.Page 32 of 444 JOHN 0. DIZON, P.E.DOE's PDCF project, under a subcontract with the Washington Group, Inc.; and in the seismic qualification of various essential equipment for DoD's GMD project, under a subcontract with Bechtel National, Inc. and its vendors. In addition, Mr. Dizon has participated as a subject matter expert witness in a litigation project for a large foreign company in the area of seismic performance of structures, piping systems and associated equipment associated with earthquake damges in a coal-fired power plant located in South America.As EQE Project Manager for various seismic programs associated with the restart of Browns Ferry Units 2 and 3, Mr. Dizon was responsible for all engineering activities associated with USI A-46 resolution and seismic IPEEE implementation; seismic proximity and II/I spray interaction evaluations; MSIV seismic ruggedness verification; cable tray and conduit raceway and supports; and HVAC support evaluation programs. These activities consisted of seismic criteria development, seismic walkdown assessments and mitigation of findings, including retrofit designs and plant upgrades. He was also responsible for the A-46 seismic evaluation program for major equipment items at Davis-Besse, Duane Arnold and H.B.Robinson power plants. Mr. Dizon also served as Project Manager for the HVAC seismic verification program at Salem Nuclear Plant, MSIV seismic projects at Hope Creek and Brunswick plants, and participated in a number of related seismic evaluation projects at Sequoyah, Watts Bar, Bellefonte, Pickering A, Bruce A, Forsmark, Liebstadt, among others.As Managing Director of EQE's Hsinchu, Taiwan project office following the 1999 Chi-Chi earthquake, he was in charge of the region's business development and project management. Mr. Dizon managed a number of seismic risk assessment and structural upgrade projects for the high tech industry, including seismic consultation on a number of projects for Taiwan Semiconductor Manufacturing Co., seismic strengthening projects for United Microelectronics, Applied Materials, Winbond Electronics and Macronix International in Taiwan. In addition, he also managed the seismic upgrades for the Cypress Semiconductor and Amkor facilities and seismic design review project for IBM in the Philippines, seismic risk assessment for AMP facilities in Japan, and seismic assessment of structural and non-structural components of clean room facilities at several Intel fab plants in the Northwest region in U.S., among others.As Group Manager for EQE at the US Department of Energy Savannah River Site, Mr. Dizon was responsible for the seismic verification program of safety-related mechanical and electrical systems and components. His tasks included developing seismic evaluation criteria and procedures for restart and long-term seismic programs; managing the seismic walkdown and evaluation efforts; providing technical support in resolving seismic issues; and serving as an interface with the client. Mr. Dizon was also responsible for the seismic walkdown and evaluation of various distribution systems and critical equipment at the Pantex Facilities, including developing the walkdown screening criteria and evaluation acceptance criteria.Mr. Dizon has participated in the seismic evaluation of the High Flux Isotope Reactor at Oak Ridge National Laboratory. This project involved performing seismic analyses and upgrades for the primary coolant piping system and related equipment, and the reactor and control buildings. Other DOE facilities he has involvement with included Los Alamos, Livermore and Hanford sites. Mr. Dizon has also been involved in a number of risk assessment programs for petrochemical plants and refineries, including seismic walkdowns at the 2 FACILITY RISK CONSULTANTS, Inc.Page 33 of 444 JOHN 0. DIZON, P.E.Imperial West Chemical plants in Pittsburg and Antioch, CA; Tosco Refinery in Avon, CA;and Dupont Chemical plant in Antioch, CA, among others.At EDAC, Mr. Dizon was responsible for the development and verification of a pipe support optimization program (OPTPIPE) and was involved in a number of snubber reduction pilot projects. Other areas of his involvement consisted of finite element analyses of the MX-missile launch tube components and systems for thermal and pressure loads, equipment qualification of major mechanical and electrical components, and seismic evaluation of cooling towers.With General Electric Company, Mr. Dizon was responsible for stress analysis and code conformation of main steam and recirculation piping systems for generic BWR plants. He was also involved in the developmental phase of an in-house pipe support optimization program.At URS/Blume & Associates, Mr. Dizon was responsible for the development and maintenance of in-house computer programs for both linear and nonlinear analyses of structural and piping systems. He was also involved in the linear and nonlinear dynamic analyses, finite element modeling, and generation of floor response spectra for several nuclear power plants. He helped develop a soil-structure interaction computer program using a three-dimensional finite element technique to evaluate the dynamic response of structures due to arbitrary plane body and surface wave excitations. He performed a research study involving soil-structure interaction analysis using the finite element FLUSH program to investigate the dynamic response of typical containment structures due to underground blast excitations. Mr. Dizon worked as a consultant to Bechtel Power Corporation with Structural Systems Engineering, Inc. He performed structural analyses and design assessments of the primary containment structure and the reactor/control buildings of several BWR plants for the various types of hydrodynamic loads. He was involved in a BWR in-plant test procedures, data reduction and correlation study to determine the dynamic response, including soil-structure interaction of the reactor/control buildings during GE Mark II reactor hydrodynamic load actuation in the primary containment. At Stanford University, Mr. Dizon performed statistical analyses of earthquake accelerograms and various response parameters, as part of his research work under Professor Haresh Shah. He also conducted seismic risk analyses and formulated seismic design criteria for Nicaragua. In addition, he was involved in the dynamic testing of structural models and equipment. EDUCATION STANFORD UNIVERSITY, Palo Alto, California: Engineer Degree, 1977 STANFORD UNIVERSITY, Palo Alto, California: M.S. Structural Engineering, 1975 MAPUA INSTITUTE OF TECHNOLOGY, Manila, Philippines: B.S. Civil Engineering, 1973 3 FACILITY RISK CONSULTANTS, Inc.Page 34 of 444 JOHN 0. DIZON, P.E.AFFILIATIONS AND AWARDS Multidisciplinary Center for Earthquake Engineering Research (MCEER), Strategic Partner Philippine Board Examination for Civil Engineers, Fifth Place, 1973 Philippine Association of Civil Engineers, Certificate of Merit, 1974 REGISTRATION California: Civil Engineer Philippines: Civil Engineer SELECTED PUBLICATIONS With S. J. Eder, 2007. "Seismic Qualification Case Study for a New Inverter." SMiRT-19 Conference, Toronto, Canada, August 12-17,2007. With S. J. Eder, 2006. "Use of Earthquake Experience Data for Seismic Qualification of Equipment. Prepared for Multidisciplinary Center for Earthquake Engineering Research (MCEER). June 22, 2006.With S. J. Eder, 2005. "Seismic Qualification Case Study." Prepared for Electric Power Research Institute and Seismic Qualification Utility Group. December 2005.With S. J. Eder, and R. D. Cutsinger. 2003. "Browns Ferry Cable Tray Evaluations." Presented to the SQUG/SEQUAL Annual Meeting, San Antonio, TX, December 10-12, 2003.With S. J. Eder. 2003. "Technical Position Paper for Seismic 11/I Design of Cable Tray Raceway Systems at PDCF." Presented to Washington Group, Inc., December 2003.With S. J. Eder, W. H. Tong, and E. H. Wong, 1999. "Chichi, Taiwan Earthquake of September 21, 1999 (M7.6). An EQE Briefing. Oakland, CA. October, 1999.With S. J. Eder. 1998. "Risk Management for Power and Industrial Facilities -- Focus on Business Interruption". Second Biennial Federation of Asian Pacific & African Risk Management Organization. Manila, Philippines. October, 1998.With F. R. Beigi. 1995. "Application of Seismic Experience Based Criteria for Safety Related HVAC Duct System Evaluation." Fifth DOE Natural Phenomena Hazards Mitigation Symposium, Denver, Colorado, November 13-14, 1995.With S. J. Eder, J. F. Glova, -and R. L. Koch. 1994. "Seismic Adequacy Verification of HVAC Duct Systems and Supports for an USI A-46 Nuclear Power Plant." Fifth Symposium on Current Issues Related to Nuclear Power Plant Structures, Equipment and Piping, Orlando, Florida, December 14-16, 1994.4 FACILITY RISK CONSULTANTS, Inc.Page 35 of 444 JOHN 0. DIZON, P.E.With E. J. Frevold and P. D. Osborne. 1993. "Seismic Qualification of Safety-related HVAC Duct Systems and Supports." ASME Pressure Vessel and Piping Division Conference, Denver, Colorado, July 1993.With S. J. Eder. 1991. "Advancement in Design Standards for Raceway Supports and Its Applicability to Piping Systems." ASME Pressure Vessel and Piping Division Conference, San Diego, California, June 1991.With R. D. Campbell and L. W. Tiong. 1990. "Response Predictions for Piping Systems Which Have Experienced Strong Motion Earthquakes." ASME Pressure Vessel and Piping Conference, Nashville, Tennessee, June 17-21, 1990.With S. P. Harris, R. S. Hashimoto, and R. L. Stover. 1989. "Seismic, High Wind, and Probabilistic Risk Assessments of the High Flux Isotope Reactor." Second DOE Natural Phenomena Hazards Mitigation Conference. With D. Ray and A. Kabir. 1979. "A 3-D Seismic Analysis for Arbitrary Plane Body and Surface Wave Excitations." American Society of Civil Engineers Nuclear Specialty Conference, Boston, Massachusetts. With D. Ray and A. Zebarjadian. 1978. "Dynamic Response of Surface and Embedded Disk Foundations for SH, SV, P and Rayleigh Wave Excitations." Sixth Indian Symposium on Earthquake Engineering, Roorkee, India."A Statistical Analysis of Earthquake Acclerograms and Response Parameters." 1977. Thesis, Stanford University, Palo Alto, California, With H. Shah, T. Zsutty, H. Krawinkler, and L. Padilla. 1977. "A Seismic Design Procedure for Nicaragua." Paper presented at the Sixth World Conference on Earthquake Engineering, New Delhi, India.With H. Shah, T. Zsutty, H. Krawinkler, C. P. Mortgat, and A. Kiremidjian. 1976. "A Study of Seismic Risk for Nicaragua, Part II, Summary and Commentary." John A. Blume Earthquake Engineering Center, Report No. 12A and 12B. Stanford University, Palo Alto, California. 5 FACILITY RISK CONSULTANTS, Inc.Page 36 of 444 STEPHEN J. EDER.PROFESSIONAL HISTORY Facilihy Risk Consultants, Huntsville, Alabama, Chief Executive Officer, 2003-present ABS Consulting, Houston, Texas, Vice President, North Asia Pacific Region, 2001-2003 EQE International, San Francisco, California, Senior Vice President, 1985-2001 (ABS Purchased EQE in 2000).URS/Join A. Blune & Associates, Engineers, San Francisco, California, 1982-1985 J. G. Bouwkamp, Inc., Structural Engineers, Berkeley, California, 1.981-1982 PROFESSIONAL EXPERIENCE Mr. Stephen J. Eder provides senior engineering and management consultant services, licensing support, and expert testimony in the fields of natural hazards risk assessment, seismic analysis, structural performance evaluation, and retrofit design. His background includes project management, engineering, risk management, and planning for domestic and multinational corporations, insurance and financial institutions, construction companies, utilities, and the government. Mr. Eder is based in Madison, Alabama.Prior to Facility Risk Consultants, Mr. Eder was stationed in Tokyo, Japan for 8 years and led all operations for ABS Consulting Inc. (formerly EQE International, Inc.) in Japan, China, Korea and Taiwan -- including risk consulting, structural engineering and design, probabilistic financial loss estimation, and the development and maintenance of management systems.Mr. Eder has performed many post-earthquake reconnaissance studies -- most notably he led investigations of the M8.4 earthquake in Arequipa, Peru of June 2001; the M7.6 earthquake in Chichi, Taiwan of September 1999; and he was lead investigator of the M8.1 earthquake in Mexico of September 1985, for the US Electrical Power Research Institute (EPRI).Prior to his assignment in Japan, Mr. Eder focused primarily in the seismic risk evaluation and seismic retrofit design of critical equipment and systems. Mr. Eder pioneered the development of many seismic risk evaluation procedures and criteria for the US and European nuclear power industry, the Seismic Qualification Utilities Group (SQUG), and the US Department of Energy (DOE). This included conducting a series of week-long seismic evaluation training courses for a total of about 500 engineers, and serving as subject matter expert and technical liason for industry groups.Mr. Eder served as project manager or project consultant for the seismic risk surveys of critical equipment and systems at about 60 nuclear power plants in the US and Europe, and many DOE facilities. He performed research for and supported many U.S. industry and professional groups, to advance the state-of-the-art of seismic risk assessment techniques and seismic design guidelines. 1 FACILITY RISK CONSULTANTS, Inc.Page 37 of 444 STEPHEN J. EDER EDUCATION UNIVERSITY OF CALIFORNIA, Berkeley: M.Eng., Structural Engineering and Structural Mechanics, 1982 CLARKSON COLLEGE OF TECHNOLOGY, Potsdam, New York: B.S., Magna Cum Laude, Civil and Environmental Engineering, 1980 REGISTRATION California: Civil Engineer, 1985 Alabama: Civil Engineer, 2003 PROFESSIONAL AND BUSINESS AFFILIATIONS American Society of Civil Engineers Earthquake Engineering Research Institute Structural Engineers Association of Northern California Applied Technology Council Tau Beta Pi National Engineering Honor Society Phi Kappa Phi National Honor Society American and British Chambers of Commerce in Japan COMMITTEES -- PAST EXPERIENCE -Electric Pozver Research Institute -Post Earthquake Investigation Team -Leader-U.S. Department of Energy -Tiger Team Member -Natural Hazards Risk Analysis-U.S. Department of Energy -Steering Committee on Natural Hazards -Technical Liason -Mechanical and Eletrical Equipment Evaluation and Design-Seismic Qualification Utility Group -Equipment Seismic Evaluation Training -Lead Instructor and Subject Matter Expert-Joint American Society of Mechanical Engineers and Institute of Electrical and Electronics Engineers -Special Seismic Qualification Working Group -CoChairman -National Centerfor Earthquake Engineering Research -Critical Equipment Seismic Risk Analysis -Chief Researcher -National Fire Protection Association (NFPA) -Seismic Technical Committee Member, NFPA-13.-Building Seismic Safety Council -Seismic Rehabilitation Advisory Panel Member -Mechanical Equipment. NEHRP, FEMA 273.-American Society of Civil Engineers -Electrical Raceway and HVAC Duct Seismic Design -Working Groups-Structural Engineers Association of California -Seismology Subcommittee -Non-Building Structures and Equipment 2 FACILITY RISK CONSULTANTS, Inc.Page 38 of 444 STEPHEN J. EDER SELECTED PUBLICATIONS & PRESENTATIONS With J. 0. Dizon, 2007. "Seismic Qualification Case Study for a New Inverter." SMiRT-19 Conference, Toronto, Canada, August 12-17, 2007.With J. 0. Dizon, 2006. "Use of. Earthquake Experience Data for Seismic Qualification of Equipment." Prepared for Multidisciplinary Center for Earthquake Engineering Research (MCEER). June 22, 2006.With J. 0. Dizon, 2005. "Seismic Qualification Case Study." Prepared for Electric Power Research Institute and Seismic Qualification Utility Group. December 2005.With J. 0. Dizon, and R. D. Cutsinger. 2003. " Browns Ferry Cable Tray Evaluations." Presented to the SQUG/SEQUAL Annual Meeting, San Antonio, TX, December 10-12, 2003.With J. 0. Dizon. 2003. " Technical Position Paper for Seismic II/I Design of Cable Tray Raceway Systems at PDCF." Presented to Washington Group, Inc., December 2003."Analysis of Ilo2 Plant Components Affected by the June 23, 2001 Mw 8.4 Arequipa, Peru Earthquake". Prepared for Hitachi Corporation. December 2002. Presented in London, U.K."The Use of Modeling and Natural Risk Analysis for Power Plants". Presented at Second International Conference on Mitigating Your Risks in Energy. February 2002. Singapore."Using Risk Based Inspection Techniques to Assess Maintenance of Power Plants". 2002.Presented at Second International Conference on Mitigating Your Risks in Energy. February 2002. Singapore."Preparing Your Properties for Major Earthquakes". 2001. Prepared for Architecture, Construction, and Engineering Subcomittee, American Chamber of Commerce in Japan.December 2001. Tokyo."Earthquake Hazards and Earthquake Risks in Tokyo". 2001. TELS-Setagaya, Earthquake Disaster Information and Preparedness Seminar. October 2001. Tokyo."Geographic Information Systems". 2000. Prepared for Non-Life Insurance Institute, ISJ Advanced Course 2000 Program, Natural Hazards and Underwriting Capacity. November 2000. Tokyo.With J. 0. Dizon, W. H. Tong, and E. R. Wong, 1999. "Chichi, Taiwan Earthquake of September 21, 1999 (M7.6). An EQE Briefing. Oakland, CA. October, 1999.With G.S. Johnson, R.E. Sheppard, M.D. Quilici, and C.R. Scawthorn, 1999. "Seismic Reliability Assessment of Critical Facilities: A Handbook, Supporting Documentation, and Model Code Provisions." Technical Report MCEER-99-0008. Multidisciplinary Center for Earthquake Engineering Research, Buffalo, NY."Earthquake Risk of Independent Power Producer Stations", 1999. Prepared for Lloyd's Japan Power Seminar. June 1999. Tokyo.3 FACILITY RISK CONSULTANTS, Inc.Page 39 of 444 STEPHEN J. EDER With J. 0. Dizon. "Risk Management for Power and Industrial Facilities -- Focus on Business Interruption". Second Biennial Federation of Asian Pacific & African Risk Management Organization. Manilla, Philippines. October, 1998."3 Years After the Hanshin-Kobe Earthquake, Earthquake Risk Management, Damage Assessment and Mitigation". 1998. High Pressure Gase Safety Association of Japan. Vol. 35, No. 2 (1998). Tokyo.With G. S. Johnson, R.E. Sheppard, and S.P. Harris. 1998. "A Method to Assess and Improve the Operational Reliability of Critical Systems Following Earthquakes." Presented at the 6th U.S. National Conference on Earthquake Engineering, Seattle, WA, June 1998.With G. S. Johnson, R.E. Sheppard, and S.P. Harris. 1998. "The Development of Model Code Provisions to Address System Reliability Following Earthquakes." Presented at the ATC-29-1 Seminar on Seismic Design, Retrofit, and Performance of Nonstructural Components, San Francisco, CA, January 1998.With D. W. Jones, M. K. Ravindra, C. R. Scawthorn, and K. lida. 1996. "Earthquake Risk Management for Process Industries". High Pressure Gas Safety Institute of Japan. Vol. 35, No.5 (1996). Tokyo.With G. A. Antaki. 1994. "Recommended Provisions for Equipment Seismic Qualification Consistent with IEEE and ASME Criteria for Use of Experience." ASME 1994, PVP-Vol. 275-2, Seismic Engineering, Volume 2.With P. J. Butler and R. P. Kassawara. 1994. "Application of the Generic Implementation Procedure Methodology to Demonstrate Seismic Adequacy of New and Replacement Equipment and Parts in USI A-46 Plants." ASME 1994, PVP-Vol. 275-2, Seismic Engineering -Volume 2. Proceedings American Power Conference, Illinois Institute of Technology, April 1994, Chicago, Illinois.With N. P. Smith and R. P. Kassawara. 1994. "Future Direction for the Use of Earthquake Experience Data." Proceedings American Power Conference, Illinois Institute of Technology, April 1994, Chicago, Illinois.With M. W. Eli and M. W. Salmon. November 1993. "Walkthrough Screening Evaluation Field Guide, Natural Phenomena Hazards at Department of Energy Facilities." UCRL-ID-115714, Revision 2. Lawrence Livermore National Laboratory."Seismic Design of Important Systems and Components--Functionality Considerations." 1993.Structural Engineers Association of Northern California, 1993 Fall Seminar, Nonstructural Components: Design and Detailing. San Francisco, California. With C. Scawthorn, M. Zadeh, and G. Johnson. 1993. "Economic Impacts of Earthquake Damage to Nonstructural Components." 40th North American Meetings of the Regional Sciences Association International, Houston, Texas.With M. W. Barlow, R. J. Budnitz, and M. W. Eli. 1993. "Use of Experience Data for DOE Seismic Evaluations." 4th DOE Natural Phenomena Hazards Mitigation Conference, Atlanta, Georgia.With K. Porter, G. S. Johnson, M. M. Zadeh, and C. Scawthorn. 1993. "Seismic Vulnerability of Equipment in Critical Facilities: Life-safety and Operational Consequences." Technical; Report NCEER-93-0022. National Center for Earthquake Engineering Research.4 FACILITY RISK CONSULTANTS, Inc.Page 40 of 444 STEPHEN J. EDER With J. K. Arros. 1993. "Applications of Experience-based Methods for Seismic Qualification of Distribution Systems." Prepared for Advanced Reactor Corporation FOAKE ALWR Seismic Qualification Project.With MPR Associates and Winston and Strawn. 1993. "Verifying the Seismic Adequacy of New and Replacement Equipment and Parts." Prepared for the SQUG Management Guidelines Document.With Lawrence Livermore National Laboratory. 1992. "Program Plan for the Evaluation of Systems and Components in Existing DOE Facilities Subject to Nataral Phenonema Hazards." Prepared for the U.S. Department of Energy.With J. 0. Dizon, P. D. Baughman, and G. S. Johnson. 1992. "Peer Review of the Watts Bar Nuclear Plant Integrated Interaction Program Suspended Systems Proximity Task." Prepared for Tennessee Valley Authority. With G. S. Hardy, G. S. Johnson, and R. W. Cushing of EQE; MPR; S&A; and URS. 1992."Walkdown Screening and Seismic Evaluation Training Course." Prepared for Seismic Qualification Utility Group.With M. W. Salmon. 1992. "Technical Safety Appraisal of the Idaho Chemical Processing Plant, NPH Discipline." Prepared for the U.S. Department of Energy.With M. W. Eli. 1992. "NPH Walkdown Evaluation Summary Report -Paducah Gaseous Diffusion Plant." Prepared for the U.S. Department of Energy.With G. S. Johnson, R. H. Kincaid, and G. S. Hardy. 1992. "High-rise Building Critical Equipment Study." Prepared for National Center for Earthquake Engineering Research.With K. E. Smith. 1992. "Seismic Performance of Standby and Emergency Power Engine Generator Systems." Prepared for National Center for Earthquake Engineering Research.With M. W. Eli. 1991. "Use of Earthquake Experience Data." Prepared for the Third DOE Natural Phenomena Hazards Mitigation Conference, St. Louis, Missouri.With J. 0. Dizon. 1991. "Advancement in Design Standards for Raceway Supports and Its Applicability to Piping systems." PVP-Volume 210-1, Codes and Standards and Applications for Design and Analysis of Pressure Vessel and Piping Components. ASME 1991."Cable Tray and Conduit System Seismic Evaluation Guidelines." March 1991. EPRI Report NP-7151. Prepared for the Electric Power Research Institute. San Francisco, CA: EQE International. With G. S. Johnson. March 1991. "The Performance of Raceway Systems in Strong-motion Earthquakes." EPRI Report NP-7150. Prepared for the Electric Power Research Institute. San Francisco, CA: EQE International. With G. S. Johnson. March 1991. "Longitudinal Load Resistance in Seismic Experience Data Base Raceway Systems." EPRI Report NP-7153. Prepared for the Electric Power Research Institute. San Francisco, CA: EQE International. With J. P. Conoscente and B. N. Sumodobila. March 1991. "Seismic Evaluation of Rod Hanger Supports for Electrical Raceway Systems." EPRI Report NP-7152. Prepared for the Electric Power Research Institute. San Francisco, CA: EQE International. 5 FACILITY RISK CONSULTANTS, Inc.Page 41. of 444 STEPHEN J. EDER With Winston & Strawn, MPR Associates, Inc., etal. June 1991. "Generic Implementation Procedure (GIP) for Seismic Verification of Nuclear Plant Equipment." Revision 2. Prepared for the Seismic Qualification Utility Group.With M. W. Eli and L. J. Bragagnolo. 1991. "Walkthrough Screening Evaluation Field Guide, Natural Phenomena Hazards at Department of Energy Facilities." Special Release for 3rd DOE Natural Phenomena Hazard Mitigation Conference, October 1991, St. Louis, Missouri.With L. J. Bragagnolo and J. P. Conoscente. 1990. "A Proposed Methodology for the Seismic Design of Rectangular Duct Systems." Applied Technology Center (ATC) Seminar on Seismic Design and Performance of Equipment and Nonstructural Elements in Building and Industrial Structures, Irvine, California. ATC-29.With J. J. Johnson and N. P. Smith. 1990. "Developments of the Seismic Qualification Utility Group." Applied Technology Center (ATC) Seminar on Seismic Design and Performance of Equipment and Nonstructural Elements in Building and Industrial Structures, Irvine, California. ATC-29.With W. Djordjevic, J. Eidinger, and F. Hettinger. 1990. "American Society of Civil Engineers Activities on Seismic Design of Electrical Raceways." Current Issues Related of Nuclear Power Plant Structures, Equipment, and Piping. Proceedings of the Third Symposium, Orlando, Florida, December 1990.With H. L. Williams. 1990. "Qualification of Cable Tray Supports by Earthquake Experience Data: Application at H. B. Robinson Plant" Current Issues Related of Nuclear Power Plant Structures, Equipment, and Piping. Proceedings of the Third Symposium, Orlando, Florida, December 1990.With R. P. Kennedy, J. D. Stevenson, J. J. Johnson, W. R. Schmidt, and K. Collins. June 1990."Watts Bar Civil Program Review." Prepared for Tennessee Valley Authority. With J. P. Conoscente, B. N. Sumodobila, and S. P. Harris. 1989. "Seismic Fatigue Evaluation of Rod Hung Systems." Prepared for the Tenth Conference on Structural Mechanics in Reactor Technology, (SMiRT).With P. D. Smith and J. P. Conoscente. December 1988. "SQUG Cable Tray and Conduit Evaluation Procedure." Paper presented at the Second Symposium on Current Issues Related to Nuclear Power Plant Structures, Equipment and Piping, Orlando, FL.With P. I. Yanev. 1988. "Evaluation of Cable Tray and Conduit Systems Using the Seismic Experience Data Base." Nuclear Engineering and Design (North-Holland, Amsterdam) 107: 149-153.With S. P. Harris, P. D. Smith, and J. E. Hoekendijk. October 1988. "Performance of Condensers and Main Steam Piping in Past Earthquakes." Report prepared for General Electric Nuclear Energy Boiling Water Reactor Owners Group. San Francisco: EQE Engineering. With J. J. Johnson, G. S. Hardy, N. G. Horstman, G. Rigamonti, M. R. Reyne, and D. R. Ketcham.August 1988. "Technical Basis, Procedures and Guidelines for Seismic Characterization of Savannah River Plant Reactors." E. I. Dupont De Nemours & Co, Aiken, South Carolina.6 FACILITY RISK CONSULTANTS, Inc.Page 42 of 444 STEPHEN J. EDER With S. P. Harris, P. S. Hashimoto, J. 0. Dizon, B. Sumodobila, G. M. Zaharoff, and L. J.Bragagnolo. March 1988. "Seismic Evaluation of the High Flux Isotope Reactor Primary Containment System." Report prepared for Martin Marietta Energy Systems, Inc. San Francisco: EQE Engineering. With S. W. Swan, "Summary of the Effects of the 1985 Mexico Earthquake to Power and Industrial Facilities." Proceedings of the American Society of Civil Engineers International Conference on the 1985 Mexico Earthquake, Factors Involved and Lessons Learned, Mexico City, Mexico, September 1986.With A. F. Kabir and S. Bolourchi, "Seismic Response of Pipes Supported on Complex Framing Systems." Proceedings of the American Society of Civil Engineers Structures Congress, New Orleans, Louisiana, September 1986.With S. W. Swan, "The Mexico Earthquake of September 19, 1985; Performance of Power and Industrial Facilities," Proceedings of the Third U. S. National Conference on Earthquake Engineering, Charleston, South Carolina, August 1986."Performance of Industrial Facilities in the Mexican Earthquake of September 19, 1985," Electric Power Research Institute Report No. NP-4605, Project 1707-30 Final Report, Palo Alto, California, June 1986, also presented at the IEEE Power Engineering Society Summer Meeting, Mexico City, Mexico, July 1986."Earthquake Response Analysis of a Braced Offshore Platform," University of California, Berkeley (June 1982), also American Petroleum Institute, October 1982, San Francisco, California. 7 Page 43 of 444 FACILITY RISK CONSULTANTS, Inc. L WorleyParsons James P. Edgar, P.E resources & energy Chief Civil/Structural Engineer Resume

SUMMARY

Project Manager with over 10 years of project retrofit, design, and management experience with WorleyParsons. Primary responsibilities included the project management, project engineering, and the overall structural engineering and design, coordination, and estimating for all types of retrofit and design projects. Tasks included structural steel design and inspection, engineering man-hour and material cost estimating, scheduling, and fabrication/erection technical support and construction field support. Responsibilities include performing as the engineering task lead for structural steel for multi-million dollar/large scale structural retrofit projects. In addition, tasks include managing the structural condition assessment services performed by the WorleyParsons' Chattanooga office.EXPERIENCE 2009 -Present Project Manager, WorleyParsons, Chattanooga, Tennessee Tennessee Valley Authority (TVA). Oversee multi-discipline projects. Responsibilities include development, management, and execution of the project scope, schedule and budget. Typical project responsibilities include management of several concurrent projects from proposal development, to the conceptual study phase, through design implementation, and construction support.2006 -2009 Principal Structural Engineer, WorleyParsons, Chattanooga, Tennessee Alstom ECSI Kansas City Power & Light (KCPL) -latan Generating Station Selective Catalytic Reduction (SCR) Project, Alstom Project Partnership. Task lead overseeing engineering and design of ductwork, new support structures and the reinforcement of the existing support structure to accommodate the SCR retrofit project. Responsibilities include originating and reviewing calculations for structural steel, ductwork, foundations and other miscellaneous structural projects associated with the SCR project. Responsible for overseeing other structural engineers and structural designers in order to facilitate the design drawings with respect to the budgeted man hours and schedule. Review and approval shop fabrication and detailed drawings for structural steel and ductwork. Facilitate all communications between the Chattanooga and Knoxville offices as well as provide estimating and scheduling for all current and future projects, optional design arrangements, and engineering studies. Conduct several site visits to determine the construction feasibility of present and future projects as well as to investigate and propose alternative arrangement options for the support of the SCR system.Alstom Performance Projects -Miscellaneous Projects. Task lead overseeing engineering and design of several miscellaneous structural steel, ductwork, and fossil projects. Responsibilities include originating and reviewing calculations for structural steel, ductwork, and other structural projects associated with fossil sites. Responsible for overseeing other structural engineers and structural designers in order to facilitate the design drawings with respect to the budgeted manhours and schedule. Projects include: Lamma Low NOx Ductwork Installation and Structural Steel Modifications Desota Low NOx Ductwork Installation Dominion Generation Chesterfield Station Furnace Buckstay Upgrade Study 2007 -Present Condition Assessment Services Team Leader, WorleyParsons, Chattanooga, Tennessee In addition to senior structural engineering activities, additional responsibilities include coordinating and leading condition assessment inspections at fossil power plants. The Chattanooga inspection 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 1 Rev 6 (03-Feb-09) Page 44 of 444 EcoNomics

  • WorleyParsons James P. Edgar, P.E resources

& energy Chief Civil/Structural Engineer Resume group consists of 16 civil/structural engineers who performed condition assessment inspections throughout the U.S. for several different utility companies. Coordinating responsibilities include estimating and scheduling manpower, developing a detailed inspection criteria, also evaluating and documenting the existing conditions of the respective component during the inspection. Post-inspection responsibilities include formalizing inspection findings, formulating necessary modifications and reinforcements, outlining future recommendations and inspection plans, reviewing the findings of team members, and executing any subsequent structural engineering tasks or engineering studies.Typical inspections include: Air and flue gas ductwork (internal and external)Circulating cooling water tunnels Coal handling bins, Chimneys and stacks, complete interior and exterior inspection Boiler internals and pressure vessels Furnace stiffening systems Miscellaneous structural systems at a typical fossil site Responsible Engineer, TVA Project Partnership Tennessee Valley Authority (TVA) -Project Partnership. Project lead overseeing multi-discipline projects. Responsibilities include role as the technical lead for the multi-discipline effort as well as the point of contact between all engineers, designers, vendors, suppliers, and TVA management. Tasks include technical review of engineering and design, perform documentation of modifications, monitor allocation and utilization of estimated budget, and presentation of design proposals, progress, and construction planning to plant and construction management. Projects include: Cumberland Fossil SCR Hopper and LPA Screen Installation and Existing Steel Modifications Multi-site TVA Chimney Structural Review and Reinforcement Project TVA Fossil Power Plants Condition Assessment Inspections CPS Energy -Braunig Peaker Project (Combustion Turbine). Responsibilities include the design of several new and retrofitted structures and new equipment foundations. Duties focus on designing the structural integrity, support measures, and serviceability of the new structures and foundations associated with the new combustion turbine project.2005 -2006 Structural Engineer, WorleyParsons, Chattanooga, Tennessee Progress Energy Carolinas (PGNC) -Roxboro Flue Gas Desulfurization (FGD). Responsibilities include the design of large ductwork and their support structures. Duties focus on designing the structural integrity, support measures, and thermal expansion characteristics for large ductwork associated with the new FGD system. In addition, responsibilities include designing the support steel and foundations for the FGD ductwork support structures. Progress Energy Carolinas (PGNC) -Mayo Flue Gas Desulfurization (FGD). In anticipation of future FGD project, conducted internal duct inspection for the Unit 1 ductwork at PGNC's Mayo plant site and provided report evaluating the condition of the ductwork and its structural components and recommending repairs.Alstom (Chattanooga) -TXU Oak Grove Hot Air Duct to Mills (New Boiler). Structural engineer for the design of the Hot Air Duct to the Mills for a new boiler construction project. Performed structural analysis of ductwork and support measures in addition to specifying metal expansion 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 2 Rev 6 (03-Feb-09) Page 45 of 444 EcoNomics

  • WorleyParsons James P. Edgar, P.E resources

& energy Chief Civil/Structural Engineer Resume joints. Provided subcontracted consulting engineering firm with ductwork-applied loading drawings to facilitate the structural steel and foundation design effort.TVA. Responsible for several miscellaneous structural engineering projects involving structural steel design, duct design and analysis and design of retaining wall structures for both fossil and hydro power plants. Other responsibilities included providing technical support and temporary structure design to help facilitate construction efforts during plant modification projects. In addition, responsibilities include internal structural inspections for circulating cooling water tunnel systems.2001 -2005 Structural Engineer, Alstom Power, Chattanooga, Tennessee East Kentucky Power -Spurlock No. 1, SCR Project. Responsibilities included the structural design of SCR ductwork, specification of fabric expansion joints, and slide gate and louver dampers.Provided subcontracted consulting engineering firm with ductwork-applied loading drawings to facilitate the structural steel and foundation design effort.Tucson Electric -Springerville Units I and 2 LowNOx Retrofit Project. Responsible for overall layout and design of ductwork, structural steel, SOFA, air registers, access platforms, and modifications to the existing ductwork. In addition, preformed structural analysis of existing support steel and provided details to reinforce the structure. Performed same responsiblities for projects with customers including Platte River, Lower River Colorado Authorities, TXU, PacificCorp, and Kentucky Utilities. Mobile Energy Service Corporation -Power Boiler No. 9, Furnace Explosion Rehabilitation Project. Structural engineer for the inspection of damaged boiler structural steel, access platforms, and furnace stiffeners. Produced inspection reports, design sketches, condition assessments, and material estimates to customer for required modifications/reinforcement and/or replacement of damaged steel.Dominion Generation -Chesterfield Unit 5, Secondary Air Duct Modifications. Structural engineer for the design of modifications to the secondary air duct stiffener framing, supports, and guides to accommodate the installation of new duct openings and new expansion joint placement. Specified new fabric expansion joints and provided detailed sketches for construction. Provided OEM with ductwork applied loading drawings to facilitate the structural steel and foundation design effort.Dominion Generation -Chesterfield No. 6, Ductwork and Furnace Upgrade Study. Conducted structural analysis of existing boiler framing and flue gas ductwork systems for FD/ID fan pressure upgrades. Additional responsibilities included, secondary site inspections to determine the construction sequencing and identify potential design changes of new ductwork/boiler framing modifications. Performed same responsiblities for projects with customers including TXU, Exelon, and Indianapolis Power and Light.Dominion Generation -Chesterfield No. 6, Ash Handling Tank Support Steel. Designed new support structure for an ash handling tank and equipment for the Economizer hopper. Evaluated the existing structural steel and provided detailed modifications to reinforce the existing structure effected by the new steel and equipment. EDUCATION B.S., Civil Engineering, University of Tennessee, Knoxville, Tennessee, 2001 Pursuing a Masters in Civil Engineering, University of Tennessee, Knoxville, Tennessee, 2003 -Present 002-O00-CPF-016 (007848) HRF-0033 Corporate Base Page 3 Rev 6 (03-Feb-09) Page 46 of 444 EcoNomics WorleyParsons James P. Edgar, P.E resources & energy Chief Civil/Structural Engineer Resume REGISTRATIONS/AFFILIATIONS Registered Professional Engineer -Tennessee, No.112009, 2008 One Way Element Leader, Element 9 Management of Change Member, AISC, ASCE Confined Space and Fall Protection Trained Member, STAAD User Group Wood Design CED Certified PUBLICATIONS/PRESENTATIONS ASCE Duct Design 2008 Structural Department Presentation Duct Inspection Procedures 2008 Structural Department Presentation Beam and Column Reinforcing Procedures 2008 Group Presentation ASCE Wind Design Structures and Ducts 2007 Group Presentation SCR Systems 2005 Structural Department Presentation SPECIFIC TECHNICAL EXPERTISE/SPECIALIST COURSES Doer-Seller Account Planning, 2010 Frontline Leadership Program, 2009 Prestressing Concrete (UTK) -Properties of prestressing materials; methods of pre-tensioning and post-tensioning; and analysis and design of simple and continuous beams and slabs Behavior of Steel Structures (UTK) -Focused on the design of beams, columns, beam-columns, connections, bracing, tension members, and the interpretation of the ASD and LRFD specifications. Statically Indeterminate Structures (UTC) -Analysis of frames, trusses, columns, and continuous beams by force methods and slope deflection. Analysis of Plates and Shells (UTC) -Bending and buckling of plates and shells and non-linear analysis of cables and cable roof structures. Computer Skills: STAADPro 2004 AutoCAD 2000, 2004 MicroStation Frameworks MathCAD Microsoft Office AWARDS Nominee for Eastern Operations People Development Award 2010 Eastern Operations Civil/Structural Engineer of the Year, 2008 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 4 Rev 6 (03-Feb-09) Page 47 of 444 EcoNomics WorleyParsons resources & energy Robert D. Malone, P.E.Structural Engineer Resume

SUMMARY

Structural Engineer with over seven years of experience with WorleyParsons in structural engineering. Tasks include analysis and design of flue gas desulfurization (FGD) and selective catalytic reduction (SCR) ductwork, support steel, foundations, minor/major modifications to existing structural steel/ductwork, and evaluations of existing steel. Design of miscellaneous steel/duct components including platforms, stair towers, turning vanes, and large particle ash (LPA) screens.Field experience includes ductwork inspections (miscellaneous ductwork, precipitators, economizers, SCRs) for damage/wear assessment and general inspection for pre-bid evaluation, condenser inspections, elevator shaft inspection, and site visits for steel/ductwork layout evaluations. Responsibilities include performing as lead for various projects, providing man-hour estimates, general project management, and task supervision of junior engineers. Additional experience includes approximately one year of nuclear experience in modular design of equipment support steel.EXPERIENCE 2005 -Present 2011 -Present 2011 -2012 Structural Engineer, WorleyParsons, Chattanooga, Tennessee Arizona Public Service (APS) -Cooling Tower Assessment. Provided structural assisgment of the existing cooling towers for the Redhawk, Cholla, Ocotillo, and West Phoenix power plants.General duties consisted of the following:

  • Performed structural inspections of both wooden and FRP cooling towers.o Performed "Repair vs. Replace" economic assessments.

I Provided inspection reports.American Electric Power (AEP) -Clifty Creek Power Plant, Unit Six SCR Addition. Provided structural assistance in the analysis of the existing unit six turbine and boiler build steel for increased loading caused by the addition of a new SCR mounted on top of the existing turbine building.General duties consisted of the following:

  • Modeled the existing turbine and boiler building., Designed the new SCR support steel located on top of the existing turbine building.Tennessee Valley Authority (TVA) -Kingston Steam Plant, Isolation Damper Project.Performed the structural analysis of the existing steel and ductwork for the additional equipment loadings related to the new isolation dampers and seal air fan additions to units one through nine.General duties consisted of the following:
  • Provided onsite support for construction.
  • Performed structural calculations for existing steel modifications., Provided support to the structural design team.TVA -Kingston Steam Plant, Steel Remediation.

Performed the structural analysis of existing steel damaged due to faulty orginal design. General duties consisted of the following: P Provided root cause analysis of the damaged duct support steel.* Provided structural calculations for the repair of the damaged duct support steel.Do Provided support to the structural design team.002-000-CPF-0 16 (007848) HRF-0033 Rev 6 (03-Feb-09) Corporate Base Page 48 of 444 Page 1 EcoNomics WorleyParsons Robert D. Malone, P.E.resources & energy Structural Engineer Resume TVA -Kingston Steam Plant, Condenser Cooling Water (CCW), Tunnel Inspections. Performed as task lead for the CCW tunnel inspections for units one though nine. General duties consisted of the follwing:* Performed CCW tunnel inspections.

  • Provided CCW tunnel assessment reports.P Scheduled and staffed the inspections.

2010 -2011 Westinghouse -Staff Augmentation at the Chattanooga, Tennessee Westinghouse Office.Provided structural engineering support for the design of nuclear equipment module support steel.General duties consisted of the following: P Performed structural analysis on modular units supporting equipment related to various AP1000 nuclear systems for loads induced by three boundary conditions: transportation, lifting, and operation. i Performed reviews/audits of calculations performed by Westinghouse employees as well as external contractors.

  • Provided assistance to design team to resolve/identify any constructability issues.i Performed calculation revisions resulting from design modifications.

h Provided technical guidance of junior engineers. 2010 Tennessee Valley Authority (TVA) -Allen Fossil Plant, EDTA Boiler Cleaning Project. Provided structural engineering required for the switchover from the present HCI acid cleaning system to a new forced circulation EDTA boiler cleaning system. General duties consisted of the following: P Provided pump foundation modification

  • Prepared pipe support design P Prepared platform modification
  • Provided man-hour estimates* Prepared assistance for the Task Work Scope document* Provided the structural portion of the project planning document P Attended site walkdowns for pipe routing and for meetings at the site 2007 -2010 Southern Company -Scherer Plant, Mercury Baghouse Project. General responsibilities consist of ductwork/steel layout and design, material takeoff, duct work and steel inspection, and general duties as a task lead. Tasks Include:* Requests for Information responses* Unit 2 existing steel modification for new ductwork P Unit 4 duct support steel layout/configuration
  • Unit 4 duct support steel design and management of design o Unit 4 ductwork layout P Unit 4 ductwork design and management of design* On-going construction support 2010 TVA -Colbert Fossil Plant, Reheat/Super Heat Attemperator Replacement.

