ML18184A118
ML18184A118 | |
Person / Time | |
---|---|
Site: | 03011772 |
Issue date: | 06/19/2018 |
From: | Ryan Craffey NRC/RGN-III |
To: | Reeve W JAN X-ray Services, JANX |
References | |
IR 2018001 | |
Download: ML18184A118 (2) | |
See also: IR 07200201/1980001
Text
NRC FORM 591M PART 1 U.S. NUCLEAR REGULATORY
COMMISSION
(07-2012)
10CFR 2 , 201 SAFETY INSPECTION
REPORT AND COMPLIANCE
INSPECTION
1. LICENSEE/LOCATION
INSPECTED:
JAN X-Ray Services d/b/a JANX 8550 East Michigan A venue, Parma, MI 49269 Location Inspected:
Job Site in Grayling, MI REPORT NUMBER(S)
2018001 2. NRG/REGIONAL
OFFICE Region III U.S. Nuclear Regulatory
Commission
2443 Warrenville
Road, Suite 210 Lisle, IL 60532-4352
3. DOCKET NUMBER(S)
4. LICENSE NUMBER(S)
5. DATE(S) OF INSPECTION
030-11772
21-16560-01
June 19, 2018 LICENSEE:
The inspection
was an examination
of the activities
conducted
under your license as they relate to radiation
safety and to compliance
with the Nuclear Regulatory
Commission (NRC) rules and regulations
and the conditions
of your license. The inspection
consisted
of selective
examinations
of procedures
and representative
records, interviews
with personnel, and observations
by the inspector.
The inspection
findings are as follows: [Z] 1. D 2. D 3. D 4. Based on the inspection
findings, no violations
were identified.
Previous violation(s)
closed. The violations(s), specifically
described
to you by the inspector
as non-cited
violations, are not being cited because they were self-identified, non-repetitive, and corrective
action was or is being taken, and the remaining
criteria in the NRC Enforcement
Policy, to exercise discretion, were satisfied.
Non-cited
violation(s)
were discussed
involving
the following
requirement(s):
During this inspection, certain of your activities, as described
below and/or attached, were in violation
of NRC requirements
and are being cited in accordance
with NRC Enforcement
Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance
with 10CFR 19.11. (Violations
and Corrective
Actions) Statement
of Corrective
Actions I hereby state that, within 30 days, the actions described
by me to the Inspector
will be taken to correct the violations
identified.
This statement
of corrective
actions is made in accordance
with the requirements
of 10 CFR 2.201 (corrective
steps already taken, corrective
steps which will be taken, date when full compliance
will be achieved).
I understand
that no further written response to NRC will be required, unless specifically
requested.
TITLE PRINTED NAME SIGNATURE
DATE LICENSEE'S
REPRESENTATIVE
NRC INSPECTOR
Ryan Craffey BRANCH CHIEF Aaron Mccraw NRG FORM 591M PART 1 (07-2012)
06/26/2018
06/29/2018
U.S. NUCLEAR REGULATORY
COMMISSION
NRC FORM 591M PART 3 (07-2012)
10 CFR 2.201 Docket File Information
SAFETY INSPECTION
REPORT AND COMPLIANCE
INSPECTION
1. LICENSEE/LOCATION
INSPECTED:
JAN X-Ray Services d/b/a JANX 8550 East Michigan A venue, Parma, MI 49269 Location Inspected:
Job Site in Grayling, MI REPORT NUMBER(S)
2018001 3. DOCKET NUMBER(S)
030-11772
6. INSPECTION
PROCEDURES
USED 87121 2. NRG/REGIONAL
OFFICE 4. LICENSE NUMBER(S)
21-16560-01
Region III U. S. Nuclear Regulatory
Commission
2443 Warrenville
Road, Suite 210 Lisle, IL 60532-4352
5. DATE(S) OF INSPECTION
June 19, 2018 7. INSPECTION
FOCUS AREAS FE 1-6 SUPPLEMENTAL
INSPECTION
INFORMATION
1. PROGRAM CODE(S) 03320 2. PRIORITY D Main Office Inspection
D Field Office Inspection
3. LICENSEE CONTACT William Reeve -RSO Next Inspection
Date: 4. TELEPHONE
NUMBER (517) 531-8210 No Change [{] Temporary
Job Site Inspection
Arauco Plant, West Four Mile Road, Grayling, MI PROGRAM SCOPE This was an unannounced
field inspection
of a large non-destructive
testing company authorized
to use radioactive
material for industrial
radiography
at numerous field stations and at temporary
jobsites throughout
NRC jurisdiction.
The scope of this inspection
was limited to observations
of radiographic
testing on the premises of a particleboard
manufacturing
plant, currently
under construction
in Grayling, Michigan.
PERFORMANCE
OBSERVATIONS
The inspector
observed the conduct of radiographic
operations
by the licensee's
crew at the plant construction
site in Grayling.
The crew routinely
worked overnight
at the site to minimize the potential
for exposure to members of the public, as the project was heavily staffed during the day. The inspector
noted the satisfactory
set-up and control of various restricted
area boundaries
during these operations, as supported
by independent
and confirmatory
surveys. The inspector
also noted adequate compliance
with physical presence requirements
for radiographic
operations.
Through interviews, the inspector
found that the radiographer
and his assistant
were knowledgeable
of radiation
protection
principles, licensee procedures and regulatory
requirements, and that their
dosimetry
and survey instruments
were calibrated, operable, and properly utilized.
The radiographic
exposure device they utilized, a SPEC Model 150, was likewise in good condition
and properly labeled. While on the jobsite, the inspector
reviewed the crew's shipping papers, utilization
logs, and leak test documentation.
No violations
ofNRC requirements
were identified
as a result of this inspection.
NRG FORM 591M PART 3 (07-2012)