Provided structural analysis of existing steel for the removal of the Unit 2 reheat attemperator and instalation of replacment reheat attemperator. Provided review of current monorail scheme already in place for Unit 3 super heat attemperator removal/replacement to assure it is suitable for all Units 1 through 4.General duties consist of the following:

  • Rigging design* Support steel reinforcement
  • Design drawing review P Plant personnel coordination 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 2 Rev 6 (03-Feb-09)

Page 49 of 444 EcoNomics

  • WorleyParsons Robert D. Malone, P.E.resources

& energy Structural Engineer Resume Site trip to identify field interferences TVA -Widows Creek Steam Plant, Ammonia Vaporizer Replacment. Provided rigging plan and supplementary steel for the ammonia vaporizer removal and installation. TVA -Shawnee Fossil Plant, Unit 8 Turbine Fire Inspection. Performed inspection of the turbine room roof, floor, and concrete turbine support frames. In addition to the above, also inspected the crane runway, girders, and rails in the immediate area of the fire. Provided structural repair recommendations. TVA -Kingston Steam Plant, Condensor Inspection. Performed inspection of the Unit 6 condensor. TVA requested the inspection after the plate wall failed during a leak test. To perform the leak test, the condenserwas filled with water. It is believed that after years of fatigue stress building up in the wall as well as poor craftsmanship, the additional hydrostatic pressure caused a horizontal fracture in the plate wall.TVA -Kingston Steam Plant, Condensor Inspection. Performed inspection of the Unit 5 condensor. A re-occurring crack in the side wall of the condensor caused pressure loss. Previous attempts by field personal to weld up the crack failed. Per TVA's request, a 3' x 5' section was cut out of the sidewall and replaced with a new plate.TA -Cumberland Fossil Plant, Boiler Tie Modification. Provided calculation review as well as engineering for the boiler tie modifications for the Unit 2 boiler. Also performed walkdown to insure that no interferences would be encountered. TVA -Cumberland Fossil Plant, Soot Blower Replacement Procedure Review. Per TVA's request, performed a safety evaluation of the current soot blower replacement procedure. This evaluation was spurred on by an accident in which a 60' blower lance fell from the 10th floor to the 8 th floor. Recommended modifcations to the platform layouts on floors 9, 10, and 11. These modifications mostly consisted of platform widening to allow larger turning radiuses for the 60' soot blowers.TVA -Cumberland Fossil Plant, Convection Pass Waterwall Replacement. Provided calculation review for the waterwall replacement, as well as a walkdown to insure that there would be no interferences for the construction procedures. 2009 -2010 TVA -Lagoon Creek Combined Cycle Plant. Providing services as the owner's engineer of the structural engineering portion for a steam turbine generator addition. Tasks Include: 0 Reviewing various calculations (turbine building steel and foundations, pipe racks, electrical buildings, steam turbine generator foundations, etc.).o- Peviewing various documents (drawings, bid analysis, vendor surveillance report, and technical specifications). 2009 Florida Power and Light -Putnam Plant. Provide structural input for a circulating water pipe upgrade proposal. Responsible for pipe support steel layout as well as steel estimate and pile estimate.TVA -SCR inspections projects include: op Cumberland Steam Plant -Provided condition assessment of the catalyst support beam connections. Provided immediate field repair recommendations. Responsible for guiding laborers in a manner that insured their safety as they performed their jobs. Responsible for daily updates on inspection progress to the customer.o Bull Run Steam Plant -Provided condition assessment of the catalyst support beam connections. 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 3 Rev 6 (03-Feb-09) Page 50 of 444 EcoNomics

  • WorleyParsons resources

& energy Robert D. Malone, P.E.Structural Engineer Resume 2008-2009 2008 2007-2008 TVA -Widows Creek Steam Plant. Inspection of the Unit 7 scrubber elevator shaft for condition assessment. Provided detailed report of the inspection. TVA -Cumberland Steam Plant, Limestone Scale Project. Provide structural engineering required for the conveyor modification for the installation of limestone scales. Provide strctural input at weekly meetings as well as provide input for design change notification preperation. Consumers Energy -D.E. Karn Fossil Plant, Pulse Jet Fabric Filter Project. General Responsibilities consisted of the following. o Analysis and design of the duct support structure for the return ducts 8, 9, 10A, 10B, and the supply ducts 4 and 5 for Unit 2 P- Pipe support steel for Unit 2Cable tray support steel for Unit 2* Platform design for Unit 2 Sunbury Generation LP -Sunbury Station Wet FGD Retrofit Project. Responsibilities consisted of the analysis and design of the limestone building as well as duct support structures. TVA -Cumberland Steam Plant LPA Screen Project. Performed the Phase 1 study, and performed duties as the task lead for the Phase 2 study. The study consisted of an LPA screen and hopper row addition in the SCR inlet ducts of Units 1 and 2. The addition of these components affected the existing ductwork as well as the support steel to the extent that rework of the structural bracing was required. Performed plant walkdowns for interface with screen vendor. Provided support for numerous update meetings as well as design review meetings at the plant with the TVA resident engineer. Responsible for man-hour estimates of the Phase 2 study.TVA -Kingston Fossil Plant Condenser Cooling Water Tunnel Inspection. Performed inspection of the inlet and discharge condenser cooling water tunnels.TVA -Cumberland Internal Duct Inspection Study. Conducted internal duct inspection for the Unit 1 ductwork, and provided report evaluating the condition of the ductwork and its structural components, and recommended repairs. The Cumberland inspection consists of the evaluation of the boiler outlet duct, SCR ductwork, and the precipitator box including its inlet and outlet duct trains.Nebraska Public Power District. Performed solo pre-bid general duct inspection and provided a report on the overall structural integrity of the existing ductwork.Alstom Power -Kansas City Power & Light, latan Generation Station. Performed design of SCR ductwork, existing steel modifications, existing steel/foundation evaluations for increased loads, pressure upgrade study for existing ductwork, and miscellaneous steel design (platforms, LPA screen). Other responsibilities included working with designers to convey engineering design and review of shop drawings. Attended walkdowns for interface with constructors. Progress Energy Carolinas (PGNC) -Roxboro FGD. Responsibilities included design of ductwork and related support structures, as well as furnishing calculation packages detailing the designs.Checked other engineers' calculations to ensure correctness. Other responsibilities included providing detailed sketches for designers, as well as checking finished drawings to insure correct structural configurations. Also provided support for plant walkdowns. Work included: Miscellaneous tasks included the design of various platforms, connections, base plates, anchor bolts, and stair towers.2007 2006-2007 2005-2006 002-000-CPF-016 (007848) HRF-0033 Rev 6 (03-Feb-09) Corporate Base Page 51 of 444 Page 4 EcoNomics

  • WorleyParsons resources

& energy Robert D. Malone, P.E.Structural Engineer Resume EDUCATION B.S., Civil Engineering, Emphasis in Structural, Tennessee Technological University, 2005 REGISTRATIONS/AFFILIATIONS Registered Professional Engineer -Pennsylvania, 2009 Engineer-in-Training -Tennessee, 2005 Member, Chi Epsilon Honor Society Member, Toastmasters, Club Number 1381870 Member, Kappa Alpha Order Member, American Institute of Steel Construction STAAD.Pro Committee Representative Chattanooga, Tennessee Office SPECIFIC TECHNICAL EXPERTISE/SPECIALIST COURSES Tennessee Valley Authority Responsible Engineer (R.E.) Training Program Computer Training: AutoCAD FORTRAN SmartPlant Review STAAD.Pro MathCAD MS Excel NavisWorks GTStrudl 002-uU0-CPF-01b (00748) HRF-0033 Rev 6 (03-Feb-09) Corporate Base Page 52 of 444 Page 5 EcoNomics David W. Moore 8701 Saint Johns Road Hixson, Tennessee 37343 (423) 842-0533 PROFESSIONAL

SUMMARY

Thirty-five years of nuclear power plant experience most at Sequoyah Nuclear Plant. During this tenure, have held positions as, Outage Management, Operations Assessor, Human Performance Manager, Operations Work Control Planning and Scheduling Manager, Shift Manager and various operator positions. PROFESSIONAL EXPERIENCE: 10/11 to Present- worked at Sequoyah Nuclear plant on TVA's Fukushima Japan response team focusing on Sequoyah site specific strategies and responses. 7/11 to 10/11- worked at Watts Bar Nuclear plant for the NEI 07 Groundwater Contamination (Tritium)environmental audit.4/11 to 6/11- worked at Sequoyah Nuclear plant for the NEI 07 Groundwater Contamination (Tritium)environmental audit.10/10 to 4/11- worked at Watts Bar Nuclear plant as a Developer for the Unit 1/Unit 2 startup and unit differences training for operators. 11/09 to 7/10- worked at Sequoyah Nuclear plant as a Developer for the Learning Material Upgrade Project for Operator Training.6/09 to 11/09- worked at Sequoyah Nuclear Plant Training Center as an instructor for Operator Training.12/08 to 5/09- worked at Prairie Island Nuclear plant as a developer for the Maintenance Rule Training Material.9/07 to 11/08- worked at Watts Bar Nuclear plant as a Developer for the Learning Material Upgrade Project for Operator Training.10/06 to 7/07- worked as mentor and operations manager at the Molten Salt Reactor in Oak Ridge Tennessee. 9/05- Retired in from Sequoyah Nuclear Plant 4/00 to 9/05 Sequoyah Nuclear Plant, Soddy-Daisy, TN Shift Manager Perform the duties of the Shift Manager. Ensure the safe operation of SQN under all conditions. During an emergency, duties include directing and controlling the actions of the operating crew and support personnel, as well as placing and maintaining the plant in a safe condition. During accident conditions serve as the Site Emergency Director until properly relieved. Serves as the Plant Manager whenever he is offsite to ensure the necessary management functions, protective actions and notifications are carried out.Completed the INPO Shift Managers training program at the INPO training facility.Served a lead assessor for Sequoyah Nuclear Plant switchyard and plant electrical system reliability. Served as a team member for the INPO mid-cycle operational readiness assessment at the Columbia Generating Station.Also served a team member for the operational readiness review for the Farley Generating Station.Page 53 of 444 Developed and implemented a Human Performance Coaching and training program for the operations department. Served as the Work Control Supervisor managing the work schedule, work priorities and plant critical evolutions. 1986 -2000 Sequoyah Nuclear Plant, Soddy-Daisy, TN Unit Supervisor Obtained and maintained a Senior Reactor Operators license since 1986. .Served as a Unit Supervisor for the Plant restart effort from 1984-1986. Responsible for the safe and reliable operation of the assigned unit and for compliance with Technical Specifications, operating license requirements, plant procedures, regulations and orders of the NRC Served as the refueling supervisor responsible for the refueling crew, maintenance group, engineering group and associated contractors. In direct charge of the operation of the assigned unit. Direct and supervise licensed and non licensed operators to ensure proper performance of their duties.. Exercise control over any action which could affect reactivity of the reactor..Have the authority to shutdown the unit or any equipment. if conditions warrant.- Authorize the removal and return to service of plant equipment.- Enforce control room conduct and activities.. Coordinate operation and surveillance testing of plant equipment and systems.. Coordinate tagging operations to include removal from service of all mechanical and electrical equipment.- Assumed the control room command function in the absence of the Shift Manager. -Had the responsibility for approval and review of all radwaste releases.1980- 1986 Sequoyah Nuclear Plant, Soddy-Daisy, TN Reactor Operator, As a reactor operator participated in unit start up to 100% power and criticality of the reactor.. Hot functional testing for the Unit 2 reactor and initial power ascension.. Obtained a Reactor operator license in 1981.1979-1980 Sequoyah Nuclear Plant, Soddy-Daisy, TN Assistant Unit Operator Participated in initial fuel loading.. Involved in low power physics testing for the initial start up.- Performed operations and alignments of plant systems during plant operation and startup testing.1977-1979 Sequoyah Nuclear Plant, Soddy-Daisy, TN Nuclear Student Generating Plant Operator, Completed a two year training program learning systems, procedures and theory of the nuclear industry.1974-1977 Gilman Paint and Varnish Chattanooga, TN.Chemical Technician, Responsible for sales, purchasing of inventory, store accounting and banking.1973-1974 Industrial Water Chemicals Chattanooga, TN.Chemical Technician Assisted in the development and the manufacture of chemicals.- Analyzed Boiler and heat exchanger water systems. Prescribed chemical treatment programs for industrial applications Assistant Store Manager EDUCATION 1968-1973 Tennessee Technological University Cookeville, TN BS Degree in Biology Interests Antique automobile restoration Page 54 of 444 i WorleyParsons S. Lance Summers, P.E.resources & energy Structural Engineer Resume

SUMMARY

Structural Engineer with over seven years of engineering experience, including four years with WorleyParsons. Primary responsibilities included the overall structural design and coordination for all types of power plant design and retrofit projects. Tasks included structural steel design, ductwork design, qualifying existing steel for upgraded loads/new code, foundation design, and providing erection/fabrication technical support for power generating stations. Skilled in creating and analyzing STAAD models for ductwork, structural steel, mat foundations, as well as creatively utilizing other software such as Excel, MathCAD, Smart Plant, and similar programs to expedite design. Also active in client interface with participation in project meetings and budget proposals. In addition, responsibilities include the inspection of ductwork, structural steel, and chimneys as part of the Chattanooga Condition Assesment Team. Familiar with AISC Steel Manual (ASD and LRFD), ACI 318-05, IBC 2000, and ASCE 7-05.EXPERIENCE 2009 -Present Structural Engineer, WorleyParsons, Chattanooga, Tennessee Tennessee Valley Authority (TVA) -Sequoyah Nuclear Power Plant, Soddy-Daisy, Tennessee. Qualification of new and existing nuclear fire protection pipe supports for new loading conditions, following appropriate design criteria, code provisions, and NRC requirements. Qualification and specification of both existing and new pipe support components, such as struts, clamps, and anchors.Qualification and design of non-standard welded connections. Pipe supports qualified using computer modeling, utilizing TVA supplied software. Software includes FAPPS (ME150), BASEPLATE II (ME035), MAPPS (ME153), CONAN, and lAP. Creation of supporting calculation packages utilizing MathCAD, Microsoft Excel and Word. Responsible for design input and verification of DCA (Drawing Change Authorization), which serves as the working document for required pipe support configurations and final support drawings to be issued into the TVA database.Tennessee Valley Authority (TVA) -Browns Ferry Nuclear Power Plant, Athens, Alabama.Qualification of existing nuclear pipe supports for new loading conditions associated with the replacement of motors on two minimum flow valves, following appropriate design criteria, code provisions, and NRC requirements. Qualification and specification of existing pipe support components, such as struts, clamps, and anchors. Qualification and design of non-standard welded connections. Pipe supports qualified using computer modeling, utilizing TVA supplied software.Software includes FAPPS (ME150), BASEPLATE II (ME035), MAPPS (ME153), CONAN, and lAP.Creation of supporting calculation packages utilizing MathCAD, Microsoft Excel and Word.Responsible for design input and verification of DCA (Drawing Change Authorization), which serves as the working document for required pipe support configurations and final support drawings to be issued into the TVA database.Tennessee Valley Authority (TVA) -Watts Bar Nuclear (WBN) Power Plant Unit 2, 1200 MW Unit, Spring City, Tennessee. Served as a team lead for a group of five engineers supporting the WBN Unit 2 pipe support project. Responsibilities include, but not limited to, the qualification of existing nuclear pipe supports for new loading conditions following the appropriate design criteria, code provisions, and NRC requirements. Qualification of existing and new pipe support components, such as snubbers, struts, clamps, and springs. Qualification and design of non-standard welded connections. The task utilized computer modeling via TVA-supplied software. The software includes FAPPS (ME150), BASEPLATE II (ME035), MAPPS (ME153), CONAN, and lAP. MathCAD, Excel, and Word. Software used in the creation of support calculation packages. Responsible for the review of Drawing Revision Authorization (DRA) to ensure accurate support drawings for issuance into the TVA database. Additional responsibilities included the review and verification of pipe support calculations prior to issuance and coordination between multiple offices to ensure quality, completeness, and consistency. 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 1 Rev 6 (03-Feb.09) Page 55 of 444EcoNomic WorleyParsons S. Lance Summers, P.E.resources & energy Structural Engineer Resume TVA -Widows Creek Fossil Unit 8 Opacity Reduction Study. Served as the structural task lead for a cost study of the addition of various air quality control measures (baghouse/precipitator) to Widows Creek Unit 8. The task included preliminary structural engineering of new ductwork, structural support steel, foundations, as well as the retrofit of the existing ductwork and structures. The work involved site visits to walkdown existing structures to find ways to interface with existing equipment and route ductwork through the existing structure. Interface with mechanical leads to provide the necessary ductwork cross-section and to ensure an efficient flow path to achieve a minimal pressure drop. Worked closely with the estimating department in order to produce an accurate cost estimate for four different retrofitting options.Southern Company -Scherer Unit 1-4, Flue Gas Desulphurization (FGD)/Selective Catalytic Reduction (SCR) Project, Juliet, Georgia. Responsible for the design of an electrical utility bridge for Units 1 and 2. The process included the layout of the utility bridge using SmartPlant Review and the design of the structure utilizing STAAD Pro. The task included the design of anchor bolts and the design of spread footings to support the structure. RC Cape May Holdings, LLC. -BL England Unit 2 Emissions Control Project, Beesley's Point, New Jersey. Primary responsibilities included the analysis and design of pile foundations to support the new SCR structure. The task included using SmartPlant Review to coordinate the layout of augercast piles in order to avoid existing interferences and obstructions. STAAD Pro 2007 finite element analysis used to analyze the pipe cap foundation. ACI 318-05 was utilized to provide the proper reinforcement for the pile cap as well as ensure that the anchor bolts met the requirements of Appendix D.2007 -2009 Structural Engineer Associate, WorleyParsons, Chattanooga, Tennessee CPS Peaking -Turbine Project, Braunig Plant, Texas. Primary responsibilities included the computer modeling, anlaysis, and design of soil supported mat foundations. Analysis and design of small equipment foundations including oil containment areas. Interfaced with the mechanical department in order to provide pipe supports and the associated foundations to support the chilled water and natural gas piping systems throughout the plant.Southern Company -Scherer Unit 1-4, FGD/SCR Project, Juliet, Georgia -Primary responsibilities included the retrofit of existing ductwork and support structures due to increased loading caused by an upgraded pressure load associated with the addition of a mercury baghouse, FGD, and SCR. STAAD used to analyze the ductwork and support structures while PCA Column and LPile were used to evaluate the existing caissons and piers. Retrofit modifications were made to qualify the structures for the increased shear, uplift, and compressive forces that were caused by the upgraded pressure.Mitsubishi Power Systems Americas -Termocandelaria, Simple Cycle Plant Dual Fuel Conversion, Cartegena, Colombia. Primary responsibilities included the computer modeling, analysis, and design of soil supported mat foundations. Analysis and design of small equipment foundations including oil containment areas. Provided pipe supports and foundations to assist mechanical/electrical engineers in the balance-of-plant design. Produced calculations for cast-in-place and post-installed equipment anchorage to concrete. Other duties included the design of concrete and masonry structures that were needed due to fire rating requirements. Work also included coordinating work with other disciplines to produce deliverables, providing project manager with regular updates, and producing estimates and NWIs for additional work added to the Structural Engineering Scope.Southern Company -Plant Scherer Unit 3 Mercury Baghouse, Juliet, Georgia. Primary responsibilities included performing the design and analysis of large ductwork and their support structures, as well as providing fabrication/erection support to the client. Other duties included creating and analyzing models for existing steel, ductwork, and working with designers to facilitate the generation of drawing deliverables, and meeting schedule requirements. 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 2 Rev 6 (03-Feb-09) Page 56 of 444 EcoNomics WorleyParsons resources & energy S. Lance Summers, P.E.Structural Engineer Resume Condition Assessment Services Team Member, WorleyParsons, Chattanooga, Tennessee In addition to structural engineering responsibilities, additional responsibilities include condition assessment inspections at fossil power plants. The tasks include traveling to the site and performing inspections, documenting the existing conditions of the respective component during the inspection, and providing a formalized post-inspection report which documents the findings and makes recommendations on any needed modifications to the structure. Typical inspections include air and flue gas ductwork, circulating cooling water tunnels, chimneys and stacks, and other miscellaneous structural systems.Project Engineer -C.W. Matthews Contracting Co., Marietta, Georgia 2004-2007 GDOT -McFarland RdISR 400 Interchange Project. Primary responsibilities included the design and implementation of erosion control plans, traffic control plans, and staging plans. In addition, responsibilities included working with Department of Transportation (DOT) representatives to alter/change plan design in order to account for situations in the field or in order to have a minimal impact of the traveling public. Responsibilities also included the coordination and scheduling of work and subcontractors. GDOT -SR20/SR400 Interchange Improvement Project. Primary responsibilities included the coordination and scheduling of work done by subcontractors and inspection of the work upon completion. In addition, responsibilities included working with DOT representatives to redesign plan in order to accommodate existing field conditions and to produce a more buildable design which was safer for the constructors as well as the traveling public. This included stormwater drainage plans, traffic control plans, and staging plans.EDUCATION B.S., Civil Engineering Technology, Southern Polytechnic State University, Marietta, Georgia, 2003.REGISTRATIONS/AFFILIATIONS Registered Professional Engineer, Civil, Pennsylvania, No. PE077046, 2009 Member, American Institute of Steel Construction (AISC)Confined Space and Fall Protection Trained SPECIFIC TECHNICAL EXPERTISE/SPECIALIST COURSES Computer Skills STAADPro V8i MathCAD LPile Plus 5.0 AutoCADSmartPlant Review SmartPlant Foundation Microsoft Office Applications PCA Column uut.VULM.,rr.v HO ~Uv, O~O~ nnr.vvoo ,~uIJuatU cabif Rev-600 -CPF-016 (0- -8)n Rev 6 (03-Feb-09) P5rp7raoe 4ase Page 57 of 444 rage o EcoNomics Glynna J Wilson Civil Design Engineer Sequoyah Nuclear Plant Tennessee Valley Authority

SUMMARY

Civil Engineer with 4.5 years of experience with the Tennessee Valley Authority.at Sequoyah Nuclear Plant. Experience includes designing structural modifications with plant system, equipment seismic qualification, design change field implementation, and other various roles of a Civil Engineer. Lead Civil Engineer on Maintenance Rule, Structural Monitoring, and Dam Governance. Also, the Site Snubber Program Engineer. Familiar with AISC Steel Construction Manual, ACI 318 Building Code, and ASCE 7 Minimum Design Loads for buildings and other structures. Proficient with current design software including AutoCAD and MathCAD.EXPERIENCE Tennessee Valley Authority-Served as a Civil Engineer within the Civil Engineering Design Group at Sequoyah Nuclear Plant since April 2008. Is qualified in Equipment Seismic Qualification and performed numerous evaluations of equipment during the procurement process. Responsible for field support for design change implementation. Familiar with the TVA CAP process and how it is used for problem identification and resolution. Qualified Civil Engineer in the Maintenance Rule Program responsible for maintaining structural condition of plant buildings and entering them into the CAP program and Maintenance Rule Tracking Calculation in order to monitor and drive resolution. Other responsibilities include field support, design change packages, verification of others work, and interface with other departments within and outside of the Engineering Organization. EDUCATION B.S., Civil Engineering, University of Tennessee at Chattanooga, Chattanooga, Tennessee, 2008 Page 58 of 444

  • WorleyParsons resources

& energy Phillip W. York, E.I.T.Structural Engineering Associate Resume

SUMMARY

Structural Engineering Associate with over three years of experience in the structural and civil engineering fields including pipe support systems analysis and structural design.EXPERIENCE 2010 -Present 2011 2008-2009 2007-2008 E Structural Engineering Associate, WorleyParsons, Chattanooga, Tennessee Tennessee Valley Authority (TVA) -Brown's Ferry Nuclear Power Plant, Athens, Alabama.Assisted in identifying and locating electrical panels and components for cable identification in all fire safety related systems.TVA -Watts Bar Nuclear Power Plant, Spring City, Tennessee. Conducted field walkdowns of piping layout and supports.TVA- Bellefonte Nuclear Power Plant, Hollywood, Alabama. Originated engineering analysis of pipe support systems including baseplates, structural steel, anchor bolts, welds, vendor components, and integral attachments. Civil Engineer, Atwell Group, Charleston, Tennessee Verified field accuracy and installation of storm sewers and sewer structures compared with designed drawings.Structural Engineer, March Adams & Associates, Chattanooga, Tennessee Assisted on structural design and site planning of engineering projects including a precast concrete bridge, apartment complexes, and various industrial sites.Dam Safety/River Operations Intern, TVA, Chattanooga, Tennessee Programmed proprietary database to accept decades of instrumentation data from hydroelectric plants and to calculate along predetermined parameters. EDUCATION B.S., Engineering (Civil Concentration), University of Tennessee, Chattanooga, Tennessee, 2008 REGISTRATIONSIAFFILIATIONS Engineer-in-Training, State of Tennessee, License #26776 SPECIFIC TECHNICAL EXPERTISE AutoCAD, 2D and 3D Drafting SolidWorks, 2D and 3D Drafting STAAD.Pro, Structural Analysis and Design RISA, 2D and 3D Structural Analysis 002-000-CPF-016 (007848) HRF-0033 Corporate Base Page 1 Rev 6 (03-Feb-09) Page 59 of 444 EcoNomics Appendix B: Base List 1 This Appendix includes the Sequoyah Unit 2 Base List 1..Page 60 of 444 Sequoyah Unit 2.UNID 0-ACCM-032-0060 0-ACCM-032-0086 O-AHU-311-0020 0-AHU-311-0023 O-AHU-311-0027 0-AHU-311-0028 O-BATB-250-QV 0-BATB-250-QW O-BATB-250-QX 0-BATB-250-QY O-BDG-250-KE O-BDG-250-KF O-BDG-250-KG 0-BDG-250-KH O-CHGB-250-QE O-CHGB-250-QF O-CHGB-250-QG O-CHGB-250-QH O-CHGB-250-QJ O-CHGB-250-QK 0-CHR-311-0126 0-CHR-311-0141 0-CHR-311-0156 O-CHR-311-0171 0-CHR-313-0303 0-CHR-313-0338 0-CLR-030-0192 0-CLR-030-0193 O-CLR-032-0065 0-CLR-032-0092 0-CMP-032-0060 0-CMP-032-0086 Base List 1 Description AUX CONTROL AIR ACC A AUX CONTROL AIR ACC B MAIN CONTROL ROOM AHU A-A MAIN CONTROL ROOM AHU B-B ELEC BOARD ROOM AHU A-A ELEC BOARD ROOM AHU B-B 125V DC VITAL BATTERY I 125V DC VITAL BATTERY II 125V DC VITAL BATTERY III 125V DC VITAL BATTERY IV 125V DC VITAL BATTERY BOARD I 125V DC VITAL BATTERY BOARD II 125V DC VITAL BATTERY BOARD III 125V DC VITAL BAT1ERY BOARD IV 125V DC VITAL BATTERY CHARGER I 125V DC VITAL BATTERY CHARGER 1-SPARE 125V DC VITAL BATTERY CHARGER II 125V DC VITAL BATTERY CHARGER III 125V DC VITAL BATTERY CHARGER IV 125V DC VITAL BATTERY CHARGER 2-SPARE MAIN CONTROL ROOM CHILLER PKG A-A MAIN CONTROL ROOM CHILLER PKG B-B ELEC BOARD ROOM CHILLER PKG A-A ELEC BOARD ROOM CHILLER PKG B-B SHUTDOWN BD ROOMS A&B CHILLER PKG A-A SHUTDOWN BD ROOMS A8B CHILLER PKG 8-8 SPENT FUEL PIT PMP & TB BOOSTER PMP RM COOLER A-A SPENT FUEL PIT PMP 8 TB BOOSTER PMP ROOM COOLER B-B AUX CONTROL AIR AFTERCOOLER A AUX CONTROL AIR AFTERCOOLER B AUX CONTROL AIR COMPRESSOR A-A AUX CONTROL AIR COMPRESSOR B-B Safety Function 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 5 0 0 0 0 Page 61 of 444 Sequoyah Unit 2 Base List 1 UNID Description Safety Function 0-CRN-303-SJ 0-DRYA-032-0074 O-DRYA-032-0075 O-DRYA-032-0099 0-DRYA-032-0100 0-FCV-070-0001 0-FCV-070-0011 0-FCV-070-0040 0-FCV-070-0041 0-FCV-070-0193 0-FCV-070-0194 0-FCV-070-0197 0-FCV-070-0198 0-FCV-070-0206 0-FCV-070-0208 0-FLT-032-0074 0-FLT-032-0075 0-FLT-032-0082 0-FLT-032-0085 0-FSV-311-0022A 0-FSV-311-0022B 0-FSV-311-0039A 0-FSV-311-0039B 0-FSV-311-0041A 0-FSV-311-0041B 0-FSV-311-0043A 0-FSV-311-0043B 0-HEX-070-0012A 0-HEX-070-0012B 0-HEX-077-0096 0-HEX-077-0111 0-HEX-078-0017 125 TON AUX BLDG CRANE AUX BLDG AIR DRYER (NO 1) A-A AUX BLDG AIR DRYER (NO 2) A-A AUX BLDG AIR DRYER (NO 2) B-B AUX BLDG AIR DRYER (NO 1) B-B SFPCS HTX B OUTLET VLV SFPCS HTX A OUTLET VLV SFPCS HTX B INLET VLV SFPCS HTX A INLET VLV SFPCS HTX SUPPLY HEADER VLV SFPCS HTX SUPPLY HEADER VLV SFPCS HTX SUPPLY HEADER VLV SFPCS HTX SUPPLY HEADER VLV COND DEMIN WASTE EVAL BLDF RETURN ISOL VLV COND DEMIN WASTE EVAL BLDF SUPPLY ISOL VLV AUX CONRTOL AIR COMPRESSOR A-A PREFILTER AUX CONRTOL AIR COMPRESSOR B-B PREFILTER CONTROL AIR AFTERFILTER TO DRYERS A-A CONTROL AIR AFTERFILTER TO DRYERS B-B MAIN CONT RM AHU A-A TEMP MAIN CONT RM AHU A-A TEMP MAIN CONT RM AHU B-B TEMP MAIN CONT RM AHU B-B TEMP ELECTRICAL BD RM AHU B-B TEMP ELECTRICAL BD RM AHU B-B TEMP ELECTRICAL BD RM AHU B-B TEMP ELECTRICAL BD RM AHU B-B TEMP COMPONENT COOLING HX 0B1 COMPONENT COOLING HX 0B2 WASTE GAS COMPRESSOR A HEAT EXCHANGER WASTE GAS COMPRESSOR B HEAT EXCHANGER SPENT FUEL PIT HEAT EXCHANGER B Page 62 of 444 Sequoyah Unit 2 UNID 0-HEX-078-0018 O-LS-018-0062A/1 O-LS-018-0062A/2 O-LS-018-0062A/3 O-LS-018-0062A/4 O-LS-018-0062B/1 O-LS-018-0062B/2 O-LS-018-0062B/3 0-LS-018-0062B/4 O-LS-018-0078A/1 O-LS-018-0078A/2 O-LS-018-0078A/3 O-LS-018-0078A/4 O-LS-018-0078B/1 O-LS-018-0078B/2 0-LS-018-0078B/3 O-LS-018-0078B/4 O-PMP-067-0432 0-PM P-067-0436 0-PMP-067-0440 O-PMP-067-0444 0-PMP-067-0452 O-PMP-067-0456 O-PMP-067-0460 O-PMP-067-0464 O-PM P-067-0470 O-PM P-067-0477 O-PMP-067-0482 O-PMP-067-0487 0-PMP-070-0051 0-PMP-313-0303 O-PMP-313-0338 Base List 1 Description SPENT FUEL PIT HEAT EXCHANGER A DSL GENERATOR DAY TANK 1 LEVEL-LOW DSL GENERATOR DAY TANK 1 LEVEL-LOW DSL GENERATOR DAY TANK 1 LEVEL-LOW DSL GENERATOR DAY TANK 1 LEVEL-LOW DSL GENERATOR DAY TANK 1 LEVEL-HI DSL GENERATOR DAY TANK 1 LEVEL-HI DSL GENERATOR DAY TANK 1 LEVEL-HI DSL GENERATOR DAY TANK 1 LEVEL-HI DSL GENERATOR DAY TANK 2 LEVEL-LOW DSL GENERATOR DAY TANK 2 LEVEL-LOW DSL GENERATOR DAY TANK 2 LEVEL-LOW DSL GENERATOR DAY TANK 2 LEVEL-LOW DSL GENERATOR DAY TANK 2 LEVEL-HI DSL GENERATOR DAY TANK 2 LEVEL-HI DSL GENERATOR DAY TANK 2 LEVEL-HI DSL GENERATOR DAY TANK 2 LEVEL-HI ERCW PUMP J-A ERCW PUMP K-A ERCW PUMP L-B ERCW PUMP M-B ERCW PUMP N-B ERCW PUMP P-B ERCW PUMP Q-A ERCW PUMP R-A ERCW SCREEN WASH PUMP A-A ERCW SCREEN WASH PUMP B-B ERCW SCREEN WASH PUMP C-B ERCW SCREEN WASH PUMP D-A CCS PUMP C-S SHTDN BD RM A&B CW SYS CIRC PMP SHTDN BD RM A&B CW SYS CIRC PMP Safety Function 0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 63 of 444 Sequoyah Unit 2 UNID 0-SGEN-311-0053 0-SGEN-311-0062 0-TCV-067-0195 0-TCV-067-0197

  • 0-TCV-067-0199 0-TCV-067-0201 0-TN K-018-5032-1A1 0-TNK-018-5032-1A2 0-TN K-018-5032-1A3 0-TNK-018-5032-1A4 0-TNK-018-5032-1B1 0-TNK-018-5032-1B2 0-TN K-018-5032-1B3 0-TN K-018-5032-1B4 0-TNK-018-5032-2A1 0-TNK-018-5032-2A2 0-TNK-018-5032-2A3 0-TNK-018-5032-2A4 0-TNK-018-5032-2B1 0-TNK-018-5032-2B2 0-TN K-018-5032-2B3 0-TNK-018-5032-2B4 0-TNK-032-0062 0-TNK-032-0088 2-AHU-030-0080 2-AHU-030-0083 2-AHU-030-0088 2-AHU-030-0092 2-AHU-313-0262 2-AHU-313-0267 2-AHU-313-0332 2-AHU-313-0367 Base List 1 Description MAIN CONT RM AHU A-A STEAM GEN ELECT BD RM AHU A-A STEAM GEN ELECT RM A/C COND A SUPPLY CNTL VLV CONT BLDG A/C COND A SUPPLY CNTL VLV ELECT RM A/C COND B SUPPLY CNTL VLV CONT BLDG A/C COND B SUPPLY CNTL VLV HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK HORIZONTAL DSL FUEL OIL STG TNK AUX CONTROL AIR RECVR A-A AUX CONTROL AIR RECVR B-B CONTROL ROD DRIVE COOLING UNIT D-B CONTROL ROD DRIVE COOLING UNIT A-A CONTROL ROD DRIVE COOLING UNIT C-A CONTROL ROD DRIVE COOLING UNIT B-B INCORE INST RM AHU A INCORE INST RM AHU B SHTDN BD RM B SUPPLY AHU 2A-A SHTDN BD RM B SUPPLY AHU 2B-B Safety Function 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 5 5 5 0 0 0 0 Page 64 of 444 Sequoyah Unit 2 UNID 2-AHU-313-0488 2-AHU-313-0514 2-BATB-082-UD 2-BATB-082-UE 2-BDA-202-CO 2-BDB-201-DN 2-BDB-201-DO 2-BDB-201-DP 2-BDB-201-DQ 2-BDB-202-CP 2-BDC-201-FL 2-BDC-201-FN 2-BDC-201-FQ 2-BDC-201-FR 2-BDC-201-FU 2-BDC-201-FV 2-BDC-201-GL 2-BDC-201-GM 2-BDC-201-GN 2-BDC-201-GO 2-BDC-201-JJ 2-BDC-201-JK 2-BDC-201-JL 2-BDC-201-JM 2-BDC-201-JP 2-BDC-201-JQ 2-BDE-250-ND 2-BDE-250-NF 2-BDE-250-NH 2-BDE-250-NK 2-CHG B-062-TZ 2-CHGB-062-UA Base List 1 Description 480V BD RM 2A SUPPLY AHU 2A-A 480V BD RM 2B SUPPLY AHU 2B-B DG 2A-A BATTERY DB 2B-B BATTERY 6900V SHUTDOWN BOARD 2A-A 480V SHUTDOWN BD 2A1-A 480V SHUTDOWN BD 2A2-A 480V SHUTDOWN BD 2B1-B 480V SHUTDOWN BD 2B2-B 6900V SHUTDOWN BOARD 2B-B 480V ERCW MCC 2A-A 480V ERCW MCC 2B-B 480V DIESEL AUXILIARY BOARD 2A1-A'480V DIESEL AUXILIARY BOARD 2A2-A 480V DIESEL AUXILIARY BOARD 2B1-B 480V DIESEL AUXILIARY BOARD 2B2-B 480V REACTOR MOV BOARD 2A1-A 480V REACTOR MOV BOARD 2A2-A 480V REACTOR MOV BOARD 2B1-B 480V REACTOR MOV BOARD 2B2-B 480V CONTROL & AUX BLDG VENT BOARD 2A1-A 480V CONTROL & AUX BLDG VENT BOARD 2A2-A 480V CONTROL & AUX BLDG VENT BOARD 2B1-B 480V CONTROL & AUX BLDG VENT BOARD 2B2-B 480V REACTOR VENT BOARD 2A-A 480V REACTOR VENT BOARD 2B-B 120V AC VITAL INST POWER BOARD 2-1 120V AC VITAL INST POWER BOARD 2-11 120V AC VITAL INST POWER BOARD 2-111 120V AC VITAL INST POWER BOARD 2-IV DG 2A-A BATTERY CHARGER DG 2B-B BATTERY CHARGER Safety Function 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 65 of 444 Sequoyah Unit 2 UNID 2-CHR-043-0156 2-CHR-313-0221A 2-CHR-313-0228A 2-CLR-030-0074 2-CLR-030-0075 2-CLR-030-0077 2-CLR-030-0078 2-CLR-030-0095 2-CLR-030-0097 2-CLR-030-0099 2-CLR-030-0100 2-CLR-030-0175 2-CLR-030-0176 2-CLR-030-0177 2-CLR-030-0178 2-CLR-030-0179 2-CLR-030-0180 2-CLR-030-0181 2-CLR-030-0182 2-CLR-030-0183 2-CLR-030-0184 2-CLR-030-0185 2-CLR-030-0186 2-CLR-030-0187 2-CLR-030-0194 2-CLR-030-0195 2-CLR-030-0196 2-CLR-030-0197 2-CLR-030-0201 2-CLR-030-0202 2-CLR-043-0331A 2-CLR-043-0331B Base List 1 Description HOT SAMPLE ROOM CHILLER INCORE INST RMWTR CHILLER PKG A INCORE INST RMWTR CHILLER PKG B LOWER COMPT COOLING UNIT A-A LOWER COMPT COOLING UNIT C-A LOWER COMPT COOLING UNIT B-B LOWER COMPT COOLING UNIT D-B UPPER COMPT COOLING UNIT A UPPER COMPT COOLING UNIT B UPPER COMPT COOLING UNIT C UPPER COMPT COOLING UNIT D RHR PUMP RM COOLER 2A-A RHR PUMP RM COOLER 2B-B CONTAINMENT SPRAY PUMP RM COOLER 2A-A CONTAINMENT SPRAY PUMP RM COOLER 2B-B SIS PUMP RM COOLER 2B-B SIS PUMP RM COOLER 2A-A RECIP CHG PMP RM COOLER 2C-B CENTRIF CHARGING PUMP RM COOLER 2B-B CENTRIF CHARGING PUMP RM COOLER 2A-A BA XFER PMP & AUX FW PMP SP CLR A-A BA XFER PMP & AUX FW PMP SP CLR B-B PENETRATION ROOM COOLER 2A-A PENETRATION ROOM COOLER 2B-B PENETRATION ROOM COOLER 2A-A PENETRATION ROOM COOLER 2B-B PENETRATION ROOM COOLER 2A-A PENETRATION ROOM COOLER 2B-B PIPE CHASE COOLER 2A-A PIPE CHASE COOLER 2B-B POST ACCIDENT SAMPLING COOLERS 1 POST ACCIDENT SAMPLING COOLERS 2 Safety Function 5 0 0 5 5 5 5 5 5 5 5 5 5 5 5 5 5 0 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page 66 of 444 Sequoyah Unit 2 UNID 2-CLR-062-0191 2-CMP-082-0240 2-CMP-082-0241 2-CMP-082-0270 2-CMP-082-0271 2-CMP-313-0483 2-CMP-313-0508 2-CND-062-0192 2-CND-062-0196 2-CND-313-2074 2-CND-313-2075 2-CRN-303-DQ 2-ENG-082-0002A1 2-ENG-082-0002A2 2-ENG-082-0002B1 2-ENG-082-0002B2 2-FAN-030-0038 2-FAN-030-0039 2-FAN-030-0246A 2-FAN-030-0246B 2-FAN-030-0246D 2-FAN-030-0246E 2-FAN-030-0250A 2-FAN-030-0250B 2-FAN-030-0316 2-FAN-030-0317 2-FAN-030-0448 2-FAN-030-0450 2-FAN-030-0452 2-FAN-030-0454 2-FAN-030-0456 2-FAN-030-0458 Base List 1 Description BORIC ACID EVAP PKG B DISTILLATE COOLER DSL 2A1 STARTING AIR COMPRESSER 25.5 CFM DSL 2A2 STARTING AIR COMPRESSER 25.5 CFM DSL 2B1 STARTING AIR COMPRESSER 25.5 CFM DSL 2B2 STARTING AIR COMPRESSER 25.5 CFM 480V ELECT BD RM 2A AIR RECIP COMP 2A-A 480V ELECT BD RM 2B AIR RECIP COMP 2B-B BORIC ACID EVAP PKG B CONDENSER BORIC ACID EVAP PKG B VENT CONDENSER 480V ELECT BD RM 2A AIR COOLED COND 2A-A 480V ELECT BD RM 2B AIR COOLED COND 2B-B 175 TON POLAR CRANE DIESEL ENGINE 2A1 DIESEL ENGINE 2A2 DIESEL ENGINE 2B1 DIESEL ENGINE 2B2 CNTMT AIR RETURN FAN A CNTMT AIR RETURN FAN B 480V TRANSFORMER ROOM 2B EXH FAN 2B1-A 480V TRANSFORMER ROOM 2B EXH FAN 2B2-A 480V TRANSFORMER ROOM 2B EXH FAN 2B3-A 480V TRANSFORMER ROOM 2B EXH FAN 2B4-A 480V TRANSFORMER ROOM 2A EXH FAN 2A1-B 480V TRANSFORMER ROOM 2A EXH FAN 2A2-B DIESEL PANEL 2A-A VENT FAN DIESEL PANEL 2B-B VENT FAN D-G RM 2A-A EXHAUST FAN 1 D-G RM 2B-B EXHAUST FAN 1 D-G RM 2A-A EXHAUST FAN 2 D-G RM 2B-B EXHAUST FAN 2 DIESEL GEN ROOM 2A-A BATTERY HOOD EXHAUST DIESEL GEN ROOM 2B-B BATTERY HOOD EXHAUST Safety Function 3,5 0 0 0 0 0 0 3,5 3,5 0 0 0 0 0 0 0 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page 67 of 444 Sequoyah Unit 2 UNID 2-FAN-030-0460 2-FAN-030-0462 2-FAN-030-250D 2-FAN-313-0496 2-FAN-313-0497 2-FAN-313-0522 2-FAN-313-0523 2-FCO-030-0250B 2-FCO-030-246A 2-FCO-030-246B 2-FCO-030-250A 2-FCO-313-0478A 2-FCO-313-0478B 2-FCO-313-0496 2-FCO-313-0497 2-FCO-313-0498 2-FCO-313-0499 2-FCO-313-0503 2-FCO-313-0510 2-FCO-313-0522 2-FCO-313-0523 2-FCO-313-0524 2-FCV-001-0004 2-FCV-001-0007 2-FCV-001-0011 2-FCV-001-0014 2-FCV-001-0015 2-FCV-001-0016 2-FCV-001-0022 2-FCV-001-0025 2-FCV-001-0029 2-FCV-001-0032 Base List 1 Description DIESEL GEN 2A-A ELECT BD ROOM EXHAUST DIESEL GEN 2B-B ELECT BD ROOM EXHAUST 480V TRANSFORMER ROOM 2A EXH FAN 2A3-B BATTERY ROOM IV EXHAUST FAN 2B1-A BATTERY ROOM IV EXHAUST FAN 2B2-B BATTERY ROOM III EXHAUST FAN 2A1-A BATTERY ROOM III EXHAUST FAN 2A2-B TRANSFORMER ROOM 2A DAMPER TRANSFORMER ROOM 2B DAMPER TRANSFORMER ROOM 2B DAMPER TRANSFORMER ROOM 2A DAMPER BOARD RM CONDENSER 2A-A DAMPER BOARD RM CONDENSER 2A-A DAMPER BATTERY ROOM IV DAMPER FOR FAN Al-A BATTERY ROOM IV DAMPER FOR FAN A2-B BATTERY ROOM IV DAMPER FOR FAN A2-B BATTERY ROOM IV DAMPER FOR FAN Al-A BOARD RM CONDENSER 2B-B DAMPER BATTERY ROOM III DAMPER FOR FAN B2-B BATTERY ROOM III DAMPER FOR FAN Bl-A BATTERY ROOM III DAMPER FOR FAN B2-B BATTERY ROOM III DAMPER FOR FAN Bl-A SG 1 MAIN STM HDR ISOLATION VALVE BLOWDOWN FLOW CONTROL VLV, SG-l SG 2 MAIN STM HDR ISOLATION VALVE BLOWDOWN HDR FLOW CONTROL VLV, SG-2 AUX FW PMP TURB STM SUPPLY FROM SG NO 1 AUX FW PMP TURB STM SUPPLY FROM SG NO 4 SG 3 MAIN STM HDR ISOLATION VALVE BLOWDOWN HDR FLOW CONTROL VLV, SG-3 SG 4 MAIN STM HDR ISOLATION VALVE BLOWDOWN HDR FLOW CONTROL VLV. SG-4 Safety Function 5 5 5 0 0 0 0 5 5 5 5 0 0 0 0 0 0.0 0 0 0 0 5 5 5 5 4,5 4,5 5 5 5 5 Page 68 of 444 Sequoyah Unit 2 UNID 2-FCV-001-01BI 2-FCV-001-01B2 2-FCV-001-01B3 2-FCV-001-01B4 2-FCV-003-0033 2-FCV-003-0047 2-FCV-003-0087 2-FCV-003-0100 2-FCV-003-0126A 2-FCV-003-0136A 2-FCV-003-0166A 2-FCV-003-0166B 2-FCV-003-0179A 2-FCV-003-0179A 2-FCV-026-0240 2-FCV-026-0243 2-FCV-030-0007 2-FCV-030-0008 2-FCV-030-0009 2-FCV-030-0010 2-FCV-030-0014 2-FCV-030-0015 2-FCV-030-0016 2-FCV-030-0017 2-FCV-030-0019 2-FCV-030-0020 2-FCV-030-0037 2-FCV-030-0040 2-FCV-030-0047 2-FCV-030-0048 2-FCV-030-0050 2-FCV-030-0051 Base List 1 Description Safety Function BLOWDOWN ISOL VLV INSIDE CNTMT, SG-1 BLOWDOWN ISOL VLV INSIDE CNTMT, SG-2 BLOWDOWN ISOL VLV INSIDE CNTMT, SG-3 BLOWDOWN ISOL VLV INSIDE CNTMT, SG-4 SG#1 FW ISOLATION VALVE STM GEN #2 ISOLATION VALVE STM GEN #3 ISOLATION VALVE STM GEN #4 FW ISOLATION VALVE ERCW HDR B ISOL VLV ERCW HDR A ISOL VLV ERCW HDR A ISOL VLV ERCW HDR A ISOL VLV ERCW HDR B ISOL VLV ERCW HDR B ISOL VLV CONTAINMENT STAND PIPE REACTOR COOLANT PMP SPRAY ISOL VLV UPPER COMPT PURGE ISOLATION VALVE UPPER COMPT PURGE ISOLATION VALVE UPPER COMPT PURGE ISOLATION VALVE UPPER COMPT PURGE ISOLATION VALVE LOWER COMPT PURGE ISOLATION VALVE LOWER COMPT PURGE ISOLATION VALVE LOWER COMPT PURGE ISOLATION VALVE LOWER COMPT PURGE ISOLATION VALVE INCORE INSTR ROOM PURGE ISOLATION VALVE INCORE INSTR ROOM PURGE ISOLATION VALVE LOWER COMPT PURGE CTRL VALVE LOWER COMPT PURGE CTRL VALVE CONTAINMENT VACUUM RELIEF CONTAINMENT VACUUM RELIEF.UPPER CNTMT EXH ISOLATION VALVE UPPER CNTMT EXH ISOLATION VALVE Page 69 of 444 Sequoyah Unit 2 Base List 1 UNID Description 2-FCV-030-0052 2-FCV-030-0053 2-FCV-030-0056 2-FCV-030-0057 2-FCV-030-0058 2-FCV-030-0059 2-FCV-032-0081 2-FCV-032-0103 2-FCV-032-0111 2-FCV-061-0096 2-FCV-061-0097 2-FCV-061-0110 2-FCV-061-0122 2-FCV-061-0191 2-FCV-061-0192 2-FCV-061-0193 2-FCV-061-0194 2-FCV-062-0009 2-FCV-062-0022 2-FCV-062-0035 2-FCV-062-0048 2-FCV-062-0061 2-FCV-062-0063 2-FCV-062-0069 2-FCV-062-0070 2-FCV-062-0072 2-FCV-062-0073 2-FCV-062-0074 2-FCV-062-0077 2-FCV-062-0085 2-FCV-063-O001 2-FCV-063-0003 UPPER CNTMT EXH ISOLATION VALVE UPPER CNTMT EXH ISOLATION VALVE LOWER CNTMT EXH ISOLATION VALVE LOWER CNTMT EXH ISOLATION VALVE INCORE INSTR ROOM EXH ISOLATION VALVE INCORE INSTR ROOM EXH ISOLATION VALVE REACTOR BLDG UNIT 2 TRAIN A ISOL VLV REACTOR BLDG UNIT 2 TRAIN B ISOL VLV REACTOR BLDG UNIT 2 NONESNTL CNTL AIR ISOL VLV CLYCOL FLOOR SUPPLY ISOLATION VALVE INLET ISOLATION VALVE REACTOR BLDG GLYCOL FLOOR RETURN ISOLATION VALVE OUTLET ISOLATION VALVE REACTOR BLDG GLYCOL FLOOR RETURN ISOLATION VALV GLYCOL SUPPLY ISOLATION VALVE GLYCOL AIR HANDLER RETURN ISOL VALV GLYCOL RETURN ISOLATION VALVE RCP 1 SEAL INJECTION ISOLATION VALVE RCP 2 SEAL INJECTION ISOLATION VALVE RCP 3 SEAL INJECTION ISOLATION VALVE RCP 4 SEAL INJECTION ISOLATION VALVE SEAL FLOW ISOLATION VALVE RCP SEAL INJECTION ISOL VALVE RC LOOP 3 LETDOWN FLOW RC LOOP 3 LETDOWN FLOW REGEN HT EXCH LETDOWN ISOL VLV A REGEN HT EXCH LETDOWN ISOL VLV B REGEN HT EXCH LETDOWN ISOL VLV C LETDOWN LINE ISOL VLV FLOW CONTROL NORMAL CHARGING ISOL VALVE RWST TO RHR PMP FLOW CNTL VLV SIS PUMP DISCHARGE TO RWST SHUTOFF VALVE Safety Function 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 3 3 3 3 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3,5 3 1,3,4 3,4 Page 70 of 444 Sequoyah Unit 2 Base List I UNID Description 2-FCV-063-0004 2-FCV-063-0005 2-FCV-063-0006 2-FCV-063-0007 2-FCV-063-0008 2-FCV-063-O011 2-FCV-063-0021 2-FCV-063-0022 2-FCV-063-0023 2-FCV-063-0025 2-FCV-063-0026 2-FCV-063-0039 2-FCV-063-0040 2-FCV-063-0047 2-FCV-063-0048 2-FCV-063-0064 2-FCV-063-0067 2-FCV-063-0070 2-FCV-063-0071 2-FCV-063-0072 2-FCV-063-0073 2-FCV-063-0077 2-FCV-063-0080 2-FCV-063-0084 2-FCV-063-0090 2-FCV-063-0091 2-FCV-063-0093 2-FCV-063-0094 2-FCV-063-0095 2-FCV-063-0098 2-FCV-063-0111 2-FCV-063-0112 SIS PUMP A-A DISCH TO RWST SHUTOFF VALVE RWST TO SIS PUMP FLOW CONTROL VALVE SIS PUMP INLET TO CVCS CHARGING PUMP SIS PUMP INLET TO CVCS CHARGING PUMP RHR HTX A T CVCS CHARGING PUMPS RHR HTX B TO SIS PUMPS SIS PUMP OUTLET TO SIS TEST LINE SIS PUMPS COLD LEG INJECTION CONTROL VLV SIS ACCUM FILL LINE ISOLATION VLV SIS CCP INJ TANK SHUTOFF VALVE SIS BORON INJ TANK SHUTOFF VALVE SIS BORON INJ TANK INLET SHUTOFF VALVE SIS BORON INJ TANK INLET SHUTOFF VALVE SIS PUMP A-A INLET VLV SIS PUMP B-B INLET VLV SIS ACCUM TANK N2 HDR INLET VLV SIS ACCUMULATOR TNK 4 FLOW ISOL VALVE SIS ACCUM TK4 FILL VLV SIS CHECK VLV FLOW ISOLATION VLV RHR CONTAINMENT SUMP FLOW ISOL VLV RHR CONTAINMENT SUMP FLOW ISOL VLV SIS ACCUM TK3 FILL VLV SIS ACCUMULATOR TNK 3 FLOW ISOL VALVE SIS CHK VLV ISOL HDR FLOW ISOLATION VLV CHARGING FLOW ISOL VLV CHARGING FLOW ISOL VLV RHR PUMP A-A DISCHARGE TO CL 2&3 RHR PUMP B-B DISCHARGE TO CL 1&4 SIS ACCUM TK 2 FILL VLV SIS ACCUMULATOR TNK 2 FLOW ISOL VALVE SIS CHK VLV LEAK TEST ISOLATION VLV SIS CHK VLV LEAK TEST ISOLATION VLV Safety Function 3,4 1,3,4 3,4 3,4 3,4 3,4 5 3,4 5 1,3,4 1,3,4 1,3,4 1,3,4 1,3,4 1,3,4 5 3 5 5 3,4,5 3,4,5 5 3 5 5 5 1,3,4 1,3,4 5 3 5 5 Page 71 of 444 Sequoyah Unit 2 UNID 2-FCV-063-0115 2-FCV-063-0118 2-FCV-063-0121 2-FCV-063-0138 2-FCV-063-0152 2-FCV-063-0153 2-FCV-063-0156 2-FCV-063-0157 2-FCV-063-0164 2-FCV-063-0172 2-FCV-063-0174 2-FCV-063-0175 2-FCV-064-0490D 2-FCV-067-0065 2-FCV-067-0066 2-FCV-067-0067 2-FCV-067-0068 2-FCV-067-0083 2-FCV-067-0087 2-FCV-067-0088 2-FCV-067-0089 2-FCV-067-0090 2-FCV-067-0091 2-FCV-067-0095 2-FCV-067-0096 2-FCV-067-0099 2-FCV-067-0103 2-FCV-067-0104 2-FCV-067-0105 2-FCV-067-0106 2-FCV-067-0107 2-FCV-067-0111 Base List 1 Description SIS ACCUM TK 1 FILL VLV SiS ACCUMULATOR TNK 1 FLOW ISOL VALVE SIS FLOW TO CL CHECK VLV TEST EMERGENCY BORATION FLOW CONT VLV SIS PUMP A-A OUTLET FLOW CONTROL VALVE SIS PUMP B-B OUTLET FLOW CONTROL VALVE SIS PUMP OUTLET TO RCS LP 1&3 HL SIS PUMP OUTLET TO RCS LP 2&4 HL SIS PUMP OUT TEST LINE RHR INJECTION OR RECIRC.AFTER LOCA SIS TEST LINE CHECK VLV TEST SIS PUMP B-B DISCH TO RWST SHUTOFF VLV ERCW HEADER B STRAINER FLUSHOUT VALVE EMERG DSL HTXS B1&B2 SUP VLV FROM HDR A EMERG DSL HTXS AI&A2 SUP VLV FROM HDR A EMERG DSL HTXS B1&B2 SUP VLV FROM HDR B EMERG DSL HTXS A1&A2 SUP VLV FROM HDR B LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL.VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE LOWER CNTMT D COOLERS SUPPLY ISOL VALVE Safety Function 5 3 5 3 1,3,4 1,3,4 1,3,4 1,3,4 5 3,4 5 3,4 0 0 0 0 0 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page 72 of 444 Sequoyah Unit 2 UNID 2-FCV-067-0112 2-FCV-067-0123 2-FCV-067-0124 2-FCV-067-0125 2-FCV-067-0126 2-FCV-067-0130 2-FCV-067-0131 2-FCV-067-0133 2-FCV-067-0134 2-FCV-067-0138 2-FCV-067-0139 2-FCV-067-0141 2-FCV-067-0142 2-FCV-067-0146 2-FCV-067-0176 2-FCV-067-0182 2-FCV-067-0184 2-FCV-067-0186 2-FCV-067-0295 2-FCV-067-0296 2-FCV-067-0297 2-FCV-067-0298 2-FCV-067-0490A 2-FCV-067-0491A 2-FCV-067-0491D 2-FCV-068-0305 2-FCV-068-0307 2-FCV-068-0308 2-FCV-068-0332 2-FCV-068-0333 2-FCV-070-0066 2-FCV-070-0085 Base List 1 Description LOWER CNTMT D COOLERS SUPPLY ISOL VALVE CNTMT SPRAY HTX B SUPPLY CONTROL VALVE CONTAINMENT SPRAY HTX B SUPPLY CONTROL VALVE CNTMT SPRAY HTX A SUPPLY CONTROL VALVE CONTAINMENT SPRAY HTX A DISCHARGE VALVE UPPER CNTMT VENT CLR A SUPPLY ISOL VLV UPPER CNTMT VENT CLR A DISCH LSOL VLV UPPER CNTMT VENT CLR C SUPPLY ISOL VLV UPPER CNTMT VENT CLR C DISCH ISOL VLV UPPER CNTMT VENT CLR B SUPPLY ISOL VLV UPPER CNTMT VENT CLR B DISCH ISOL VLV UPPER CNTMT VENT CLR D SUPPLY ISOL VLV UPPER CNTMT VENT CLR D SDISCH ISOL VLV CCS HTX 1A1/A12 DISCH CONTROL VLV SIS PUMP RM CLR-30-180 SUPPLY CNTL VLV SIS PUMP RM CLR-30-179 SUPPLY CNTL VLV CS PUMP RM CLR-30-177 SUPPLY CNTL VLV CS PUMP RM CLR-30-178 SUPPLY CNTL VLV UPPER CNTMT VENT CLR A DISCH ISOL VLV UPPER CNTMT VENT CLR C DISCH ISOL VLV UPPER CNTMT VENT CLR B DISCH ISOL VLV UPPER CNTMT VENT CLR D DISCH ISOL VLV ERCW HEADER B STRAINER BACKWASH VALVE ERCW HEADER A STRAINER BACKWASH VALVE ERCW HEADER A STRAINER FLUSHOUT VALVE RCS FLOW CNTL VLV WDS N2 MAAN TO PRT RCS FLOW CNTL VLV WDS GA TO PRT RCS FLOW CNTL VLV WDS GA TO PRT RCS PRESSURIZER FELIEF FLOW CTRL VALVE RCS PRESSURIZER FELIEF FLOW CTRL VALVE CCS SURGE TNK VENT VLV EXCESS LETON HTX OUTLET VLV Safety Function 5 0 0 0 0 5 5 5 5 5 5 5 5 0 0 0 0 0 5 5 5 5 0 0 0 5 5 5 2 2 0 5 Page 73 of 444 Sequoyah Unit 2 UNID 2-FCV-070-0087 2-FCV-070-0089 2-FCV-070-0090 2-FCV-070-0092 2-FCV-070-0133 2-FCV-070-0134 2-FCV-070-0139 2-FCV-070-0140 2-FCV-070-0141 2-FCV-070-0143 2-FCV-070-0153 2-FCV-070-0156 2-FCV-070-0168 2-FCV-070-0183 2-FCV-070-0207 2-FCV-072-0002 2-FCV-072-0020 2-FCV-072-0021 2-FCV-072-0022 2-FCV-072-0023 2-FCV-072-0039 2-FCV-072-0040 2-FCV-072-0041 2-FCV-074-O001 2-FCV-074-0002 2-FCV-074-0003 2-FCV-074-0012 2-FCV-074-0016 2-FCV-074-0021 2-FCV-074-0024 2-FCV-074-0028 2-FCV-074-0033 Base List 1 Description RC PMP THERM BARRIER RET CNTNMT ISOL VLV RC PMP OIL CLR RET CNTNMT ISOL VLV RC PMP THERM. BARRIER RET CNTNMT ISOL VLV RC PMP OIL CLR RET CNTNMT ISOL VLV RC PMP THERM BARRIER CONT ISOL VLV RC PMP THERM BARRIER CONT ISOL VLV RC PMP OIL CLR HDR CONT ISOL VLV RC PMP OIL CLR HDR CONT ISOL VLV RC PMP OIL CLR HDR CONT ISOL VLV EXCESS LETDOWN HTX CONT INLET ISOL VLV RHR HTX B CUTLET VALVE RHR HTX A CUTLER VALVE BA GAS STPR EVAP PKG B FLOW CONT VLV SAMPLE HTX HDR OUTLET VLV COND DEMIN WASTE EVAP BLDG SUPPLY CONTAINMENT SPRAY HDR B ISOLATION VALVE CNTMT SUMP SPRAY HDR B FLOW CONTROL VLV RWST TO SPRAY HDR B FLOW CONTROL VALVE RWST TO SPRAY HDR A FLOW CONTROL VALVE CNTMT SUMP SPRAY HDR A FLOW CONTROL VLV CONTAINMENT SPRAY HDR A ISOLATION VALVE RHR SPRAY HEADER A ISOLATION VALVE RHR SPRAY HEADER B ISOLATION VALVE RHR SYSTEM ISOLATION VALVE RHR SYSTEM ISOLATION VALVE RHR PUMP 2A-A INLET FLOW CONTROL VALVE RHR PUMP 2A-A MINIMUM FLOW VALVE RHR HT EX A OUTLET FLOW CONTROL VLV RHR PUMP 2B-B INLET FLOW CONTROL VALVE RHR PUMP 2B-B MINIMUM FLOW VALVE RHR HT EX B OUT FLOW CONTROL VLV RHR HT EX A BYPASS Safety Function 5 5 5 5 5 5 5 5 5 5 4 4 5 0 5 5 5 5 5 5 5 5 5 4 4 1,3,4 1,3,4 1,3,4 1,3,4 1,3,4 1,3,4 3,4 Page 74 of 444 Sequoyah Unit 2 UNID 2-FCV-074-0035 2-FCV-077-0009 2-FCV-077-O010 2-FCV-077-0018 2-FCV-077-0019 2-FCV-077-0020 2-FCV-077-0127 2-FCV-077-0128 2-FCV-084-0012 2-FCV-090-0107 2-FCV-090-0108 2-FCV-090-0109 2-FCV-090-0110 2-FCV-090-0111 2-FCV-090-0113 2-FCV-090-0114 2-FCV-090-0115 2-FCV-090-0116 2-FCV-090-0117 2-FCV-313-0222 2-FCV-313-0223 2-FCV-313-0224 2-FCV-313-0225 2-FCV-313-0229 2-FCV-313-0230 2-FCV-313-0231 2-FCV-313-0232 2-FI-074-0012 2-FI-074-0024 2-FLT-062-0065 2-FLT-062-0096 2-FLT-062-0100 Base List 1 Description RHR HT EX B BYPASS REACT COOLANT DRAIN TNK FLOW CNTL VLV REACT COOLANT DRAIN TNK FLOW CNTL VLV REACT COOLANT DRN TNK TO VENT HDR ISOL VLV REACT COOLANT DRN TNK TO VENT HDR ISOL VLV REACT COOLANT DRN TNK N2 SUPPLY FLOW CNTL VLV RAECT BLDG SUMP DISCH FLOW CNTL VLV REACT BLDG SUMP DISCH FLOW CNTL VLV PW RCS PRESS RELF TNK & RCP STANDPIPES CNTNMT BLDG LWR COMPT MON ISOL VLV CNTNMT BLDG LWR COMPT MON ISOL VLV CNTNMT BLDG LWR COMPT MON ISOL VLV CNTNMT BLDG LWR COMPT MON ISOL VLV CNTNMT BLDG LWR COMPT MON ISOL VLV CNTNMT BLDG UPR COMPT MON ISOL VLV CNTNMT BLDG UPR COMPT MON ISOL VLV CNTNMT BLDG UPR COMPT MON ISOL VLV CNTNMT BLDG UPR COMPT MON ISOL VLV CNTNMT BLDG UPR COMPT MON ISOL VLV ANNULUS ISOL VLV INSTRUMENT RM ISOL VLV ANNULUS ISOL VLV INSTRUMENT RM ISOL VLV ANNULUS ISOL VLV INSTRUMENT RM ISOL VLV ANNULUS ISOL VLV INSTRUMENT RM ISOL VLV RHR FLOW INDICATOR, TRAIN A RHR FLOW INDICATOR, TRAIN B SEAL WATER FILTER SEAL WATER INJECTION FILTERS REACTOR COOLANT FILTER Safety Function 3,4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 0 5 0 5 0 5 0 3,4 3,4 3 3 3 Page 75 of 444 Sequoyah Unit 2 UNID 2-FSV-032-0087 2-FSV-068-0394 2-FSV-068-0395 2-FSV-068-0396 2-FSV-068-0397 2-FT-062-0001 2-FT-062-0014 2-FT-062-0027 2-FT-062-0040 2-FV-030-0046 2-GENB-082-0002A 2-GENB-082-0002B 2-HEX-062-0055 2-HEX-062-0066 2-HEX-062-0077 2-HEX-062-0090 2-HEX-070-0015A 2-HEX-070-0015B 2-HEX-072-0007 2-HEX-072-0030 2-HEX-074-0010 2-HEX-074-0015 2-HEX-074-0020 2-HEX-074-0027 2-INVB-250-QM 2-INVB-250-QP 2-INVB-250-QS 2-INVB-250-QU 2-LCV-003-0148 2-LCV-003-0156 2-LCV-003-0164 2-LCV-003-0171 Base List 1 Description AUX AIR COMPR B-B COOLING WTR INLET REACTOR HEAD VENT ISOLATION VALVE REACTOR HEAD VENT ISOLATION VALVE REACTOR HEAD VENT ISOLATION VALVE REACTOR HEAD VENT ISOLATION VALVE RCP NO. 1 SEAL WATER FLOW RCP NO. 2 SEAL WATER.FLOW RCP NO. 3 SEAL WATER FLOW RCP NO. 4 SEAL WATER FLOW CONTAINMENT VACUUM RELIEF DIESEL GEN. 2A-A DIESEL GEN. 2B-B EXCESS LETDOWN HEAT EXCHANGER SEAL WATER HEAT EXCHANGER LETDOWN HEAT EXCHANGER REGENERATIVE HEAT EXCHANGER COMPONENT COOLING HX 2A1 COMPONENT COOLING HX 2A2 CONTAINMENT SPRAY HEAT EXCHANGER 2B CONTAINMENT SPRAY HEAT EXCHANGER 2A RHR PUMP 2A-A SEAL HEAT EXCHANGER RHR HEAT EXCHANGER 2A RHR PUMP 2B-B SEAL HEAT EXCHANGER RHR HEAT EXCHANGER 2B 120V AC VITAL INVERTER 2-1 120V AC VITAL INVERTER 2-11 120V AC VITAL INVERTER 2-111 120V AC VITAL INVERTER 2-VI STM GEN #3 LEVEL CONTROL VALVE STM GEN #2 LEVEL CONTROL VALVE STM GEN #1 LEVEL CONTROL VALVE STM GEN #4 LEVEL CONTROL VALVE Safety Function 5 4 4 4 4 3 3 3 3 5 0 0 0 3 3 3 0 0 5 5 1,3,4 1,3,4 1,3,4 1,3,4 0 0 0 0 4,5 4,5 4,5 4,5 Page 76 of 444 Sequoyah Unit 2 UNID 2-LCV-003-0172 2-LCV-003-0173 2-LCV-003-0174 2-LCV-003-0175 2-LCV-062-0132 2-LCV-062-0133 2-LCV-062-O135 2-LCV-062-0136 2-LCV-070-0063 2-LOCL-099-RO01 2-LOCL-099-RO02 2-LOCL-099-RO03 2-LOCL-099-RO04 2-LOCL-099-RO05 2-LOCL-099-RO06 2-LOCL-099-RO07 2-LOCL-099-RO08 2-LOCL-099-RO09 2-LOCL-099-ROIO 2-LOCL-099-ROll 2-LOCL-099-RO12 2-LOCL-099-RO13 2-LOCL-099-R046 2-LOCL-099-R047 2-LOCL-099-R048 2-LOCL-099-R049 2-LOCL-099-RO50 2-LOCL-099-R051 2-LOCL-099-R052 2-LOCL-099-R053 2-LOCL-099-R054 2-LOCL-099-R055 Base List 1 Description STM GEN #3 LEVEL CONTROL VALVE STM GEN #2 LEVEL CONTROL VALVE STM GEN #1 LEVEL CONTROL VALVE STM GEN #4 LEVEL CONTROL VALVE VCT OUTLET ISOLATION VALVE LEVEL CONTROL VCT OUTLET ISOLATION VALVE LEVEL CONTROL CHARGING PUMP FLOW -RWST CHARGING PUMP FLOW -RWST CCS SURGE TNK DEMIN WATER INLET VLV REACTOR PROTECTION SET 1 REACTOR PROTECTION SET 1 REACTOR PROTECTION SET 1 REACTOR PROTECTION SET 1 REACTOR PROTECTION SET 2 REACTOR PROTECTION SET 2 REACTOR PROTECTION SET 2 REACTOR PROTECTION SET 2 REACTOR PROTECTION SET 3 REACTOR PROTECTION SET 3 REACTOR PROTECTION SET 3 REACTOR PROTECTION SET 4 REACTOR PROTECTION SET 4 SOLID STATE PROTECTION TRAIN A SOLID STATE PROTECTION TRAIN A SOLID STATE PROTECTION TRAIN A SOLID STATE PROTECTION TRAIN B SOLID STATE PROTECTION TRAIN B SOLID STATE PROTECTION TRAIN B TEST PANEL A TEST PANEL B NSSS AUXILIARY RELAY PANEL A NSSS AUXILIARY RELAY PANEL B Safety Function 4,5 4,5 4,5 4,5 3 3 3,5 3,5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 77 of 444 Sequoyah Unit 2 UNID 2-LOCL-099-R058 2-LT-003-0038 2-LT-003-0039 2-LT-003-0042 2-LT-003-0043 2-LT-003-0051 2-LT-003-0052 2-LT-003-0055 2-LT-003-0056 2-LT-003-0093 2-LT-003-0094 2-LT-003-0097 2-LT-003-0098 2-LT-003-0106 2-LT-003-0107 2-LT-003-0110 2-LT-003-0111 2-LT-062-0129A 2-LT-062-0129C 2-LT-062-0130A 2-LT-062-0130C 2-LT-068-0320 2-LT-068-0335 2-LT-068-0339 2-PCV-001-0005 2-PCV-001-0012 2-PCV-001-0023 2-PCV-O01-0030 2-PCV-062-0081 2-PCV-068-0334 2-PCV-068-0340A 2-PDT-030-0044 Base List 1 Description NSSS AUXILIARY RELAY PANEL COMMON STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)STM GEN 1 LEVEL XMTR (NR)VOLUME CONTROL TANK LEVEL XMITTER VOLUME CONTROL TANK LEVEL XMITTER VOLUME CONTROL TANK LEVEL XMITTER VOLUME CONTROL TANK LEVEL XMITTER RCS PRESSURIZER LEVEL TRANSMITTER RCS PRESSURIZER LEVEL TRANSMITTER RCS PRESSURIZER LEVEL TRANSMITTER SG1 MAIN STM HDR PWR RELIEF CONTROL VLV SG2 MAIN STM HDR PWR RELIEF CONTROL VLV SG3 MAIN STM HDR PWR RELIEF CONTROL VLV SG4 MAIN STM HDR PWR RELIEF CONTROL VLV LETDOWN HEAT EXCH PRESS CONT RCS PRESSURIZER POWER RELIEF VALVE RCS PRESSURIZER POWER RELIEF VALVE CONTAINMENT PRESSURE TRANSMITTER Safety Function 0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 3 3 3 3 3 3 3 4,5 4,5 4,5 4,5 3 2,4 2,4 5 Page 78 of 444 Sequoyah Unit 2 UNID 2-PDT-062-0008 2-PDT-062-0021 2-PDT-062-0034 2-PDT-062-0047 2-PMP-003-0118 2-PMP-003-0128 2-PM P-018-054/4 2-PMP-018-064/3 2-PMP-018-065/3 2-PMP-018-065/4 2-PMP-062-0104 2-PMP-062-0108 2-PMP-063-0010 2-PMP-063-0015 2-PMP-068-0008 2-PMP-068-0031 2-PMP-068-0050 2-PMP-068-0073 2-PMP-070-0033 2-PMP-070-0059 2-PMP-070-0130 2-PMP-070-0131 2-PM P-072-0010 2-PMP-072-0027 2-PMP-074-0010 2-PMP-074-0020 2-PNLA-082-TV 2-PNLA-082-TW 2-PNLB-202-SC 2-PNLB-202-SD 2-PRS-068-0320 2-PT-030-0310 Base List 1 Description RCP NO 1 DP ACROSS NO 1 SEAL RCP NO 2 DP ACROSS NO 1 SEAL RCP NO 3 DP ACROSS NO 1 SEAL RCP NO 4 DP ACROSS NO 1 SEAL MOTOR DRIVEN AUX FEEDWATER PUMP 2A-A MOTOR DRIVEN AUX FEEDWATER PUMP 2B-B DSL 2B2 DAY TNK FUEL XFER PUMP DSL 2A2 DAY TNK FUEL XFER PUMP DSL 2A1 DAY TNK FUEL XFER PUMP DSL 2B1 DAY TNK FUEL XFER PUMP CENTRIFUGAL CHARGING PUMP 2B-B CENTRIFUGAL CHARGING PUMP 2A-A SIS PUMP 2A-A SIS PUMP 2B-B REACTOR COOLANT PUMP 1 REACTOR COOLANT PUMP 2 REACTOR COOLANT PUMP 3 REACTOR COOLANT PUMP 4 CCS PUMP 2B-B CCS PUMP 2A-A CCS THERMAL BARRIER BOOSTER PUMP 28-B CCS THERMAL BARRIER BOOSTER PUMP 2A-A CONTAINMENT SPRAY PUMP 2B-B CONTAINMENT SPRAY PUMP 2A-A RHR PUMP 2A-A RHR PUMP 2B-B DG 2A-A DISTRIBUTION AND CONTROL BOARD DG 2B-B DISTRIBUTION AND CONTROL BOARD 6900V LOGIC RELAY PANEL 2A 6900V LOGIC RELAY PANEL 2B PRESSURIZER CONTAINMENT PRESSURE TRANSMITTER Safety Function 3,5 3,5 3,5 3,5 4 4 4 4 4 4 3 3 1,3,4 1,3,4 2 2 2 2 0 0 0 0 5 5 1,3,4 1,3,4 0 0 0 0 2,3 5 Page 79 of 444 Sequoyah Unit 2 UNID 2-PT-030-0311 2-PT-068-0062 2-PT-068-0069 2-PT-068-0323 2-PT-068-0334 2-PT-068-0340 2-RCK-250-RCRD 2-RPV-068-0100 2-SGEN-068-0101 2-SGEN-068-0102 2-SGEN-068-0103 2-SGEN-068-0104 2-STN-067-0490 2-STN-067-0491 2-TCV-062-0079 2-TE-068-0001 2-TE-068-0024 2-TE-068-0043 2-TE-068-0065 2-TN K-018-061/3 2-TNK-018-061/4 2-TNK-018-076/3 2-TNK-018-076/4 2-TN K-062-0129 2-TN K-0623-0044 2-TNK-063-0037 2-TN K-063-0060 2-TN K-063-0081 2-TN K-063-0099 2-TNK-063-0119 2-TNK-068-0300 2-TNK-070-0063 Base List 1 Description CONTAINMENT PRESSURE TRANSMITTER RCS WIDE RANGE PRESSURE LOOP 4 HOT LEG RCS WIDE RANGE PRESSURE LOOP 1 HOT LEG RCS PRESSURIZER PRESSURE TRANSMITTER RCS PRESSURIZER PRESSURE TRANSMITTER RCS PRESSURIZER PRESSURE TRANSMITTER 120V AC INST PWR TRANSFER RACK (2-M-7)REACTOR VESSEL STEAM GENERATOR 1 STEAM GENERATOR 2 STEAM GENERATOR 3 STEAM GENERATOR 4 ERCW STRAINER B2B-B ERCW STRAINER A2A-A LETDOWN FLOW TEMP DIVERSION CONT VLV RCS LOOP 1 HOT LEG TEMP RCS LOOP 2 HOT LEG TEMP RCS LOOP 3 HOT LEG TEMP RCS LOOP 4 HOT LEG TEMP ENGINE 2A1 DAY TANK 550 GAL ENGINE 2B1 DAY TANK 550 GAL ENGINE 2A2 DAY TANK 550 GAL ENGINE 2B2 DAY TANK 550 GAL VOLUME CONTROL TANK LEVEL XMITTER REFUELING WATER STORAGE TANK BORON INJECTION TANK 1A (CCP INJ TNK)SIS ACCUMULATOR TANK NO 4 SIS ACCUMULATOR TANK NO 3 SIS ACCUMULATOR TANK NO 2 SIS ACCUMULATOR TANK NO 1 PRESSURIZER RELIEF TANK COMPONENT COOLING WATER SURGE TANK Safety Function 5 2,4 2,4 2 2 2 0 2 2 2 2 2 0 0 3 2,4 2,4 2,4 2,4 4 4 4 4 3 1,3,4 1,3,4 1,3 1,3 1,3 1,3 2,4 0 Page 80 of 444 Sequoyah Unit 2 Base List I UNID 2-TN K-082-0224 2-TNK-082-0225 2-TNK-082-0234 2-TNK-082-0235 2-TN K-082-0254 2-TN K-082-0255 2-TN K-082-0264 2-TNK-082-0265 2-VLV-001-0512/0531 2-VLV-001-0513 2-VLV-001-0514 2-VLV-001-0515 2-VLV-001-0516 2-VLV-001-0517 2-VLV-001-0518 2-VLV-001-0519 2-VLV-001-0520 2-VLV-001-0521 2-VLV-001-0522 2-VLV-001-0523 2-VLV-001-0524 2-VLV-001-0525 2-VLV-001-0526 2-VLV-001-0527 2-VLV-001-0528 2-VLV-001-0529 2-VLV-001-0530 2-VLV-001-0539 2-XCT-250-QC2A 2-XCT-250-QC2B 2-XFA-202-0312 2-XFA-202-0313 Description DSL 2A1 STARTING AIR TANK A 35 CF DSL 2A2 STARTING AIT TANK A 35 CF DSL 2A1 STARTING AIT TANK B 35 CF DSL 2A2 STARTING AIR TANK B 35 CF DSL 2B1 STARTING AIR TANK A 35 CF DSL 2B2 STARTING AIR TANK A 35 CF DSL 2B1 STARTING AIR TANK B 35 CF DSL 2B2 STARTING AIR TANK B 35 CF MAIN STEAM SAFETY VALVES, SG-3 MAIN STEAM SAFETY VALVES, SG-3 MAIN STEAM SAFETY VALVES, SG-3 MAIN STEAM SAFETY VALVES, SG-3 MAIN STEAM SAFETY VALVES, SG-3 MAIN STEAM SAFETY VALVES, SG-2 MAIN STEAM SAFETY VALVES, SG-2 MAIN STEAM SAFETY VALVES, SG-2 MAIN STEAM SAFETY VALVES, SG-2 MAIN STEAM SAFETY VALVES, SG-2 MAIN STEAM SAFETY VALVES, SG-1 MAIN STEAM SAFETY VALVES, SG-1 MAIN STEAM SAFETY VALVES, SG-1 MAIN STEAM SAFETY VALVES, SG-1 MAIN STEAM SAFETY VALVES, SG-1 MAIN STEAM SAFETY VALVES, SG-4 MAIN STEAM SAFETY VALVES, SG-4 MAIN STEAM SAFETY VALVES, SG-4 MAIN STEAM SAFETY VALVES, SG-4 CCS SURGE TNK VACUUM RELIEF 480/240 -120V AC INST PNL TRANFRMR 2A 480/240 -120V AC INST PWR TRANSFRMR 2B ERCW TRANSFORMER 2A-A 480V SHUTDOWN TRANSFORMER 2A2-A Safety Function 0 0 0 0 0 0 0 0 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 0 0 0 0 0 Page 81 of 444 Sequoyah Unit 2 Base List 1 UNID Description 2-XFA-202-0314 2-XFA-202-0315 2-XFA-202-0316 2-XFA-202-0317 2-XFA-202-0318 2-XFA-202-0319 480V SHUTDOWN TRANSFORMER 2A-A 480V SHUTDOWN TRANSFORMER 2A1-A ERCW TRANSFORMER 2B-B 480V SHUTDOWN TRANSFORMER 2B2-B 480V SHUTDOWN TRANSFORMER 2B-B 480V SHUTDOWN TRANSFORMER 2B1-B Safety Function 0 0 0 0 0 0 Page 82 of 444 Appendix C: Base List 2 This Appendix includes the Sequoyah Unit 2 Base List 2.Page 83 of 444 Sequoyah Unit 2 Base List. 2 UNID SQN-0-BCTB-078-0009-B SQN-0-BCTB-078-0012-A SQN-0-BCTB-078-0035-A SQN-0-BCTB-078-0035-B SQN-0-BCTC-078-0001 SQN-0-BCTD-078-0019-A SQN-0-BCTD-078-0020-B SQN-0-HEX-078-0017 SQN-0-HEX-078-0018 SQN-0-ISIV-078-0204C SQN-0-ISIV-078-0206C SQN-0-ISIV-078-0209B SQN-0-ISIV-078-0210B SQN-0-ISIV-078-0211C SQN-0-ISIV-078-0212C SQN-0-ISIV-078-0213C SQN-O-ISIV-078-0214C SQN-0-ISIV-078-0230B SQN-0-ISIV-078-0231B SQN-0-ISIV-078-0232B SQN-0-ISIV-078-0233B SQN-0-MTRB-078-0001 SQN-0-MTRB-078-0009-B SQN-0-MTRB-078-0012-A SQN-0-MTRB-078-0019-A SQN-0-MTRB-078-0020-B SQN-0-MTRB-078-0035-S SQN-0-PMP-078-0001 SQN-0-PM P-078-0009-B SQN-0-PM P-078-0012-A SQN-0-PMP-078-0019 SQN-0-PMP-078-0020 SQN-0-PMP-078-0035-S SQN-0-PMP-078-0042 SQN-0-TA-078-0004A SQN-0-TE-078-0004 SQN-0-TI-078-0005 SQN-O-TI-078-0006 SQN-0-TI-078-0017 SQN-0-TI-078-0018 SQN-0-TIS-078-0004 SQN-0-TW-078-0005 SQN-0-TW-078-0006 Description SPENT FUEL PIT PUMP B-B 45N779-4 SPENT FUEL PIT PUMP A-A 45N779-4 SPENT FUEL PIT BACK-UP PUMP C-S (NORMAL SUP)SPENT FUEL PIT BACK-UP PUMP C-S (ALT SUP)SPENT FUEL PIT SKIMMER PUMP REFUELING WATER PURIFICATION PUMP A REFUELING WATER PURIFICATION PUMP B SPENT FUEL PIT HEAT EXCHANGER B SPENT FUEL PIT HEAT EXCHANGER A PNL ISOL VLV TO PI-78-10 PNL ISOL VLV TO PI-78-13 HIGH SIDE PANEL ISOLATION VALVE FOR FI-78-16 LOW SIDE PANEL ISOLATION VALVE FOR FI-78-16 PNL ISOL VLV FOR 0-PI-78-21 PNL ISOL VLV FOR 0-PI-78-22 PNL ISOL VLV FOR 0-PI-78-23 PNL ISOL VLV FOR 0-PI-78-24 HIGH SIDE ISOLATION VALVE FOR 0-FI-078-0039 LOWSIDE ISOLATION VALVE FOR 0-FI-078-0039 HIGH SIDE ISOLATION VALVE FOR 0-FI-078-0040 LOW SIDE ISOLATION VALVE FOR 0-FI-078-0040 SPENT FUEL PIT SKIMMER PUMP SPENT FUEL PIT PUMP B-B 45N779-4 SPENT FUEL PIT PUMP A-A 45N779-4 REFUELING WATER PURIFICATION PUMP A MOTOR REFUELING WATER PURIFICATION PUMP MOTOR B SPENT FUEL PIT C-S (NOR & ALT PWR SUPPLY)SPENT FUEL PIT SKIMMER PUMP SPENT FUEL PIT PUMP B SPENT FUEL PIT PUMP A REF WTR PUR PUMP A-A REF WTR PUR PUMP B-B SFP COOLING BACK-UP PUMP C-S SGLWHT TRANSFER PUMP TO TRANSFER CANAL OR SFP SPENT FUEL PIT WATER TEMP HI SPENT FUEL PIT WATER TEMP SFPCS HT EX A INLET TEMP SFPCS HT EX B INLET TEMP SFPCS HT EX B OUTLET TEMP SFPCS HT EX A OUTLET TEMP SPENT FUEL PIT WATER TEMP HI SFPCS HT EX A INLET TEMP SFPCS HT EX B INLET TEMP Page 84 of 444 Sequoyah Unit 2 Base List 2 UNID SQN-0-TW-078-0017 SQN-0-TW-078-0018 SQN-0-VLV-078-0201A SQN-0-VLV-078-0202A SQN-0-VLV-078-0203A SQN-0-VLV-078-0204A SQN-0-VLV-078-0205A SQN-0-VLV-078-0206A SQN-0-VLV-078-0207A SQN-0-VLV-078-0208A SQN-0-VLV-078-0209A SQN-0-VLV-078-0210A SQN-0-VLV-078-0211A SQN-0-VLV-078-0211B SQN-0-VLV-078-0212A SQN-0-VLV-078-0212B SQN-0-VLV-078-0213A SQN-0-VLV-078-0213B SQN-0-VLV-078-0214A SQN-0-VLV-078-0214B SQN-0-VLV-078-0215A SQN-0-VLV-078-0216A SQN-0-VLV-078-0217A SQN-0-VLV-078-0218A SQN-0-VLV-078-0219A SQN-0-VLV-078-0220A SQN-0-VLV-078-0221A SQN-0-VLV-078-0222A SQN-0-VLV-078-0223A SQN-0-VLV-078-0224A SQN-0-VLV-078-0230A SQN-0-VLV-078-0231A SQN-0-VLV-078-0232A SQN-0-VLV-078-0233A SQN-0-VLV-078-0501 SO.N-0-VLV-078-0502 SQN-0-VLV-078-0503 SQN-0-VLV-078-0504 SQN-0-VLV-078-0505 SQN-0-VLV-078-0506 SQN-0-VLV-078-0507 SQN-0-VLV-078-0508 SQN-0-VLV-078-0509 Description SFPCS HT EX B OUTLET TEMP SFPCS HT EX A OUTLET TEMP RT VLV TO PI-78-2 RT VLV TO PI-78-7 RT VLV TO P 1-78-8 RT VLV TO PI-78-10 RT VLV TO PI-78-11 RT VLV TO PI-78-13 RT VLV TO PI-78-14 RT VLV TO PI-78-15 RT VLV TO FI-78-16 RT VLV TO FI-78-16 RT VLV TO PI-78-21 VENT VALVE FOR 0-PI-78-21 RT VLV TO PI-78-22 VENT VALVE FOR O-PI-78-22 RT VLV TO PI-78-23 VENT VALVE FOR 0-PI-78-23 RT VLV TO PI-78-24 VENT VALVE FOR 0-PI-78-24 RT VLV TO PI-78-25 RT VLV TO PI-78-26 RT VLV TO PI-78-27 RT VLV TO PI-78-29 RT VLV TO PDI-78-30 RT VLV TO PDI-78-30 SF PMP A-A PRESS TEST SF PMP B-B PRESS TEST RT VLV TO PI-78-37 RT VLV TO PI-78-38 RT VLV TO F 1-78-39 RT VLV TO FI-78-39 RT VLV TO FI-78-40 RT VLV TO FI-78-40 SFP PUMP A-A SUCTION SFP PUMP B-B SUCTION SFP PUMP A-A SYS DR SFP PUMP B-B SYS DR SFP PUMP A-A CAS DR SFP PUMP B-B CAS DR SFP PUMP A-A CAS VT SFP PUMP B-B CAS VT SFP PUMP A-A CHECK Page 85 of 444 Sequoyah Unit 2 UNID SQN-0-VLV-078-0510 SQN-O-VLV-078-0511 SQN-O-VLV-078-0512 SQN-O-VLV-078-0513 SQN-O-VLV-078-0514 SQN-O-VLV-078-0515 SQN-O-VLV-078-0516 SQN-O-VLV-078-0517 SQN-O-VLV-078-0518 SQN-O-VLV-078-0519 SQN-O-VLV-078-0521 SQN-O-VLV-078-0522 SQN-O-VLV-078-0523 SQN-O-VLV-078-0524 SQN-O-VLV-078-0525 SQN-O-VLV-078-0526 SQN-O-VLV-078-0527 SQN-O-VLV-078-0528 SQN-O-VLV-078-0529 SQN-O-VLV-078-0530 SQN-O-VLV-078-0531 SQN-O-VLV-078-0532 SQN-O-VLV-078-0533 SQN-O-VLV-078-0534 SQN-O-VLV-078-0535 SON-O-VLV-078-0536 SQN-O-VLV-078-0537 SQN-O-VLV-078-0538 SQN-O-VLV-078-0539 SON-O-VLV-078-0540 SQN-O-VLV-078-0541 SQN-O-VLV-078-0542 SON-O-VLV-078-0543 SQN-O-VLV-078-0544 SQN-O-VLV-078-0545 SQN-O-VLV-078-0546 SQN-O-VLV-078-0547 SQN-O-VLV-078-0548 SQN-O-VLV-078-0549 SQN-O-VLV-078-0550 SQN-O-VLV-078-0551 SQN-O-VLV-078-0552 SQN-O-VLV-078-0553 Base List 2 Description SFP PUMP B-B CHECK HX A DISCH HX B DISCH COOL LOOP SOV DEM WATER MAKE-UP SOV FROM SFP FILTER SOV COOL LP CASK LOAD SOV SOV TO SFP FILTER SOV TO SFP FILTER SFP PUMP DISCH TO HUT SFP SOV TO SFP FILTER PRIMARY WATER-SFP SOY DEM SOV TO SFP FILTER SFP FILTER ISOL-INLET SFP FILTER ISOL-DISCH SFP SOV TO DEM SFP DEM INLET CHECK VLV FROM RESIN TK SOV SFP DEM VENT TO WDS SRST SOV SFP DEM DR DEM SOV FROM RWPP DEM SOV TO RWPF DEM CHECK TO RWPF RWPP TO RWPF SOV RWPF B ISOL-INLET RWPF A ISOL-INLET RWPF B VENT RWPF A VENT RWPF B DR RWPF A DR RWPF B ISOL-DISCH RWPF A ISOL-DISCH RWPF TO CVCS HLDUP TK SAMPLING CONN VALVE TO REF CAVITY CHECK TO TRAN CANAL SOV SAMPLING CONN VALVE RWPP B ISOL-DISCH RWPP A ISOL-DISCH RWPP B CHECK RWPP A CHECK RWPP B CASING DR Page 86 of 444 Sequoyah Unit 2 UNID SQN-0-VLV-078-0554 SQN-0-VLV-078-0555 SQN-0-VLV-078-0556 SQN-0-VLV-078-0563 SQN-0-VLV-078-0564 SQN-0-VLV-078-0565 SQN-O-VLV-078-0568 SQN-0-VLV-078-0569 SQN-0-VLV-078-0570 SQN-0-VLV-078-0571 SQN-0-VLV-078-0572 SQN-0-VLV-078-0573 SQN-0-VLV-078-0574 SQN-0-VLV-078-0575 SQN-0-VLV-078-0576 SQN-0-VLV-078-0577 SQN-0-VLV-078-0578 SQN-0-VLV-078-0579 SQN-0-VLV-078-0581 SQN-0-VLV-078-0582 SQN-0-VLV-078-0583 SQN-0-VLV-078-0584 SQN-0-VLV-078-0585 SQN-0-VLV-078-0586 SQN-0-VLV-078-0587 SQN-0-VLV-078-0588 SQN-O-VLV-078-0589 SQN-0-VLV-078-0590 SQN-0-VLV-078-0591 SQN-0-VLV-078-0592 SQN-0-VLV-078-0593 SQN-0-VLV-078-0594 SQN-O-VLV-078-0595 SQN-0-VLV-078-0596 SQN-0-VLV-078-0597 SQN-0-VLV-078-0598 SQN-0-VLV-078-0599 SQN-0-VLV-078-0606 SQN-0-VLV-078-0607 SQN-0-VLV-078-0608 SQN-O-VLV-078-0611 SQN-0-VLV-078-0612 SQN-0-VLV-078-0613 Base List 2 Description RWPP A CASING DR RWPP B SUCTION SOV RWPP A SUCTION SOV FROM TRAN CANAL CHECK FROM TRAN CANAN SOV FROM TRAN CANAL VENT FROM CVCS REC PUM SOV SFP SKIM SOV SUCT CLEAN SOV SFP SKIM STR VENT SFP SKIM STR DR SFP SKIM PUMP DR SFP SKIM FILTER ISOL SFP SKIM FILTER VENT SFP SKIM FILTER DR SFP SKIM FILTER ISOL SFP FILTER VENT SFP FILTER DR SFP PUMP C-S SUCTA SFP PUMP C-S SUCT B SFP PUMP C-S CAS VT SFP PUMP C-S SYS DR SFP PUMP C-S CAS DR SFP PUMP C-S CK SFP PUMP C-S TO TR B SFP PUMP C-S TO TR A COOLING LOOP A LP DR COOLING LOOP B LP DR FLOOD MODE LOOP-VENT RWP FILTER PIPING DR RWP FILTER PIPING DR SFP FILTER PIPING DR HX A OUTLET DR HX B OUTLET DR HX OUTLET PIPING DR RWP PUMPS DISCH ISO RWP PUMP DISCH ISOL VLV HUT TO REFUEL CANAL ISOL HUT TO REFUEL CANAL TELL-TALE DRAIN HUT TO REFUEL CANAL TELL-TALE VENT SG LAYUP WATER HOLDUP TK RECIRC ISO VLV SGLWHT TRANSFER PIPING DR VLV SGLWHT RECIR DR & SAMPLE VLV Page 87 of 444 Sequoyah Unit 2 Base List 2 UNID SQN-O-VLV-078-0614 SQN-O-VLV-078-0615 SQN-O-VLV-078-0616 SQN-O-VLV-078-0617 SQN-O-VLV-078-0618 SQN-O-VLV-078-606 SQN-O-XFA-078-0019-A SQN-O-XFA-078-0020-B SQN-O-XS-078-0036A-S SQN-O-XS-078-0036B-S SQN-O-XSW-078-0035-S SQN-1-VLV-078-0225A SQN-1-VLV-078-0226A SQN-1-VLV-078-0227A SQN-1-VLV-078-0228A SQN-1-VLV-078-0229A SQN-1-VLV-078-0557 SQN-1-VLV-078-0558 SQN-1-VLV-078-0559 SQN-1-VLV-078-0560 SQN-1-VLV-078-0561 SQN-1-VLV-078-0562 SQN-1-VLV-078-0566 SQN-1-VLV-078-0567 SQN-1-VLV-078-0600 SQN-1-VLV-078-0601 SQN-1-VLV-078-0602 SQN-1-VLV-078-0610 SQN-2-VLV-078-0225A SQN-2-VLV-078-0226A SQN-2-VLV-078-0227A SQN-2-VLV-078-0228A SQN-2-VLV-078-0229A SQN-2-VLV-078-0557 SQN-2-VLV-078-0558 SQN-2-VLV-078-0559 SQN-2-VLV-078-0560 SQN-2-VLV-078-0561 SQN-2-VLV-078-0562 SQN-2-VLV-078-0566 SQN-2-VLV-078-0567 SQN-2-VLV-078-0600 SQN-2-VLV-078-0601 Description SLGWHT TRANSFER PIPING DR VLV SGLWHT TRANSFER PIPING ISO VLV SGLWHT TRANSFER PIPING CHK VLV SGLWHT TRANSFER PIPING ISO VLV SGLWHT TRANSFER PIPING ISO VLV BLOCK VALVE HUT TO SFP TRANSFER CANAL TRANSFORMER TRANSFORMER SFPCS BACK-UP PUMP C-S POWER TRANSFER SW SFPCS BACK-UP PUMP C-S POWER TRANSFER SW SFP COOLING BACK-UP PUMP C-S XFR SW REF CAV ISO TEST CONN REF CAV ISO TEST CONN WDS ISO TEST CONN WDS ISO TEST CONN WDS ISO TEST CONN REF CAVITY ISOL REF CAVITY ISOL REF CAVITY ISOL REF CAVITY ISOL REF CAVITY ISOL FROM REF CAVITY CHECK FROM SIS RWST CHECK TO CSS RWST SOV REFUEL CAV SUPPLY BLOCK CONT ISO VENT CONT ISOL TEST CONN FUEL TRANSFER TUBE WAFER VALVE REF CAV ISO TEST CONN REF CAV ISO TEST CONN WDS ISO TEST CONN WDS ISO TEST CONN WDS ISO TEST CONN REF CAVITY ISOL REF CAVITY ISOL REF CAVITY ISOL REF CAVITY ISOL REF CAVITY ISOL FROM REF CAVITY CHECK FROM SIS RWST CHECK TO CSS RWST SOV REFUEL CAV SUPPLY BLOCK CONT ISO VENT Page 88 of 444 Sequoyah Unit 2 UNID SQN-2-VLV-078-0602 SQN-2-VLV-078-0610 SQN-2-ZS-078-0041A SQN-2-ZS-078-0041B Base List 2 Description CONT ISO TEST CONN FUEL TRANSFER TUBE WAFER VALVE REF CNL VORTEX SUPP ZONE SW REF CNL VORTEX SUPP ZONE SW Page 89 of 444 Appendix D: SWELs and Area List This Appendix includes the Sequoyah Unit 2 SWELs and Area List.Page 90 of 444 Sequoyah Unit 2 Seismic Walkdown Equipment List 1 Created By. Q* *-Approved By: Q)01ýRisk New or 5 Safety Enhanced Area Anchorage Item # Class UNID Description System 8uidln. Elevation Significant Replaced Functions forIPEEE Walkby Verification 1 0 D-DRYA-032-0002.8 Aux Control Air Dryer 8-8 032 AUXILIARY 734 (RCA) 0 32 2 1 2-BDC-201 -FL-A 480V ERCW MCC 2A-A 201 ERCW 704 0 8 3 1 2-8DC.201-FN-B 480V ERCW MCC 28-B 201 ERCWA 704 0 11 4 1 2-BDC-201-FQ-A 480V DIESEL AUXILIARY BOARD 2A1-A 201 DIESEL GEN. 740 0 Y 2 Y S I 2-BDC-201-FU-8 480V DIESEL AUXILIARY BOARD 281-8 201 DIESEL GEN. 740 1 0 yS1 5 6 1 2-BDC-201-GM-A 480V REACTOR MOV BI0 2A2-A 201 AUXILIARY 749 Y 0 Y 23 7 1 2-80C-201-GN-8 480V REACTOR MOV 90 281-8 201 AUXIUARY 749 Y 0 Y 22 8 1 2-BDC-201-JK-A 480V CONT & AUX BLDG VENT 9D 2A2-A 201 AUXILIARY 734 0 Y 15 9 2 2-80-201-DO-A 480V SHUTDOWN 8O 2A2-A 201 AUXILIARY 734 " 0 Y Is 10 2 2-BD9-201-DP-B 480VSHUTDOWN D2BO-8 201 AUXILIARY 734 Y 0 Y 16 11 2 2-BDB-201-DQ-B 480V SHUTDOWN So 282-8 201 AUXIUARY 734 Y 0 Y 17 12 3 2.BDA-202-CO 6900V SHUTDOWN BOARD 2A-A 202 AUXIUARY 734 O 0 Y 31 13 3 2-BDB-202-CP 6900V SHUTDOWN BOARD 29-B 202 AUXILIARY 734 0 Y 36 14 4 2-OXF-202-2A-A 480V SHUTDOWN TRANSFORMER 2A1/-A 202 AUXILIARY 749 3 Y 19 Y 15 ' 4 2-OXF-202-29B-SO XFMR 29-B 202 AUXIUARY 749 3 Y 18 Y 16 4 2-OXF-202-DN-A 48ov SHUTDOWN TRANSFORMER 2A-A 202 AUXILIARY 749 V 3 Y 19 Y 17 4 2-OXF-202.DQ.8 SD XFMR 282-8 202 AUXIUARY 749 1 3 Y 18 Y 18 4 2-XFA-202-0312 ERCW TRANSFORMER 2A-A 202 ERCW 704 0 8 Y 19 4 2-XFA-202-0316 ERCW TRANSFORMER 28-8 202 ERCW 704 0 21 Y 20 See SWEL 2for Item 20.21 .5 12-PMP-003.-0128 MOTOR DRIVEN AUX FEEDWATER PUMP-B -003 AUXILIARY 690 Y 2,4 38 Y 22 S 2-PMP.062-0104 CENT. CHARGING PUMP 28.8 062 AUXILIARY 669 3 35 Y 23 5 2-PMP-063-0010 SAFETY INJECTION PUMP 2A-A 063 AUXILIARY 669 '1.3,4 26 Y 24 5 2-PMP-D70-0059-A CCS PUMP 2A-A 070 AUXILIARY 690 Y 0 27 Y 25 6 O-PMP-067-0452 ERCW PUMP N-B 067 ERCW 720 0 10 Y 26 6 D-PMP-067-0464 ERCW PUMP R-A 067 ERCW 720 0 .7 Y 27 6 C-PMP-067-04B2-, ERCW SCREEN WASH PUMP C-B 067 ERCW 720 0 10 Y 28 6 D-PMP-067-0487-A ERCW SCREEN WASH PUMP D-A 067 ERCW 720 0 7 Y 29 7 0-FCV-032-0085-B AUX COMPR B.8 AUX BLDG ISOL 032 [AUXiUARY 734 (ACA) '"0 32 30 7 2-FCV-067-0176-A S.I. PUMP AND RM CLR-30-i80 SUPPLY 067 [AUXILIARY 669 0 43 31 7 2-FCV-067-0182-B S.h PUMP AND RM CLR-30-179 SUPPLY 067 AUXILIARY 669 0 43 32 7 2-FCV-067-0190-B RHR PUMP AM CLR-30-176 SUPPLY CONTROL VLV 067 AUXILIARY 653 ' 0 25 33 7 2-FCV-067-188 RHR PUMP RM CLR.30-17S SUPPLY CONTROL VLV 067 AUXILIARY 653 0 25 34 7 2-LCV-070-0063 SURGE TANK DEMIN W INLET VLV 070 AUXIUARY 734 (RCA) 0 32 3S 8 0-FCV-070-0040-9 SFPCS HTX A INLET FCV O-FCV-70-40 070 AUXtUARY 714 ,4 29 36 8 2-FCV-003-0126A-B ERCW HOR 8 ISOL VLV 003 AUXILIARY 690 4 38 37 8 2-FCV-067-0066 EMERG DSL HTXS AI&A2 SUP VLV FROM HOR A 067 DIESEL GEN. 722 0 1 38 8 2-FCV-067-0067 EMERG DSL HTXS B1&82 SUP VLV FROM HDR A 067 DIESEL GEN. 722 0 4- .39 8 2-FCV-067-0068 EMERG OSL HTX5 A1&A2 SUP VLV FROM HDR B 067 DIESEL GEN. 722 0 1 1 40 8 2-FCV-067-0492 ISOL VALVE 067 ERCW 688 0 9 41 9 :2-FAN-030-04S0-B D-G RM 28-B EXHAUST FAN 1 030 DIESEL GEN. 740 5 ' 6 Y Safety Function(s):

0 -Support Function 1 -Reactivity Control 2 -RCS Pressure Control 3 -RCS Inventory Control 4 -Decay Heat Removal 5 -ContaInment Isolation Page 91 of 444 Risk New or 5 Safety Enhanced Area Anchorage Item # Class UNID Description System Building Elevation Significant Replaced Functions for IPEEE Walkby Verification 42 9 2-FAN-030-0452 D-G RM 2A-A EXHAUST FAN 2 030 DIESEL GEN. 740 5 3 Y 43 9 2-FAN-030-0460 DIESEL GEN 2A-A ELECT BD ROOM EXHAUST 030 DIESEL GEN. 740 5 3 Y 44 9 2-FAN-030-0462-B DIESEL GEN 2B-B ELECT BD ROOM EXHAUST 030 DIESEL GEN. 740 V 5 6 Y 45 10 0-AHU-311-0023 MAIN CONTROL ROOM AHU B-B 311 CONTROL 732 Y 0 Y 12 46 10 2-AHU-313-0488 480V BD RM 2A SUPPLY AHU 2A-A 313 AUXILIARY 749 0 24 47 10 2-CLR-030-0178 CONTAINMENT SPRAY PUMP COOLER 2B-B 030 AUXILIARY 653 5 44 48 10 2-CLR-030-180-A SIS PUMP COOLER 2A-A 030 AUXILIARY 669 5 26 49 11 0-CHR-311-0126 MAIN CONTROL ROOM CHILLER PKG A-A 311 CONTROL 732 0 12 Y 50 11 0-CHR-311-0171 ELEC. BD. ROOM CHILLER PKG. B-B 311 CONTROL 669 0 37 Y 51 11 0-CHR-313-0338 SHUTDOWN BD RMS A & B WATER CHILLER PKG B-B 313 AUXILIARY 714 0 40 52 11 2-CHR-313-0483 480V ELECT BOARD RM 2A-A 313 AUXILIARY 749 0 24 53 12 0-CMP-032-0086-B AUX CONTROL AIR COMPRESSOR B-B 032 AUXILIARY 734 (RCA) Y 0 32 54 12 2-CMP-082-0240 DSL 2A1 STARTING AIR COMPRESSER 25.5 CFM 082 DIESEL GEN. 722 0 1 Y 55 12 2-CMP-082-0241 DSL 2A2 STARTING AIR COMPRESSOR 25.5 CFM 082 DIESEL GEN. 722 0 1 Y 56 12 2-CMP-082-0271 DSL 2B2 STARTING AIR COMPRESSER 25.5 CFM 082 DIESEL GEN. 722 0 4 Y 57 13 2-GEND-085-DG 4D,CONTROL ROD DRIVE GENERATOR 2A 085 AUXILIARY 759 0 30 Y 58 13 2-GEND-085-DH 3B,CONTROL ROD DRIVE GENERATOR 2B 085 AUXILIARY 759 0 30 Y 59 14 0-XSW-250-KL-S SPARE 480 V AC VITAL TRANSFER SW 2-S 250 AUXILIARY 749 0 22 Y 60 14 0-XSW-250-KX-S 125VDC CHGR 2-S DC XFER SW TO VBB III 250 AUXILIARY 749 0 22 Y 61 14 2-BDE-250-NF-E 120V AC VITAL INSTR POWER BD 2-11 250 AUXILIARY 734 Y 0 14 62 14 2-BDE-250-NK-G 120V AC VITAL INSTR POWER BD 2-IV 250 AUXILIARY 734 Y 0 45 63 14 2-PNLA-082-TV-A DG 2A-A 125 VOLT DC DISTRIBUTION PNL 082 DIESEL GEN. 722 0 1 64 14 2-XSW-082-UH-A DG 2A-A 480V TRANSFER SWITCH 082 DIESEL GEN. 722 0 1 65 15 O-BATB-250-QX-F 125V Vital Battery Room III Batteries 1-20 Rack 250 AUXILIARY 749 0 20 Y 66 15 0-BATB-250-QX-F 125V Vital Battery Room III Batteries 41-60 Rack 250 AUXILIARY 749 0 20 Y 67 15 O-BATB-250-QX-F 125V Vital Battery Room III Batteries 21-40 Rack 250 AUXILIARY 749 0 20 Y 68 15 0-BATB-250-QY-G 125V Vital Battery Room IV Batteries 1-20 Rack 250 AUXILIARY 749 0 21 Y 69 15 0-BATB-250-QY-G 125V Vital Battery Room IV Batteries 21-40 Rack 250 AUXILIARY 749 0 21 Y 70 15 0-BATB-250-QY-G 125V Vital Battery Room IV Batteries 41-60 Rack 250 AUXILIARY 749 0 21 Y 71 15 2-BATB-082-UD-A Diesel Gen. 2A-A Battery Rack 082 DIESEL GEN. 722 0 1 Y 72 16 O-CHGB-250-CJ-G 125V DC VITAL BATTERY CHARGER IV 250 AUXILIARY 749 Y 0 Y 22 73 16 O-CHGB-250-QK-S 125V DC VITAL BATTERY CHARGER 2-SPARE 250 AUXILIARY 749 0 Y 22 Y 74 16 2-CHGB-082-TZ DG 2A-A BATTERY CHARGER 082 DIESEL GEN. 722 0 1 75 16 2-CHGB-082-UA-B D/G 2B-B BATTERY CHGR 082 DIESEL GEN. 722 0 4 76 16 2-INVB-250-QU-G 120V AC VITAL INVERTER 2-IV 250 AUXILIARY 749 Y Y 0 Y 22 Y 77 17 2-ENG-082-0002A1 ENG 2A1 082 DIESEL GEN. 722 0 1 Y 78 17 2-ENG-082-0002A2 ENG 2A2 082 DIESEL GEN. 722 0 1 Y 79 17 2-ENG-082-0002B1 DIESEL ENGINE 281 082 DIESEL GEN. 722 0 4 Y 80 17 2-ENG-082-0002B2 DIESEL ENGINE 282 082 DIESEL GEN. 722 0 4 Y 81 17 2-GENB-082-0002A DIESEL GEN. 2A-A 082 DIESEL GEN. 722 0 1 Y 82 17 2-GENB-082-0002B DIESEL GEN. 28-B 082 DIESEL GEN. 722 0 4 Y 83 18 0-LOCL-500-0428 FLOOR PANEL AUXILIARY BUILDING 500 AUXILIARY 734 (RCA) 0 32 1 84 18 2-LOCL-500-0005 FLOOR PANEL AUXILIARY BUILDING 500 AUXILIARY 653 0 + 25 Safety Function(s): 0 -Support Function 1 -Reactivity Control 2 -RCS Pressure Control 3 -RCS Inventory Control 4 -Decay Heat Removal 5 -Containment Isolation Page 92 of 444 Risk New or S Safety Enhanced Area Anchorage Item # Class UNID Description System Building Elevation Significant Replaced Functions for IPEEE Walkby Verification 85 18 2-LOCL-500-0019 FLOOR PANEL AUXILIARY BUILDING 500 AUXILIARY 734 (RCA) 0 32 86 18 2-LOCL-500-0048 FLOOR PANEL AUXILIARY BUILDING 500 AUXILIARY 690 0 27 87 18 2-LOCL-500-0163 FLOOR PANEL DGB 500 DIESEL GEN. 722 0 4 88 18 2-LOCL-500-0222B FLOOR PANEL AUXILIARY BUILDING 500 AUXILIARY 690 0 38 89 19 2-TE-300-045OA-B DIESEL GEN 2B-B EXHAUST-HIGH TEMP 300 DIESEL GEN. 740 2,4 6 90 19 2-TE-300-045OB-B DIESEL GEN 2B-B EXHAUST-LOWTEMP 300 DIESEL GEN. 740 2,4 6 91 19 2-TE-300-0452A-A DIESEL GEN 2A-A EXHAUST-HIGH TEMP 300 DIESEL GEN. 740 2,4 3 92 19 2-TE-300-0452B-A DIESEL GEN 2A-A EXHAUST-LOW TEMP 300 DIESEL GEN. 740 2,4 3 93 19 2-TS-001-0018A-B STM FLOW TO AFPT ISOL -HIGH TEMP 001 AUXILIARY 669 0 34 94 19 2-TS-001-0018B-B STM FLOW TO AFPT ISOL -HIGH TEMP 001 AUXILIARY 669 0 34 95 20 0-LOCL-500-MO26D DIESEL GEN CONT 500 CONTROL 732 0 13 Y 96 20 2-LOCL-500-MO02 TURB CONTROL 500 CONTROL 732 0 13 Y 97 20 2-LOCL-500-MO04 Reactor Control Panel 2-M-4 500 CONTROL 732 0 13 Y 98 20 2-LOCL-500-MO08 TURB SUP CONT 500 CONTROL 732 0 13 99 20 2-LOCL-500-MO09 VENT-ICE CONT-REACT BD 500 CONTROL 732 0 13 Y 100 20 2-PNLA-082-TV /3-A DG 2A-A CONTROL PNL 082 DIESEL GEN. 722 0 1 101 See SWEL 2for Item 101.102 21 2-HEX-072-0007 CNTMT SPRAY HT EXCH 2B 072 AUXILIARY 690 5 39 Y 103 21 2-HEX-072-0030 CONTAINMENT SPRAY HEAT EXCHANGER 2A 072 AUXILIARY 690 5 42 Y 104 21 2-HEX-074-0015 RESIDUAL HEAT EXCHANGER 2A 074 AUXILIARY 690 Y 1,3,4 Y 42 Y 105 21 2-HEX-074-0027 RESIDUAL HEAT EXCHANGER 2B 074 AUXILIARY 690 Y 1,3,4 Y 39 Y 106 21 2-TNK-070-0063 CCS SURGE TANK B 070 AUXILIARY 734 (RCA) Y 0 32 Y 107 21 2-TNK-082-0224 DSL 2A1 STARTING AIR TANK A 35 CF 082 DIESEL GEN. 722 0 1 Y 108 21 2-TNK-082-0255 DSL 2B2 STARTING AIR TANK A 35 CF 082 DIESEL GEN. 722 0 4 Y 109 7 2-FCV-063-0090 SIS ACCUM TK 3 FLOW ISOLATION VLV 063 REACTOR 693 5 46 110 8 2-PSV-001-0013B-B SG 2 MAIN STM HDR PRESS 001 REACTOR 747 2,3 50 111 8 2-PSV-001-0024A-A SG 3 MAIN STM HDR PRESS 001 REACTOR 747 2,3 50 112 8 2-FCV-063-0118 SIS ACCUM TK 1 FLOW ISOLATION VLV 063 REACTOR 693 3 48 113 10 2-AHU-030-0080 CONTROL ROD DRIVE COOLING UNIT D-B 030 REACTOR 680 5 51 114 10 2-AHU-030-0088 CONTROL ROD DRIVE COOLING UNIT C-A 030 REACTOR 680 5 51 115 10 2-AHU-313-0262 INCORE INSTR RM AHU A 313 REACTOR 708 0 52 116 10 2-CLR-030-0074 REACTOR LOWER COMPT COOLING UNIT A-A 030 REACTOR 693 5 47 117 18 2-LOCL-500-0183C FLOOR PANEL REACTOR BUILDING 500 REACTOR 693 0 47 118 21 2-TNK-063-0060 SIS ACCUMULATOR NO 4 063 REACTOR 693 1,3 49 119 21 2-TNK-063-0119 SIS ACCUMULATOR NO 1 063 REACTOR 693 1,3 48 Safety Function(s): 0 -Support Function 1 -Reactivity Control 2 -RCS Pressure Control 3 -RCS Inventory Control 4 -Decay Heat Removal 5 -Containment Isolation Page 93 of 444 Sequoyah Unit 2 Seismic Walkdown Equipment List 2 Created By: for* -Approved By: Risk New or 5 Safety Enhanced for Area Anchorage Item # Class UNID Description System Building Elevation Significant Replaced Functions IPEEE Walkby Verification 20 5 0-PMP-078-0012-A SPENTFUELPITPUMPA 078 .AUXILIARY 714 0 28 101 21 0-HEX-078-0018 SPENT FUEL PIT HEAT EXCHANGER A 078 AUXILIARY 714 4 29 Y Safety Function(s): 0 -Support Function 1 -Reactivity Control 2 -RCS Pressure Control 3 -RCS Inventory Control 4 -Decay Heat Removal 5 -Containment Isolation Page 94 of 444 Sequoyah Unit 2 Area Walk-Bys Area Building Elevation Description 1 Diesel Gen 722 Bay 2A 2 Diesel Gen 740 2A Bd Rm 3 Diesel Gen 740 2A Fan Rm 4 Diesel Gen 722 Bay 2B 5 Diesel Gen 740 2B Bd Rm 6 Diesel Gen 740 2B Fan Rm 7 ERCW Pump 720 2A Pump Rm 8 ERCW Pump 704 2A Bd Rm 9 ERCW Pump 688 2A Strainer Rm 10 ERCW Pump 720 2B Pump Rm 11 ERCW Pump 704 2B Bd Rm 12 Control 732 Cont. IMech. Eqpt. Room 13 Control 732 Control Room Unit 2 14 Auxiliary 734 125V Batt Bd Room II 15 Auxiliary 734 480V Shtdwn Bd Rm 2A2 16 Auxiliary 734 480V Shtdwn Bd Rm 2B1 17 Auxiliary 734 480V Shtdwn Bd Rm 2B2 18 Auxiliary 749 480V XFMR Rm 2B 19 Auxiliary 749 480V XFMR Rm 2A 20 Auxiliary 749 125V Batt Rm III 21 Auxiliary 749 125V Batt Rm IV 22 Auxiliary 749 480V Bd Rm 2B 23 Auxiliary 749 480V Bd Rm 2A 24 Auxiliary 749 480V 2A Mech Eq Room 25 Auxiliary 653 RHR Pump Area 26 Auxiliary 669 SI Pump Rm 2A 27 Auxiliary 690 CCS Pump Area 28 Auxiliary 714 SFP Pit 29 Auxiliary 714 SFP HEX Area 30 Auxiliary 759 CRDM Room 31 Auxiliary 734 6.9kV Shtdwn Bd Rm A 32 Auxiliary 734 Surge Tnk B Area Area 33 Omitted 34 Auxiliary 669 Aux Feedwtr Pmp 2A-S 35 Auxiliary 669 Chg. Pump Rm 2B 36 Auxiliary 734 6.9kV Shtdwn Bd Rm B 37 Control 669 669 Mech Room 38 Auxiliary 690 Aux Feedwtr Pmp B Area 39 Auxiliary 690 2B RHR CCS HEX Room 40 Auxiliary 714 Shtdwn Bd B Area Area 41 Omitted 42 Auxiliary 690 2A RHR CCS HEX Room 43 Auxiliary 669 SI Pump Area 44 Auxiliary 653 CS Pump Room 2B 45 Auxiliary 734 125V Batt Bd Room IV Page 95 of 444 Sequoyah Unit 2 Area Walk-Bys Area Building Elevation Description 46 Reactor 693 Accum. Rm 3 47 Reactor 693 Fan Room 1 48 Reactor 693 Accum. Rm 1 49 Reactor 693 Accum. Rm 4 50 Reactor 747 Annulus AZ 277 51 Reactor 680 Inside Polar Crane Wall 52 Reactor 708 Incore Inst Room Platform Page 96 of 444 Appendix E: SWCs The following signatures are provided for the engineers responsible for the Seismic Walkdown Checklists in Sequoyah Unit 2.Name Signsture Date Isaac Antanaitis James Edgar I,.Robert Malone /Steven Summers f//Il lit-.Phillip York 4i I1-12-7012 Page 97 of 444 Status: YCK NEI UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-DRYA-032-0002-B Equip. Class 3 0 -Other (Dryer)Equipment Description AUX CONTROL AIR DRYER B-B Location: Bldg. Aux Floor El. 734 Room, Area 32 -Surge Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE] NM of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YM NE UE N/AE-YN NE UE] N/AE]4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE] N/AEl 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE] NEI UE1 N/AZ YN NEI UE1 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 98 of 444 Equipment ID No. SQN-ON-ROYA-032-0002-B Eq l0tD Equip. ClasS3 0 -Other (Dryer)Equipment Description AUX CONTROL AIR DRYER B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YCK NEI UE[ N/AE[8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N 0 UE0 N/A--and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI Ur--n N/AE YC1NOn U0 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y[Z NEr Urn adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phi/lip York Date: 8/8/12 8/8/12 Page 99 of 444 St.t.u: YN NO UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-201-FL-A Equip. Class 3 1 -MCC Equipment Description 480V ERCW MCC 2A-A Location: Bldg. ERCW Floor El. 704 Room, Area 8 -2A Board Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[E1 NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front panels could not be opened due to sensitive equipment that is utilized in all modes of operation.

Front kick-plates and back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NEI UE- N/AE3 YM NEI UE N/A[E Y19 NEI UE] N/AE YE1 NEI UEI N/AN YM NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 100 of 444 Equipment ID No. SQN-2-BDC-201-FL-A MCC Equip. ClasS3 1 -MCC Equipment Description 480V ERCW MCC 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[Z N[E UE] N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y N Nr- UrE- N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y M N E U1 N/ArE YZ NO UE7 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y C NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/19/12 Phillio York 7/19/12 Page 101 of 444 Status: YM NE UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-201-FN-B Equip. Class 3 1 -MCC Equipment Description 480V ERCW MCC 2B-B Location: Bldg. ERCW Floor El. 704 Room, Area 11 -2B Board Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y El N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front panels could not be opened due to sensitive equipment that is utilized in all modes of operation.

Front kick-plates and back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification, is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NE UO N/AE YN NEI UE[ N/AE YN NEI UE- N/AE YE NEI UE N/AN YER NEI UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 102 of 444 Equipment ID No. SQN-2-BDC-201-FN-B Equip. ClasS3 1 -MCC Equipment Description 480V ERCW MCC 28-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ1 NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YIZ NO U- N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UE N/A-NEI UEr Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/24/12 PhillD York 7/24/12 Page 103 of 444 St-t.t: YY NI- U-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-201-FQ-A Equip. Class 3 1 -MCC Equipment Description 480V DIESEL AUXILIARY BOARD 2A 1-A Location: Bldg. DG Floor El. 740 Room, Area 2 -2A Board Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraite

1. Is the anchorage configuration verification required (i.e., is the item one Y N NEI of the 50% of SWEL items requiring such verification)?

For anchorage configuration verification see calculation SCG-4M-00169, pages 17, 18A, 18B, and 18C.2. Is the anchorage free of bent, broken, missing or loose hardware?Front kick-plates were removed and anchorage to structure was verified Front panels could not be opened due to sensitive equipment that is utilized in all modes of operation. Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI U- N/AE YN NEI UE N/AE-YZ NE UE N/AE-YN NEI UE[ N/A[E YN NEI U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 104 of 444 Equipment ID No. SQN-2-BDC-201-FQ-A Equip. ClasS3 I -MCC Equipment Description 480V DIESEL AUXILIARY BOARD 2A 1-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Conduit from top of cabinet has minimum clear distance to cable trays.Licensing evaluation shows that seismic event would cause a movement of one-half inches. Not credible.8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment? Masonrv block wall behind cabinet seismically qualified in calculation SCG-1-86.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Yr NO UE N/AE YM NO UEr N/AE YN NEI UEr N/AE]Yr NEI Ur Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NO UE1 adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/18/12 Phillip York 7/18/12 Page 105 of 444 S t atus: :YZNEIUE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-201-FU-B Equip. Class 3 1 -MCC Equipment Description 480V DIESEL AUXILIARY BOARD 2B1-B Location: Bldg. DG Floor El. 740 Room, Area 5 -2B Board Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YEI of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front kick-plates were removed and anchorage to structure was verified.

Front panels could not be opened due to sensitive equipment that is utilized in all modes of operation. Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YlK NE UE N/AE YC NEI UE] N/AE Y[ NEI UE YE[ NEI UE[ N/AM YCK NEO UE[3 Enter the equipment class name from Appendix B: Classes of Equipment Page 106 of 444 Equipment ID No. SQN-2-BDC-201-FU-B Equip. ClasS3 I -MCC Equipment Description 480V DIESEL AUXILIARY BOARD 2B1-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YS[NE7 UE7 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[ NE] UE] N/A[]and masonry block walls not likely to collapse onto the equipment? Masonry block wall behind cabinet seismically qualified in calculation SCG-1-86.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE YM NE UE[Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y C NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/24/12 7/24/12 Page 107 of 444 St.t : Ytt Nus U-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-20 1-GM-A Equip. Class 3 1 -MCC Equipment Description 480V REACTOR MOV BO 2A2-A Location: Bldg. Aux Floor El. 749 Room, Area 23 -480V Board Room 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorame 1. Is the anchorage configuration verification required (i.e., is the item one Y[:] NrM of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?

Front kick-plates were removed and anchorage to structure was verified Front panels could not be opened due to sensitive equipment that is utilized in all modes of operation. Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y[ NEI UO N/AE[Y[ NE UE] N/AE YM NEI UE] N/A[-]YE NE UE] N/AL]YMNEUE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 108 of 444 Equipment ID No. SQN-2-BDC-20 1-GM-A Eqi.Cls212 Equip. ClasS3 I -MCC Equipment Description 480V REACTOR MOV BD 2A2-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Floor fan is chained improperly to conduit support near cabinet.During a seismic event fan could hit cabinet.YO NM UEr N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NE UE0 N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NE UE N/AE YZ NE UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YCK NE UE'adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/30/12 Phillib York 7/30/12 Page 109 of 444 .Status: YM NEI UE-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-201-GN-B Equip. Class 3 1 -MCC Equipment Description 480V REACTOR MOV BO 2B1-B Location: Bldg. Aux Floor El. 749 Room, Area 22 -480V Board Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NiZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front kick-plates were removed and anchorage to structure was verified Front panels could not be opened due to sensitive equipment that is utilized in all modes of operation.

Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistentwith plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE] N/AE YZ NEI UE[ N/AE YN NEI UE[ N/AE YEI NEI UE] N/AM YM NEI UE-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 110 of 444 Equipment ID No. SQN-2-BDC-20 1-GN-B EqV.Cls2B1 Equip. ClaSS3 I -MCC Equipment Description 480V REACTOR MOV BD 2B1-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NEl U E N/A E-and masonry block walls not likely to collapse onto the equipment? Masonry block wall seismically qualified in calculation SCGJ3OXJ 1.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NE UEV N/AE YN NEI UE1 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y IZ NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/26/12 James Ed~qar 7/26/12 Page 111 of 444 St.t.a: Y' NED UEU Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-201-JK-A Equip. Class 3 I -MCC Equipment Description 480V CONT & AUX BLDG VENT BD 2A2-A Location: Bldg. Aux Floor El. 734 Room, Area 15 -480V Shutdown Board Room 2A2 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE- NZ]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?

Front kick-plates were removed and anchorage to structure was verified Front panels could not be opened due to sensitive equipment that i's utilized in all modes of operation. Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y N E UE N/A El Y[ NEI UE N/AE1 YCK NE UE- N/AEl YE] NE UE1 N/AN YZ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 112 of 444 Equipment ID No. SQN-2-BDC-201-JK-A Equip. ClaSS3_ I -MCC Equipment Description 480V CONT & AUX BLDG VENT BD 2A2-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NE UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N[: U E] N/AED and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y* NE UE N/AE: Y* NI U E Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI UE[]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/30/12 Phillio York 7/30/12 Page 113 of 444 S t a t.: :YNNDEUE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDC-20 1-DO-A Equip. Class 3 2 -Low Voltage Equipment.Description 480V SHUTDOWN BD 2A2-A Location: Bldg. Aux Floor El. 734 Room, Area 15 -480V Shutdown Board Room 2A2 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one Y[] NCR of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?

Front panels could not be opened due to the excessive safety hazard of opening this shutdown board during any mode of operation. Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation? Y[ NEI UE] N/AE1 YZ NEI UE N/AD 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE1 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE- NE UE] N/AZ Y[NEIUE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 114 of 444 Equipment ID No. SQN-2-BDC-20 1-DO-A EiCs2L-A Equip. ClasS3 2 -Low Voltage Equipment Description 480V SHUTDOWN BD 2A2-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y 0 NEl UI- N/A E 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[] NEI UE] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YS NO UE N/AE Y[NDUE]Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/30/12 Phillip York 7/30/12 Page 115 of 444 St.t us: YZ NO UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDB-201-DP-B Equip. Class 3 2 -Low Voltage Switch-gear Equipment Description 480V SHUTDOWN BD 2B1.-B Location: Bldg. Aux Floor El. 734 Room, Area 16 -480V Shutdown Board Room 2B1 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YD NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?

Front panels could not be opened due to the excessive safet hazard of opening this shutdown board during any mode of operation. Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI UE- N/AE Y Z N[E UE] N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y Z N E] U E] N/A E]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE N/A[K YNNEUE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 116 of 444 Equipment ID No. SQN-2-BDB-2S1-DP-B E lL-h Equip. ClaSS3 2 -Low Voltage Switch-gear Equipment Description 480V SHUTDOWN BO 2B1-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE] UE] N/A[and masonry block walls not likely to collapse onto the equipment? Masonry block wall seismically qualified in calculation SCG130X11.

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE YM NEUE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/26/12 James Edaar 7/26/12 Page 117 of 444 Stat..s: YNE N u Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDB-201-DQ-B Equip. Class 3 2 -Low Voltaqe Switchqear Equipment Description 480V SHUTDOWN BD 2B2-B Location: Bldg. Aux Floor El. 734 Room, Area 17 -480V Shutdown Board Room 2B2 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWFEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Yr-- NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front panels could not be opened due to the excessive safet hazard of opening this shutdown board during any mode of operation.

Back panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NE UE N/AE YZ NE UEr N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AN YZ NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 118 of 444 Equipment ID No. SQN-2-B4B-2S1-DQ-B E lL-c Equip. ClasS3 2 -Low Volta-ge Switchgear Equipment Description 480V SHUTDOWN BD 2B2-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N E UrE N/AE0 and masonry block walls not likely to collapse onto the equipment? Masonry block wall seismically qualified in calculation SCG130X11.

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE[ N/AE1 YM NEI UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y X NEI U-adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/26/12 James Edaar 7/26/12 Page 119 of 444 S t a.t u: YM NE UE[Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDA-202-CO-A Equip. Class 3 3 -Medium Voltaqe Switch qear Equipment Description 6900V SHUTDOWN BOARD 2A-A Location: Bldg. Aux Floor El. 734 Room, Area 31 -6.9kV Shutdown Board Room A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YO NIZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front panels could not be opened due to the excessive safety hazard of opening this shutdown board during any mode of operation.

Back panels required extensive disassembly to open.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YER NEI UE] YCK NE UE1 N/AE YN NE UE N/AE Y[E NE] UE0 N/A[C YN NEI UE 3 Enter the equipment class name from Appehdix B: Classes of Equipment Page 120 of 444 Equipment ID No. SQN-2-BDA-202-CO-A Equip. Class 3 3 -Medium Voltage Switch-gear Equipment Description 6900 V SHUTDOWN BOARD 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[I N[I U E N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UEJ N/AE [and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE YM NEI UD Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YCK NE U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/3/12 PhilliD York 8/3/12 Page 121 of 444 S t-a-: Y[ NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDB-202-CP-B Equip. Class 3 3 -Medium Voltage Switch-gear Equipment Description 6900V SHUTDOWN BOARD 2B-B Location: Bldg. Aux Floor El. 734 Room, Area 36 -6.9kV Shutdown Board Room B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE7 NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?

Front panels could not be opened due to the excessive safety hazard of opening this shutdown board during any mode of operation. Back panels required extensive disassembly to open.3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI UE- N/AE]YCK NEI U3 N/AD 4. Is the anchorage free of visible cracks in the concrete near the anchors? YIZ NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE N/AZ YX NO UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 122 of 444 Equipment ID No. SQN-2-BDB-202-CP-B Equip. Class 3 3 -Medium Voltage Switch-gear Equipment Description 6900V SHUTDOWN BOARD 2B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Scaffolding in front of equipment needs additional restraint to prevent tipping into soft targets. Only one restraint point was used near the bottom on the assembly. During a seismic event, the scaffolding could overturn and strike the equipment. On a later inspection, it was found that the scaffolding had been anchored properly from the top of the assembly YZ NEI U[- N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE] UE] N/AD and masonry block walls not likely to collapse onto the equipment? Masonry block wall near equipment seismically qualified in calculation 46W405-5.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NE1 U0 N/A]YN NO UE Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y Z NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Appendix R work was being performed in the area at the same time the walkdown occurred.Temporary equipment was prevalent in the area. Proper storage for the equipment was verified.Evaluated by: Robert Malone Date: 8/7/12 Phillip York 8/7/12 & 8/23/12 8/23/12 Isaac Antanaitis Page 123 of 444 Status: NEI UEr Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-OXF-202-2A-A Equip. Class 3 4 -Transformer Equipment Description 480V SHUTDOWN TRANSFORMER 2A 1-A Location: Bldg. Aux 'Floor El. 749 Room, Area 19 -480V Transformer Room 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 7057025 and 48N1274 Mk 2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NEI UEr N/A--YN NE UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE YN NO UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 124 of 444 Equipment ID No. SQN-2-OXF-202-2A-A Equip. ClaSS3- 4 -Transformer Equipment Description 480V SHUTDOWN TRANSFORMER 2A 1-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI UEI N/AEI 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YO NM1 UE N/AE and masonry block walls not likely to collapse onto the equipment? Masonry block wall seismically qualified in drawing 46 W405- 7,9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE YE NEI UE7 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y N NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/30/12 Phillip York 7/30/12 Page 125 of 444 Status: Y[] NE UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-OXF-202-2B-B Equip. Class 3 4 -Transformer Equipment Description SD XFMR 2B-B Location: Bldg. Aux Floor El. 749 Room, Area 18 -480V Transformer Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 7057025 and 48N1274 Mk 2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NEI UE N/AE YN NE UE N/AD 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE N/AE-1 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NE UE N/AE YN NO U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 126 of 444 Equipment ID No. SQN-2-OXF-202-2B-B Equip. ClasS3 4 -Transformer Equipment Description SD XFMR 28-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[ NrI UE] N/A E 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YM NO UE N/AE and masonry block walls not likely to collapse onto the equipment? Hairline cracks were observed and should be monitored Masonry block wall seismically qualified in drawing 46 W405- 7,9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y 0 NE': U E N/AE]Y[NDUE]Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YZ1 NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/26/12 James Edaar 7/26/12 Page 127 of 444 S t a t us: :YNNEIUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-OXF-202-DN-A Equip. Class 3 4 -Transformer Equipment Description 480V SHUTDOWN TRANSFORMER 2A-A Location: Bldg. Aux Floor El. 749 Room, Area 19 -480V Transformer Room 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walk:down of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YN NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 7057025 and 48N1274 Mk 2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? Y M NE[ U E N/AE-: YM NEI UE N/A-4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YC NE UE N/AE YER NEI U7 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 128 of 444 Equipment ID No. SQN-2-OXF-202-DN-A Equip. ClasS3 4 -Transformer Equipment Description 480V SHUTDOWN TRANSFORMER 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NE UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ Nr Ur N/AE and masonry block walls not likely to collapse onto the equipment? Hairline cracks were observed and should be monitored Dwg 46W405-8 confirms use of same size rebar throughout the length of wall. Masonry block wall seismically qualified in drawing 46W,105-7,9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YED NE UE1 N/AE YN NEI UO Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y Z NEI U E[adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/30/12 Phillit York 7/30/12 Page 129 of 444 Stat-s: YY NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-OXF-202-DQ-B Equip. Class 3 4 -Transformer Equipment Description SD XFMR 202-B Location: Bldg. Aux Floor El. 749 Room, Area 18 -480V Transformer Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y -Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 7057025 and 48N1274 Mk 2.2. Is the anchorage free of bent, broken, missing or loose hardware'?

3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y[] NEI UE N/AE7 Y[ NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZI NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE N/AE[YX NE UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 130 of 444 Equipment ID No. SQN-2-OXF-202-DQ-B Equipment Description SD XFMR 2B2-B Equip. Class 3 4 -Transformer Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NO UO N/A[8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y] NEI U- N/Al and masonry block walls not likely to collapse onto the equipment? Hairline cracks were observed and should be monitored. Masonn'block wall seismically qualified in drawing 46W405-7,9.

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI Ur N/AO YCK NO Ur Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y I] NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/26/12 James Ed-gar 7/26/12 Page 131 of 444

  • S.t.t: Y NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-XFA-202-0312 Equip. Class 3 4 -Transformer Equipment Description ERCW TRANSFORMER 2A-A Location:

Bldg. ERCW Floor El. 704 Room, Area 8 -2A Board Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y [ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 35 W312 Section A-A and 33N334 Section G-G.2. Is the anchorage free of bent, broken, missing or loose hardware'?

3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NEI UE N/AE1 YEK NEI UE] N/AO 4. Is the anchorage free of visible cracks in the concrete near the anchors? YM NEI UE N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YM NE UE- N/AE-YN NO U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 132 of 444 Equipment ID No. SQN-2-XFAN-202-0312 E l Equip. ClasS3 4 -Transformer Equipment Description ERCW TRANSFORMER 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NO UE:1 N/AEI 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YED NEI UE: N/AE YCK NEI UE" Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NO U E]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/19/12 Phillip York 7/19/12 Page 133 of 444 Status: YR NE-I UEV Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-XFA-202-0316 Equip. Class 3 4 -Transformer Equipment Description ERCW TRANSFORMER 28-B Location: Bldg. ERCW Floor El. 704 Room, Area 11 -2B Board Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing. Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the$WEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one Y[ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 35 W312 Section A-A and 33N334 Section G-G.2. Is the anchorage free of bent, broken, missing or loose hardware'?

3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y[ NE UE7 N/AE YN NEI UE] N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y N NEI U N/A E 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YM NEI UE[ N/AE1 Y[NEIUE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 134 of 444 Equipment ID No. SQN-2-XFA-202-0316 E C 4 n Equip. ClasS3 4 -Transformer Equipment Description ERCW TRANSFORMER 2B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI U-1 N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YM NEI UE1 N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE YN NE U'Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NE UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/24/12 Phillin York 7/24/12 Page 135 of 444 Status: YO NEI UEJ Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-PMP-078-0012-A Equip. Class 3 5 -Horizontal Pump Equipment Description SPENT FUEL PIT PUMP A Location: Bldg. Aux Floor El. 714 Room, Area 28 -Spent Fuel Pool Pit Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YEI NO of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y Z NE: UE N/AE YO NEI UE] N/AE!YN NEI UE] N/AE YE- NEI UE] N/AO YZ NE UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 136 of 444 Equipment ID No. SQN-0-PMP-0 78-0012-A E .s -Equip. ClaSS3 5 -Horizontal Pump Equipment Description SPENT FUEL PIT PUMP A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NCI UE: N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[Z NrE U E N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE[ N/Ar YM NEI UEr Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/2/12 Phillip York 8/2/12 Page 137 of 444 YX NEI UEI Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PMP-003-0128 Equip. Class 3 5 -Horizontal Pump Equipment Description MOTOR DRIVEN AUX FEEDWATER PUMP 2B-B Location: Bldg. Aux Floor El. 690 Room, Area 38 -Aux Feedwater Pump B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one Y[ NE]of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing C-55HMTA86X22-B

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YM NEI UE] N/AE Y[] NE] U E N/A1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEJ UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y 0 NEl U E- N/A E YZ NO UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 138 of 444 Equipment ID No. SQN-2-PMP-003-0128 Equip. ClasS3 5 -Horizontal Pump Equipment Description MOTOR DRIVEN AUX FEEDWA TER PUMP 2B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[] Nr--E UrE N/AD and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE N/AE-YM NO UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NE U E]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/7/12 Phillip York 8/7/12 Page 139 of 444 S t a t..: :YNNEIUE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PMP-062-0104 Equip. Class 3 5 -Horizontal Pump Equipment Description CENT CHARGING PUMP 2B-B Location: Bldg. Aux Floor El. 669 Roo m, Area 35 -Charging Pump Room 2B-B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YN NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing ISI-0476-C-01.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UE N/AE YN NEI UE] N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE[ N/AEl YN NEI U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 140 of 444 Equipment ID No. SQN-2-PMP-062-0104eEquip.ionC Equip. ClaSS3 Horizontal Pump Equipment Description CENT. CHARGING PUMP 2B-2 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NO UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NE UE N/ArE and masonry block walls not likely to collapse onto the equipment? A block wall used for equipment removal was near the equipment. It is restrained/reinforced with cross bars bolted to the concrete wall.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE1 N/A--YM NEI UE1 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Flex conduit into junction box has slipped back and exposed the wires going into the box.Evaluated by: Robert Malone Date: 8/6/12 Philli York 8/6/12 Page 141 of 444 Sta t us: :YZNEIUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PMP-063-O010 Equip. Class 3 5 -Horizontal Pump Equipment Description SAFETY INJECTION PUMP 2A-A Location: Bldg. Aux Floor El. 669 Room, Area 35 -SI Pump Room 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[R NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing ISI-04 76-C-01.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI UE N/AE]YZ NEI UE] N/A-4. Is the anchorage free of visible cracks in the concrete near the anchors? YM NEI UE[ N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YER NE UEr N/AE Y23 NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 142 of 444 Equipment ID No. SQN-2-PMP-063-EON1 EiCs5Hztu Equip. ClasS3 5 -Horizontal Pump Equipment Description SAFETY INJECTION PUMP 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YR NEI UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE N/AE and masonry block walls not likely to collapse onto the equipment? A block wall used for equipment removal was near the equipment. It is restrained/reinforced with cross bars bolted to the concrete wall.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI Ur N/AE Y[ NEI UEI Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YM NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Flex conduit into junction box has slipped back and exposed the wires going into the box.Evaluated by: Robert Malone Date: 8/6/12 Philipn York 8/6/12 Page 143 of 444 S t.a.u: YY NO U Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PMP-070-0059-A Equip. Class 3 5 -Horizontal Pump Equipment Description CCS PUMP 2A-A Location: Bldg. Aux Floor El. 690 Room, Area 27 -CCS Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing ISI-0260-C-01.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YM NE UE N/AE YN NO UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NO UE N/AE3 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NO UE N/AE1 YN NO UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 144 of 444 Equipment ID No. SQN-2-PMP-0 70-0059-A E Equip. ClaSS3 5 -HodzQt7tal Pump Equipment Description CCS PUMP 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NO UO N/A-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE N/AE[and masonry block walls not likely to collapse onto the equipment? There is a 10 '-12' "specialfire barrier" wall next to the equipment. It appears to be constructed of dry wall and cantilevered form the floor.During a seismic event, it was determined that the wall would not damage the equipment if it collapsed and is therefore not considered seismically significant.

9. Do attached lines have adequate flexibility to avoid damage? YZ NEI U0 N/Ar 10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YM N- U[E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/2/12 PhilliD York 8/2/12 Page 145 of 444 S t atus: YNNEIUE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-PMP-067-0452 Equip. Class 3 6 -Vertical Pump Equipment Description ERCW PUMP N-B Location: Bldg. ERCW Floor El. 720 Room, Area 10 -2B Pump Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorane 1. Is the anchorage configuration verification required (i.e., is the item one YNI N[]of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see TVA calculation CEB-CQS-373.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? Y 0 NEI U[E N/AE YN NEI UE] N/AE'4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE] N/AE[5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE[YM NEI UE-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 146 of 444 Equipment ID No. SQN-O-PMP-067-0452 Equip. ClasS3 6 -Vertical Pump Equipment Description ERCW PUMP N-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y Z N[E UD] N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N E- U E N/A ": and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[R NEI UE: N/AE-Y I NEl U[1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/24/12 7/24/12 Page 147 of 444 Stat.u: YN NO UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-PMP-067-0464 Equip. Class 3 6 -Vertical Pump Equipment Description ERCW PUMP R-A Location: Bldg. ERCW Floor El. 720 Room, Area 7 -2A Pump Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YIK NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see TVA calculation CEB-CQS-373.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NE UE N/AE YM NEI UE N/AE]YN NE UE N/AE YN NE UE N/AE YN NEI UO 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 148 of 444 Equipment ID No. SQN--PMP-067-0464 Equip. ClaSS3 6 -Vertical Pump Equipment Description ERCW PUMP R-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YCK NEI UO N/AE1 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI U[: N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UO N/AE YM NEIUE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/19/12 Phillio York 7/19/12 Page 149 of 444 St.a.t: YY NE U-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-PMP-067-0482-B Equip. Class 3 6 -Vertical Pump Equipment Description ERCW SCREEN WASH PUMP C-B Location: Bldg. ERCW Floor El. 720 Room, Area 10 -2B Pump Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y Z NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 31 W211-6, Section B6-B6.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NEI UE N/AE YN N- UE7 N/AO 4. Is the anchorage free of visible cracks in the concrete near the anchors? YIK NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yl NO UE N/AE YN NE Ur 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 150 of 444 Equipment ID No. SQN-O-PMP-067-0482-B E Equip. ClasS3_ 6 -Vertical Pump Equipment Description ERCW SCREEN WASH PUMP C-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI U[ N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ1 NEI UD N/AD[and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NEI UE[ N/AD1 YCKNEIUO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Cover to electrical box attached to equipment was not closed and caulk has pulled away from the electrical wire. Assembly is no longer watertight. Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/24/12 Phillip York 7/24/12 Page 151 of 444 Status: YN NEI UEr Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-PMP-067-048 7-A Equip. Class 3 6 -Vertical Pump Equipment Description ERCW SCREEN WASH PUMP D-A Location: Bldg. ERCW Floor El. 720 Room, Area 7 -2A Pump Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraie 1. Is the anchorage configuration verification required (i.e., is the item one YN NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 31 W211-6, Section B6-B6.2. Is the anchorage free of bent, broken, missing or loose hardware'?

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Concrete edge distance/for rear bolts is reduced as compared to other edges. Embedment of bolts into concrete is an additional 12" below the pad, per drawing 31 W211-6, Section B6-B6, so reduced edge distance does not affect overall strength.3 Enter the equipment class name from Appendix B: Classes of Equipment YN NEI UE N/AE1 Y[ NO UEr N/AE[Y[1 NEI UE N/AE YM NEI UE] N/AE YZ NEI UE Page 152 of 444 Equipment ID No. SQN-E-PMP-067-0487-A EiMP-ecP Equip. ClasS3- 6 -Vertical Pump Equipment Description ERCW SCREEN WASH PUMP D-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ] NO U- N/A-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NF U El N/A 0 and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE[ N/AE YZ NEI UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M N El U El adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/19/12 Phillin York 7/19/12 Page 153 of 444 YNI NE UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-Q-FCV-032-0085-B Equip. Class 3 7- Pneumatic Valve Equipment Description AUX COMPR B-B AUX BLDG ISOL Location: Bldg. Aux Floor El. 734 Room, Area 32 -SurQe Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YE- NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE1 NEI UE1 N/AM YEI NEI UE] N/AM 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE) NEI UE] N/AN 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AZ YN NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 154 of 444 Equipment ID No. SQN-O-FCV-032-0085-B Equip. ClaSS3 7 -Pneumatic Valve_Equipment Description AUX COMPR B-B AUX BLDG ISOL Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI UO N/Am 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Yl NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YER NEI UE N/AE-YI NO-UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 Phillip, York 8/6/12 Page 155 of 444 S-t.a: Yus NEI UO Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-0176-A Equip. Class 3 7 -Pneumatic Valve Equipment Description S.I. PUMP AND RM CLR-30-180 SUPPLY Location: Bldg. Aux Floor El. 669 Room, Area 43 -SI Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE:] NZ]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y1E NEI UE- N/AM YE] NE UE] N/AM 4. Is the anchorage free of visible cracks in the concrete near the anchors? YEI NEI UE] N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE N E] UE N/A Z YZ NEI U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 156 of 444 Equipment ID No. SQN-2-FCV-067-. 176-A Equip. CLa Equip. ClaSS3 7 -Pneumatic Valve Equipment Description SI .PUMP AND RM CLR-30-180 SUPPLY Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI U- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YIZ N- UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UE N/AE YN NEI U7 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NE U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/1/12 PhiiD York 8/1112 Page 157 of 444 St.t.t: YY NEI UE-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-0182-B Equip. Class 3 7 -Pneumatic Valve Equipment Description S.!/. PUMP AND RM CLR-30-179 SUPPLY Location: Bldg. Aux Floor El. 669 Room, Area 43 -SI Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE7 NEI UE N/A'YE NE UE N/A[4. Is the anchorage free of visible cracks in the concrete near the anchors? Y El N El U E] N/A M 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE] N/AN YNNEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 158 of 444 Equipment ID No. SQN-2-FCV-067-O182-B q Equip. ClasS3- 7 -Pneumatic Valve Equipment Description S.lI. PUMP AND RM CLR-30-179 SUPPLY Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NO U- N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YCK NEI UE N/AE Y[K NEI UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NE U E[adversely affect the safety functions of the equipment?

Comments(Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/8/12 PhiiD York 8/8/12 Page 159 of 444 Stt..: Ytt NE UE[Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-0190-B Equip. Class 3 7 -Pneumatic Valve Equipment Description RHR PUMP RM CLR 176 SUPPLY CONTRIOL VL V Location: Bldg. Aux Floor El. 653 Room, Area 25 -RHR Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE- NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NEI UE] N/AZ YE NE UE] N/A[Z 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y E1 N El U E- N/A 1Z 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE1 N/AX YM NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 160 of 444 Equipment ID No. SQN-2-FCV-067-0190-B E Equip. ClasS3_ 7 -Pneumatic Valve Equipment Description RHR PUMP RM CLR-30-176 SUPPLY CONTROL VLV Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YER NEI UE[ N/AE1 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE] UEJ N/AEr and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE7 YN NO UEJ Other Adverse Conditions
11. Have you looked for and found no other seismic conditionsthat could YN NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 Phillip York 8/6/12 Page 161 of 444 Statu.: Ya NEI UiE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-188 Equip. Class 3 7 -Pneumatic Valve Equipment Description RHR PUMP RM CLR-30-175 SUPPLY CONTROL VLV Location: Bldg. Aux Floor El. 653 Room, Area 25 -RHR Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NEI UE N/AM YE NE UE N/AM 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE NE UE N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE N/AZ YZ NE U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 162 of 444 Equipment ID No. SQN-2-FCV-067-188 Equip. ClasS3_ 7 -Pneumatic Valve Equipment Description RHR PUMP RM CLR-30-1 75 SUPPLY CONTROL VLV Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NE UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y1 NEI UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE N/A[E YN NEI UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/1/12 Phillip York 8/1/12 Page 163 of 444 Statu.s: YN NEI UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LCV-070-0063 Equip. Class 3 7 -Pneumatic Valve Equipment Description SURGE TANK DEMIN W INLET VL V Location: Bldg. Aux Floor El. 734 Room, Area 32 -Surge Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y El N M of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YEI NEI UEI N/Az YEl NE U E- N/A1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE NEI UE N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage.

free of potentially adverse seismic conditions? YEI NE UE] N/AM YZ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 164 of 444 Equipment ID No. SQN-2-LCV-070-0063 Equip. ClasS3_ 7 -Pneumatic Valve Equipment Description SURGE TANK DEMIN W INLET VLV Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Storage cabinet chained and wheels locked.YM NO UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE N/AEI and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE] N/AE-Y[ NEI UE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/3/12 Phillinp York 8/3/12 Page 165 of 444 S t a t.s: YN NEI UE3 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-FCV-070-0040-B Equip. Class 3 8 -Motor Valve Equipment Description SFPCS HTX A INLET FCV 0-FCV-70-40 Location: Bldg. Aux Floor El. 714 Room, Area 29 -Spent Fuel Pool Heat ExchanQer Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE N[]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NEI UE N/AN YE NE UE N/AN 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE NE UE N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE-- N/AM YN NE U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 166 of 444 Equipment ID No. SQN-F-FCV-070-0040-B Equip.AINLET8C Equip. Class3_ 8 -Motor Valve Equipment Description SFPCS HTX A INLET FCV 0-FCV-70-40 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM ND UD N/A--8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YIZ NDI UD- N/ADJ and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM ND UD N/AD YX NE UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI UDI adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/2/12 PhiliiD York 8/2/12 Page 167 of 444 Stat.s: YM NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-003-0126A-B Equip. Class 3 8 -Motor Valve Equipment Description ERCW HDR B ISOL VL V Location: Bldg. Aux Floor El. 690 Room, Area 38 -Aux Feedwater Pump B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y El N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE1 NEI UE N/AE YEI NE UE1 N/AN 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE1 NEI UE N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE: NE] UE- N/A 0 YCK NE UE-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 168 of 444 Equipment ID No. SQN-2-FCV-003-0126A-B Eqi Equip. ClasS3_ 8 -Motor Valve Equipment Description ERCW HOR B ISOL VL V Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[1 NEI UrE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE-YN NEI UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 8/7/12 8/7/12 Page 169 of 444 YY N]E U0 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-0066 Equip. Class 3 8 -Motor Valve Equipment Description EMERG DSL HTXS A1&A2 SUP VLV FROM HDR A Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Rotork Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? YE NM 2. Is the anchorage free of bent, broken, missing or loose hardware'?

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE7 NE UE N/AD9 YE NEI UE N/ACK YE NE UE N/AM YEI NE UE N/A[YZ NEUI uE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 170 of 444 Equipment ID No. SQN-2-FCV-067-0066 Equip. ClasS3 8 -Motor Valve Equipment Description EMERG DSL HTXS A1&A2 SUP VLV FROM HDR A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YX NEI UEr N/AE[8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[1 NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE[YCK NEI UE]Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NED U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/16/12 Phillip York 7/16/12 Page 171 of 444 St.: Ytt NEI UEr Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-0067 Equip. Class 3 8 -Motor Valve Equipment Description EMERG DSL HTXS BI&B2 SUP VLV FROM FDR B Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Rotork Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one Y El N X of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NEI UE[ N/AN YE1 NEI UE3 N/AN 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y El N El U El N/A 9 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AN YZ NEI U[E 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 172 of 444 Equipment ID No. SQN-2-FCV-067-0067 Equip. ClaSS3 8 -Motor Valve Equipment Description EMERG DSL HTXS B1&B2 SUP VLV FROM FOR B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NE UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YI NE- UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/A[]YN NEI U[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NO U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/23/12 7/23/12 Page 173 of 444 S tatus: YN NO U17 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-067-0068 Equip. Class 3 8 -Motor Valve Equipment Description EMERG DSL HTXS AI&A2 SUP VLV FROM HDR B Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NE UE1 N/AZ YE[ NE U- N/AM 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE NE UE N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AN Y[K NO U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 174 of 444 Equipment ID No. SQN-2-FCV-067-0068 Equip. ClaSS3 8 -Motor Valve Equipment Description EMERG DSL H7XS A1&A2 SUP VLV FROM HDR B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[] N E- UE] N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Yr NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NO UE[ N/AEq YN NEI UEr Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y E NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/17/12 Phillip York 7/17/12 Page 175 of 444 Status: Y] NEI UE[Seismic Walkdown Checklist (SWC).Equipment ID No. SQN-2-FCV-067-0492 Equip. Class 3 8 -Motor Valve Equipment Description ISOL VALVE Location: Bldg. ERCW Floor El. 688 Room, Area 9 -2A Strainer Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the.SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YEI NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NEI UE N/AM YEI NEI UE N/AM 4. Is the anchorage free of visible cracks in the concrete near the anchors? YEI NEI UE N/AiR 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AM YCK NO UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 176 of 444 Equipment ID No. SQN-2-FCV-067-0492 Equip. ClaSS3 8 -Motor Valve Equipment Description ISOL VA.L VE Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N[ U E- N/A E and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?.10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE N/A--YZ NEI UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YZ NE U -adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/19/12 Phillio York 7/19/12 Page 177 of 444 S.t.as: YZ NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FAN-030-0450-B Equip. Class 3 9 -Fan Equipment Description D-G RM 2B-B EXHAUST FAN 1 Location: Bldg. DG Floor El. 740 Room, Area 6 -2B Fan Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YM NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawingl,2-10N320-3, Detail F3.2. Is the anchorage free of bent, broken, missing or loose hardware'?

3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UE[ N/AE YN NEI UE[ N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YM NE UE N/AE YONDUE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 178 of 444 Equipment ID No. SQN-2-FAN-030-0450-B E Equip. ClaSS3_ 9 -Fan Equipment Description D-G RM 2B-B EXHAUST FAN 1 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y Z NE UE N/AE]8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y 0 NE0 UE7 N/AE0 and masonry block walls not likely to collapse onto the equipment? Masonry block wall near equipment approved in calculation SCG-1-86.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE YE NEI UEr Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YZ NEI UO adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/24/12 Phillip York 7/24/12 Page 179 of 444 S t a t us: :YNNEIU11 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FAN-030-0452 Equip. Class 3 9 -Fan Equipment Description D-G RM 2A-A EXHAUST FAN 2 Location: Bldg. DG Floor El. 740 Room, Area 3 -2A Fan Rm Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YIX Nr--of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing],2-1 0N320-3, Detail F3.2. Is the anchorage free of bent, broken, missing or loose hardware?There is slight bending in 3 of 4 anchor bolts. This is not considered seismically significant.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI U11 N/AENE UE1 N/AE YZ NE UED N/AE1 YZ NO UE[ N/AL]YN NEI UEr 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 180 of 444 Equipment ID No. SQN-2-FAN-030-0452GEquip.-AEXH Equip. ClaSS3_ 9 -Fan Equipment Description D-G RM 2A-A EXHA US T FAN 2 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Yr NEI UE-1 N/AEr and masonry block walls not likely to collapse onto the equipment? Masonry block wall near equipment approved in calculation SCG-1-86.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NEI UE: N/AE YR NEI UE-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y C NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/18/12 PhilliD York 7/18/12 Page 181 of 444 S t 8.t.. 5 YNNEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FAN-030-0460 Equip. Class 3 9 -Fan Equipment Description DIESEL GEN 2A-A ELECT BD ROOM EXHAUST Location: Bldg. DG Floor El. 740 Room, Area 3 -2A Fan Rm Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing],2-1 0N320-3, Detail E3.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NE UE N/AE YCK NEI UE1 N/AE YZ NEI UE1 N/AE YN NE UE N/AE YZ NEI UE[3 Enter the equipment class name from Appendix B: Classes of Equipment Page 182 of 444 Equipment ID No. SQN-2-FAN-030-0460 Equip. ClaSS3_ 9 -Fan Equipment Description DIESEL GEN 2A-A ELECT BD ROOM EXHAUST Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NE UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N E U E N/A E and masonry block walls not likely to collapse onto the equipment? Masonry block wall near equipment approved in calculation SCG-1 -86.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE Y[K NE UE]Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could. YCK NO UE [adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/18/12 Phillio York 7/18/12 Page 183 of 444 Status: YX NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FAN-030-0462-B Equip. Class 3.9 -Fan Equipment Description DIESEL GEN 2B-B ELECT BD ROOM EXHAUST Location: Bldg. DG Floor El. 740 Room, Area 6 -2B Fan Rm Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YN NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawingl, 2-10N320-3, Detail E3.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NE UE N/AE YN NEI U[ N/AE-4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE[] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y 0 N E UE] N/AE-: YZ NE U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 184 of 444 Equipment ID No. SQN-2-FAN-030-0462-B E Equip. ClasS3_ 9 -Fan Equipment Description DIESEL GEN 2B-B ELECT BD ROOM EXHAUST Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[ NE UF"E N/AD 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE[ N/AEI and masonry block walls not likely to collapse onto the equipment? Masonry block wall near equipment approved in calculation SCG-1-86.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y Z NE] U0 N/AEI YZ NO UE Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y N NEI U E[adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/24/12 7/24/12 Page 185 of 444 Y NON UE Seismic Walkdown Checklist (SWC)Equipment lID No. SQN-0-AHU-31 1-0023-B Equip. Class 3 10 -Air Handler Equipment Description MAIN CONTROL ROOM AHU B-B* Location: Bldg. Control Floor El. 732 Room, Area 12 -Control Mechanical Equipment Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YED NEI UE N/AE YCK NEI UE N/AE YN NEI UE[ N/AE YE NEI UE N/AX YN NEI U0 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 186 of 444 Equipment ID No. SQN-0-AHU-311-0023-B E Equip. ClasS3 10 -Air Handler Equipment Description MAIN CONTROL ROOM AHU B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NO UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NE7 U[E N/AE0 and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NE UE1 N/AE1 YM NEI UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YN NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/27/12 7/27/12 Page 187 of 444 S t atus: YNI NE UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-AHU-313-0488 Equip. Class 3 10 -Air Handler Equipment Description 480V BD RM 2A SUPPLY AHU 2A-A Location: Bldg. Aux Floor El. 749 Room, Area 24 -480V 2A Mechanical Equipment Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y El N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE1 N/AE1 YN NE U- N/AE]4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NO UE N/AZ YZ NEI UE[.Enter the equipment class name from Appendix B: Classes of Equipment Page 188 of 444 Equipment ID No. SQN-2-AHU-313-0488 EqUipACA Equip. ClasS3. 10 -Air Handler Equipment Description 480V BD RM 2A SUPPLY AHU 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NE UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YM NEI Ui N/Ar and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE Y[N NEI U Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could
  • Y Z NO U I adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/31/12 Phillio York 7/31/12 Page 189 of 444 St.atu: Y NEI U]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CLR-030-0 178 Equip. Class 3 10 -Cooler Equipment Description CS PUMP COOLER 28-B Location: Bldg. Aux Floor El. 653 Room, Area 44 -CS Pump Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[-] N[N of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware'?

Nuts are missing from rear center and rear corner anchor bolts. Upon further investigation, calculation DCG-4M-O01 73 shows that the equipment was seismically qualified for this arrangement.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NEI Ur N/AO Y[ NE Urn N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE Urn N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI U- N/AM Y[Z NE] U E 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 190 of 444 Equipment ID No. SQN-2-CLR-030-0S178 E l 1 e Equip. ClasS3 10 -Cooler Equipment Description CS PUMP COOLER 2B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[ NEI Ur N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE) N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE7 N/AEI YN NEI UE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U E]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Isaac Antanaitis Date: 8/22/12 Philipt York 8/22/12 Page 191 of 444 Status: YNNEIUE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CLR-030-180-A Equip. Class 3 10 -Air Handler Equipment Description SIS PUMP COOLER 2A-A Location: Bldg. Aux Floor El. 669 Room, Area 26 -S1 Pump Room 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE N/AE Y[ NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE UE N/AO 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AZ YN NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 192 of 444 Equipment ID No. SQN-2-CLR-030-180-A Equip. ClasS3 10 -Air Handler Equipment Description SIS PUMP COOLER 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE[ N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NO U] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NO UE N/AE YM NEI U-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YM NO UI-E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 8/1/12 8/1/12 Page 193 of 444 Statu. :YN NEIUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. O-CHR-311-0126 Equip. Class 3 11 -Chiller Equipment Description MAIN CONTROL ROOM CHILLER PKG A-A Location: Bldg. Control Floor El. 732 Room, Area 12 -Control Mechanical Equipment Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing CS-LIT(X585)- 1X585.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YX NE UE] N/AE Yl NO Uf N/AO 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NO UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE N/AE YZ NE UO 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 194 of 444 Equipment ID No. 0-CHR-311-0126 Equip. ClasS3 11 -Chiller Equipment Description MAIN CONTROL ROOM CHILLER PKG A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI U] N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NrD UrE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE7 N/AE YCK NEI UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/30/12 7/30/12 Page 195 of 444 St.t.t: YY NO UO Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-CHR-311-0171 Equip. Class 3 11 -Chiller Equipment Description ELEC. BD. ROOM CHILLER PKG. B-B Location: Bldg. control Floor El. 669 Room, Area 37 -669 Mech Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorame 1. Is the anchorage configuration verification required (i.e., is the item one NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 48N1288, Mk 4&5.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?There are cracks in the housekeeping pad. These cracks do not extend into the concrete slab.5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Grout was found to cover the bottom steel plate and the corresponding welds. All bolts were visible above the grout and are in good condition.

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NE U] N/AE YZ NEI U- N/A[E YZ NEI U- N/A-YCK NE UE N/AE YN NEI U[3 Enter the equipment class name from Appendix B: Classes of Equipment Page 196 of 444 Equipment ID No. SQN-0-CHR-311-0171 Equip. ClaSS3 11 -Chiller Equipment Description ELEC. BD. ROOM CHILLER PKG. B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UEr N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YCK NEI UE[ N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y I NE UE N/AE Y[Z NEI Ur Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U E[adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phi/lip York Date: 817/12 8/7/12 Page 197 of 444 St.ts: YZ NE U[Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-CHR-313-0338A Equip. Class 3 11 -Chiller Equipment Description SHUTDOWN BD RMS A & B WATER CHILLER PKG B-B Location: Bldg. Aux Floor El. 714 Room, Area 40 -Shutdown Board B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YO NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NO UE N/AE YN NE UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AM Y[ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 198 of 444 Equipment ID No. SQN-O-CHR-313-0338A Equip. ClasS3 11 -Chiller Equipment Description SHUTDOWN BD RMS A & B WATER CHILLER PKG B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Fire protection line is in contact with foam insulation on top of chiller piping. This is not a soft target and not considered seismically adverse.8. Are overhead equipment, distribution systems, ceilingtiles and lighting, and masonry block walls not likely to collapse onto the equipment? Overhead light wire restraint is no longer connected to the ceiling.This is not considered seismically adverse.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE-Y C N E U[1 N/AEINO UE N/AEI YZNNUE]Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

One position set screw for chiller motor is missing and another is not in contact with the motor. Per ex-SRO, contact is not required and set screws are used for installation purposes only.Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/8/12 Phillio York 8/8/12 Page 199 of 444 St.tus: YN NEI UE]Seismic Walkdown Checklist (SWC)Equipment lID No. SQN-2-CHR-313-0483 Equip. Class 3 11 -Chiller Equipment Description 480V ELECT BOARD RM 2A-A Location: Bldg. Aux Floor El. 749 Room, Area 24 -480V 2A Mechanical Equipment Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[E of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UEr N/AE YN NEI UE[ N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AO 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AN YN NE UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 200 of 444 Equipment ID No. SQN-2-CHR-3 13-0483 EupClasM1 Equip. ClaSS3 11 -Chiller Equipment Description 480V ELECT BOARD RM 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI U1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NO U1 N/AE and masonry block walls not likely to collapse onto the equipment? High distribution of hairline cracks in the block wall near equipment. Cracks are exaggerated due to suction through cracks. Plant has been advised to monitor. Not considered seismically adverse.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YEK NEI UE[ N/AE YM NEI UE[Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YX NEI UEZ adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/31/12 Phillip York 7/31/12 Page 201 of 444 Status: YN NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-CMP-032-0086-B Equip. Class 3 12 -Air Compressor Equipment Description AUX CONTROL AIR COMPRESSOR B-B Location: Bldg. Aux Floor El. 734 Room, Area 32 -Surge Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NER of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YCK NE UE- N/AE-YN NEI UE] N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y Z N E] U El N/A E]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AIK YN NE U0 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 202 of 444 Equipment ID No. SQN-A-CMP-032-0086-B OEquip C 2 m Equip. ClasS3 12 -Air Compressor Equipment Description AUX CONTROL AIR COMPRESSOR B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI UE] N/AEI 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE U- N/A-and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE- N/AE YN NO- U Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI Ur-E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 Phillio York 8/6/12 Page 203 of 444 St.a.t: YN NO U Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CMP-082-0240 Equip. Class 3 , 12 -Air Compressor Equipment Description DSL 2A 1 STARTING AIR COMPRESSER 25.5 CFM Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YrZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 10N320-2, Detail F2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YX NEI Ur N/AE YN NE U[E N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YX NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NE UE N/AE Y NOU-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 204 of 444 Equipment ID No. SQN-2-CMP-082-0240 Equip. ClasS3 12 -Air Compressor Equipment Description DSL 2A1 STARTING AIR COMPRESSER 25.5 CFM Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UO N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[ NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NE UE N/AE YON[UE]Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NE U E[adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/16/12 Phillip York 7/16/12 Page 205 of 444

YN NO UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CMP-082-0241 Equip. Class 3 12 -Air Compressor Equipment Description DSL 2A2 STARTING AIR COMPRESSOR 25.5 CFM Location:

Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 10N320-2, Detail F2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NO U- N/AEr YN NEI U- N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Yl NEI UE N/Ar 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YIC N E- UE7 N/AE YM1NEI-U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 206 of 444 Equipment ID No. SQN-2-CMP-082-0241 Equip. ClasS3 12 -Air Compressor Equipment Description DSL 2A2 STARTING AIR COMPRESSOR 25.5 CFM Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NE UE N/AO 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE U[] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE N/A Y NrUEI Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y I] NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages maybe added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/17/12 7/17/12 Page 207 of 444 Status: YN NEIUO Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CMP-082-0271 Equip. Class 3 12 -Air Compressor Equipment Description DSL 2B2 STARTING AIR COMPRESSER 25.5 CFM Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[Z NE0 of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 10N320-2, Detail F2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI U1 N/AD YN NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NO UE] N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE- N/AE YZ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 208 of 444 Equipment ID No. SQN-2-CMP-082-0271 Equip. ClasS3 12 -Air Compressor Equipment Description DSL 2B2 STARTING AIR COMPRESSER 25.5 CFM Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YCK NEI UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE N/AEI and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE7 N/AE1 YM NEI UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YM NE] U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/23/12 7/23/12 Page 209 of 444 S t a t us: :YNNEDUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-GEND-085-DG/4D Equip. Class 3 13 -Motor Generator Equipment Description 4Q. CONTROL ROD DRIVE GENERA TOR 2A Location: Bldg. Aux Floor El. 759 Room, Area 30 -CRDM Room Manufacturer, Model, Etc. (optional but recommended) E-M Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y Z NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 45N232 &48N1275.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI UE N/AE-YZ NEI UE N/A-4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YO NEI UE N/AE YM NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 210 of 444 Equipment ID No. SQN-2-GEND-085-DG/4DE Equip. ClaSS3 13 -Motor Generator Equipment Description 4D, CONTROL ROD DRIVE GENERA TOR 2A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Hoist is anchored to pipe support near equipment and can roll into equipment. There are no soft targets on the equipment, therefore this is considered insignificant. YM NEI UE] N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NEI U N/A E1 and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/A[]YN NE U-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI UrE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/3/12 Phillio York 8/3/12 Page 211 of 444 St.t..: YO NM UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-GEND-085-DH/3B Equip. Class 3 13 -Motor Generator Equipment Description 3B.CONTROL ROD DRIVE GENERATOR 2B Location: Bldg. Aux Floor El. 759 Room, Area 30 -CRDM Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 45N232 &48N12 75.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NEI U- N/AE Y[ NE UE] N/AEq 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE UE N/AE]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE YM NE U1 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 212 of 444 Equipment ID No. SQN-2-GEND-085-DH/3B Equip. ClasS3 13 -Motor Generator Equipment Description 3B. CONTROL ROD DRIVE GENERATOR 2B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YE NM UE N/AE and masonry block walls not likely to collapse onto the equipment? Duct support missing bolt from baseplate above equipment at size reduction.

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE YM NEI- U Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YZ NE UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Housing between motor and generator missing one bolt. Bolt can be seen under engine. Not considered significant. Evaluated by: Robert Malone Date: 8/3/12 Phillip York 8/3/12 Page 213 of 444 S.t.t: YN NEI UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-XSW-250-KL-S Equip. Class 3 14 -Transfer Switch Equipment Description SPARE 480 V AC VITAL TRANSFER SW 2-S Location: Bldg. Aux Floor El. 749 Room, Area 22 -480V Board Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y Z N E]of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 48N12 72, Detail Mks 36, 37, 38, & 39.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Only 4 bolt locations between the panel and the angle fiame were noted in the walkdown. The corresponding drawing shows multiple possible locations for bolts, but it appears that every location is not required for installation. 4 bolts is sufficient attachment for the panel.6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? YN NE UE N/AE]YN NE UE- N/AE YZ NO UE] N/AE]YN NEl UE N/AE YZ NEIUE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 214 of 444 Equipment ID No. SQN-O-XSW-250-KL-S Eq 14 -T Equip. ClasS3 14 -Transfer Switch Equipment Description SPARE 480 V AC VITAL TRANSFER SW 2-S Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures?

8. Are overhead equipment, distribution systems, ceiling tiles and lighting, and masonry block walls not likely to collapse onto the equipment?

Masonry block wall behind equipment approved in calculation46W405-8 & -9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YER NEI UE N/AE Y 0 NE: U E- N/A E]Y E NE] U E N/AE YZ NEI UE-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y f] NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/20/12 Phillip York 7/20/12 Page 215 of 444 S tat.. :YN NEIUE--Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-XSW-250-KX-S Equip. Class 3.14 -Transfer Switch Equipment Description 125 VDC CHGR 2-S DC XFER SW TO VBB I//Location: Bldg. Aux Floor El. 749 Room, Area 22 -480V Board Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoralze

1. Is the anchorage configuration verification required (i.e., is the item one Yi] NE of the 50% of SWEL items requiring such verification)?

For anchorage configuration verification see drawings 48N12 72, Detail Mks 36, 37, 38, & 39.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Only 4 bolt locations between the panel and the angle frame were noted in the walkdown. The corresponding drawing shows multiple possible locations for bolts, but it appears that every location is not required for installation. 4 bolts is sufficient attachment for the panel.6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? YM NE UE N/AE YZ NE UE N/AE YZ NE UE] N/AE YE NEI UE N/AE YN NEIUE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 216 of 444 Equipment ID No. SQN-O-XSW-250-KX-S Equip. ClasS3 14 -Transfer Switch Equipment Description 125 VDC CHGR 2-S DC XFER SW TO VBB /l/Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI U'I N/AEI 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y M N E- UrE- N/A E and masonry block walls not likely to collapse onto the equipment? Masonrv block wall behind equipment approved in calculation46W405-8 & -9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE1 N/AE Y[ NEI UE-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YER NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/20/12 PhiiD York 7/20/12 Page 217 of 444 Status: YY NO UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDE-250-NF-E Equip. Class 3 14 -Distribution Panel Equipment Description 120VAC VITAL INSTR POWER BD 2-11 Location: Bldg. Aux Floor El. 734 Room, Area 14 -125V Vital Board Room II Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NX of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified The power boards exist in one continuous cabinet and no panel-to-panel anchorage was observed Front panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corr~sion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE-]YER NE UE N/AE YN NEI UE N/AE YO NE UE N/AS YN NEI UE-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 218 of 444 Equipment ID No. SQN-2-BDE-250-NF-E Equip. (Equipment Description 120VAC VITAL INSTR POWER BD 2-11'lass 3 14 -Distribution Panel Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YCK NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YN NEI UE N/AE and masonry block walls not likely to collapse onto the equipment? Masonry block wall behind equipment approved in calculation SCGIS30X 1I and drawing 46W405-9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NE UEI N/AE]Y[ N[ UE Other Adverse Conditions L1. Have you looked for and found no other seismic conditions that could Y M NE UE [adversely affect the safety functions of the equipment? Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/26/12 James Edaar 7/26/12 Page 219 of 444 St.a.u: YZ NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-BDE-250-NK-G Equip. Class 3 14 -Distribution Panel Equipment Description 120VAC VITAL INSTR POWER BD 2-1V Location: Bldg. Aux Floor El. 734 Room, Area 14 -125V Vital Board Room II Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraie 1. Is the anchorage configuration verification required (i.e., is the item one YEI NIC of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified The power boards exist in one continuous cabinet and no panel-to-panel anchorage was observed Front panels required extensive disassembly to open. Weld between channel and cabinet was checked for condition only.3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NEI UE N/AE YN NEI UE[ YN NEI UEr N/AD-Y E N[E- UE N/A[E YN NEI-UE-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 220 of 444 Equipment ID No. SQN4.BDE25ONKG Equip. C Equipment Description 120VAC VITAL INSTR POWER BD 24IV lass 3 14 -Distribution Panel Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI UE N/AE]8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y NEI UE N/AE and masonry block walls not likely to collapse onto the equipment? Overhead fluorescent bulbs have spring lock attachment. Follow-up to review calc for block walls.Masonry block wall behind equipment approved in calculation 46W405-9.9. Do attached lines have adequate flexibility to avoid damage?Flex hose used 10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE1 N/AE YCK NEI UE]Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y[3 NEI U7 adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Lance Summers Date: 7/26/12 Isaac Antanaitis 7126/12 Page 221 of 444 S t.at: YI NEI U-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PNLA-082-TV-A Equip. Class 3 14 -Distribution Panel Equipment Description DG 2A-A 125 VOLT DC DISTRIBUTION PNL Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NN of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Front panel was opened and anchorage to structure was verified 3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YX NEI UE[ N/AE YER NE UE--1 N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YCK NE UE N/AE[]Visible concrete around cabinet shows no cracking.5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE[ NEI UE N/AIK YE NEI UER 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 222 of 444 Equipment ID No. SQN-2-PNLA-082-TV-A Equip. ClasS3 14 -Distribution Panel Equipment Description DG 2A-A 125 VOLT DC DISTRIBUTION PNL Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI Ur N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NO UE- N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE)YZ NEI U-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y [J NE U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/17/12 Phillin York 7/17/12 Page 223 of 444 S t.a.: Y[] NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-XSW-082-UH-A Equip. Class 3 18 -Transfer Switch Equipment Description DG 2A-A 480V TRANSFER SWITCH Location: Bldg. DG Floor El. 722 Room, Area 1 -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YEr NCK of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y" NE: UE: N/AE]Y"C NE0 UrE N/AE-1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YIZ NE UE N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YEI NE UE] N/AM YN NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 224 of 444 Equipment ID No. SQN-2-XSW-082-UH-ANEquIpCl Equip. ClasS3 18 -Transfer Switch Equipment Description DG 2A-A 480V TRANSFER SWITCH Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ ND UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y M NE U Er N/A E and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AE YN NEI U-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NO U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/18/12 7/18/12 Page 225 of 444 Status: YN NEI UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-BATB-250-QX-F Equip. Class 3.15 -Battery Rack Equipment Description 125V Vital Battery Room Hll Batteries 1-20 Rack Location: Bldg. Aux Floor El. 749 Room, Area 20 -125V Battery Room Ill Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NE]of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 1,2-45N230, Section B-B.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI UE] N/AE YN NE UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE-[ UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YX NE UE N/AE YNNEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 226 of 444 Equipment ID No. SQN-O-BA TB-250-QX-F Equip. ClasS3 15 -BatterV Rack Equipment Description 125V Vital Battery Room /ll Batteries 1-20 Rack interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ Nr Ur N/AE and masonry block walls not likely to collapse onto the equipment? Masonrv block wall behind equipment approved in calculation46W405-8 & -9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO U[ N/AE YIR NEI U0 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/20/12 Phillip York 7/20/12 Page 227 of 444 S t a t u: :YNNO UO Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-BA TB-250-QX-F Equip. Class 3 15 -Battery Rack Equipment Description 125V Vital Battery Room /it Batteries 21-40 Rack Location: Bldg. Aux Floor El. 749 Room, Area 20 -- 125V Battery Room III Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YZ Nr of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 1,2-45N230, Section B-B.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? Y[K NEI UE N/AEq Y 0 NrE U E] N/A1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE] N/AE[5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Yr NEI UE N/AE]YN NEI UO 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 228 of 444 EquipmentIDNo. SQN--BAtTB-250-QX-F Equip. ClasS3 15 -Battery Rack Equipment Description 125V Vital Battery Room Ill Batteries 21-40 Rack Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NE UE1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NO UE N/A[]and masonry block walls not likely to collapse onto the equipment? Masonry block wall behind equipment approved in calculation46W405-8 & -9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE- N/AE YCK NEI UE Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YEK NE U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/30/12 7/30/12 Page 229 of 444 St.,t.: YN NO UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-BA TB-250-QX-F Equip. Class 3 15 -Battery Rack Equipment Description 125V Vital Battery Room /Il Batteries 4 1-60 Rack Location: Bldg. Aux Floor El. 749 Room, Area 20 -. 125V Battery Room Ill Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 1,2-45N230, Section B-B.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YZ NEI UE[ N/AE Y 0 N[E UE] N/A1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YM NEI UE N/AE YZ NEI UEI 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 230 of 444 Equipment ID No. SQN-0-BATB-250-QX-F Equip. Class 3 1I Equipment Description 125V Vital Battery Room Ill Batteries 41-60 Rack 5 -Battery Rack Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NO U0 N/AE1 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YN NEI Ur N/AE and masonry block walls not likely to collapse onto the equipment? Masonry block wall behind equipment approved in calculation46 W405-8 & -9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NE UE N/A-Y[]NEUE Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NEI UE[]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/20/12 PhiiD York 7/20/12 Page 231 of 444 S t a t u: :YEINZ iU1: Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-BATB-250-QY-G Equip. Class 3 15 -Battery Rack Equipment Description 125V Vital Battery Room IV Batteries 1-20 Rack Location: Bldg. Aux Floor El. 749 Room, Area 21 -- 125V Battery Room IV Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y Z ND of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 1,2-45N230, Section B-B.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NE UE N/AE[YO NEI UE3 N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YER NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NE UE[ N/A[]YM NEI U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 232 of 444 Equipment ID No. SQN-0-BA TB-250-QY-G Equip. ClaSS3 15 -Battery Rack Equipment Description 125V Vital Battery Room IV Batteries 1-20 Rack Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YC NEI UE] N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y NZ UE- N/AE and masonry block walls not likely to collapse onto the equipment? Masonry block wall above and to the right of sink has a horizontal crack at the top of the wall near the supporting angle. This crack is approximately 6' long and can be seen on both sides of the masonry block wall.Masonry block wall behind equipment approved in drawing 46W405-8&-9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NE UE- N/AE YE7 NCK U-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y N NEI U[adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/25/12 7/25/12 Page 233 of 444 St.t.t: YE NM UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-BATB-250-QY-G Equip. Class 3 15 -Battery Rack Equipment Description 125V Vital Batter' Room IV Batteries 2 1-40 Rack Location: Bldg. Aux Floor El. 749 Room, Area 21 -125V Battery Room IV Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NE]of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 1, 2-45N230, Section B-B.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NO UO N/AE1 YZ NEI UE] N/AE]YCK NE UE] N/AE-Y C N E- U El N/AE YZ NEI-UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 234 of 444 Equipment ID No. SQN-0-BATB-250-QY-G Equip. ClasS3 15 -Battery Rack Equipment Description 125V Vital Battery Room IV Batteries 21-40 Rack Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[ NEI UEJ N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YE NZ UE N/AET and masonry block walls not likely to collapse onto the equipment? Masonry block wall above and to the right of sink has a horizontal crack at the top of the wall near the supporting angle. This crack is approximately 6' long and can be seen on both sides of the masonry block wall.Masonry block wall behind equipment approved in drawing 46W405-8&-9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NEI UE- N/AE YO NED U-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/25/12 Phillip York 7/25/12 Page 235 of 444 S Yr NE UEI Seismic Walkdown Checklist (SWC)Equipment lD No. SQN-0-BATB-250-QY-G Equip. Class 3 15 -Battery Rack Equipment Description 125V Vital Battery Room IV Batteries 41-60 Rack Location: Bldg. Aux Floor El. 749 Room, Area 21 -- 125V Battery Room IV Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 1,2-45N230, Section B-B.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? Y* NE UE N/AE Y*N NEr UE] N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y Z N E UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NE UE N/AE1 YX NEI UE[3 Enter the equipment class name from Appendix B: Classes of Equipment Page 236 of 444 Equipment ID No. SQN-O-BATB-250-QY-G Equip. ClaSS3 15 -Battery Rack Equipment Description 125V Vital Batter, Room IV Batteries 4 1-60 Rack Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YERNEIUO N/AEl 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE] U[j N/Ar and masonry block walls not likely to collapse onto the equipment? Masonry block wall behind equipment approved in drawing 461W405-8&-9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE N/AE[YM NEI UE7 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NEI U -adversely affect the safety functions of the equipment?

Comments(Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/24/12 Phillip York 7/24/12 Page 237 of 444 Status: yN NEI UU Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2 -BA TB-082-UD-A Equip. Class 3 15 -Battery Rack Equipment Description Diesel Gen. 2A-A Batten' Rack Location: Bldg. DG Floor El. 722 Room, Area 1 -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorale 1. Is the anchorage configuration verification required (i.e., is the item one YrZ NDI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1 0N320-2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

  • YN NDI UD N/AD-Y[1 NDI UD1 N/AD 4. Is the anchorage free of visible cracks in the concrete near the anchors? YCR NDI UD1 N/AD[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YM ND UD] N/AD3 Enter the equipment class name from Appendix B: Classes of Equipment Page 238 of 444 Equipment ID No. SQN-2-BATB-082-UD-A Eu.Csr5Btrca Equip. ClasS3 15 -Battery Rack Equipment Description Diesel Gen. 2A-A Battery Rack Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YER NED UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Yr NE UE N/AEl and masonry block walls not likely to collapse onto the equipment? Emergency eyewash station near equipment was not anchored properly and could cause a hazard during a seismic event. On a later visit, the eyewash station was anchored to a nearby sink. Barrier posts near equipment were not anchored This is not considered seismically significant.

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UEr N/AE YZ NEI UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YN NEI UE--adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/16/12 Phiio York 7/16/12 Page 239 of 444 Sr.t 8.. :YOENMUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-CHGB-250-QJ-G Equip. Class 3 16 -Charger Equipment Description DIG 2B-B BATTERY CHGR Location: Bldg. Aux Floor El. 749 Room, Area 22 -480V Board Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YEI NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YCK NE UE3 N/AENEI UE[ N/AE1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UO N/AN YN NEI UE1 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 240 of 444 Equipment ID No. SQN-O-CHGB-250-QJ-G E Equip. ClaSS3 16 -Charger Equipment Description DIG 2B-B BATTERY CHGR Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y 0 N E UF] N/AD 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YO UD N/AD and masonry block walls not likely to collapse onto the equipment? Masonry block wall above equipment has a horizontal crack at the top of the wall near- the supporting angle. This crack is approximately 6'long and can be seen on both sides of the masonry block wall.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UD- N/AD7 YNN U-Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y N NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/25/12 7/25/12 Page 241 of 444 St.a.t: Y[ NO UO Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-CHGB-250-QK-S Equip. Class 3 16 -CharQer Equipment Description 125V DC VITAL BATTERY CHARGER 2-SPARE Location: Bldg. Aux Floor El. 749 Room, Area 22.. 480V Board Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 48N1 274.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? Y[] NEI UE1 N/AE Y[ NEI UE] N/AE1 4. Is the anchorage free of visible cracks in the concrete near the anchors? YX NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NE UE N/AE Y N-UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 242 of 444 Equipment ID No. SQN-0-CHGB-250-QK-S Equip. ClaSS3 16 -Charger Equipment Description 125V DC VITAL BATTERY CHARGER 2-SPARE Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[R NE UE] N/AE[8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YO No UE N/AE and masonry block walls not likely to collapse onto the equipment? Masonry block wall behind equipment approved in calculation46W405-8 & -9.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NR N I]UrE N/A El YN NEI UEA Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/20/12 PhilliD York 7/20/12 Page 243 of 444 S t a t u. YM Y!NEIUE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CHGB-082-TZ-A Equip. Class 3 16 -Charger Equipment Description DG 2A-A BATTERY CHARGER Location: Bldg. DG .Floor El. 722 Room, Area 1 -Bay 2A Manufacturer, Model, Etc. (optional but recommended) LaMarche Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE0 NIZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y[] NE UE1 N/AE]YN NEI UE N/AEl 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y I] NEI U N/A E 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AN Y[NNUE1 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 244 of 444 Equipment ID No. SQN-2-CHGB-082-TZ-A Eq Equip. ClasS3 16 -Charger Equipment Description DG 2A-A BATTERY CHARGER Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[ NE UE7 N/AO 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE[ N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y 1 NrE U I] N/ArEl YM NEI UE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/16/12 7/16/12 Page 245 of 444 St.t.s: YN NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CHGB-082-UA-B Equip. Class 3 16 -Charger Equipment Description DIG 2B-B BATTERY CHGR Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Yr-- NIZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE- N/AE1 YN NEI UE N/A[E YZ1 NEI UE] N/AE1 YE NEI UE N/AN YN NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 246 of 444 Equipment ID No. SQN-2-CHGB-082-UA-B E l 1C Equip. ClaSS3 16 -Charger Equipment Description DIG 2B-B BATTERY CHGR Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NO UEI N/A-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YN NE UE:[ N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI U- N/Al YM NEI U1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y X NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/23/12 7/23/12 Page 247 of 444 Stat.s: YO NO U0 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-INVB-250-QU-G Equip. Class 3 16 -Inverter Equipment Description 120VAC VITAL INVERTER 2-1V Location: Bldg. Aux Floor El. 749 Room, Area 22 -480V Board Room 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results.of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorase 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see DCA D20071-392 and 382.2. Is the anchorage free of bent, broken, missing or loose hardware?Front nut was loose on second set of anchorage. A4 1/8" gap was noted between the washer and nut. This is not considered seismically significant.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

YO NO YZ N UE3 N/AE YO NE UE1 N/AE YN NE U- N/AE Y[ NEI UO N/AE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 248 of 444 Equipment ID No. SQN-2-INVB-250-QU-G EquIp Equip. ClasS3 16 -Inverter Equipment Description 120VAC VITAL INVERTER 2-1V 6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? YM NEI UE7 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YCK NEI UE- N/A-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YE7 N Z U E N/AE and masonry block walls not likely to collapse onto the equipment? Masonry block wall above equipment has a horizontal crack at the top of the wall near the supporting angle. This crack is approximately 6'long and can be seen on both sides of the masonry block wall.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y Z N E- UE1 N/AE YEI NZ UE7 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could Y M NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/25/12 7/25/12 Page 249 of 444 S tatu. 5 Y19NDEU Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-ENG-082-0002A I Equip. Class 3 17 -Enqine Generators Equipment Description ENG 2A 1 Location: Bldg. DG Floor El. 722 Room, Area 1 -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraie 1. Is the anchorage configuration verification required (i.e., is the item one y NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1, 2-A950F12002.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y[ NEI U- N/AE-YZ NE UEJ N/AE1 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y[] NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NE UE N/AE-YN NEI UE[3 Enter the equipment class name from Appendix B: Classes of Equipment Page 250 of 444 Equipment ID No. SQN-2-ENG-082-0002A 1 E Equip. Class-' 17 -Engine Generators Equipment Description ENG 2A I Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE[ N/A-" 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[] NE U- N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE- N/AE YM NEI UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U E]adversely affect the safety functions of the equipment?

The connection between the generator skid and the engine skid was field modified by removing the shear tab and flange plate bolts.Misalignment was noted in the bolt holes. Not considered seismically significant. Comments (Additional pages may be added as necessary) Many locations show oil leakage.Evaluated by: Robert Malone Date: 7/17/12 Phillip York 7/17/12 Page 251 of 444 Sta t us: :YZ NOUE3 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-ENG-082-0002A2 Equip. Class 3 17 -Engine Generators Equipment Description ENG 2A2 Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoralze

1. Is the anchorage configuration verification required (i.e., is the item one YtZ NE of the 50% of SWEL items requiring such verification)?

For anchorage configuration verification see drawing 1, 2-A950F12002.

2. Is the anchorage free of bent, broken, missing or loose hardware?Washer was missing on one offourteen anchor bolts. Not considered seismically significant.
3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y I N E U E] N/AE YO NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NE UE] N/A[E YN NEI UE1 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 252 of 444 Equipment ID No. SQN-2-ENG-082-0002A2 3 Equip. Class' 17 -Engine Generators Equipment Description ENG 2A2 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE] N/AEr 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y M N [] U [] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE-YN NEI UE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y I N E U [adversely affect the safety functions of the equipment?

The connection between the generator skid and the engine skid was field modified by removing the shear tab and flange plate bolts.Misalignment was noted in the bolt holes. Not considered seismically significant. Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/17/12 Philli York 7/17/12 Page 253 of 444 Sta.ts: YM NEI U-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-ENG-082-0002Bl Equip. Class 3 17 -Enqine Generators Equipment Description DIESEL ENGINE 2B1 Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1, 2-A950F12002.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?Cracks observed in grout pad at corners of concrete pad These cracks are not near anchorage.

Not considered seismically significant.

5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YER NO UE N/AE YN NEI UE1 N/AE YN NEI UE[ N/AO YEK NEI UE N/A-Y[ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 254 of 444 Equipment ID No. SQN-2-ENG-082-0002B1 E Equip. ClaSS3 17 -Engine Generators Equipment Description DIESEL ENGINE 2B1 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NE U E N/A[E and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UE N/AEI YON-UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U-adversely affect the safety functions of the equipment?

The connection between the generator skid and the engine skid was field modified by removing the shear tab and flange plate bolts.Misalignment was noted in the bolt holes. Not considered seismically significant. Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/23/12 Phillip York 7/23V12 Page 255 of 444 S.r.au: YN NEI UEU Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-ENG-082-0002B2 Equip. Class 3 17 -Engine Generators Equipment Description DIESEL ENGINE 2B2 Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NF]of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1,2-A950F12002.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UE N/AE-NEI U[ N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UD N/AE[YM NEI UE7 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 256 of 444 Equipment ID No. SQN-2-ENG-082-0002B2 E Equip. ClaSS3 17 -Engine Generators Equipment Description DIESEL ENGINE 2B2 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YC NEI UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NE U E N/A E and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE1 N/AE YZ NEI UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YN NE UE adversely affect the safety functions of the equipment?

The connection between the generator skid and the engine skid was field modified by removing the shear tab and flange plate bolts.Misalignment was noted in the bolt holes. Not considered seismically significant. Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/23/12 Phillib York 7/23/12 Page 257 of 444 S tatus: Y] N- UF Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-GENB-082-0002A Equip. Class 3 17 -Engine Generators Equipment Description DIESEL GEN. 2A-A Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y Z NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1,2-A950F12002.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE N/AE YNl NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YfZ NE U- N/AE YN NEI U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 258 of 444 Equipment ID No. SQN-2-GENB-082-0002A E Equip. Class'-' 17 -Engine Generators Equipment Description DIESEL GEN. 2A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NO UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Yl NE] UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NO UE N/AE Y[R NEI UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y !] NEI U []adversely affect the safety functions of the equipment?

The connection between the generator skid and the engine skid was field modified by removing the shear tab and flange plate bolts.Misalignment was noted in the bolt holes. Not considered seismically significant. Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/17/12 Phillib York 7/17/12 Page 259 of 444 Status: :YENEIUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-GENB-082-0002B Equip. Class 3 17- Engine Generators Equipment Description DIESEL GEN. 2B-B Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walldown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YZ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1,2-A950F12002.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NE U- N/AE Y[] NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y!N NE UE N/A []5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE N/AE: YNNEI UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 260 of 444 Equipment ID No. SQN-2-GENB-082-0002B E Equip. ClaSS3 17 -Engine Generators Equipment Description DIESEL GEN. 2B-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE N/AE1 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y M NE: UE1 N/AE1 and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI U- N/ANE-UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U-adversely affect the safety functions of the equipment?

The connection between the generator skid and the engine skid was field modified by removing the shear tab and flange plate bolts.Misalignment was noted in the bolt holes. Not considered seismically significant. Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/23/12 Phillip York 7/23/12 Page 261 of 444 Status: YN NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-LOCL-500-0428 Equip. Class 3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Location: Bldg. Aux Floor El. 734 Room, Area 32 -Surge Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorane 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE N/AE1 YM NE UE1 N/AE[4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE1 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE] NE: UE N/AN YNNEIUE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 262 of 444 Equipment ID No. SQN-O-LOCL-500-0428 EqUIp sINR Equip. ClasS3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Nearby cabinet is anchored properly. Table with frisker is not anchored Not considered seismically adverse.YCK NEI UE- N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y 0 NE: UE- N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UE1 N/AE'N YMNOUO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YfN NE UE-adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/3/12 Phillip York 8/3/12 Page 263 of 444 S-ta.t: Y NEI UEN Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-0005 Equip. Class 3-18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Location: Bldg. Aux Floor El. 653 Room, Area 25 -RHR Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YEI NZ[of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NEI UE N/AE-YZ NE UE N/AE[4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE UE N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE- N/AZ YNEN1UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 264 of 444 Equipment ID No. SQN-2-LOCL-500-0005 Equip. ClaSS3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NE U- N/AE1 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y [Z N E U 0 N/A E and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y M NEI U E N/AE Y[NOU-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 8/1/12 8/1/12 Page 265 of 444 Sta.t.: YM NEI UE-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-0019 Equip. Class 3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Location: Bldg. Aux Floor El. 734 Room, Area 32 -Surge Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraaze

1. Is the anchorage configuration verification required (i.e., is the item one Y E N Z of the 50% of SWEL items requiring such verification)?
2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UE N/AE1 Y1 NEI UEr N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y NEI U E N/A E 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE[ NEI UE N/AN Y[N NE UE[3 Enter the equipment class name from Appendix B: Classes of Equipment Page 266 of 444 Equipment ID No. SQN-2-LOCL-500-0019 EqUIp s It t Equip. ClaSS3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NE UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UE1 N/AE YZ NEI UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 Phillib York 8/6/12 Page 267 of 444 S atus: YIN1NEIUE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-0048 Equip. Class 3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Location: Bldg. Aux Floor El. 690 Room, Area 27 -CCS Pump Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y E- N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE N/AE YM NE UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NE UE N/AE]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y E NE UE N/A 0 YX NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 268 of 444 Equipment ID No. SQN-2-LOCL-500-0048 EqUIp s Ir R Equip. Class-' 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures?"Special Fire Barrier" wall is cantilevered to the floor and is seismically qualified by TVA calculation SCG-1-48.YN NE UE[ N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NEl U[E N/AE and masonry block walls not likely to collapse onto the equipment? See note #7.9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE1 N/AE1 YM NEI UE1 Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YN NO UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/2/12 Phillip York 8/2/12 Page 269 of 444 S,,,..,: Ya NNE UE Seismic Walkdown Checklisi (SWC)Equipment ID No. SQN-2-LOCL-500-0163 Equip. Class 3 18 -Instrument Rack Equipment Description FLOOR PANEL DGB Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y E N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NE UE N/AE Y Z NE] UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AZ YZ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 270 of 444 Equipment ID No. SQN-2-LOCL-500-0163 Equip. ClasS3 18 -Instrument Rack Equipment Description FLOOR PANEL DGB Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE[ N/AE]8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YCR NE] Uc EN/AE]and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YR NEI UE1 N/AEl YNNE]UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/23/12 7123112 Page 271 of 444 Sta,..: YOu NCR UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-0222B Equip. Class 3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILIARY BUILDING Location: Bldg. Aux Floor El. 690 Room, Area 38 -Aux Feedwater Pump B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorap-e

1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?
2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE N/AE YN] NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NO UE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AM YN NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 272 of 444 Equipment ID No. SQN-2-LOCL-500-0222B EqUIp s Ir R Equip. ClasS3 18 -Instrument Rack Equipment Description FLOOR PANEL AUXILARY BUILDING Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? 50 gallon barrels in the area are not properly restrained YEO NZ UL-I N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YIZ N[:] UE N/Ar-and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE: N/AEl YE- NZ UE]Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y[ NEI U[E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 8/7/12 8/7/12 Page 273 of 444 Sta,.u: Ys NE U Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TE-300-0450A-B Equip. Class 3 19 -Temperature Sensor Equipment Description DIESEL GEN 2B-B EXHAUST HIGH TEMP Location: Bldg. DG Floor El. 740 Room, Area 6 -2B Fan Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE0 N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NO UE N/AEJ YER NE UE- N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y EJ NEI U N/A E[5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE N/AN YN NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 274 of 444 Equipment ID No. SQN-2-TE-300-045A-B EquIp. a1 e n 3 Equip. Classý 19 -Temperature Sensor Equipment Description DIESEL GEN 2B-B EXHA US THIGH TEMP Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE[ N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YCK NE UE] N/AE[and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UO N/AE YZ NEI UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/24/12 Phillio York 7/24/12 Page 275 of 444 Status: YN NO UE Seismic Walkdown Checklist (SWC)Equipment 1D No. SQN-2-TE-300-0450B-B Equip. Class 3 19 -Temperature Sensor Equipment Description DIESEL GEN 2B-B EXHAUST LOW TEMP Location: Bldg. DG Floor El. 740 Room, Area 6 -2B Fan Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YE N Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UE N/AE YN NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE1 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE] NE UE N/AN Y[K NE U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 276 of 444 Equipment ID No. SQN-2-TE-300-045GB-B Equip. Class-" 19 -Temperature Sensor Equipment Description DIESEL GEN 2B-B EXHAUST LOW TEMP Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE1 N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YN NEI UE N/AEI and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NO UE7 N/A[YM NEI UEr.Other Adverse Conditions
11. Have. you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/24/12 7/24/12 Page 277 of 444 St.ta.: YN NO U[Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TE-300-0452A-A Equip. Class 3 19 -Temperature Sensor Equipment Description DIESEL GEN 2A-A EXHAUST-HIGH TEMP Location: Bldg. DG Floor El. 740 Room, Area 2A Fan Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YO NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Lower nut not fully engaged to plate. Given the small size of the equipment, this is not considered seismically adverse.3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE YM NEI UE N/AE YM NE UE N/AE YE NE UE N/AZ YN NO UE: 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 278 of 444 Equipment ID No. SQN TE-300-0452A-A Equp-. l 1ue Equip. Class,", 19 -Temperature Sensor Equipment Description DIESEL GEN 2A-A EXHAUST-HIGH TEMP Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NO UO N/AFE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE: N/AE and masonry block walls not likely to collapse onto the equipment? The masonty block wall on which the sensor is attached is verified per Calculation

  1. SCG-1-86.
9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NE UE N/AE[YM N[ U]Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YM NEI UE--adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/18/12 Phillio York 7/18/12 Page 279 of 444 YM NEI UE-Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TE-300-0452B-A Equip. Class 3 19 -Temperature Sensor Equipment Description DIESEL GEN 2A-A EXHAUST-LOW TEMP Location: Bldg. DG Floor El. 740 Room, Area 2A Fan Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoralze

1. Is the anchorage configuration verification required (i.e., is the item one YE] NZ of the 50% of SWEL items requiring such verification)?
2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NE UE N/AE YN NEI UE- N/AE YN NEI UE] N/AE YE NE UE1 N/AN YN NO UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 280 of 444 Equipment ID No. SQN-2-TE-300-0452B-A 3 Equip. Class' 19 -Temperature Sensor Equipment Description DIESEL GEN 2A-A EXHAUST-LOW TEMP Interaction Effects 7. Are soft targets free from impact by nearby equipment. or structures? YM NO UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y 0 N E] UE0 N/A0 and masonry block walls not likely to collapse onto the equipment? The masonry block wall on which the sensor is attached is verified per Calculation

  1. SCG-1-86.
9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NE U- N/AE YN NO U7 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/18/12 7/18/12 Page 281 of 444 St.tau: YY NEI U[1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TS-OO1-0018A-B Equip. Class 3 19 -Temperature Sensor Equipment Description STM FLOW TO AFPT ISOL -HIGH TEMP Location: Bldg. Aux Floor El. 669 Room, Area 34 -Aux Feedwater Pump Room 2A-S Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y 0 NCR of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YM NEI UE1 N/AEl YM ND UE] N/AEl 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y Z N El U E] N/A El 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y[l NEl Ul N/AM YNNEUEl 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 282 of 444 Equipment ID No. SQN-2-TS-MO1-0018A-B EIp. C 1ae 3 Equip. Class' 19 -Temperature Sensor Equipment Description STM FLOW TO AFPT ISOL -HIGH TEMP Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE N/A-and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NE UE1 N/AE YM NEI UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YER NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 PhilliD York 8/6/12 Page 283 of 444 S t a t us: YN NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TS-0O 1-001 8B-B Equip. Class 3 19 -Temperature Sensor Equipment Description STM FLOW TO AFPT ISOL -HIGH TEMP Location: Bldg. Aux Floor El. 669 Room, Area 34_- Aux Feedwater Pump Room 2A-S Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y.= Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE7 NZ]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NEI UE N/AE YZ NE UE] N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y Z N U E] N/A E]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE- N/AM YZ NEI UEr 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 284 of 444 Equipment ID No. SQN-2-TS-OO1-0018B-B Equip. l 1 e n Equip. Class3 19 -Temperature Sensor Equipment Description STM FLOW TO AFPT ISOL -HIGH TEMP Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI UE-"1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NE3 U E- N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AE-YM NEI UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YN NEI UE[]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 Philip~ York 8/6/12 Page 285 of 444 St.aus: YO NEI- UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-0-LOCL-500-M026D Equip. Class 3 20 Control Panel Equipment Description DIESEL GEN CONT Location: Bldg. Control Floor El. 732 Room, Area 13 -Control Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1,2-47W605-3, Detail B3.2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified Each control room panel consists of one continuous cabinet with multiple Risers. No Riser-to-Riser connections were observed It was noted that adjacent panels were bolted together on the front side of each cabinet-to-cabinet interface.

3. Is the anchorage free of corrosion that is more thanmild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NEI YZ NEI UE] N/AEI YN NEI UE N/AE YN NEI UE N/AE1 YZ NEI UE7 N/AEV YON.N] UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 286 of 444 Equipment ID No. SQN-0-LOCL-500-MO26D Equip. Class' 20 -Control Panel Equipment Description DIESEL GEN CONT Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YM NE UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE[ N/AE YE N[ UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YER NEI U[E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/27/12 Phil~lip York 7/27/12 Page 287 of 444 St.tus: YZ NEI UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-MO02 Equip. Class 3 20 -Control Panel Equipment Description TURB CONTROL Location: Bldg. Control Floor El. 732 Room, Area 13 -Control Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1,2-47W605-3, Detail A 3.2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified Each control room panel consists of one continuous cabinet with multiple Risers. No Riser-to-Riser connections were observed It was noted that adjacent panels were bolted together on the front side of each cabinet-to-cabinet interface.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YENEI YED NEI UE N/AEl YN NEI UEN N/AE YN NEI UE N/AE YZ NEI UE N/AE YN NEI UO 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 288 of 444 Equipment ID No. SQN-2-LOCL-500-MO02 E 3 Equip. Class' 20 -Control Panel Equipment Description TURB CONTROL Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI U[ N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UF N/AE]and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN1 NO UE N/AO YM NEI Ur7 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/31/12 7/31/12 Page 289 of 444 Status: YN NEIUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-M004 Equip. Class 3 20 -Control Panel Equipment Description Reactor Control Panel 2-M-4 Location: Bldg. Control Floor El. 732 Room, Area 13 -Control Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1, 2-47 W605-3, Detail A3.2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified Each control room panel consists of one continuous cabinet with multiple Risers. No Riser-to-Riser connections were observed It was noted that adjacent panels were bolted together on the front side of each cabinet-to-cabinet interface.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NO Y[ NEI UE] N/AE YER NE UE] N/AE Y[ NO UEr N/AE Y[ NEI UE] N/AE YZ NEI UE1 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 290 of 444 Equipment ID No. SQN-2-LOCL-500-Moo4 Equip.2-l 2 r Equip. Class' 20 -Control Panel Equipment Description Reactor Control Panel 2-M-4 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UEI N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NO UE N/AO and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YCK NE U- N/AE YN NEI UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NE U O adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/31/12 Phiihg. York 7/31/12 Page 291 of 444 S.t.au: Y NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LQCL-500-M008 Equip. Class 3 20 -Control Panel Equipment Description TURB SUP CONT Location: Bldg. Control Floor El. 732 Room, Area 13 -Control Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y El N X of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified Each control room panel consists of one continuous cabinet with multiple Risers. No Riser-to-Riser connections were observed It was noted that adjacent panels were bolted together on the front side of each cabinet-to-cabinet interface.
3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE N/AE YN NE UE N/AE[Y Z N E UE0 N/AE]YE NE UE N/AZ YZ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 292 of 444 Equipment ID No. SQN-2-LOCL-500-MTR8 E Equip. ClaSS3 20 -Control Panel Equipment Description TURB SUP CONT Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI U[E N/AEI 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE N/AE[YM NEI UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YM NE UE]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 7/31/12 7/31/12 Page 293 of 444 YM NEI- UE-1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-M009 Equip. Class 3 20 -Control Panel Equipment Description VENT-ICE CONT-REACT BD Location: Bldg. Control Floor El. 732 Room, Area 13 -Control Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 1, 2-4 7W605-3, Detail B3.2. Is the anchorage free of bent, broken, missing or loose hardware?Back panels were opened and anchorage to structure was verified Each control room panel consists of one continuous cabinet with multiple Risers. No Riser-to-Riser connections were observed It was noted that adjacent panels were bolted together on the front side of each cabinet-to-cabinet interface.

3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YMNEI Y NE UrE N/AE YZ NE UE N/AEl Y9 NEI UE] N/AE YZ NEI UE N/AE[Y[N NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 294 of 444 Equipment ID No. SQN-2-LOCL-500-MescrEquip0O .1 Equip. Class' 20 -Control Panel Equipment Description VENT-ICE CONT-REA CT BD Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YX NEI U1: N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z NrE- UrE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NE UE N/AT YER NEI Ui Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y[ NEI U0 adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/31/12 Phillib York 7/31/12 Page 295 of 444 Sta.tu: YZ NE U0 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PNLA-082-TV/3-A Equip. Class 3 20 -Control Panel Equipment Description DG 2A-A CONTROL PNL Location: Bldg. DG Floor El. 722 Room, Area I -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE:] N[Z of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?Back and front panels were opened and anchorage to structure and surrounding panel was verified One of eight anchor bolts was missing in the cabinet-to-cabinet connection.

This is not deemed seismically adverse.3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NE UEI N/AE Y[ NE UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y] NEI UE1 N/AE [5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AIK YN NEUE3 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 296 of 444 Equipment ID No. SQN-2-PNLA-082-TVR3-A E s Equip. Class:3 20 -Control Panel Equipment Description DG 2A-A CONTROL PNL Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE1 N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UO N/AEF and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE N/AEl YX NO UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NO U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/18/12 Phillit York 7/18/12 Page 297 of 444 St.tus: YM NO UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-O-HEX-078-0018 Equip. Class 3 21 -Heat Exchanger Equipment Description SPENT FUEL PIT HEAT EXCHANGER A Location: Bldg. Aux Floor El. 714 Room, Area 29 -SFP HEX Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 151-0287-6-01.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

Per drawing, the anchor bolts of one support saddle are supposed to be"backed up slightly ". This does not seem to have occurred. However, per calc CEB-CQ5-406 R4, the required displacement is onlv 0. 04".Given such a small displacement, the saddle should be able to flex adequately to meet the requirements.

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI YN NO UE N/A-1E Y 1 N E- UE-1 N/AE-1 Y1 NEI UD N/AE YN NEI U- N/AE[YN NEI U-3 Enter the equipment class name from Appendix B: Classes of Equipment Page 298 of 444 Equipment ID No. SQN-O-HEX-078-0018 Equip. ClaSS3 21 -Heat Exchanger Equipment Description SPENT FUEL PIT HEAT EXCHANGER A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI Ur N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YCK NO U0 N/AE Y[N NEI U Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YIZ NO U0 adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 8/2/12 8/2/12 Page 299 of 444 St.t.t: YY NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-HEX-072-0007 Equip. Class 3 21 -Heat Exchanger Equipment Description CNTMT SPRAY HT EXCH 2B Location: Bldg. Aux Floor El. 690 Room, Area 39 -2B RHR CCS HEX Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoragze

1. Is the anchorage configuration verification required (i.e., is the item one YZ NE of the 50% of SWEL items requiring such verification)?

For anchorage configuration verification see drawings 2-48N1231 and F-6662-2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NEI UE N/AD Y[ NE UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YZ NEI UE N/AE YIZ NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 300 of 444 Equipment ID No. SQN-2-HEX-072-0007eEquip.io Equip. Class' 21 -Heat Exchanqer Equipment Description CNTMT SPRAY HT EXCH 2B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NO U[ N/AE7 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[l NEI UE N/AE]and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI Ur N/AENEI U-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U I adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/7/12 Phillip York 8/7/12 Page 301 of 444 S.tatu: Y NE-I UN E Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-HEX-072-0030 Equip. Class 3 21 -Heat Exchanger Equipment Description CONTAINMENT SPRAY HEAT EXCHANGER 2A Location: Bldg. Aux Floor El. 690 Room, Area 42- 2A RHR CCS HEX Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Wallkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y Z NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawings 2-48N1231 and F-6662-2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NE UE] N/AE Yr NE UEr N/AE1 YM NE UE N/AE YN NEI UEr N/AEr YN NEI UEr 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 302 of 444 Equipment ID No. SQN-2-HEX-072-0030 Equip. ClasS3 21 -Heat Exchanger Equipment Description CONTAINMENT SPRA Y HEA T EXCHANGER' 2A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Yr NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Yr NF] UEr N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE N/A[YONDU-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NE UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/2112 Phillip York 8/2112 Page 303 of 444 Status: YZ NEI UE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-HEX-074-0015 Equip. Class 3 21 -Heat Exchanger Equipment Description RESIDUAL HEAT EXCHANGER 2A Location: Bldg. Aux Floor El. 690 Room, Area 42 -2A RHR CCS HEX Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YZ NO of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 2-48N1231.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with'plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NEI UErTN/AE Y[l NEI UE N/A-YN NEI UEr N/A]YCK NE UE N/AE1 Y5 NEI UE]3 Enter the equipment class name from Appendix B: Classes of Equipment Page 304 of 444 Equipment ID No. SQN-2-HEX-074-D1A 5 Eq Ce Equip. ClasS3 21 -Heat Exchanger Equipment Description RESIDUAL HEAT EXCHANGER 2A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[ NE UE7 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ UE N/AO and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE N/AE[YN NE U17 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Isaac Antanaitis Date: 8/15/12 Phil/in. York 8/15/12 Page 305 of 444 St.t.t: YY NO UEr Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-HEX-074-0027 Equip. Class 3 21 -Heat Exchanqer Equipment Description RESIDUAL HEAT EXCHANGER 2B Location: Bldg. Aux Floor El. 690 Room, Area 39 -2B RHR CCS HEX Room Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y[ NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing 2-48N1231.

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Y[] NEI UE N/AE[YN NEI U- N/AEl 4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y[ NEI UE N/AE1 Y[ NE UE3 3 Enter the equipment class name from Appendix B: Classes of-Equipment Page 306 of 444 Equipment ID No. SQN-2-HEX-074-0027 Eq Ce Equip. ClaSS3 21 -Heat Exchanger Equipment Description RESIDUAL HEAT EXCHANGER 2B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE- N/ArT 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y 0 N E- UrE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NE UE7 N/AE Y[ NEI UEI Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y[N NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/7112 Phillip York 8/7/12 Page 307 of 444 Status: YN NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TNK-070-0063 Equip. Class 3 21 -Tank Equipment Description CCS SURGE TANK B Location: Bldg. Aux Floor El. 734 Room, Area 32 -Surge Tank B Area Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one Y N NEI of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing ISI-022 7-B-01.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation? YX NE UE N/AE YN NEI UE1 N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YCK NE UE N/AE[YNNEIUO 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 308 of 444 Equipment ID No. SQN-2-TNK-070-0063 Ei Equip. ClaSS3 21 -Tank Equipment Description CCS SURGE TANK B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures?"Tank level Transmitter "piping is approximately

1. 5 "from ductwork near equipment.

For the duct to deflect this distance, it would need to"crumple" at the nearest restraint location. Given that the HVA C system is designed for seismic loads, this was not considered seismically adverse.Y Z NE] UrE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y M N E UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YZ NEI UE- N/AE]Y[K NEI UE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y Z NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 8/6/12 Phillib York 8/6/12 Page 309 of 444 S t a t us. :YNNO UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TNK-082-0224 Equip. ClassS 21 -Tank Equipment Description DSL 2A 1 STARTING AIR TANK A 35 CF Location: Bldg. DG Floor El. 722 Room, Area 1 -Bay 2A Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawinglON320-2, Detail E2.2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?.YZ NO YN NO UO N/A-YN NEI UE N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE N/AE1 YN NEI UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 310 of 444 Equipment ID No. SQN-2-TNK-082-0224 Equip. ClaSS3 21 -Tank Equipment Description DSL 2A1I STARTING AIR TANK A 35 CF Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YIC N0 U-1 N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UE] N/AE and masonry block walls not likely to collapse onto the equipment? Trapeze support above equipment could have interaction with the piping and tank during a seismic event. This interaction should not be adverse and is not considered seismically significant.

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NEI UE N/AE YCK NEI U-1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NE1U -adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/16/12 Phillib York 7/16/12 Page 311 of 444 S t a t u. Y1 :YNEIUE1 Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TNK-082-0255 Equip. Class 3 21 -Tank Equipment Description DSL 2B2 STARTING AIR TANK A 35 CF Location: Bldg. DG Floor El. 722 Room, Area 4 -Bay 2B Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one NE of the 50% of SWEL items requiring such verification)? For anchorage configuration verification see drawing] 0N320-2, Detail E2.2. Is the anchorage free of bent, broken, missing or loose hardware?3.. Is the anchorage free of corrosion that is more than mild surface oxidation? YN NEI UE N/AE Y[ NEI UE7 N/A[4. Is the anchorage free of visible cracks in the concrete near the anchors? YM NEI UE] N/AE 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

Y!N NEI UE N/AE1 Y[N NE UE 3 Enter the equipment class name from Appendix B: Classes of Equipment Page 312 of 444 Equipment ID No. SQN-2-TNK-082-0255 Equip. Class3 21 -Tank Equipment Description DSL 282 STARTING AIR TANK A 35 CF Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y M NE: UEl N/A[E 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YN NEI UE7 N/AE[and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y 0 Nr-E U E- N/AE]Y[ NO UEr Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y M NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 7/23/12 Phillio York 7/23/12 Page 313 of 444 Status: YER NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-063-0090 Equip. Class' 7 -Air Operated Valve Equipment Description S/S ACCUM TK 3 FLOW ISOLATION VLV Location: Bldg. Reactor Floor El. 693 Room, Area 46 -Accum. Rm 3 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraze 1. Is the anchorage configuration verification required (i.e., is the item one YE[ NI of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE[ NEI UE N/AN YE NEI UE-] N/AZ YE NEI UE N/AZ YE NE UE N/A1Z YN NO UE' Enter the equipment class name from Appendix B: Classes of Equipment Page 314 of 444 Equipment ID No. SQN-2-FCV-063-0090 Equip. Class' 7 -Air Operated Valve Equipment Description S/S ACCUM TK 3 FLOW ISOLATION VLV Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YX NEI UE1 N/AE-8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y 0 N E U E N/A E and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE-- N/AEI Y[ NE UE-Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 PhiliI York 11/9/12 Page 315 of 444 Status: YM NEI UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2 -PS V-001-0013B-B Equip. Class' 8 -Solenoid Operated Valve Equipment Description SG 2 MAIN STM HOR PRESS Location: Bldg. Reactor Floor El. 747 Room, Area 50 -Annulus AZ 277 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE N/AO YE NE UE1 N/A9 YE NEI UE1 N/AN Y[E NEl UE N/A[C YZ NEI UE 1 Enter the equipment class name from Appendix B: Classes of Equipment Page 316 of 444 Equipment ID No. SQN-2 -PSMV-1-0013B-B HE Equip. Class' 8 -Solenoid Operated Valve Equipment Description SG 2 MAIN STM HDR PRESS Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y Z N El U El N/A El and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI U- N/AEI YN.NE UE1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YER NEI Ur adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 317 of 444 Status: YN NE UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-PSV-O01-0024A-A Equip. Class, 8 -Solenoid Operated Valve Equipment Description SG 3 MAIN STM HDR PRESS Location: Bldg. Reactor Floor El. 747 Room, Area 50 -Annulus AZ 277 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NM]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE] NEI U N/AZ YE NEI UE N/ACK 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE NE UE N/AZ 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NEI UE N/AIE YNEIUE' Enter the equipment class name from Appendix B: Classes of Equipment Page 318.of 444 Equipment ID No. SQN-2-PSV-GS1-0024A-A Eqe Equip. Class, 8 -Solenoid Operated Valve Equipment Description SG 3 MAIN STM HDR PRESS Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y 0 N E] UE N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y[Z NrE- U E- N/AEl and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y I NEl U D N/AE YN NO UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U[-adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 319 of 444 Status: YZ NEI UE-]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-FCV-063-0118 Equip. Class' 8 -Motor Operated Valve Equipment Description SIS ACCUM TK I FLOW ISOLATION VLV Location: Bldg. Reactor Floor El. 693 Room, Area 48 -Accum. Rm I Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments.and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE NE UE N/AH YE NEI UE N/AN 4. Is the anchorage free of visible cracks in the concrete near the anchors? YE NEI U N/A Z 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YO NO UE N/AN Y[ NE U[E 1 Enter the equipment class name from Appendix B: Classes of Equipment Page 320 of 444 Equipment ID No. SQN-2-FCV-063-0118 Equip. Class, 8 -Motor Operated Valve Equipment Description SIS ACCUM TK I FLOW ISOLATION VLV Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YE NEI UE N/AEq 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ No UO N/A[]and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?Threaded attachment on flex hose was found to be unattached.

Minor maintenance request.10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NEI UE- N/AE Y[R NEI UO Other Adverse Conditions

11. Have you looked for and found no other seismic conditions that could YER NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillio York 11/9/12 Page 321 of 444 Status: YZ NO UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-AHU-030-0080 Equip. Class' 10 -Air Handling Unit Equipment Description CONTROL ROD DRIVE COOLING UNIT D-B Location: Bldg. Reactor Floor El. 680 Room, Area 51 -Inside Polar Crane Wall Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one Y [] N Z]of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YZ NE UE1 N/AE YN NEI UE[ N/AE[4. Is the anchorage free of visible cracks in the concrete near the anchors? YN NE UE] N/AE[]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE] UE N/AER YZNEUE' Enter the equipment class name from Appendix B: Classes of Equipment Page 322 of 444 Equipment ID No. SQN-2-AHU-030-0080 Equip. Class' 10 -Air Handlinq Unit Equipment Description CONTROL ROD DRIVE COOLING UNIT D-B Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YZ NEI U0 N/All 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NE UE N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YM NO UE N/AE YM NEI Ur Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YIR NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 PhiliiD York 11/9/12 Page 323 of 444 Status: YE] NM U0]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-AHU-030-0088 Equip. Class' 10 -Air Handlinq Unit Equipment Description CONTROL ROD DRIVE COOLING UNIT C-A Location: Bldg. Reactor Floor El. 680 Room, Area 51 -Inside Polar Crane Wall Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE] NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?One (of six) bolt was missing from equipment to steel supporting frame.3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YE] NX UE] N/AE]YZ NE] UE] N/AE]4. Is the anchorage free of visible cracks in the concrete near the anchors? Y N NE] U E] N/A E]5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YO NE] UE N/AM YCKNO]UE]1 Enter the equipment class name from Appendix B: Classes of Equipment Page 324 of 444 Equipment ID No. SQN-2-AHU-030-0088 Equip. Class, 10 -Air Handlinq Unit Equipment Description CONTROL ROD DRIVE COOLING UNIT C-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI UE[ N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YM NO UE N/AE-and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI Urn N/AE YZ NE U1 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 11/9/12 11/9/12 Page 325 of 444 Status: YN NEI UE Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-AHU-313-0262 Equip. Class, 10 -Air Handling Unit Equipment Description INCORE INSTR RM AHU A Location: Bldg. Reactor Floor El. 708 Room, Area 52 -Incore Inst Room Platform Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?This AHU sits on steel grating on an elevated plafformn.
5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/A E YN NEI UE N/AE-YE NE UE- N/AZ YE NEI UE N/A[R YN NE UE-]1 Enter the equipment class name from Appendix B: Classes of Equipment Page 326 of 444 Equipment ID No. SQN-2-AHU-313-0262 Equipment Description INCORE INSTR RM AHU A Equip. Class' 10 -Air Handlinq Unit Interaction Effects 7. Are soft targets free from impact by nearby equipment .or structures? YM NEI Ur N/AO 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NO UO N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NE UV: N/AO YM NO UO Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NO U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 327 of 444 Status: YN NE UL]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-CLR-030-0074 Equip. Class, 10 -Cooler Equipment Description REACTOR LOWER COMPT COOLING UNIT A-A Location: Bldg. Reactor Floor El. 693 Room, Area 47 -Fan Room I Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchora2e 1. Is the anchorage configuration verification required (i.e., is the item one YE NN of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

Minor corrosion found on anchorage. Not considered significant.

4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6; Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions? YZ NE UE N/AE Y[Z NE U[El N/AE YZ NEI UE N/AE]YE NED UE- N/A YN NE UE]' Enter the equipment class name from Appendix B: Classes of Equipment Page 328 of 444 Equipment ID No. SQN-2-CLR-030-0074 Equip. Class' 10 -Cooler Equipment Description REACTOR LOWER COMPT COOLING UNIT A-A Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YN NEI U1: N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YN NEI UO N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y[ NO UE1 N/AO YZ NE UEI Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could YZI NEI UE adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 329 of 444 Status: YM NEI UE]Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-LOCL-500-0183C Equip. Class1 18 -Instrument Rack Equipment Description FLOOR PANEL REACTOR BUILDING Location: Bldg. Reactor Floor El. 693 Room, Area 47 .. Fan Room 1 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchoraze 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?
4. Is the anchorage free of visible cracks in the concrete near the anchors?5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)
6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YN NEI UE- N/AE YZ NEI UE[ N/AEI Y[E NEI UE- N/AE-1 YE NEI UE N/A[E YN NEI UE[1 Enter the equipment class name from Appendix B: Classes of Equipment Page 330 of 444 Equipment ID No. SQN-2-LOCL-500-0183C EUIp s Ir R Equip. Class, 18 -Instrument Rack Equipment Description FLOOR PANEL REACTOR BUILDING Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? YER NEI UE N/AD 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, Y M NE7 UE] N/AE and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE[ N/AE YX NEI UE Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U E adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillib York 11/9/12 Page 331 of 444 Status: YM NEI UE[Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TNK-063-0060 Equip. Class, 21 -Tank Equipment Description SIS ACCUMULATOR NO 4 Location: Bldg. Reactor Floor El. 693 Room, Area 49 -- Accum. Rm 4 Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results of judgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorage 1. Is the anchorage configuration verification required (i.e., is the item one YE] NZE of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NE UE1 N/AE YZ NEI UE- N/AE 4. Is the anchorage free of visible cracks in the concrete near the anchors? Y Z ND U[E N/A[-5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE[ NE UE N/AN YX NO UE 1 Enter the equipment class name from Appendix B: Classes of Equipment Page 332 of 444 Equipment ID No. SQN-2-TNK-063-0060IEqup.U Equip. Class' 21 -Tank Equipment Description SIS ACCUMULATOR NO 4 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y[K NO UE N/AE7 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YR NEI U- N/A-and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?Y M NrE U El N/AE YSK NEI U0 Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y N NEI U E]adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Date: 11/9/12 Phillin York 11/9/12 Page 333 of 444 Status: YCK NEI UE: Seismic Walkdown Checklist (SWC)Equipment ID No. SQN-2-TNK-063-0119 Equip. Class' 21 -Tank Equipment Description SIS ACCUMULATOR NO 1 Location: Bldg. Reactor Floor El. 693 Room, Area 48 -Accum. Rm I Manufacturer, Model, Etc. (optional but recommended) Instructions for Completing Checklist This checklist may be used to document the results of the Seismic Walkdown of an item of equipment on the SWEL. The space below each of the following questions may be used to record the results ofjudgments and findings. Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable Anchorane 1. Is the anchorage configuration verification required (i.e., is the item one YE NZ0 of the 50% of SWEL items requiring such verification)?

2. Is the anchorage free of bent, broken, missing or loose hardware?3. Is the anchorage free of corrosion that is more than mild surface oxidation?

YN NEI UE N/AE]YN NE UE N/AE]4. Is the anchorage free of visible cracks in the concrete near the anchors? YZ NEI UE N/AE1 5. Is the anchorage configuration consistent with plant documentation?(Note: This question only applies if the item is one of the 50% for which an anchorage configuration verification is required.)

6. Based on the above anchorage evaluations, is the anchorage free of potentially adverse seismic conditions?

YE NE UE N/AZ YER NE UE1 1 Enter the equipment class name from Appendix B: Classes of Equipment Page 334 of 444 Equipment IDeNo. SQN-2-TNK-063-I1A19 E .s -Equip. Class, 21 -Tank Equipment Description SIS ACCUMULATOR NO 1 Interaction Effects 7. Are soft targets free from impact by nearby equipment or structures? Y19 NEI UE- N/AE 8. Are overhead equipment, distribution systems, ceiling tiles and lighting, YZ NEI UEJ N/AE]and masonry block walls not likely to collapse onto the equipment?

9. Do attached lines have adequate flexibility to avoid damage?10. Based on the above seismic interaction evaluations, is equipment free of potentially adverse seismic interaction effects?YN NEI UE- N/AD YER NEI UE[Other Adverse Conditions
11. Have you looked for and found no other seismic conditions that could Y X NO UO adversely affect the safety functions of the equipment?

Comments (Additional pages may be added as necessary) Evaluated by: Robert Malone Phillip York Date: 11/9/12 11/9/12 Page 335 of 444 Appendix F: AWCs The following signatures are provided for the engineers responsible for the Area Walk-By Checklists in Sequoyah Unit 2.Name Signature Date Isaac Antanaitis,- James Edgar 111 1211//Robert Malone /Steven Summers i/liz / / ..Phillip York /4 ,% ,i-r7, 201_Page 336 of 444 Status: Y[ N[-] U[-Area Walk-By Checklist (AWC)Location: Bldg. DG Floor El. 722 Room, Area 4 I -Bay 2A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YE NEI UE- N/A[2. Does anchorage of equipment in the area appear to be free of significant Y[D N[] U- N/AZ]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NZI UZI N/AZl YZ NEI UZ] N/AZ1 4 Itfthe room in which the SWEL item Is located 1. vry, arge (e.g.. Turbine Hai I), th. are. selected should be described. This Selected area shou Id be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 337 of 444 Location: Bldg. DG Floor El. 722 Room, Area 4 1 -Bay 2A 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Eye wash tank needs to be restrained. During a seismic event it could tip and could cause spray. The eye wash tank was observed to be restrained during a later inspecton.

6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

Scaffolding was found in the area. The inspection tags are current and are dated to be removed 7-19-12.YM NE UE N/AEl YO NE1 UE- N/AEl YED N[ UE3 N/AEl 8. Have you looked for and found no other seismic conditions that could YZ NEl UiE adversely affect the safety functions of the equipment in the area?A washer was missing from one of the anchor bolts on the DG engine.This is not considered to be seismically adverse.Comments (Additional pages may be added as necessary) The SWEL items are included in the area encompassed by this Area Walk-By: 2-FCV-067-0066 2-XSW-082-UH-A 2-GENB-082-0002A 2-FCV-067-0068 2-BATB-082-UD-A 2-PNLA-082-TV /3-A 2-CMP-082-0240 2-CHGB-082-TZ 2-TNK-082-0224 2-CMP-082-0241 2-ENG-082-0002A1 2-PNLA-082-TV-A 2-ENG-082-0002A2 Evaluated by: Robert Malone Date: 7/18/12 Phillip York 7/18/12 Page 338 of 444 Status: YO Ni] UE-]Area Walk-By Checklist (AWC)Location: Bldg. DG Floor El. 740 Room, Area 4 2 -2A Board Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y[D NEI UEI N/AZ-YE NEI U[i N/AZ1 YZ NEI UZ] N/AZ3 YV NO UI- N/AEZ 4 If the room in which the SWEL item is located Is very large (e.g., Turbine Hall), the area selected should be d ... ribed.This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 339 of 444 Location: Bldg. QG Floor El. 740 Room, Area4 2 -2A Board Room Location: Bldg. DG Floor El. 740 Room, Area 4 2 -2A Board Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YED NEI UI- N/AE3 YE NEI ULI N/AE YED NEI UE-I N/AEl 8. Have you looked for and found no other seismic conditions that could YZ NEI UE-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The SWEL items are included in the area encompassed by this Area Walk-By: 2-BDC-201-FQ-A Evaluated by: Robert Malone Date: 7-18-12 Phillip York 7-18-12 Page 340 of 444 Status: YZ N[- UIýArea Walk-By Checklist (AWC)Location: Bldg. DG Floor El. 740 Room, Area 4 3 -2A Fan Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

It was noted that a few of the HVAC supports attached to the ceiling had at first appeared to have missing bolts. The HVAC base plates consisted of a 4 bolt pattern plate bolted to the ceiling. Not all of the bolts had been installed. In the location without the bolts the corner of the base plate was welded to an embed plate. In most cases only one bolt was missing. Given that there was a comer weld to account for the missing bolt as well as the robustness of the connection (even when neglecting the weld) compared to the size of the ductwork this is deemed to be acceptable.

2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Same note as shown in question one above.YZ NEI U[I N/AZ YO NEI UL] N/AZ YO NEI UZ N/AZ 4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ N[-] UE- N/AZ 4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on Judgment, e.g., on the order of about 35 feet from the SWEL item.Page 341 of 444 Location: Bldg. QG Floor El. 740 Room, Area4 3 -2A Fan Room Location: Bldg. DG Floor El. 740 Room, Area 4 3 -2A Fan Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YE NEI Ur" N/AL YED N[-] U'- N/AL YO NEI UrI N/AL 8. Have you looked for and found no other seismic conditions that could YS N(-] UM adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-FAN-030-0452 2-FAN-030-0460 2-TE-300-0452A-A 2-TE-300-0452B-A Evaluated by: Robert Malone Date: 7-18-12 Phillip York 7-18-12 Page 342 of 444 Status: Y[ NO U[Area Walk-By Checklist (AWC)Location: Bldg. DG Floor El. 722 Room, Area 4 4 -Bay 2B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI U-I N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YE NEI UE- N/AZl degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YO NEl UZI N/AZ YZ NEI U[Z N/AZl 4 If the roo. In which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on Judgment, e.g., on the order of about 35 feet from the SWEL item.Page 343 of 444 Location: Bldg. DG Floor El. 722 Room, Area 4 4 -Bay 2B 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Trash can does not have a restraint but does not pose any seismic adverse risk.YED NEI UI N/AZ YED NO UI- N/AO YED NO U- N/A[8. Have you looked for and found no other seismic conditions that could YED N- UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-FCV-067-0067 2-CMP-082-0271 2-CHGB-082-UA-B 2-ENG-082-0002BI 2-ENG-082-0002B2 2-GENB-082-0002B 2-LOCL-500-0163 2-TN K-082-0255 Evaluated by: Robert Malone Date: 7/23/12 Phillip York 7/23/12 Page 344 of 444 Status: YO NEI U[-Area Walk-By Checklist (AWC)Location: Bldg. DG Floor El. 740 Room, Area 4 5 -2B Board Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI UE] N/AE-2. Does anchorage of equipment in the area appear to be free of significant YZ NE] U- N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YED NEi UE- N/AE-YZ NEI U[-] N/AE 4 Ifthe roo. in which the SWEL item is located Is very large (e.g., Turbine Hall). the are. selected should be described. This selected erea should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 345 of 444 Location: Bldg. DG Floor El. 740 Room, Area 4 5 -2B Board Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Scaffolding noted in area but has current inspection dates.YZ NEI U[I N/AZ-YO NEI UEZ N/AZ-YE NEI UI- N/A[-8. Have you looked for and found no other seismic conditions that could YED NE3 UM adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDC-201-FU-B Evaluated by: Phillip York Date: 7-24-12 Robert Malone 7-24-12 Page 346 of 444 Status: Y[ No U-Area Walk-By Checklist (AWC)Location: Bldg. DG Floor El. 740 Room, Area 4 6 -2B Fan Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI UI N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YE NEL U-] N/AZ degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is.adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YED NZI U-1 N/AZl YZ NZl U-- N/AZl 4 If the room in which the SWEL iten Is located is v.ery large (e.g., Turbine Hall), the area selected should be described. This selected aree should be based onjudgment, e.g., on the order of about 35 feet from the SWEL item.Page 347 of 444 Location: Bldg. DG Floor El. 740 Room, Area 4 6 -2B Fan Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YE NEI UI- N/AEl YS NEI UE- N/AZ YO NEI UW N/AZ 8. Have you looked for and found no other seismic conditions that could YO NEI U-1 adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-FAN-030-0450-B 2-FAN-030-0462-B 2-TE-300-0450A-B 2-TE-300-0450B-B Evaluated by: Robert Malone Date: 7-24-12 Phillip York 7-24-12 Page 348 of 444 Status: Y[-] No U[-Area Walk-By Checklist (AWC)Location: Bldg. ERCW Floor El. 720 Room, Area 4 7- 2A Pump Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI U[I- N/AZ-2. Does anchorage of equipment in the area appear to be free of significant YE NEI UI] N/AZ degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YN NEI Ur- N/AE-4. Does it appear that the area is free of potentially adverse seismic spatial YZ NZI UZ- N/AZ interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room in which the SWEL item is located is very large (e.g., Turbine Ha 5 l), the area selected should be described. This selected area should be based on Judgment, e.g., on the order of about 35 feet from the SWEL item.Page 349 of 444 Location: Bldg. ERCW Floor El. 720 Room, Area 4 7- 2A Pump Room 5. Does it appear that the area is free of potentially adverse seismic YS NEI UE- N/AZ interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic YI--] ND UrI N/AZ-interactions that could cause a fire in the area?Flammable material cabinet had a broken latch so the door would not stay closed. The cabinet was also not anchored.7. Does it appear that the area is free of potentially adverse seismic YS NEI Ur1 N/AZ interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? A welding machine was located within approximately 12" of the flexible electrical conduit coming out of the floor up to the pump. The wheels of the welding machine were restrained using a C-Clamp on both rear wheels. This was not considered seismically adverse.8. Have you looked for and found no other seismic conditions that could YS N--] Ur adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following SWEL items are included in the area encompassed by this Area Walk-By:.0-PMP-067-0464 0-PM P-067-0487-A Evaluated by: Robert Malone Date: 7-19-12 PhilliD York 7-19-12 Page 350 of 444 Status: Y[ NE] U['Area Walk-By Checklist (AWC)Location: Bldg. ERCW Floor El. 704 Room, Area 4 8 -2A Board Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YE NEI Uil N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YZ N[] U[-] N/AZ]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Florescent lights do not have cages.YO NE! UZ N/AZ3 YZ NEI UEZ N/AZ1 4 Ifthe room In which the SWEL item is located is very large (e.g., Turbi.e Hall), the area. selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL Item.Page 351 of 444 Location: Bldg. ERCW Floor El. 704 Room, Area 4 8 -2A Board Room 5. Does it appear that the area is free of potentially adverse seismic YZ NEI ULI N/AlI interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic YN NE] U-- N/All interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic YZ NEI U[ZI N/AlZ interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Unrestrained ladder in area but not near any equipment.

8. Have you looked for and found no other seismic conditions that could YZ NEI UEl adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

The following equipment is included in the area encompassed by this Area Walk-By: 2-BDC-201-FL-A 2-XFA-202-0312 Evaluated by: Robert Malone Date: 7-19-12 Phillip York 7-19-12 Page 352 of 444 Status: Y[ N[-J UE[Area Walk-By Checklist (AWC)Location: Bldg. ERCW Floor El. 688 Room, Area 4 9 -2A Strainer Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y0 NEI U-] N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YD NE] U-- N/AZ degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NEI UZ] N/AZ YE NEI U[Z N/AZl 4 If the roo. In which the SWEL item is located is very Iarge (e.g., Turbine Hall), the area selected should be described. ThIs selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 353 of 444 Location: Bldg. ERCW Floor El. 688 Room, Area4 9 -2A Strainer Room Location: Bldg. ERCW Floor El. 688 Room, Area 4 9 -2A Strainer Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YS NEI ULI N/AEl YN NEl UI1 N/AZl YS NEl UI-] N/AZ 8. Have you looked for and found no other seismic conditions that could YED NI-] U-1 adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-FCV-067-0492 Evaluated by: Robert Malone Date: 7-19-12 Phillip York 7-19-12 Page 354 of 444 Status: YE N[-- U[--Area Walk-By Checklist (AWC)Location: Bldg. ERCW Floor El. 720 Room, Area 4 10 -2B Pump Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appearto be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NEI UI- N/AE-YZ NEi U" N/AEl YN N[l UE] N/All YZ NEI U[l N/AZ 4 If the roo. in which the SWEL item Is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g.. on the order of about 35 feet from. the SWEL item.Page 355 of 444 Location: Bldg. ERCW Floor El. 720 Room, Area 4 10 -2B Pump Room 5. Does it appear that the area is free of potentially adverse seismic YS NEI Ur- N/AZ interactions that could cause flooding or spray in the area?The ERCW pump 0-MTRA-67-456-B is leaking at the shaft/pipe interface. The pump had been roped off and appears to be in the process of being fixed.6. Does it appear that the area is free of potentially adverse seismic YED NEI Ur- N/AZ-interactions that could cause a fire in the area?It was noted that a fire extinguisher was not restrained and could easily fall out of its box during a seismic event. It is not near any equipment so it does not pose any significant risk.7. Does it appear that the area is free of potentially adverse seismic YS NE U-- N/AZ interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could YO N[] U[-]adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

The following equipment is included in the area encompassed by this Area Walk-By: O-PM P-067-0452 O-PM P-067-0482-B Evaluated by: Robert Malone Date: 7/24/12 Phillip York 7/24/12 Page 356 of 444 Status: NEl U[-Area Walk-By Checklist (AWC)Location: Bldg. ERCW Floor El. 704 Room, Area 4 11 -2B Board Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

.3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)? YO NEI UI- N/AEl YO NEI UI- N/AEZ YED NEI UI- N/A--YO NEI U- N/AZ 4 If the room In which the SWEL Item is located is .very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on Judgment, e.g., on the order of about 35 feet from the SWEL Item.Page 357 of 444 Location: Bldg. ERCW Floor El. 704 Room, Area4 11 -2B Board Room Location: Bldg. ERCW Floor El. 704 Room, Area 4 11 -28 Board Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?Concrete seepage noted in some locations. Not a significant enough source of water to cause flooding.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Computer cabinet restrained to transformer frame with rope. SRO advised that this was an approved method of restraint. YN NE] U[-] N/AZ YS NEI U[I N/AZ YM NE] UZ- N/A[8. Have you looked for and found no other seismic conditions that could YZ NEI] Ur]adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) Minor mineral staining in various locations. No areas of leakage directly over equipment. Not a significant source of flooding.The following equipment is included in the area encompassed by this Area Walk-By: 2-BDC-201-FN-B 2-XFA-202-0316 Evaluated by: Robert Malone Date: 7-24-12 Phillip York 7-24-12 Page 358 of 444 Status: Y[ Nn] U[Area Walk-By Checklist (AWC)Location: Bldg. Control Floor El. 732 Room, Area 4 12 -Control Mechanical Equip Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI ULI N/AZl 2. Does anchorage of equipment in the area appear to be free of significant YO NOL UEI N/All degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YED NZI U[l N/AZl YE NZI Uil N/AZ 4 If the room in which the SWEL item is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment e. g., on the order of about 35 feet from the SWEL item.Page 359 of 444 Location: Bldg. Control Floor El. 732 Room, Area 4 12 -Control Mechanical Equip Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?There is a oil bottle without a cap. However the bottle is tied up in a manner that should prevent any spills.7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NEI UZI N/AEl YZ NEI U-1 N/AZl YS NEI U-1 N/All 8. Have you looked for and found no other seismic conditions that could YZ NEI Ur-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: O-AHU-311-0023 O-CHR-311-0126 Evaluated by: Lance Summers Date: 7-30-12 Phillip York 7-30-12 Page 360 of 444 Status: Y[ N-- U[D Area Walk-By Checklist (AWC)Location: Bldg. Control Floor El. 732 Room, Area 4 13 -Control Room Unit 2 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YM NEI UE] N/AEl 2. Does anchorage of equipment in the area appear to be free of significant YD NEI UEi-] N/AE]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Two fuse cabinets are not restrained and are in close proximity to the control panels. The panels are approximately 2.5'x3'x5' tall. If the panels tipped they would impact the control panel. Credible but not significant, since the potential spatial interaction is with non-safety related equipment. YE] NEI UE] N/Az YZ NO UE- N/AL 4 If the roo. In which the SWEL item is located is very Ia rge (e.g., Turbine Hall). the area selected should be described. This selected area should be based on judgment. e.g., on the order of about 35 feet from the SWEL item.Page 361 of 444 Location: Bldg. Control Floor El. 732 Room, Area 4 13 -Control Room Unit 2 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Step stool unrestrained. Not near panels. Ok.YO NEI U-I N/AZ YN NEI U-1 N/AZ YO NEI UL N/A-1 8. Have you looked for and found no other seismic conditions that could YI NEI UZI adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: O-LOCL-500-M026D 2-LOCL-500-M002 2-LOCL-500-M004 2-LOCL-500-M008 2-LOCL-500-M009 Evaluated by: Robert Malone Date: 7-31-12 Phillip York 7-31-12 Page 362 of 444 Status: YN NEI UM-Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 14 -125V Batt Board Room II Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YO NEI Ur- N/AZ YN NEI U- N/AZl YN NE] UE- N/AZl YED NEI U-- N/AEl 4 If the room in which the SWEL item is located Is very large (e.g., Turbine Hail), the area selected shouId be described. This selected area shou Id be based on judg met, e.g., on the order of about 35 feet from the SWEL item.Page 363 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 14 -125V Batt Board Room //5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Scaffolding was found in the area and has current inspection date.YZ NEI ULI N/AE3 YN NEI UE' N/All YZ NEI UEI- N/A[l 8. Have you looked for and found no other seismic conditions that could YtD NEI U-I adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDE-250-NF-E Evaluated by: Robert Malone Date: 7/26/12 Jim Edqar 7/26/12 Page 364 of 444 Status: Y[ N[J U-]Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 15.. 480V Shutdown Board Room 2A2 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Unistrut pipe strap has a gap on one side but does appear to have been tightened as much as possible. This is ok per TVA documentation. YO NEI UE] N/AEl 2. Does anchorage of equipment in the area appear to be free of significant YO NI] UE- N/AO degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YO NEI U[_] N/AEl YZ NE: UE] N/AEl 4 If the room In which the SWEL item is located Is very large (e.g., Turbine HalI). the area selected should be described. This @elected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 365 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 15 -480V Shutdown Board Room 2A2 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NEI UI- N/A[]YE NEI U[I N/A--YED NEI UI1 N/AEl 8. Have you looked for and found no other seismic conditions that could YS NEI U[I]adversely affect the safety functions of the equipment in the area?Concrete wall has cracks from floor to ceiling that has been filled in with white caulking.Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDC-201-JK-A 2-BDB-201-DO-A Evaluated by: Robert Malone Date: 7-30-12 Phillip York 7-30-12 Page 366 of 444 Status: YE N[] U--Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 16 -480V Shutdown Board Room 2B1 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI UI-I N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YE NEI U-] N/AZ degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YE NZI UZ- N/AZ YE NEI UZ- N/AZ 4 If the roo. in which the SWEL item Is located Is very large (e.g.,, Turbine Hall). the area selected should be described. This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 367 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 16 -480V Shutdown Board Room 2B1 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Scaffolding was found in the area and has current inspection date.YE NEI U[I N/A[Z Y[D NEI U[[ N/A[Z YE N[E] U[:] N/A[Z 8. Have you looked for and found no other seismic conditions that could YZ NEI UE-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDB-201-DP-B Evaluated by: Robert Malone Date: 7/26/12 Jim Edqar 7/26/12 Page 368 of 444 Status: Y[ N[- UL-Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 17 -480V Shutdown Board Room 2B2 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YZ NEI U[-1 N/AEl 2. Does anchorage of equipment in the area appear to be free of significant YN NEI UE- N/AZ3 degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YO NEI UZ-1 N/AZ-YED NEI Ur-Z N/AZ 4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from. the SWEL item.Page 369 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 17- 480V Shutdown Board Room 2B2 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Two ladders in room tied off to cable tray. Knee boards on cable tray.No adverse seismic condition found.YS N[] UI-1 N/AZ YED NEI UE] N/Ar-YS NEI UI- N/AZl 8. Have you looked for and found no other seismic conditions that could YE NEI UMl adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDB-201-DQ-B Evaluated by: Robert Malone Date: 7/26/12 Jim Edgar 7/26/12 Page 370 of 444 Status: YO NJ" U[-Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 18- 480V Transformer Room 2B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NEl U-] N/AE1 2. Does anchorage of equipment in the area appear to be free of significant YO NEl U-] N/AlO degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ NEI Ur] N/AE-Y[0 NEI UE] N/Al]4 If the roo. In which the SWEL item is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on Judgment, e.g., on the order of about 35 feet from the SWEL item.Page 371 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 18 -480V Transformer Room 2B 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Scaffolding in area. Inspection tag is current. Wheels locked.YO NE3 U[-I N/A[-]YO NEI UI- N/A[-Z YED NEI Ur] N/AZ 8. Have you looked for and found no other seismic conditions that could YE NEI UIM-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-OXF-202-2B-B 2-OXF-202-DQ-B Evaluated by: Robert Malone Date: 7/26/12 Jim Edgar 7/26/12 Page 372 of 444 Status: Y[ N- U[-]Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 19- 480V Transformer Room 2A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YE NEI UL] N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YN NE] U- N/AL degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ NEI U-' N/AZ1 YZ NEI UZl N/AZ 4 If the room in which the SWEL item Is located is very large (e.g., Turbine Hall), the area selected should be described. This selected ares should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 373 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 19 -480V Transformer Room 2A 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NEI U-1 N/AZI YS NEI UZ- N/AZ-1 YS NEI U-1 N/A-1 8. Have you looked for and found no other seismic conditions that could YE NEI U--adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-OXF-202-2A-A 2-OXF-202-DN-A Evaluated by: Robert Malone Date: 7-30-12 Phillip York 7-30-12 Page 374 of 444 Status: YE] NZ U[Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 20 -125V Battery Room III Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YZ NiZ U[Z N/A[[2. Does anchorage of equipment in the area appear to be free of significant YI NEI U-] N/AZ degraded conditions?.

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NZI UZ] N/AZ YZ NEI UZl N/AZ 4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 375 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area4 20 -125V Battery Room //Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 20 -125V Battery Room Ill 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?The sink and vanity is not attached to the wall in a manner that is consistent with a seismically qualified restraint. If the sink/vanity broke loose from the wall during a seismic event the water line could cause spray.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic: interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YI- NO U[-I N/A-YO NEI UEI N/AE YE NE-I U[: N/AE-8. Have you looked for and found no other seismic conditions that could YZ NE! U[-]adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) Improper housekeeping practices were noted but would not cause any adverse seismic issues. It should be note that following was observed:* The sink vanity was used to store random garbage.* A space heater with a temporary equipment tag dated 2006 was shoved inside the vanity.* Unlabeled chemicals as well as other chemicals were stored in cabinet.All of the above housekeeping issues listed above were immediately resolved upon discovery. The following equipment is included in the area encompassed by this Area Walk-By: O-BATB-250-QX-F Evaluated by: Robert Malone Date: 7-20-12 Phillip York 7-20-12 Page 376 of 444 Status: Y[- No UM-Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 749 Room, Area4 21 -125V Battery Room IV Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO N[l UL- N/AL-2. Does anchorage of equipment in the area appear to be free of significant YED NEI U' N/AL degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YO NEI UL- N/AL YO NEI UL- N/ALl 4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 377 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area4 21 -125V Battery Room IV 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YED NE U[-1 N/A[YO NE:- UI" N/AL YO NE] U[[] N/AL 8. Have you looked for and found no other seismic conditions that could YD NO UM adversely affect the safety functions of the equipment in the area?Masonry block wall in area has a horizontal crack at the top of the wall near the supporting angle. This crack is approximately 6' long and can be seen on both sides of the masonry block wall Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: O-BATB-250-QY-G Evaluated by: Robert Malone Date: 7-25-12 Phillip York 7-25-12 Page 378 of 444 Area Walk-By Checklist (AWC)Status: YE- NO U--Location: Bldg. Auxiliary Floor El. 749 Room, Area4 22 -480V Board Room 2B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NEI U[] N/AE[2. Does anchorage of equipment in the area appear to be free of significant YO NE] UE" N/AE-degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YI NEI UE- N/AE YE NEI UE] N/AE]4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 379 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area4 22 -480V Board Room 2B 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YO NEI UE" N/A[-YO NEI UL- N/AE-YO NE] UL' N/A[--8. Have you looked for and found no other seismic conditions that could YEI NO U'-adversely affect the safety functions of the equipment in the area?Masonry block wall in area has a horizontal crack at the top of the wall near the supporting angle. This crack is approximately 6' long and can be seen on both sides of the masonry block wall Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDC-201-GN-B O-XSW-250-KL-S O-XSW-250-KX-S 0-CHGB-250-QJ-G O-CHGB-250-QK-S 2-INVB-250-QU-G Evaluated by: Robert Malone Date: 7/26/12 Phillip York 7/26/12 Page 380 of 444 Status: YE NE] UZI Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 23 -480V Board Room 2A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI U[] N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YZ N[] U-- N/A[]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NEI UE- N/AZ YI NEI U-- N/A[-Z 4 If the room in which the SWEL item is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based onjudgment, e.g.. on the order of about 35 feet from the SWEL item.Page 381 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 23 -480V Board Room 2A 5. Does it appear that the area is free of potentially adverse seismic YN NI] UI] N/AZ interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic YS Ni] ULi N/AZ interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic YN NI] Ui] N/AZI interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Temporary equipment found in area. Equipment was chained and anchored together and not near any equipment. O.K.8. Have you looked for and found no other seismic conditions that could YED NI] U--adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDC-201-GM-A Evaluated by: Robert Malone Date: 7-30-12 Philip York 7-30-12 Page 382 of 444 Status: YE N[] U[Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 24 -480V 2A Mechanical Equipment Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI U[-1 N/A-]2. Does anchorage of equipment in the area appear to be free of significant YN NEI UI- N/AZl degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NWI UZ- N/AZ3 YN NEI UE] N/A[Z 4 If the room In which the SWEL item is located is very large (e.g.., Turblne HaiI), the area selected should be described. This selected area should be based on judg ment, e.g., on the order of about 35 feet from the SWEL item.Page 383 of 444 Location: Bldg. Auxiliary Floor El. 749 Room, Area 4 24 -480V 2A Mechanical Equipment Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic: interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Ladder and scaffolding in area and has current inspection date.YED NEI U-J N/AZ YN NEI U-I N/A[YN NEI U-1 N/AZ 8. Have you looked for and found no other seismic conditions that could YZ NEI UZ--adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-AHU-313-0488 2-CHR-313-0483 Evaluated by: Robert Malone Date: 7-31-12 Phillip York 7-31-12 Page 384 of 444 Status: YEr- NZ UI--Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 653 Room, Area 4 25 -RHR Pump Room Area Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YO NEI UF1 N/AZ 2. Does anchorage of equipment in the area appear to be free of significant YO NEI- UI- N/AL!degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YED NEI UZ- N/AZl YN NZI U[-- N/AZl 4 If the room in which the SWEL item Is located Is very large (e.g., Turbine Hail), the area selected should be descrIbed. This selected are. should be based on judgment, e.g., on the order of about 35 feet fr om the SWEL item.Page 385 of 444 Location: Bldg. Auxiliary Floor El. 653 Room, Area 4 25 -RHR Pump Room Area 5. Does it appear that the area is free of potentially adverse seismic YO NDI UI- N/AD interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic YO N[-- UD1 N/AZ interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic: YLI NO U[D N/AD interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Barrels holding radioactive material are unstable and not secured. Could tip over and roll into instrumentation panel which supports safetv related instruments. This is deemed a potentially adverse condition. Scaffolding has been inspected and is horizontally tied off to supports at 3 locations. Other minor housekeeping issues were noted but none were considered seismically adverse.8. Have you looked for and found no other seismic conditions that could YO ND] UDq adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following SWEL items are included in the area encompassed by this Area Walk-By: 1, 2-FCV-067-0190-B 1, 2-FCV-067-188 1, 2-LOCL-500-0005

  • Evaluated by: Lance Summers Date: 8/1/12 Isaac Antanaitis 8/1/12 Page 386 of 444 Status: Y 0 N[E UW Area Walk-By Checklist (AWC)Location:

Bldg. Auxiliary Floor El. 669 Room, Area 4 26 -S1 Pump Room 2A Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the f'ollowing questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YX NO U] N/AO 2. Does anchorage of equipment in the area appear to be free of significant Y M N E U-- N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ NE UF N/AW-YZ NEI UW N/AO 4 If the room in which the SWEL item Is located is very large (e.g., Turbine Hall), the .... selected shou.Id be d ... ribed.This selected aree should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 387 of 444 Location: Bldg. Auxiliary Floor El. 669 Room, Area 4 26 -. SI Pump Room 2A 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YZ NE] UE] N/AE YZ ND U- N/AE1 Y Z NE- U El N/AE 8. Have you looked for and found no other seismic conditions that could Y K NEI UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-PMP-063-0010 2-CLR-030-180-A Evaluated by: Robert Malone Date: 8/1/12 Phillip York 8/1/12 Page 388 of 444 Status: Y ] NE] UEl Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 27 -Unit 2 CCS Pump Area Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y 0 NE] UE EN/A[E]2. Does anchorage of equipment in the area appear to be free of significant YM NEI UE] N/AE]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?A few elbow conduit covers were missing. Appendix R work was ongoing in the area. Not considered seismically adverse.YZ NE] UE] N/AE]4. Does it appear that the area is free of potentially adverse seismic spatial YM NE] UE N/AE]interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

A "specialfire barrier" wall was in the area. Wall appeared to be made of dtywall, 10" thick, 15' tall, and 40' long, cantileveredfrom the floor. No soft targets in the area that were not already covered by equipment walkdowns. Further investigation provided evidence that wall was seismically qualified. 4 If the room in which the SWEL Item Is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based onjudgment, e.g., on the order of about 35 feet from the SWEL item.Page 389 of 444 Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 27 -Unit 2 CCS Pump Area 5. Does it appear that the area is free of potentially adverse seismic YM NEI U13 N/AE interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic Y M NE--1 U E- N/AE1]interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic YZ NO UE- N/AE interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)?

8. Have you looked for and found no other seismic conditions that could YM NEI UE[adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

The following equipment is included in the area encompassed by this Area Walk-By: 2-PMP-070-0059-A 2-LOCL-500-0048 Evaluated by: Robert Malone Date: 8/8/12 Phillip York 8/8/12 Page 390 of 444 Status: Y 0 N El U-l1 Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 714 Room, Area 4 28 -Spent Fuel Pool Pump Pit Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NO U- N/AE 2. Does anchorage of equipment in the area appear to be free of significant Y M N E U El N/A D degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YN NE U- N/A-4. Does it appear that the area is free of potentially adverse seismic spatial YIN NEI UE N/AD interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room in which the SWEL item is located is very large (e.g.. Turbine Haii), the area. elected should be described. This selected are. should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 391 of 444 Location: Bldg. Auxiliary Floor El. 714 Room, Area 4 28 -Spent Fuel Pool Pump Pit 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YZ NEI U--N/AE YM NE UEIN/AE YN NEI UE- N/AEl 8. Have you looked for and found no other seismic conditions that could YZ NE UE1 adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 0-PMP-078-0012-A Evaluated by: Robert Malone Date: 8/2/12 Phillip York 8/2/12 Page 392 of 444 Status: Yr0 NWE UI-W Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 714 Room, Area 4 29 -Spent Fuel Pool HEX Area Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Bolt appears to be missing from conduit support. It has likely been moved to miss interaction with rebar. Anchor still has four bolts. This is not considered adverse.Anchor for conduit support in ceiling above instrument rack 1-LOCL-500-0024 appears to have a misaligned spring for a spring nut connection. Spring nut and other hardware appear to be secured to the unistrut so this instance is not deemed adverse.2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?YX NWI UW N/AW]YN NEI UW N/AW YZ NW UO N/AW1 Y M NW UW N/AW1 YN NWI UW N/AE-4 If the room in which the SWEL item Is located is very large (e.g., Turbine Hall), the rea se lected should be described.

This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 393 of 444 Location: Bldg. Auxiliary Floor El. 714 Room, Area 4 29 -Spent Fuel Pool HEX Area 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Scaffolding under elevated platform (for CCS Thermal Barrier Booster Pumps) is well secured to platform support steel.Y[0 NEl- UE N/A E-YCK N7 UE N/AE[Mobile toolbox is chained to scaffolding. Cart is free to roll.This condition is deemed to be credible but insignificant. Spoolpiece toolbox is chained to stair stringer.Checkplate sheet metal is resting against scaffolding. If it were to move in a seismic event, it would slide down the back side of the stair stringer before coming into contact with the spoolpiece toolbox and the adjacent instrument rack with pressure gauges for the Thermal Barrier Booster Pumps.There is a short (approximately 3 )folding ladder on the CCS Thermal Booster Pump platform which is wire-tied to conduit.This is not deemed credible or significant. Scaffolding around/near column A-7 and A-9 appears to be well-braced and is tied off (by wire ties) to stair stringers and support steel braces.8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area.?YZ NEI U-Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 0-PMP-078-0012-A Evaluated by: Lance Summers Date: 8/2/12 Isaac Antanaitis 8/2/12 Page 394 of 444 Status: YE] NO UE]Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 759 Room, Area4 30 -CRDM Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y -Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Bolt is missing from duct support baseplate above 2-GEND-085-DH, Control Rod Drive Generator 2B.YE] NZ UE N/AE 2. Does anchorage of equipment in the area appear to be free of significant YN NE] UO N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Flex conduit is disconnected from conduit above Hydrogen Recombiner SQN-2-PWC-83-002.

Thermostat had broken loose from baseplate and was repaired by A UO during inspection.

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

An Aux air gage, 0-PI-032-01 71, on a run of 3 "piping was observed that could sway into the HVAC duct in the area. This gage is not Safety Related and would not prevent safe shutdown. Not considered seismically adverse.YN NEI UE N/AE]YM NE] U] N/AE 4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 395 of 444 Location: Bldg. Auxiliary Floor El. 759 Room, Area 4 30 -CRDM Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NEI UE N/AE Y E NEI U E- N/A E-Y Z NE1 U El N/AE 8. Have you looked for and found no other seismic conditions that could Y C N E- UEl adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-GEND-085-DG 2-GEND-085-DH Evaluated by: Robert Malone Date: 8/3/12 Phillip York 8/3/12 Page 396 of 444 Status: Y[0 NE UD Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 31 -6.9kV Shtdwn Board Rm A (U2 Side)Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Cabinets in the area had unobservable anchorage. YM NE: UE N/AE 2. Does anchorage of equipment in the area appear to be free of significant Y[R N E UE N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YZ NEI UE N/AE 4. Does it appear that the area is free of potentially adverse seismic spatial YZ NEI UE] N/AEl interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room in which the SWEL ite m is located is v.ery large (e.g., Turbine Hali), the area selected should be described. This selected ares should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 397 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 31 -6.9kV Shtdwn Board Rm A (U2 Side)5. Does it.appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Temporary equipment was properly anchored to permanent conduit support.Y IR NE-] U E- N/A0 YCR NEI UE-1 N/AE YX NEI UE N/AE 8. Have you looked for and found no other seismic conditions that could YZ NEI UE1 adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDA-202-CO Evaluated by: Robert Malone Date: 8/3/12 Phillip York 8/3/12 Page 398 of 444 Status: YE] NIM u-]Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 32 -Surge Tank B Area Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YM NEI U- N/AE:-2. Does anchorage of equipment in the area appear to be free of significant YX NEI UE N/A]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y Z NE] U E- N/AEl YN NE UE] N/AO 4 If the ro.m in which the SWEL item Is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 399 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 32 -Surge Tank B Area 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Rad Protection A V Cabinet lacks proper seismic restraint. Cabinet has two eye hook restraints but only one is in use.YM NE UE-N/AE1 YZ NEI UE N/AE YE1 NM UEN/AEI 8. Have you looked for and found no other seismic conditions that could YN NE UE adversely affect the safety functions of the equipment in the area?The posts supporting the two sets of stairs to the elevated office are poorly anchored. The posts are not anchored to the floor and bolts are missing between the posts and upper platforms. A temporary ganty crane, with locked wheels, is anchored to one of these posts. Since there is no equipment related to safe shutdown or operations in the area, this issue is not considered seismically adverse.Comments (Additional pages maybe added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 0-DRYA-032-0002-B 0-FCV-032-0085-B 2-LCV-070-0063 O-CMP-032-0086-B 0-LOCL-500-0428 2-LOCL-500-0019 2-TNK-070-0063 Evaluated by: Robert Malone Date: 8/3/12 Phillip York 8/3/12 Page 400 of 444 Status: Y[C NEl U[-]Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 669 Room, Area 4 34 -Feedwater Pump 2A-S Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YZ NEI UE1 N/AE 2. Does anchorage of equipment in the area appear to be free of significant Y M N E UE N/A E degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y[ NEI UE N/AE 4. Does it appear that the area is free of potentially adverse seismic spatial YZ NEI UE1 N/AE interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 401 of 444 Location: Bldg. Auxiliary Floor El. 669 Room, Area 4 34 -Feedwater Pump 2A-S Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YM NO U- N/AO YC NEI U- N/AF YM NE UE N/A-8. Have you looked for and found no other seismic conditions that could YN NEI UE-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-TS-001-0018A-B 2-TS-001-0018B-B Evaluated by: Robert Malone Date: 8/6/12 Phillip York 8/6/12 Page 402 of 444 Status: Y 0 NEl UI-D Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 669 Room, Area 4 35 -Charaing Pump Room 2B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

Y19 NEI Ur N/AE[2. Does anchorage of equipment in the area appear to be free of significant YZ NEI UE1 N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Two elbow conduit covers were missing. Not considered seismically adverse.4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YC NEI UE N/AE1 YN NO UE- N/AO 4 If the room In which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 403 of 444 Location: Bldg. Auxiliary Floor El. 669 Room, Area 4 35 -Charqing Pump Room 2B 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Y C N E UE N/AE YN NEI UO N/A-YZ NEI UEr N/AE 8. Have you looked for and found no other seismic conditions that could Yr NEI Ur adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-PMP-062-0104 Evaluated by: Robert Malone Date: 8/6/12 Phillip York 8/6/12 Page 404 of 444 Status: YE NZ UD-Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 36 -6.9kV Shtdwn Board Rm B (U2 Side)Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YX NO UE N/AE 2. Does anchorage of equipment in the area appear to be free of significant Y M NE1 UEl N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Y M NE: U E- N/A E Y M NE: UE N/AE 4 If the-room In which the SWEL ite. is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on Judgment, e.g., on the order of about 35 f.et from the SWEL item.Page 405 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 36 -6.9kV Shtdwn Board Rm B (U2 Side)5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? Scaffolding in area, in front of compartments 10 & 11, requires another tie-offpoint opposite of existing tie-offpoint to prevent tipping. Wheels were restrained properly to prevent rolling. During next visit to area, scaffolding was properly anchored to pipe support extending from ceiling.YCK NE UE- N/AE YCK NEI UE N/AE YE N Z UE N/AE 8. Have you looked for and found no other seismic conditions that could YN NEI UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDB-202-CP Evaluated by: Robert Malone Date: 8/7/12 Phillip York 8/7/12 Page 406 of 444 Status: YIE- NIZ U E-Area Walk-By Checklist (AWC)Location: Bldg. Control Floor El. 669 Room, Area 4 37 -Control 669 Mech Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?
2. Does anchorage of equipment in the area appear to be free of significant degraded conditions?
3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?In one location a copper line rubs on insulation for ductwork.

Since this is a flexible copper line, this condition is deemed to be insignificant.

4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?
5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?In one location a nozzle on the fire protection line is very close to a conduit on the ceiling (from visual inspection from thefloor, it appears to be within I "of the conduit).

This nozzle is in the middle of a pipe span of about 4' -5' (between hangers).Vertical movement will likely be limited, since adjacent FP line spanning bays are -10' (between supports) and vertical acceleration is not likely to cause a vertical movement of] ".YZ NEI UE] N/AE Y 0 NE U E- N/AEl YM NEI UE] N/AE1 y* N[E U E] N/AE yE-: NIC UE-' N/AE Fire protection hanger in the center of the room (between AHU A-A andAHUB-B has apin with a nut that is loose. This nut needs to be tightened to the vertical support tabs. Possible spray hazard as if nut comes loose the fire protection line could be overstressed 4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL it.m.Page 407 of 444 Location: Bldg. Control Floor El. 669 Room, Area 4 37 -Control 669 Mech Room 6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YZ NEI UE- N/AEl YN NEI UO N/AE 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?There is moderate mineral buildup /corrosion on conduit (and associated anchorage), conduit support steel baseplate, and electrical cabinet behind pipe on wall near 0-CHR-311-171. There appears to be some type of leak near the ceiling. This condition is not considered to be seismically adverse, but it should be monitored forfuture degradation. Control Bldg Elec Bd Rm Alt Fan A-A Mtr (O-MTRB-311-0027) has one mounting nut that is not fully engaged (appears to be about 50% engaged). The loose nut is on one (of two) of the all thread rods at the base of the motor mounting frame (on the mounting rod that does not have a sleeve). This is not considered to be seismically adverse because it appears that this condition has not developed from the nut "backing off' (or any other kind of damage). It appears that this condition is the result of the base rod being too short.YN ND UFI Comments (Additional pages may be added as necessary) Evaluated by: Lance Summers Date: 8/7/12 Isaac Antanaitis 8/7/12 Page 408 of 444 Status: YE] NO U[]Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 38 -Aux Feedwater Pump B Area Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YM NE UE- N/AD 2. Does anchorage of equipment in the area appear to be free of significant Y 0 N E- U E N/A E degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YM NEI UE] N/AE 4. Does it appear that the area is free of potentially adverse seismic spatial Y M N E U E N/A E interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room In which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 409 of 444 Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 38 -Aux Feedwater Pump B Area 5. Does it appear that the area is free of potentially adverse seismic YN NEI UO N/AE interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic YE NEI UE N/AE interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic YrE N E UE N/AE0 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? 55 gallon barrels in the area are not properly restrained Much of the equipment in the area has soft targets, including valves, gauges, and small tubing.8. Have you looked for and found no other seismic conditions that could YN NEI UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) Fire Protection cabinet is not restrained but the height/width ratio is less than 2 and the cabinet is not prone to tipping. Inspection tag was located on cabinet and appeared to be installed per plant procedure. The following equipment is included in the area encompassed by this Area Walk-By: 2-PMP-003-0128 2-FCV-003-0126A-B 2-LOCL-500-0222B Evaluated by: Robert Malone Date: 8/7/12 Phillip York 8/7/12 Page 410 of 444 Status: YIC N[l] UEl Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 39 -2B RHR CCS HEX Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YCK NEI U- N/AE 2. Does anchorage of equipment in the area appear to be free of significant YIN NE UE N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YN NEI UE--N/AE1 YN NO UE N/AE 4 If the roo. in which the SWEL item is located Is very large (e.g., Turbine Hall). the area selected should be described. This selected area should be based on judgment, e.g.. on the order of about 35 feet from the SWEL item.Page 411 of 444 Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 39 -2B RHR CCS HEX Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NE UE N/AE Yr NE UE N/AO Y19 NEI UE N/AE 8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?Y E N] 0UEl Comments (Additional pages may be added as necessary) An unrestrained ladder was found on the very top platform in the room. There was no equipment in the area and this was not considered seismically adverse.The following equipment is included in the area encompassed by this Area Walk-By: 2-HEX-072-0007 2-HEX-074-0027 Evaluated by: Robert Malone Date: 8/7/12 Phillip York 8/7/12 Page 412 of 444 Status: Y[0 NEl ULI Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 714 Room, Area 4 40 -Shutdown Board B Area Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YER NEI UE- N/AEl 2. Does anchorage of equipment in the area appear to be free of significant Y[R NIl Ui- N/Ail degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YN NO Uil N/A]4. Does it appear that the area is free of potentially adverse seismic spatial Y Z N i U il N/A il interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room In which the SWEL Item Is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 413 of 444 Location: Bldg. Auxiliary Floor El. 714 Room, Area 4 40 -Shutdown Board B Area 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NE UEr-N/AE YCK NEI UE] N/AE YM NEI UE1N/AE 8. Have you looked for and found no other seismic conditions that could YN NE UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: O-CHR-313-0338 Evaluated by: Robert Malone Date: 8/8/12 Phillip York 8/8/12 Page 414 of 444 Status: YZ NEI UI-Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 42 -2A RHR CCS HEX Room Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YM NO UE N/AE 2. Does anchorage of equipment in the area appear to be free of significant YM NEI U- N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YN NEI UE] N/AE 4. Does it appear that the area is free of potentially adverse seismic spatial YX NEI UE N/AE interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room in which the SWEL item is located is .very large (e.g., Turbine Hall), the .e... Is..e.d should be described. This selected area should be based on judgment, e.g., on the order of about 35 f.et from the SWEL item.Page 415 of 444 Location: Bldg. Auxiliary Floor El. 690 Room, Area 4 42 -2A RHR CCS HEX Room 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? A roll of tape was found on top of the RHR heat exchanger. There were no soft targets in the area and this was not considered seismically adverse.YM NE Ur N/AE YER NEI UEr N/A-YC NEI UEr N/A-8. Have you looked for and found no other seismic conditions that could YM NEI UE1 adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-HEX-072-0030 2-HEX-074-O015 Evaluated by: Robert Malone Date: 8/2/12 Phillip York 8/2112 Page 416 of 444 Status: YE] UD Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 669 Room,.Area 4 43 -SI Pump Area instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YZ NEI UE1 N/AEr 2. Does anchorage of equipment in the area appear to be free of significant YZJ NEI UE N/AE]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YER NE U N/AD YM NE UE N/AE 4 If the room in which the SWEL item is located Is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 417 of 444 Location: Bldg. Auxiliary Floor El. 669 Room, Area 4 43 -SI Pump Area 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?55 gallon barrels in the area are not properly restrained Much of the equipment in the area has soft targets, including valves, gauges, and small tubing.6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic: interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YEI NO UE N/AE YO NEI UE: N/AE YO NE UE1 N/AE 8. Have you looked for and found no other seismic conditions that could Y[ NEI UEr adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-FCV-067-0176-A 2-FCV-067-0182-B Evaluated by: Robert Malone Date: 8/1/12 Phillip York 8/1112 Page 418 of 444 Status: Y Z N[0 U E Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 653 Room, Area 4 44 -CS PumD Room 2B Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NO UE N/AE1 2. Does anchorage of equipment in the area appear to be free of significant YZ NEI UE1 N/AE-degraded conditions? Light rust on pipe hanger. Not credible.3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y NE] UE N/AEl 4. Does it appear that the area is free of potentially adverse seismic spatial Y M NEl U E N/AE interactions with other equipment in the area (e.g., ceiling tiles and lighting)? 4 If the room I. which the SWEL item is located is very large (e.g., Turbine Hai), the area l..c..td should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 419 of 444 Location: Bldg. Auxiliary Floor El. 653 Room, Area 4 44 -CS Pump Room 2B 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NEI UEI N/AF YZ NE U0 N/AE]Y19 NEI UO N/AE 8. Have you looked for and found no other seismic conditions that could YN NO UE adversely affect the safety functions of the equipment in the area?Partial block wail for equipment removal in one concrete wall of room.Block wall is anchored by steel bars with bolts into concrete.Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-CLR-030-0178 Evaluated by: Isaac Antanaitis Date: 8/22/12 Phillip York 8/22/12 Page 420 of 444 Status: YlZ NEI UI-E Area Walk-By Checklist (AWC)Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 45 -125V Vital Battery Board Room IV Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NEI UW- N/AO 2. Does anchorage of equipment in the area appear to be free of significant Y M NWE UWl N/ADE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YER NE UW N/AW 4. Does it appear that the area is free of potentially adverse seismic spatial YM NEI UW1 N/AW interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

4 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 421 of 444 Location: Bldg. Auxiliary Floor El. 734 Room, Area 4 45 -125V Vital Battery Board Room IV 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? A temporary cover is being used for an overhead cable near the back corner of 125 V DC Vital Battery Board IV (O-BDG-250-KH-G) -panel 4.YIN NO ULI- N/AL]YN NEI UI- N/AO YX NEI U- N/AO 8. Have you looked for and found no other seismic conditions that could YN NO UW adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-BDE-250-NK-G" There is visual evidence of a concrete patch for fire protection penetration in the ceiling." Block walls on North, South, and East side of the room are reinforced seismic category 1 walls per TVA drawings 46W405-5, 46W405-9, and 46W405-15. Most of the front wall has a concrete header instead of the typical angle connection to ceiling slab, which is consistent with drawing 46W405-15. Evaluated by: Lance Summers Date: 7/26/12 Isaac Antanaitis 7/26/12 Page 422 of 444 Status: Y 0 N E- UI-l Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 693 Room, Area' 46 -Accumulator Room 3 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YM NE1 UE] N/AE 2. Does anchorage of equipment in the area appear to be free of significant Y M NE U E N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?Y1 NEI UE- N/AE--4. Does it appear that the area is free of potentially adverse seismic spatial YZ NO UE] N/AEl interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 423 of 444 Location: Bldg. Reactor Floor El. 693 Room, Area' 46 -Accumulator Room 3 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? The condition in Unit 2 during this walk-by was Refueling outage with Steam Generator replacement. The fuel is off-load in the Spent Fuel Pit. The unit is currently in a No Mode, as per Tech Specs. Minor temporary equipment and housekeeping issues were disregarded because of this condition. YN Nr Ur N/AO YM NO UE N/Ar YN NO UE N/AE 8. Have you looked for and found no other seismic conditions that could Yr NO UEr adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-FCV-063-0090 Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 424 of 444 Status: YiM NEI ut]Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 693 Room, Area, 47 -. Fan Room 1 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YCK NEI Ut] N/At]2. Does anchorage of equipment in the area appear to be free of significant YZ Nt] Ut] N/At]degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Scaffold support was found to be in contact with small bore piping behind instrument. Not considered significant. YN Nt] Ut] N/At]YN NEI Ut] N/At]1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 425 of 444 Location: Bldg. Reactor Floor El. 693 Room, Area 1 47 -Fan Room 1 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? The condition in Unit 2 during this walk-by was Refueling outage with Steam Generator replacement. The fuel is off-load in the Spent Fuel Pit. The unit is currently in a No Mode, as per Tech Specs. Minor temporary equipment and housekeeping issues were disregarded because of this condition. YZ NEI UE N/AE YZ NE U] N/AE]YN NO UO N/AO 8. Have you looked for and found no other seismic conditions that could Y[ NE UE-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-CLR-030-0074 2-LOCL-500-0183C Evaluated by: Robert Malone Date: 11/9/12 Phil/li York 11/9/12 Page 426 of 444 Status: Y 0 NE UEZ-Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 693 Room, Area' 48 -Acculumator Room I Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results ofjudgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NEI UO N/AE 2. Does anchorage of equipment in the area appear to be free of significant YNl NO UF N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YZ NEI UE N/AE YZ NO UE N/AE I If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 427 of 444 Location: Bldg. Reactor Floor El. 693 Room, Area' 48 -Acculumator Room 1 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? The condition in Unit 2 during this walk-by was Refueling outage with Steam Generator replacement. The fuel is off-load in the Spent Fuel Pit. The unit is currently in a No Mode, as per Tech Specs. Minor temporary equipment and housekeeping issues were disregarded because of this condition. YM NE UE N/AE YN NEI UE N/AE: YX NEI UE[ N/AE 8. Have you looked for and found no other seismic conditions that could Y[K NEI UE-adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-TN K-063-0119 2-FCV-063-0118 Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 428 of 444 Status: YlZ NIE- UDEl Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 693 Room, Area' 49 -Accumulator Room 4 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YE NO UE N/AE 2. Does anchorage of equipment in the area appear to be free of significant YM NEI UE N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YZ NEI .UE N/AE 4. Does it appear that the area is free of potentially adverse seismic spatial YCK NEI UE N/AE]interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 429 of 444 Location: Bldg. Reactor Floor El. 693 Room, Area 1 49 -Accumulator Room 4 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? The condition in Unit 2 during this walk-by was Refueling outage with Steam Generator replacement. The fuel is off-load in the Spent Fuel Pit. The unit is currently in a No Mode, as per Tech Specs. Minor temporary equipment and housekeeping issues were disregarded because of this condition. YC NEI UE N/AE YZ NE UE N/AE YZ NEI UEN/AE 8. Have you looked for and found no other seismic conditions that could YN NEI UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-TN K-063-0060 Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 430 of 444 Status: Y 0 N[E u E]Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 747 Room, Area' 50 -Annulus AZ 277 Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NEI UE N/AE 2. Does anchorage of equipment in the area appear to be free of significant YZ NE UE] N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?YIM N] UE] N/AE]4. Does it appear that the area is free of potentially adverse seismic spatial YZ NE] Uc] N/AE]interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

'If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 431 of 444 Location: Bldg. Reactor Floor El. 747 Room, Area' 50 -Annulus AZ 277 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? YN NO UE N/AE YZ NEI UE N/AE:]YM NO Ur N/AE]8. Have you looked for and found no other seismic conditions that could adversely affect the safety functions of the equipment in the area?YE NEO UO Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-PSV-001-0024A-A 2-PSV-001-0013B-B Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 432 of 444 Status: Y 0 N- U-Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 680 Room, Area, 51 -Inside Polar Crane Wall Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YM NEI U- N/AEI 2. Does anchorage of equipment in the area appear to be free of significant YZ NEI UE N/A[degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

YM NEI UE-N/AE]YN NO UE N/AE 1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 433 of 444 Location: Bldg. Reactor Floor El. 680 Room, Area' 51 -Inside Polar Crane Wall 5. Does it appear that the area is free of potentially adverse seismic interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? The condition in Unit 2 during this walk-by was Refueling outage with Steam Generator replacement. The fuel is off-load in the Spent Fuel Pit. The unit is currently in a No Mode, as per Tech Specs. Minor temporary equipment and housekeeping issues were disregarded because of this condition. YZ NO UE N/AE YZ NEI UE N/AD YN NE UE N/AE 8. Have you looked for and found no other seismic conditions that could YZ NEI UE[adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary) The following equipment is included in the area encompassed by this Area Walk-By: 2-AHU-030-0088 2-AHU-030-0080 Evaluated by: Robert Malone Date:. 11/9/12 Phillip York 11/9/12 Page 434 of 444 Status: Y[Z N El ULE3 Area Walk-By Checklist (AWC)Location: Bldg. Reactor Floor El. 708 Room, Area, 52 -- Incore Inst Room Plafform Instructions for Completing Checklist This checklist may be used to document the results of the Area Walk-By near one or more SWEL items. The space below each of the following questions may be used to record the results of judgments and findings.Additional space is provided at the end of this checklist for documenting other comments.Note: Y = Yes, N = No, U = Unknown, N/A = Not Applicable

1. Does anchorage of equipment in the area appear to be free of potentially adverse seismic conditions (if visible without necessarily opening cabinets)?

YN NE UE- N/AE 2. Does anchorage of equipment in the area appear to be free of significant YZ NEI UE N/AE degraded conditions?

3. Based on a visual inspection from the floor, do the cable/conduit raceways and HVAC ducting appear to be free of potentially adverse seismic conditions (e.g., condition of supports is adequate and fill conditions of cable trays appear to be inside acceptable limits)?4. Does it appear that the area is free of potentially adverse seismic spatial interactions with other equipment in the area (e.g., ceiling tiles and lighting)?

Unrestrained ladders were found in the area but did not appear to be near any sensitive equipment. Not significant. YZ NEI UEN/AE YZ NEI UE1 N/AE1 1 If the room in which the SWEL item is located is very large (e.g., Turbine Hall), the area selected should be described. This selected area should be based on judgment, e.g., on the order of about 35 feet from the SWEL item.Page 435 of 444 Location: Bldg. Reactor Floor El. 708 Room, Area' 52- Incore Inst Room Platform 5. Does it appear that the area is free of potentially adverse seismic YN NEI UE N/AE7 interactions that could cause flooding or spray in the area?6. Does it appear that the area is free of potentially adverse seismic yCK NE Ur N/AE interactions that could cause a fire in the area?7. Does it appear that the area is free of potentially adverse seismic YM NEI U0 N/A0 interactions associated with housekeeping practices, storage of portable equipment, and temporary installations (e.g., scaffolding, lead shielding)? The condition in Unit 2 during this walk-by was Refueling outage with Steam Generator replacement. The fuel is off-load in the Spent Fuel Pit. The unit is currently in a No Mode, as per Tech Specs. Minor temporary equipment and housekeeping issues were disregarded because of this condition.

8. Have you looked for and found no other seismic conditions that could YM NE UE adversely affect the safety functions of the equipment in the area?Comments (Additional pages may be added as necessary)

The following equipment is included in the area encompassed by this Area Walk-By: 2-AHU-313-0262 Evaluated by: Robert Malone Date: 11/9/12 Phillip York 11/9/12 Page 436 of 444 Appendix G: Peer Review Report Page 437 of 444 FACILITY RISK CONSULTANTS, INC.Structural & Seismic Engineering & Risk Management NTTF 2.3/SQN-02 November 12, 2012 PEER REVIEW REPORT Sequoyah Nuclear Plant Unit 2 Near-Term Task Force 2.3 Seismic Walkdowns A peer review of the Tennessee Valley Authority (TVA) Sequoyah Nuclear Plant -Unit 2 (SQN2)seismic walkdowns for Near-Term Task Force (NTTF) Recommendation 2.3: Seismic was performed in accordance with the U.S. Nuclear Regulatory Commission (NRC) 50.54 (f) letter (listed as Reference 2 in the SQN2 Seismic Response Report) and the guidance provided in Electric Power Research Institute (EPRI) Report 1025286 (listed as Reference 3 in the Seismic Response Report).A highly interactive process was utilized by the peer review team. This involved ongoing open dialog consultation with project participants throughout training, equipment selection, equipment walkdowns, area walkbys, review of potentially adverse seismic conditions and corrective action program documentation, and final report preparation. In summary, the peer review team is in full concurrence with the final results as documented in the SQN2 Seismic Response Report, and we conclude that all of the project requirements have been met and adequately documented. The following sections summarize the details of the peer review process for the major elements of the project.TRAINING The walkdown teams are described in Section 3 of the SQN2 Seismic Response Report. All of the walkdown team members successfully completed the EPRI developed training on NTTF Recommendation 2.3 -Seismic Walkdown Guidance. All of the individual team members meet the qualification requirements as defined in EPRI Report 1025286. In addition to this EPRI training, per our recommendations, all walkdown team members received additional training.The purpose of the additional training was two-fold. First, additional technical training was provided on equipment anchorage and seismic interaction evaluations, as an enhancement to the anchorage and interaction issues overview provided in the EPRI training course. Second, background information was provided on the site-specific seismic programs implemented by TVA at SQN. This provided team members with historical background on the scope and findings of prior seismic reviews, as well as to deepen their understanding of the seismic licensing basis for SQN.Examples of the additional plant-specific training material provided for the team members include the following:

  • Description of SQN seismic design basis 0.18g Housner-shaped ground motion response spectrum* Scope of the Nuclear Performance Plan (NPP, NUREG 1232, Volume 2) commitments at SQN. This included the following major civil/seismic programs:-Programmatic control of safety-related design modifications FACILITY RISK CONSULTANTS, Inc. e 6275 University Dr., Ste. 37
  • Huntsville, AL 35806-1776 9 Tel: 256-679-3234 www.facflityrisk.com Page 438 of 444 NTTF 2.3/SQN-02 November 12, 2012 Page 2 of 7-Cable tray support analytical basis-Application of alternate analysis methods to non-rigorously analyzed piping and supports-Appendix R fire protection

-Welding issues-Instrument tubing & sense lines-Quality issues with replacement components and parts-Misc. employee concerns Major Civil/Seismic programs implemented as a result of the SQN NPP-Equipment Anchorage/Reaction Load Validation" Safety-related equipment" Tanks and other major items-Seismic Category I(L) Piping Hazards" Position retention -Il/I failure & falling issues" Pressure retention -Il/I spray issues-Distribution/Suspended Systems Programs and Design Criteria E Conduit, cable trays, and supports-Concrete/Masonry Wall & Embedded Plates Issues-Structural Platform attachment loads and thermal growth effects* Seismic Individual Plant Examination for External Events (IPEEE)-Review Level Earthquake (RLE) for seismic IPEEE implementation at SQN-Scope of review and Safe Shutdown Equipment List (SSEL)-Summary of SQN seismic IPEEE walkdown results-Presentation of results and governing High Confidence Low Probability of Failure (HCLPF) capacities, including original free field definition of RLE as implemented by TVA and subsequent rock outcrop definition resulted from NRC review-Discussion of enhanced seismic IPEEE efforts to increase plant HCLPF capacity to more than 0.30g as defined at rock outcrop" Plant procedures that overlap with the NTTF 2.3 seismic walkdowns: -Temporary Equipment-- NPG-SPP-09.17 -Scaffolding -- MMTP-102-Seismic Interaction Commodity Clearance Requirements -- M&AI-28 and N2C-948 SELECTION OF ITEMS ON THE SEISMIC WALKDOWN EQUIPMENT LIST (SWEL)The completed SWEL as described in Section 4 of the SQN2 Seismic Response Report is in full compliance with the guidelines in EPRI Report 1025286.The SWEL 1 represents a diverse sample of selected equipment and support systems required to perform the five safety functions of reactor reactivity control, reactor coolant pressure control, reactor coolant inventory control, decay heat removal, and containment function. The SWEL 1 includes, as appropriate, various types of systems, classes of equipment, and equipment environments. The SWEL 1 includes new and replacement equipment. The SQN IPEEE review was performed using the EPRI margins methodology and that success path based SSEL associated with SQN2 was used as a starting point for SWEL 1. No seismic PRA has been performed for SQN2 so no information regarding dominant contributors to Page 439 of 444 FACILITY RISK CONSULTANTS, INC. NTTF 2.3/SQN-02 November 12, 2012 Page 3 of 7 seismic risk was available. SWEL 1 was compared to the Core Damage Frequency (CDF) and Large Early Release Frequency (LERF) Rankings, and any shared equipment was noted.The SWEL 2 represents selected equipment related to the spent fuel pool system, including those that could cause rapid drain-down of the pool and accidental exposures of the fuel assemblies. There was considerable interaction between the peer review team, the walkdown team, and the equipment selection team during the course of the evaluation. The final SWEL, as documented in Section 4 and in Appendix D of the SQN2 Seismic Response Report, is a culmination of this interaction. Examples of peer review comments that were adequately addressed and resolved during the SWEL development process include the following:

  • During the development of the preliminary SWEL, there was confusion regarding the equipment class definition, in particular, instrument racks (18), temperature sensors (19), distribution panels (14) and medium voltage switchgears (03). These were clarified and corrected in the final SWEL. As such, the 120VAC vital instrument power boards are in the distribution panel equipment class, and the 6.9kV shutdown boards are added to the medium voltage switchgear equipment class.* In order to include representative equipment items for all of the 21 classes of equipment listed in Table B-1 of the EPRI Report 1025286, items of equipment were added to the SWEL that were not part of the IPEEE review. It was noted that this was unnecessary yet conservative, so the items remained on the SWEL.* During the initial phase of the SWEL development, it was noted that no equipment were selected inside the Reactor Building.

Subsequently, selected equipment items in the Reactor Building were added to the final list." Selected SQN2 equipment items identified as outliers in SQN seismic IPEEE review were added to the SWEL for confirmation of seismic IPEEE upgrades. This is to address reporting of the evaluations related to seismic vulnerabilities identified during that program." It is noted that the final SWEL adequately includes equipment in each major building structure and encompasses mild to more severe environments. SEISMIC EQUIPMENT WALKDOWNS AND AREA WALKBYS The peer review team spent considerable time interfacing with the walkdown team members during the SQN2 seismic equipment walkdowns and area walkbys. This included responding to questions regarding the scope and content of the reviews. This also included in-plant observations of the teams during the reviews as well as independent in-plant reviews of individual equipment components. Walkdown observations and results were reviewed and discussed on a weekly basis with the walkdown team members. Particular emphasis was given to any items preliminarily identified as potential adverse seismic conditions (see discussion in the next section). In the end, the peer review addressed over 50% of the completed walkdown documentation forms.It is noted that the in-plant activity and over 50% documentation review is above and beyond the peer review requirements as defined in EPRI Report 1025286. As a result of this effort, we are Page 440 of 444 FACILITY RISK CONSULTANTS, INC. NTTF 2.3/SQN-02 November 12, 2012 Page 4 of 7 highly confident that the teams conducted the reviews in a thorough and competent manner, and that the reviews are fully in compliance with the intent of the NRC 50.54 (f) letter.Examples of walkdown team observations and seismic issues discussed and resolved during the course of the peer review process for the SQN2 equipment seismic walkdowns and area walkbys include the following:

  • The walkdown teams diligently verified presence of safety cables or wires on miscellaneous overhead features (such as lights and speakers) and spring locks on florescent light tubes for all electrical equipment panels. Any exceptions were carefully reviewed and discussed.
  • The walkdown teams diligently noted all cracks including minor hairline cracks in floors in the vicinity of equipment and even in structural walls. Each instance was discussed at length and resolved, and no items were found to be significant.

For the masonry walls, all of cases were verified to be Seismic Category I reinforced block wall structures, and that hairline cracks were insignificant.

  • The walkdown teams diligently verified seismic adequacy issues associated with equipment anchor condition and anchorage load path, such as bent, missing or loose hardware, anchor edge distance and rust conditions.

Each instance was reviewed and discussed thoroughly. Conditions were generally determined to be insignificant, thus did not affect seismic capacity and were accepted as-is. Others were qualified as-is based on existing documentation.

  • The walkdown teams diligently noted instances of unusual supports on overhead systems, such as bent rod hangers and missing anchor bolts. Based on further discussion, in all cases it was determined that the vertical load carrying capability of the overhead supports was not compromised, thus did not pose as a seismic falling interaction hazard.* The walkdown teams diligently noted instances of potential seismic interaction sources to assess their effects on the nearby safety related equipment items. Examples include fire extinguishers, frisker on unanchored table, unanchored barrier posts and cantilevered fire barrier wall. Based on further discussion and review, in all cases it was determined that the potential source was either evaluated and qualified previously as documented in calculation, or deemed to be insignificant.
  • At the DG 2A-A Battery Rack, the walkdown teams noted an emergency eye wash station was not adequately restrained and could potentially roll and topple over during a seismic event and spill or spray water in the room. This was determined not to represent a significant hazard to the batteries, but the eye wash was subsequently restrained.
  • The skids for each of the diesel generators were inspected in detail by the walkdown teams, and they had preliminary concerns that the base frames for the engine and the generator were not linked together by steel members as shown on the original design drawings.

After considerable discussion and reviewing the load paths, it was concluded that the base frames are very rigid, and that these are each anchored to the same rigid massive concrete base, so that it was not possible for the engine and the generator to experience any differential seismic movement.Page 441 of 444 FACILITY RISK CONSULTANTS, INC. NTTF 2.3/SQN-02 November 12, 2012 Page 5 of 7" On electrical panel line-up inspections, the walkdown teams checked for bolting between adjacent panels. In one case, for the DG 2A-A Control Panel, they observed that 1 of 8 bolts was missing in the cabinet-to-cabinet connection. It was agreed that the one missing bolt was insignificant.

  • During the area walkbys, the teams noted cases where conduit exiting top of MCCs were in proximity to overhead rigidly supported cable trays. Examples areas include the DG 2A and 2B Board Rooms. Simple conservative equations were used to estimate deflection, and in all cases it was confirmed that the clearance was adequate for the component design basis earthquake deflections." During the area walkbys, the teams noted isolated instances of not full thread engagement at bolted connection and misaligned unistrut channel nut connection.

Each instance was reviewed and discussed thoroughly, and considered acceptable based on its as-installed configuration.

  • During the area walkbys, the teams noted a variety of temporary equipment and installations such as scaffoldings, ladders, tools and tool boxes. In all cases, conditions were assessed and determined to be acceptable as-is.In the end, the peer review team is in concurrence with the Seismic Walkdown Checklists (SWCs) and Area Walkby Checklists (AWCs) as presented in Appendices E and F, respectively, of the SQN2 Seismic Response Report.POTENTIAL ADVERSE SEISMIC CONDITIONS The peer review team spent considerable time with the walkdown teams addressing preliminary potential adverse seismic conditions identified during walkdowns.

It is noted that there were very many questions early in the walkdown review process on the conservative side of issues, and these kinds of questions diminished towards the end of the project as the judgment of the teams significantly improved. Most of these early concerns were in regards to potential seismic interaction effects. In most cases, these issues were resolved by review of prior evaluations or the TVA procedures and guidance already in place at the plant.All potential adverse seismic conditions were reviewed in detail, including working with the teams to address seismic licensing basis and operability issues for the confirmed potential adverse seismic conditions that resulted in the initiation of Problem Evaluation Reports (PERs)as part of the Corrective Action Program (CAP). In the end, the peer review team is in full concurrence with all of the potential adverse seismic conditions summarized in Sections 6.2 and 6.3 of the SQN2 Seismic Response Report.Comments regarding the individual potential adverse seismic conditions for SQN2 include the following: Potentially Adverse Seismic Condition 1 addresses a radiation protection cabinet that was marginally restrained in the Auxiliary Building Surge Tank B area at El. 734'. The cabinet was restrained on one of the two eye hook locations and in the current configuration it did not present a credible seismic interaction hazard to nearby safety related equipment. The walkdown team conservatively noted this as a potential adverse seismic condition and entered it into the CAP, and subsequently the cabinet was adequately restrained. Page 442 of 444 FACILITY RISK CONSULTANTS, INC. NTTF 2.3/SQN-02 November 12, 2012 Page 6 of 7* Potentially Adverse Seismic Condition 2 addresses a temporary ventilation fan in the 480V Board Room 2A, in the vicinity of motor control center 2-BDC-201-GM-A. The floor fan was secured with chain and did not appear to be a credible interaction hazard given the position of the fan and the distance to the MCC cabinet. The walkdown team conservatively noted this as a potential adverse seismic condition and entered it into the CAP, and subsequently the fan was removed." Potentially Adverse Seismic Condition 3 addresses a crack noted at the top of a block wall next to the angle restraint that is common to the 125V Vital Battery Room IV and the 480V Board Room 2B. Bounding analyses, in consideration of the steel reinforcing in the wall, were performed to demonstrate that the as-found condition had sufficient margin to withstand design basis seismic loading. The walkdown team conservatively noted this as a potential adverse seismic condition and entered it into the CAP. Further engineering evaluation determined that the condition is acceptable.

  • Potentially Adverse Seismic Condition 4 addresses unrestrained 55-gallon drums in the vicinity of safety-related instrument racks in the walkbys in the RHR, AFW and SI pump areas. In all cases, toppling or sliding of the drums would not compromise the safety function of instrument racks. The unrestrained drums however do not comply with applicable TVA procedures for restraint of temporary items. The walkdown team noted these cases as a potential adverse seismic condition.

A CAP entry was submitted to address this issue, and the temporary equipment (drums) were removed from the areas.* Potentially Adverse Seismic Condition 5 addresses a sink cabinet in the 125V Battery Room III that was not anchored in the same manner as the other battery rooms. Given its location with respect to the safety related equipment in the room, it was judged that the sink does not pose a seismic interaction and spray concern. The walkdown team noted this as a potential adverse seismic condition and entered it into the CAP.Subsequently, the design calculation for the current configuration was retrieved, which indicates that the unrestrained cabinet is not a seismic concern nor spray hazard and is acceptable as-is.Potentially Adverse Seismic Condition 6 addresses a missing bolt on a duct support above the Control Rod Drive Generator 2B (2-GEND-085-DH/3B) in the CRDM Room.The duct and support configuration is judged to be robust and rugged and in the current configuration it did not present a credible seismic falling interaction hazard to nearby safety related equipment. The walkdown team noted this as a potential adverse seismic condition and entered it into the CAP. Further engineering evaluation determined that the condition is acceptable. Potentially Adverse Seismic Condition 7 addresses a temporary scaffold near Unit 2 6.9kV Shutdown Board 2B-2 (2-BDB-202-CP). The walkdown team observed the scaffolding to be anchored only at one location at the top, noted the non-conforming scaffold as a potential adverse seismic condition, and entered it into the CAP.Subsequently, the scaffolding was observed to be adequately restrained on its upper corner to a permanent plant feature. The temporary scaffold is found to be in compliance with TVA procedures. Page 443 of 444 FACILITY RISK CONSULTANTS, INC. NTTF 2.3/SQN-02 November 12, 2012 Page 7 of 7 Potentially Adverse Seismic Condition 8 addresses an unanchored cabinet with broken latch on the cabinet door for flammable materials during the area walkby of the ERCW Pump Room 2A-A. Given the location of the cabinet, it does not represent a direct seismic interaction source for any safety related equipment. The walkdown team conservatively noted this as a potential adverse seismic condition and entered it into the CAP, and subsequently the door lock was repaired to provide positive enclosure of the flammable materials within the cabinet.* Potentially Adyerse Seismic Condition 9 addresses a nut and bolt not fully engaged on a fire protection pipe hanger in the vicinity of the Electrical Board Room Chillers. The walkdown team was concerned that the nut could loosen and become free during a seismic event. This is not considered to be a credible failure mode, and further evaluations indicated that the pipe hanger was able to perform its intended function.The walkdown team conservatively noted this as a potential adverse seismic condition and entered it into the CAP.* Potentially Adverse Seismic Condition 10 addresses a missing bolt attaching the axial fan of the Control Rod Drive Cooling Unit 2-AHU-030-0088 to its skid framework. The as-found configuration is stable and has sufficient margin to withstand design basis seismic loading -- 5 out of 6 bolts are sufficient to resist seismic demand shear loads; the flanged attachment of the fan to the AHU resists overturning moment. The walkdown team conservatively noted this as a potential adverse seismic condition and entered it into the CAP.SUBMITTAL REPORT The peer review team has reviewed the SQN2 submittal report in detail and we are in full concurrence with the documented observations and findings. The report is in compliance with the guidance in EPRI Report 1025286, and meets the requirements and objectives of the NRC 50.54 (f) letter.In our opinion, the potential adverse seismic conditions identified by the program are in general only minor issues, and this is a reflection of the adequate seismic design criteria as well as sufficiently rigorous seismic-related construction and maintenance procedures that TVA has in place at SQN2. The walkdown demonstrates that the current plant configuration is in compliance with the current seismic licensing basis. Furthermore, the walkdown demonstrates that that TVA has maintained or improved the seismic IPEEE HCLPF capacity of the plant.Sincerely, John 0. Dizon, P.E. Stephen J. Eder, P.E.Lead Peer Reviewer Peer Reviewer Page 444 of 444 FACILITY RISK CONSULTANTS, INC.}}